Dell OptiPlex 980 User Manual [he]

Page 1
Intelยฎ Active Management Technology v6.0
ืชื›ืจืขืž ืœื”ื ืžืœ ืšื™ืจื“ืž
ืœื•ื”ื™ื 
Intel AMT ืœืฉ ื˜ื ืจื˜ื ื™ืืœ ื™ืคืจื’ ืฉืžืชืฉืž ืงืฉืžืž
(AMT Redirection (SOL/IDE-R
AMT Redirection ืชืจื™ืงืก
Intel Management and ืืฉื™ื™ื”
Security Status
Intel Management and Security Status ืืฉื™ื™ื”
ืชื•ื™ืขื‘ ืŸื•ืจืชืค
ืชื•ื™ืขื‘ ืŸื•ืจืชืค
ื”ืจื™ื”ืžื• ื”ื˜ื•ืฉืค ื”ื™ื•ื•ื—
(Intel ืœืฉ ื”ืจื–ืขืœ ื”ืจื™ื”ืž ื”ืื™ืจืง) Intel Fast Call for Help
ืœื“ื—ืž ืชื•ืจื™ืจื‘ื• ืื™ื˜ื™ืจืคืช
MEBx ืชื•ืจื“ื’ื” ืœืฉ ื”ืจื™ืงืก
ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”
ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”
ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Setup and Configuration
USB ืŸืงืชื”ื‘ ืฉื•ืžื™ืฉ -- ื”ืจื•ืฆืช ืชืจื“ื’ื” ืชื•ืจื™ืฉ
USB ืŸืงืชื” ืœืฉ ืšื™ืœื” -- ื”ืจื•ืฆืช ืชืจื“ื’ื” ืชื•ืจื™ืฉ
ื”ืœืขืคื”ื” ืชื›ืจืขืž ืœืฉ ืื™ื ืงืชื” ื™ืœื”ื ืž
ืชื™ืœืœื› ื”ืจื™ืงืก
ืจืฆื•ืž ืชืจื™ืงืก
ื”ืœืขืคื” ื™ื‘ืฆืž
AMT ืชืจื•ืฆืช
AMT ืชืจื•ืฆืช
(ื”ืจื•ืฆืช
ืชื•ื˜ื™ืฉ ืชืจื™ืงืก
ืชื›ืจืขืž ืชืกื™ืจืค
.ื”ืžื™ืฉื™ ื”ื ื™ื ยฎMicrosoftยฎ Windows ื”ืœืขืคื”ื” ืชื›ืจืขืžืœ ื”ื– ืšืžืกืžื‘ ืชื•ืกื—ื™ื™ืชื” ืœื› ,DELLโ„ข n Series ื‘ืฉื—ืž ืชืฉื›ืจ ืื
.ื”ืขื“ื•ื” ืืœืœ ืชื•ื ืชืฉื”ืœ ื™ื•ืฉืข ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
.ืชื•ืจื•ืžืฉ ืชื•ื™ื•ื›ื–ื” ืœื› .Dell Inc 2010 ยฉ
.Dell Inc -ืž ื‘ืชื›ื‘ ื”ืืฉืจื” ืืœืœ ื”ืœื ืื™ืจืžื•ื— ืœืฉ ื’ื•ืก ืœื›ืž ื”ืงืชืขื” ืœืข ื˜ืœื—ื•ืž ืจื•ืกื™ื ืœื—
;ืชื•ืจื—ื ืชื•ื ื™ื“ืžื‘ื• ื‘"ื”ืจืื‘ Intel Corporation ืœืฉ ืื•ืฉืจ ื™ืจื—ืกืž ืŸืžื™ืก ืื•ื” Dell Inc; Intel ืœืฉ ืื™ื™ืจื—ืกืž ืื™ื ืžื™ืก ืื” DELL ื•ื’ื•ืœื”ื• Dell, Latitude :ื”ื– ื˜ืกืงื˜ื‘ ืฉื•ืžื™ืฉื‘ืฉ ืื™ื™ืจื—ืกืž ืื™ื ืžื™ืก
.ืชื•ืจื—ื ืชื•ื ื™ื“ืžื‘ ื•ื/ื• ืชื™ืจื‘ื” ืชื•ืฆืจืื‘ Microsoft Corporation ืœืฉ ืื™ืžื•ืฉืจ ืื™ื™ืจื—ืกืž ืื™ื ืžื™ืก ื•ื ืื™ื™ืจื—ืกืž ืื™ื ืžื™ืก ืื” Windows -ื• Microsoft
