IMPORTANT INFORMATION
When using electrical appliances, basic safety precautions should always be followed, including the following:
- Read all instructions.
- To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid.
- Do not operate with a damaged cord or plug, or after the appliance malfunctions, or has been damaged in any manner. Return the appliance to the nearest authorized service facility for examination, repair or adjustment.
- The use of accessory attachments or spare parts not recommended by the appliance manufacturer may result in fire, electrical shock or personal injury.
- Do not use outdoors.
- Do not use the appliance for other than the intended use.
- Do not place any strain on the power cord. Avoid twisting and/or tan­gling.
- Ensure that outlet vent of exhaust hose is kept debris-clear and obstruction free.
- Ensure that ventilation holes on the rear of the machine and front lou­vers are not blocked.
- The Pinguino should not be installed where the atmosphere could contain combustible gases.
- Avoid using Pinguino in oily or sulphurous atmospheres or near sour­ces of heat.
- Before moving the air-conditioner, empty water from collection tray (see instructions for drainage at page 7).
- Do not place hot or heavy objects on the appliance.
- Clean air filter every week (see instructions at page 12).
- Unplug from outlet when not in use and before cleaning.
-
Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge).
SAVE THESE INSTRUCTIONS
GB 14-05-2001 8:18 Pagina 3
4
97 (44)Net weight lb. (kg)
SPECIFICATIONS
Power supply voltage V see rating label*
60
see rating label*
see rating label*
188.35 cfm
R 22
18.03 (458)
33.46 (850)
15.74 (400)
Frequency Hz
Cooling capacity:
Current consumption
Air flow capacity
adjustableRoom thermostat
Refrigerant system (freon)
Overload relayCompressor protection (freon)
see rating label*Freon charge lb. (kg)
Dimensions : width in.(mm)
height in.(mm) depth in.(mm)
*Data according to pending standard testing procedures subject to review by the U.S. Dept.
of Energy.
OPTIMUM OPERATING RANGE
ROOM TEMPERATURE
ROOM HUMIDITY FACTOR
70°F - 90°F (21 - 35°C)
50%-80% RH
VOLTAGE
115V
FREQUENCY
60 HZ
POWER SUPPLY
GB 14-05-2001 8:18 Pagina 4
5
I
1
2
3
4
5
6
7
ABCD
OFF
ON
Removable filter
Control panel Air vent control knob
ILLUSTRATED MAIN FEATURES LIST
Control panel cover
Castors
Condensation discharge tube
Cable storage compartment
Carrying handle
Red reset button
Exaust hose
Suction hose
Hose coupling
GB 14-05-2001 8:18 Pagina 5
6
ACCESSORY LIST
DESCRIPTIONILLUSTRATION N° SUPPLIED
Cap + flange 2
Castor stop 2
Window nozzle
2
Adj window bracket 1
Exhaust hose 2
USING THE UNIT AS AN AIR­CONDITIONER
Installation
This new air-conditioner is highly versatile. It is portable, and can therefore be moved from room to room as required. Each room can be fitted with permanent vent holes.
30 cm
30 cm
O
N
I
O
F
F
Minimum distance from the walls: 30cm
GB 14-05-2001 8:18 Pagina 6