Important Safe-guards
• This appliance has been manufactured to cool and de-humidify domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in conformity with the relevant national legislation.
• This appliance is to be used by adults only; keep children away from it.
• Always ground the appliance. Have the electrical system checked by a qualified electrician.
•Avoid using extension leads with the unit.
• Before cleaning or maintenance operations, always unplug the unit from the socket.
• Do not pull on or place strain on the power cable when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.
• If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre­cautions to avoid that the refrigerant gases that may leak from the appliance do not remain in the room, thereby causing a fire hazard.
• This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater (31m
3
for model FX400ECO).
• Do not rest hot or heavy objects onto the appliance.
• Clean the anti-bacterial filters at least once a week.
•Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie horizontally. Before transporting the unit drain the condensation collecting­tray and tank. Avoid transportation, wait at least 1 hour before switching on the unit.
• The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection.
• Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised containers (eg. aerosol cans).
• The appliance must be used only as indicated in this manual. These instructions are not inten­ded to cover as many as possible conditions and situations which may arise. As with all hou­sehold appliances installation, operation and conservation should be carried out prudently and following common sense.
• In the case that the power cable becomes damaged, this must be substituted only by spe­cialised personnel authorised by the manufacturer.
• Do not cover this appliance with bags when is not in use.
• R290 is a refrigerant complying with european directives relative to the enviroment. Do not perforate any component of the refrigerating circuit.
• Unventilated area where the appilance using flammable refrigerants is installed shall be so constructed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion hazard caussed by igniting stagnant refrigerants from other source such as electric heater, stove and similar home applications.
FX160/400ECO GB 20-06-2002 16:51 Pagina 21
22
D
uring the summer, optimum comfort is achieved with a temperature of between 24 and 27˚C
and about 50% relative humidity.
An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings.
The hot air in your room is passed through a coil cooled by refrigerant gas, losing excess heat and moisture before being discharged again into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas befo­re, hot and moist air, is being discharged outside. In suitcase models (Super­Pinguino), the circuit is cooled using the air outsi­de.
For more details, contact or visit our Internet site
www.delonghi.com
How does your pinguino work
FX160/400ECO GB 20-06-2002 16:51 Pagina 22
23
ENGLISH
DESCRIPTION MODEL FX160ECO
1) Air discharge grill
2) Control Panel
3) Wheels
4) Handles
5) Housing for air exhaust hose
6) Cord winder
7) Air intake grill
8) Rating plate
9) Water collection tank
10) Water drain tube
11) Stopper for drain tube
12) Power cord
Description of the Accessories
13) Stopper and flange
14) Air exhaust hose
15) Air exhaust attachment
16)Suckers
17) Wheel locks
DESCRIPTION MODEL FX400ECO
1) External Unit
2) Air discharge grill
3) Control Panel
4) Internal/exter nal unit connection sheath
5) Wheels
6) Handles
7) Rating plate
8) Air intake grill
9) Power cord
10) Stopper for drain tube
11) Water drain tube
Description of Accessories
1) Wall brackets
2) Support blocks for external unit
3) Belts
4) Eyes
5) Screws and plugs
6) M6 and M4 screws
7) Condensate drain coupling
8) Suckers
9) Wheel locks
10) Wheels for exter nal unit
11) Sheath frame
Description of the appliance
FX160/400ECO GB 20-06-2002 16:51 Pagina 23
24
When positioning the appliance, always ensure that nothing obstructs the intake and discharge of air
AIR CONDITIONING WITHOUT PERMANENT INST ALLATION
Only a few simple steps are necessary to obtain the comfort offered by Pinguino.
Fit the air exhaust hose (14) in its housing (5) at the rear of the appliance as shown in fig.1
• If you have a double window, use the suckers (16) supplied to keep the panes from opening wide (figure 3).
• Fit the window discharge attachment (15) to the end of the hose (14)
• Place the air-conditioning unit at a win­dow or French window
• Open the window a little and position the attachment (15) as shown in fig. 2.
1
Setting up (Mod. FX160ECO)
2
3
FX160/400ECO GB 20-06-2002 16:51 Pagina 24
1
2
25
ENGLISH
Setting up (Mod. FX160ECO)
AIR CONDITIONING WITH SEMI-PERMA­NENT INSTALLATION
If desired, Pinguino can also be installed on a semi-permanent basis.
• Fit the flange (13) supplied to the hole.
• Fix the hose (14) in the housing at the rear of the appliance (fig 1)
• Fit the end of the hose to the flange (15) as shown in fig. 5.
In this case it will be necessary to:
• Drill a hole in a perimeter wall or in a win­dow pane. Observe the height limits (fig.
5) and the dimensions of the hole given in fig.4.
When the hose (14) is not connected, the hole can be closed off with the flange stop­per (12).
N.B. When operating the appliance with semi-per­manent installation, it is advisable to leave a door slightly ajar (even only 1cm), to ensure free circulation of air.
In the window­pane
In the wall: we advise you to insulate the sec­tion of the wall with appropria­te insulation material.
In the base of the window frame
4
5
DEHUMIDIFICATION
Position the appliance in the room without inserting the air exhaust hose (14); this ensures that the dehumidified air will be released directly into the atmosphere.
The air emitted through the front grill will be cold while the air from the rear will be warm (fig. 6) thus ensuring that the room is dehumi­dified without variation in temperature.
6
FX160/400ECO GB 20-06-2002 16:51 Pagina 25
30 cm
30 cm
MAX115 cm
MIN 50 cm