ืื™ื ืžื™ืกื‘ ื™ื ื™ื™ื ืง ืงืœื— ืœื› ืœืข ืชืจืชื•ื•ืž Dell Inc .ืŸื”ืœืฉ ืื™ืจืฆื•ืžืœ ื•ื , ืชื•ืžืฉื”ื• ืื™ื ืžื™ืกื” ืœืข ืชื•ืœืขื‘ืœ ืชื•ื ืขื•ื˜ื” ืชื•ื™ื•ืฉื™ืœ ืกื—ื™ื™ืชื”ืœ ื™ื“ื› ื”ื– ืšืžืกืžื‘ ืื™ืจื—ื ืื™ื™ืจื—ืกืž ืชื•ืžืฉื‘ื• ืื™ื™ืจื—ืกืž ืื™ื ืžื™ืกื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื™ื™ืฉ ืŸื›ืชื™ื™
.ื”ืชื•ืœืขื‘ื‘ืฉ ื”ืœืืœ ื˜ืจืค ืื™ื™ืจื—ืกืž ืชื•ืžืฉื• ืื™ื™ืจื—ืกืž
Rev. A00 2010 ืœื™ืจืคื
Page 2
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ืชื™ืœืœื› ื”ืจื™ืงืก
.ืŸื”ืœืฉ ืชืฉืจื” ื™ื‘ืฉื—ืž ืชื ืชื•ืœืงื‘ ืœื”ื ืœ ืชื•ืจื‘ื—ืœ ืชืจืฉืคืืž (Intelยฎ Active Management Technology (Intel AMT ืชื™ื™ื’ื•ืœื•ื ื›ื˜
ื•ืœื™ืคื ืŸืชื™ื  . ื‘ืฉื—ืžืœ ืชืฉื’ืœ ื™ื“ื› ืฃื™ื“ื  ืืœ ืชื›ืจืขืž ืŸื•ืจื›ื™ื–ื‘ ืŸืกื—ื•ืืžื” ืขื“ื™ืžื‘ ืชืฉืžืชืฉืž Intel AMT ืชื™ื™ื’ื•ืœื•ื ื›ื˜ โ€“ ืืœ ื•ื ืœืขื•ืค ื‘ืฉื—ืžื” ืื ืชื•ืœืช ืืœืœ , ืชืฉืจื‘ ื‘ื•ืฉื—ืž ื™ืกื›ื  ืชื•ืœื’ืœ
.(OOB ื•ื out-of-band ื”ืฉื™ื’ ืื’ ืืจืงื ) ืœืขืคื•ืž ื•ื ื™ื ืื•ื” ืจืฉืื› ื‘ืฉื—ืžืœ ืชืฉื’ืœ
ืงื•ื—ืจืž ื‘ืฉื—ืžืœ ืชืฉื’ืœ ื™ื“ื› Intel AMT -ื‘ ืฉืžืชืฉื”ืœ ืŸืชื™ื  ,ื”ืœืขืคื”ื” ืชื›ืจืขืžื‘ ื•ื ื”ื ื›ื•ืชื‘ ืœืฉื› ืœืฉ ื”ืจืงืžื‘ โ€“ ื”ืœืขืคื”ื” ืชื›ืจืขืžื‘ ืื™ืœืฉื› ืจื—ืืœ ืื’ , ืื™ื‘ืฉื—ืž ืงื•ื—ืจืž ืŸืงืชืœ
Intel ืœืฉ out-of-band ืชื•ืืจืชื”ื”ื• ืื™ืขื•ืจื™ืื” ืื•ืฉื™ืจ ืœืฉ ืขื•ื™ืกื‘ ื‘ืฉื—ืž ืชื•ื›ืจืขืžื‘ ืชื•ื™ืขื‘ ืชื•ืœืงื‘ ืชื•ื”ื–ืœ ืื™ืœื•ื›ื™ (IT) ืขื“ื™ืž ืชื™ื™ื’ื•ืœื•ื ื›ื˜ ื™ืœื”ื ืž , ืšื› ืœืข ืฃืกื•ื  .ืŸื•ืงื™ืช ืชื•ืจื˜ืžืœ
.AMT
.ืชืฉืจื” ื™ื‘ื—ืจื‘ ืื™ืกื•ืจื™ื•ื• ืชื•ื ื›ื•ืช ื™ื ืคืž ืชื™ื ื›ื“ืข ื”ื ื’ื” ืœืข ืชื•ืœืงื‘ ื”ืจื™ืžืฉ ื™ื“ื› ืšื•ืช ,ืื™ืกื ื›ื  ืื™ืžื•ื™ื ื™ื ืคืž ืชื•ืชืฉืจ ืœืข ืŸื’ื”ืœ
ื”ื ื›ื•ืช ืชื›ื™ืžืช
ืจื•ืฉืงื” ืœื›ื‘ ,ืชื•ื‘ืจ ืชื•ื™ื•ืจืฉืคื (IT) ืขื“ื™ืž ืชื™ื™ื’ื•ืœื•ื ื›ื˜ ื™ืœื”ื ืžืœ ืชื•ืงืคืกืž ื”ืœื ืชื•ืœื™ื‘ื— .Intel AMT ืชื•ื ื•ื›ืช ืืข ืชื•ืœืขื•ืคื” ื”ื ื›ื•ืช ืชื•ืœื™ื‘ื— ืื™ื ื•ื‘ (ISVs) ืื™ื™ืืžืฆืข ื”ื ื›ื•ืช ื™ืงืคืก ืจืคืกืž
.ืื”ืœืฉ ื”ืจื‘ื—ื‘ ืื™ืชืฉื•ืจืž ื‘ืฉื—ืž ื™ืกื›ื  ืœืฉ ืงื•ื—ืจืž ืœื•ื”ื™ื ืœ
ืชื•ื ื•ืจืชื™ื• ืชื•ื ื•ื›ืช
Intel AMT
ืชื•ื ื•ื›ืชืชื•ื ื•ืจืชื™
(Out-of-band (OOB ืชืฉื™ื’ื”ืœืขืคื”ื” ืชื›ืจืขืž ื‘ืฆืžื‘ ื•ื ืชืœืขืคื•ืž ืชื›ืจืขืžื” ืื ืชื•ืœืช ืืœืœ , ืชื•ืžืจื•ืคื˜ืœืค ืœืฉ ืงื•ื—ืจืž ืœื•ื”ื™ื  ืชืจืฉืคืืž
ืงื•ื—ืจืž ืชื•ืฉืฉื•ืืชื”ื• ืชื•ื™ืขื‘ ืŸื•ืจืชืคIT -ื” ืชืงืœื—ืž ืœืฉ ื™ื ื›ื˜ื” ืชื•ื•ืฆื” ืœืฉ ืชื•ืœื™ืขื™ื” ืชืœื“ื’ื” ืšื•ืช ,ื”ื“ื•ื‘ืขื” ืชื•ื ื—ืœื•ืฉื‘ ืื™ื‘ืฉื—ืžืœ ืขื™ื’ื”ืœ ืšืจื•ืฆื‘ ื™ืชื•ืขืžืฉืž ืื•ืฆืžืฆ
ืชื•ืžื•ื–ื™ ืชื•ืืจืชื”ืŸื•ืงื™ืช ื™ื ืžื– ืื•ืฆืžืฆื• ื”ืชื‘ืฉื” ืŸืžื– ืชื ื˜ืงื”
ื‘ืฉื—ืž ืชื•ืฉื™ืจื“
ืชื•ืฉื™ืจื“ .Intel Management Engine ืชื•ืขืฆืžืื‘ ืœื”ื•ื ืžื• ,Intelยฎ PCH ืชืžืจื•ืคื˜ืœืค/Intelยฎ 5 Series ืื™ื‘ื‘ืฉื” ืชื•ื›ืจืข ืชื—ืคืฉืžืž ื‘ื›ืจื•ืž ื”ื– ืšืžืกืžื‘ ืจื›ื–ื•ืžืฉ ื‘ืฉื—ืžื”
:ื—ื•ืงืœื” ื‘ืฉื—ืžื‘ ื•ืœื™ืขืคื”ืœื• Intel Management Engine ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื•ื‘ืงืœ ืŸืชื™ื ืฉ ื™ื ืคืœ ,ื”ืจื“ื’ื”ื• ื”ื ืงืชื”ืœ ืชื•ืฉืจื“ื  ืชื•ืื‘ื” ื”ื ื›ื•ืชื”ื• ื”ื—ืฉื•ืงื”
.GbE ื‘ื™ื›ืจ ืชื•ื ื•ืžืชื• Intel AMT 6.0 flash image integrating BIOS, Intel Management Engine ืืข ืชื ื›ื•ืชืž SPI Flash ืŸืงืชื”
.F12 ื˜ื™ืจืคืชืž MEBx ืชืจื“ื’ื”ืœ ืชืฉื’ืœ ื”ืœื•ื›ื™ ,ืจืฉืคื•ืืž Intel AMT ืืข BIOS ืชืจื“ื’ื”
ืชื ืขื•ื‘ืงืœื• (Intelยฎ MEI/SOL/LMS) ืื™ื ืงืชื” ื™ืœื”ื ืž ืŸื™ืงืชื”ืœ ืฉื™ ,Microsoft ื”ืœืขืคื” ืชื›ืจืขืžื‘ Intel Management Engine ืชื•ื ื•ื›ืช ืœื› ืชื ืจืฉืคืืœ ื™ื“ื›
.ื—ื•ืงืœื” ืชื›ืจืขืžื‘ ื”ื›ืœื”ื› ื•ืœืขืคื™ ืชื•ื ื•ื›ืชืฉ ื™ื“ื› ,ื—ื•ืงืœื” ืชื›ืจืขืžื‘ ืื”ืœืฉ ื”ืจื•ืฆืชื”
.Intel ื™ื“ื™-ืœืข ืŸืชื™ื  ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
.Dell ืœืฉ BIOS -ื‘ ืœื•ืœื›ื• Intel ื™ื“ื™-ืœืข โ„ขDell -ืœ ืงืคื•ืกืž , ื™ืœื ื•ื™ืฆืคื•ื ROM ืœื•ื“ื•ืž ,(Intelยฎ Management Engine BIOS Extension (MEBx :ื”ืจืขื”
.Dell ื™ื‘ืฉื—ืžืœ ืืืชื•ื” MEBx - ื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
*
Page 3
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ื”ืจื™ื”ืžื• ื”ื˜ื•ืฉืค ื”ื™ื•ื•ื—
:(Intelโ„ข Active Management Technology (Intel AMT ื‘ืฉื—ืžื‘ ืื™ื ื™ืžื– ืื™ืื‘ื” ืื™ืจืžื•ื—ื”
ืชื™ืจื•ืงืž ื”ื ืงืชื”
.Dell ื™ืœืขืคืž ืœืฉ ื™ืจื•ืงืž ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืฆืžื‘ ืงื•ื•ืฉืž Intel AMT 6.0
ื”ื ืงืชื”ื• ืจื™ื”ืž ืจื–ืข ืšื™ืจื“ืž
.Dell ืœืฉ ื”ื™ื’ื•ืœื•ื ื›ื˜ื” ืšื™ืจื“ืž ืœื ืจื•ืฉื™ืง ืืข Intel AMT ืชืจื™ืงืก
Dell ืœืฉ ื”ื™ื’ื•ืœื•ื ื›ื˜ื” ืšื™ืจื“ืž
.Intel AMT ืœืฉ ื”ื”ื•ื‘ื’ ื”ืžืจื‘ ื”ื›ื™ืžืชื• ื”ืงืคืกื ,ื”ืจื“ื’ื” ,ื”ืจื™ืงืก
ื™ื•ื‘ื™ื’ ืชื™ื™ื“ืž
.(ืื™ื‘ืืฉืžื” ืจื•ื˜ื™ืœืงืช) Resource CD -ื‘ ืื™ื ื™ืžื– ืื™ื™ื˜ื™ืจืง ืื™ื ืงืชื” ื™ืœื”ื ืžื• ื”ื—ืฉื•ืงืœ ืื™ื ืงืชื” ื™ืœื”ื ืž
.support.dell.com ืจืชืื‘ ืื™ื‘ืฉื—ืžื” ืœืฉ ืื™ื›ื™ืจื“ืžื” ืืข ื“ื—ื™ ืŸื™ืžื–ื• ื˜ื ืจื˜ื ื™ืื‘ ืืฆืžื  ืšื™ืจื“ืžื” . ืชื›ืจืขืžื” ืœื”ื ืžืœ ืšื™ืจื“ืžื‘ ืŸื™ื™ืข ,Intel AMT ืœืข ื˜ืจื•ืคืž ืขื“ื™ืž ืชืœื‘ืงืœ
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 4
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ื”ืœืขืคื” ื™ื‘ืฆืž
ืŸืคื•ืื‘ ื”ื‘ืœื•ืฉ ืื™ื‘ืฆืžื” ื™ื ืฉ ืœืฉ ืชื•ื™ืœื ื•ื™ืฆืงื ื•ืคื” ,ืชื™ื—ื›ื•ื ื” ื”ืกืจื’ื‘ .ื™ื ื•ื’ืจืื• (SMB) ืื™ื™ื ื•ื ื™ื‘ื• ืื™ื ื˜ืง ืื™ืงืกืข โ€“ ืื™ื™ืœื•ืขืคืช ืื™ื‘ืฆืž ื™ื ืฉื‘ ื•ื›ืžืช Intelยฎ AMT ืœืฉ ืชื•ืžื“ื•ืง ืชื•ืืกืจื’
.ืื“ื•ืงื” ื™ื ื•ื’ืจื ื‘ืฆืž ืœืฉ ืชื•ื™ืœื ื•ื™ืฆืงื ื•ืคื” ืชืœื‘ืงืชืžืฉ
Automatic Setup and -ื• (ืชื•ื™ื ื“ื™ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Manual Setup and Configuration : ืŸื” SMB ืชื•ื—ื•ืงืœ ืจื•ื‘ืข ืชื•ืฉื“ื—ื” ื”ืจื•ืฆืชื” ืชื•ื™ื•ืจืฉืคื
.(ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Configuration
Intel AMT 6.0 ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘
ืจื—ื•ืืž ื“ืขื•ืžื‘ ืจืฉืคื•ืืžืœ ืœืจื˜ื•ื ืž ืชื•ื ืฉืœ ืŸืชื™ื 
ืจืชื•ื™
ืจื—ื•ืืž ื“ืขื•ืžื‘ ืœืจื˜ื•ื ืžืœ ืจืฉืคื•ืืž ืชื•ื ืฉืœ ืŸืชื™ื 
ืจืชื•ื™
ื™ืคื•ืกืž ืืข ื”ื“ื•ื‘ืขืœ ืจืฉืคื•ืืžื› ืจื“ื’ื•ืž) ืœื˜ืจื•ื ืž
(ืื“ื•ืง ืจื•ื“ืž SMB
Intel AMT 5.0 ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘
ื™ื ื•ื’ืจื ื‘ืฆืžSMB ื‘ืฆืž
ยฎ
Intel
MEBx -ื‘ ื”ื ื•ื›ืชื” ืื ืจืฉืคื•ืืž
ืชืจืฉืคื•ืืž
Intel MEBx -ื‘ ื”ื ื•ื›ืชื” ืื ืจืฉืคื•ืืž
ืชืจืฉืคื•ืืž
.ืชื‘ืœื•ืฉืž ื”ืงื™ืคืจื’ ื‘ืฆืžื‘ ืชื•ื™ื”ืœ ื”ื›ื™ืจืฆ ืชื›ืจืขืžื” .ื”ืงื™ืคืจื’ืœ ื™ืžื™ื ืค CPU ืืข ืงืจ ืšืžืชื  KVM :ื”ืจืขื”
.ื”ืžืกื™ืกื” ืชื ื”ื ืฉ ,ื”ืกื™ื ื›ื” ืจื—ืืœ .admin ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก ืชื“ืœืงื”ื• F12 ืœืข ื”ืฉืงื” ื™ื“ื™-ืœืข Intel MEBx ืœื ื˜ื•ื•ื 
.(Intel ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”) Intel ME General Settings ื˜ื™ืจืคืชื” ืœื ื˜ื•ื•ื 
.(ืชืฉืจืœ ื”ืฉื™ื’ ืชืœืขืคื”) Activate Network Access ืจื—ื‘
ืœืจื˜ื•ื ืž
ืœืจื˜ื•ื ืž
:ืื™ืื‘ื” ืื™ื‘ืœืฉื” ืชื•ืขืฆืžืื‘ ืชื™ื ื“ื™ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืขืฆื‘
.ื”ื—ืฉื•ืงื• ืชื›ืจืขืž BIOS ืืข ื”ื ื•ืžืชื” ืœืฉ Flash ืขืฆื‘
IDER/SOL/KVM ืชืฉืจ ืงืฉืžืž
Legacy Redirection Mode
- ืื“ื•ืง ืจื•ื“ืœ ืฉื“ื—ืž ื‘ื•ืชื™ื  ื‘ืฆืž)
ื™ืจื•ื‘ื™ื— ืจื•ื‘ืข ื”ื—ืฉื•ืงืœ ื”ื ื–ืื”ื‘ ื˜ืœื•ืฉ
.ืจื•ืฉื™ืื” ืชืขื“ื•ื”ื‘ (ืŸื›) "Y" ืจื—ื‘
.Intel MEBx -ืž ืืฆ
ื”ืจื“ื’ื”
(TLS ื‘ืฆืž) TLS Modeืจืฉืคื•ืืžืœืจื˜ื•ื ืž
Web UIืœืจื˜ื•ื ืžืจืฉืคื•ืืžืจืฉืคื•ืืž
ืจืฉืคื•ืืž Redirection
(ืื™ืกื ื›ื  ืฉื“ื—ืž ื‘ื•ืชื™ื 
.Intel Activator ืชื•ืขืฆืžืื‘ ื”ืœืขืคื”ื” ืชื›ืจืขืž ืšืจื“ ื•ื ืื™ื™ื ื•ืฆื™ื— ืื™ืขืฆืžื ืšืจื“ ืื’ ื”ืœืขืคื”ื” ืชื ืขืฆื‘ืœ ืŸืชื™ื  :ื”ืจืขื”
ืฃื“ืœ ื”ืจื–ื—
ืŸื›ื•ืชื”
Page 5
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืชืจื™ืงืก
.Intelยฎ AMT ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืœ ืื™ืจื•ืฉืงื” ืื™ื‘ื•ืฉื— ืื™ื—ื ื•ืž ืœืฉ ื”ืžื™ืฉืจ ืŸืœื”ืœ
ืœืฉ ืงื•ื—ืจืž ืœื•ื”ื™ื  ืื™ืจืฉืคืืžื” ืชืฉืจ ืœืฉ ืื™ืจื˜ืžืจืคื• ืชื•ืืžืกื™ืก ,ืื™ืฉืžืชืฉืž ืชื•ืžืฉื‘ ,Intel AMT ื™ื“ื™-ืœืข ืœื”ื•ื ืžืฉ ,ื‘ืฉื—ืžื” ืชื ืกืœื›ืืžืฉ ืšื™ืœื”ืชื” โ€” ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”
.ื‘ืฉื—ืžื”
.Intel AMT ืœืฉ ื”ืงืคืกืื” ืชื ืื™ืœืฉืžื” ื™ืฉื™ืœืฉ ื“ืฆ ืœืฉ ืื•ืฉื™ื™ โ€” ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ืจื™ืฉ
.ืœื‘ื’ื•ืž ืŸืคื•ืื‘ ืงื•ื—ืจืž ื‘ืฉื—ืž ืœื•ื”ื™ื ืœ ื“ืขื•ื ืฉ ื˜ื ืจื˜ื ื™ื ืŸืคื“ืคื“ ืกืกื•ื‘ืž ืงืฉืžืž โ€” Intel AMT WebGUI
,ืœืœื› ืšืจื“ื‘ .ืชืฉืจ ืชื•ื™ืจื•ืฉื™ืง ืชืจืฉืคืืžื• Intel AMT ื‘ืฆืžืœ ื‘ืฉื—ืžื” ืชื ื”ื ื™ื›ืž Intel AMT ืชืจื“ื’ื” . ื‘ืฉื—ืžื‘ Intel AMT ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื•ื‘ืงืœื• ืจื™ื“ื’ื”ืœ ืšื™ืœืข ,ื•ื‘ ืฉื•ืžื™ืฉื” ื™ื ืคืœ
.ืชืฉืจ ืšืจื“ ื•ืชื•ืœื’ืœ ื”ืœื•ื›ื™ ืœื•ื”ื™ื  ืชื ื›ื•ืช , ืจืฉืคื•ืืž Intel AMT ืจืฉืื› .ื‘ืฉื—ืž ื™ื™ื—ื‘ ืชื—ื ืืขืค ืชืขืฆื•ื‘ืž ื•ื– ื”ืจื“ื’ื”
ืชืฉืจืœื• ืœืžืฉื— ืจื•ืงืžืœ ื‘ืฉื—ืžื” ืชื ืจื‘ื— , ืื™ื ื™ืžื– ืื™ืฉื•ืจื“ื” ืชืฉืจื” ื™ื‘ื™ื›ืจ ืœื› ืจืฉืื› . ื•ืžืฆืข ื•ืœืฉ ืชื•ืœื•ื›ื™ื” ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื‘ ืœื™ื—ืชื”ืœ ืŸื›ื•ืž ืื•ื” ,ื™ื ื•ื’ืจื ื‘ืฆืžื‘ Intel AMT ืชืจื“ื’ื” ืจื—ืืœ
ืœื•ื”ื™ื ืœ ืŸื›ื•ืž Intel AMT , ืŸื›ืž ืจื—ืืœ .ืšืจื•ื‘ืข ืšื™ืœื”ืชื” ืชื ืื™ืœืฉืž (ื™ืฉื™ืœืฉ ื“ืฆ ืœืฉ ืื•ืฉื™ื™) ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชื•ืจื™ืฉ .ื•ืžืฆืข ื•ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื‘ ืชื™ื˜ืžื•ื˜ื•ื ืœื™ื—ืชื™ Intel AMT - ื•
.ืšืœืฉ ืชื™ืงืกืขื” ื”ื‘ื™ื‘ืกื” ืจื•ื‘ืข ืฉืจื“ื ื› ื”ืจื•ืฆืชื” ืชื ืฉื“ื—ืž ืขื•ื‘ืงืœ ืšืชื•ืจืฉืคืื‘ ,ืจื“ื’ื•ืž Intel AMT ืจืฉืื› .ื“ื‘ืœื‘ ืชื•ืจื•ืคืก ืชื•ื™ื ืฉ ืชื›ืจื•ื ื•ื– ื”ืจื•ืฆืช ืชืขื™ื‘ืง ,ืœืœื› ืšืจื“ื‘ .ืงื•ื—ืจืž
Intel AMT Web ืชื•ืขืฆืžืื‘ ืฉื•ืžื™ืฉืœ ืŸื›ื•ืžื• ืชื™ื ื“ื™ ืจื“ื’ื•ืž ืื•ื” .ืชืฉืจื‘ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืœื™ืขืคื”ืœ ืšื™ืจืฆ ื•ื ื™ื ื‘ืฉื—ืžื” ,(ื™ื ื•ื ื™ื‘ ื•ื ืŸื˜ืง ืงืกืข) SMB ื‘ืฆืžื‘ Intel AMT ืชืจื“ื’ื” ืจื—ืืœ
.GUI
Intel AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ื™ื‘ืฆืž
ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ื™ื‘ืฆืž ื”ืฉื•ืœืฉืž ื“ื—ืื‘ ืชื•ื™ื”ืœ ืœื•ื›ื™ Intel AMT ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืž .(provisioning) ื”ืงืคืกื ืื’ ืชืืจืงื  Intel AMT ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืœืฉ ื”ืœื•ืขืคื”
:(SCS)
ืŸืจืฆื™ื” ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืฆืž
ื”ืจื“ื’ื” ื‘ืฆืž
ื”ืงืคืกื ื‘ืฆืž
ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืฆืžื‘ .ืœื•ื”ื™ื  ื™ืžื•ืฉื™ื™ืœ ืŸื™ื™ื“ืข ืชื•ื ื™ืžื– ืŸื ื™ื Intel AMT ืชื•ืœื•ื›ื™ื• ื•ืขื‘ืงื  ืืœ ืŸื™ื™ื“ืข ื”ื—ื˜ื‘ื ื™ืจื•ืฉื™ื ื•ื‘ืฉ ,ืชืจื“ื’ื•ืž ื”ืจื•ืฆืช ืœื› ืืœืœ ื‘ืฆืž ืื•ื” ืŸืจืฆื™ื” ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ื‘ืฆืž
.ืŸืจืฆื™ื” ืœืฉ ืŸื” Intel AMT ืชื•ืจื“ื’ื” ,ืŸืจืฆื™ื”
ื™ื•ื˜ื™ื‘ ,ืชื™ื ื•ืฉืืจ ืชื›ืจืขืž ืœื”ื ืž ืชืžืกื™ืก :(TLS) ื”ืจื•ื‘ืขืช ืชื‘ื›ืฉ ืชื—ื˜ื‘ืื• ืชืฉืจื‘ ื”ื“ื•ื‘ืข ืชื•ื“ื•ื ื™ื ื•ืฉืืจ ืขื“ื™ืžื‘ ืจื“ื’ื•ื” Intel AMT ื•ื‘ืฉ ,ืชื™ืงืœื— ืชืจื“ื’ื•ืž ื”ืจื•ืฆืช ืœืฉ ื‘ืฆืž ืื•ื” ื”ืจื“ื’ื” ื‘ืฆืž
.ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ืจื™ืฉืž ื™ื ื•ื’ืจื ื‘ืฆืž ืœืฉ ื”ืจื•ืฆืช ืชื•ืจื“ื’ื” ืœื‘ืงืœ ืŸื›ื•ืž ืื•ื” ,Intel AMT ืชืจื“ื’ื” ืจื—ืืœ .(PID) ื”ืงืคืกืื” ื”ื”ื–ืžื• (PPS) ื”ืงืคืกืืœ ื”ืžืกื™ืกื”
ืืข ื”ืขื‘ืงื  Intel AMT ืชืจื•ืฆืชื• ืœืžืฉื— ืชื›ื™ืจืฆ ืชื•ื™ื•ืจืฉืคื ืืข ื”ืขื‘ืงื  (Intel Management Engine (ME ืชืจื•ืฆืช ื•ื‘ืฉ ,ื™ืจืžื’ืœ ืชืจื“ื’ื•ืž ื”ืจื•ืฆืช ืœืฉ ื‘ืฆืž ืื•ื” ื”ืงืคืกื ื‘ืฆืž
.ืœื•ื”ื™ื ื” ื™ืžื•ืฉื™ื™ ืืข ื”ื™ืฆืงืืจื˜ื ื™ืืœ ืชื•ื ื›ื•ืž ืชื•ืœื•ื›ื™ื” ,Intel AMT ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืจื—ืืœ .Intel AMT ืชื•ืœื•ื›ื™ ืชื ืชื•ืœื™ืขืคืžืฉ ืชื•ืจื“ื’ื”ื”ื• ืื™ืจื•ืฉื™ื ,ื”ื—ื˜ื‘ืื” ืชื•ืจื“ื’ื”
ื”ืงืคืกื ืชื•ื˜ื™ืฉ
TLS-PKI
Intel ืจืฉืคื•ืืž ื‘ืฉื—ืžืœ ืชื—ื˜ื‘ื•ืืž ื”ืจื•ืฆื‘ ืจื‘ื—ืชื”ืœ ื™ื“ื› (TLS-PKI (Public Key Infrastructure ื™ืจื•ืฉื™ืื‘ ืฉืžืชืฉืž SCS - ื” ."ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง"ื› ืื’ ืขื•ื“ื™ TLS-PKI
:ืชื•ืื‘ื” ืื™ื›ืจื“ื‘ ืงื™ืคื”ืœ ืŸืชื™ื  ืจื•ืฉื™ืื” ืชื .AMT
.ื”ื– ืšืžืกืžื‘ืฉ MEBx -ื” ืงืฉืžืž ืฃื™ืขืกื‘ ื˜ืจื•ืคืžื› ,ื‘ืฉื—ืžื‘ ืฉืืจืž ืื™ืชื ื›ื•ืชืžืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ื™ืจื•ืฉื™ืืž ื“ื—ื ืชื•ืขืฆืžืื‘ ืจื‘ื—ืชื”ืœ ืœื•ื›ื™ SCS -ื”
ืฃื™ืขืกื‘ ื˜ืจื•ืคืžื› ,ื“ื—ื•ื™ืžื‘ ื˜ืžืจื•ืคืž USB ืขื‘ืฆื ืŸื ื•ื› ืืข ื™ื ื—ืœื•ืฉื” ื‘ืฉื—ืžื‘ ืจื•ืงื™ื‘ ื™ื“ื™-ืœืข AMT -ื” ื‘ืฉื—ืžื‘ ืกื•ืจืคืœ ืŸืชื™ื  ื•ืชื•ืืฉ , ืชื™ืฉื™ื ืืืชื•ืž ืจื•ืฉื™ื ืจื•ืฆื™ืœ ืœื•ื›ื™ SCS -ื”
.ื”ื– ืšืžืกืžื‘ืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชื•ืจื™ืฉ
- ืœืขืคืžื‘ ืชื™ืฉื™ื ืืืชื•ืž ื‘ื•ืœื™ืฉ) Custom Factory Integration ืšื™ืœื”ืช ืชื•ืขืฆืžืื‘ Dell ืœืขืคืžื‘ ืฉืืจืž ืชื ื›ื•ืชืฉ ืชื™ืฉื™ื ืืืชื•ืž ืจื•ืฉื™ืื‘ ืฉืžืชืฉื”ืœ ืœื•ื›ื™ SCS -ื” .(CFI
TLS-PSK
ืœื•ื›ื™ SCS -ื” .AMT - ื” ื‘ืฉื—ืž ืืข ื—ื˜ื‘ื•ืืž ืจื•ื‘ื™ื— ืจื•ืฆื™ืœ ื™ื“ื› (PSK (Pre-Shared Key ืชื•ื—ืชืคืžื‘ ืฉืžืชืฉืž SCS -ื” ."ืชื—ื ื”ืขื™ื’ื ื‘ ื”ืจื•ืฆืช ืชืขื™ื‘ืง"ื› ืื’ ืขื•ื“ื™ TLS-PSK
:ืื™ื›ืจื“ ื™ืชืฉืž ืชื—ืื‘ ื™ื ื—ืœื•ืฉื” ื‘ืฉื—ืžื‘ ืจื•ืงื™ื‘ ื™ื“ื™-ืœืข AMT - ื” ื‘ืฉื—ืžื‘ ืืชื•ื ืกื•ืจืคืœ ืŸืชื™ื  ืŸื›ืž ืจื—ืืœืฉ ,ืื™ื•ื•ืช 52 ืšืจื•ืื‘ ,ื”ืœื ืชื•ื—ืชืคืž ืจื•ืฆื™ืœ
.MEBx -ื‘ ื—ืชืคืžื” ืชื ืชื™ื ื“ื™ ื“ื™ืœืงื”ืœ ืŸืชื™ื 
ื—ืชืคืž ืจื–ื—ืืž AMT ื‘ืฉื—ืž ืœื› BIOS -ื” ืœื•ื—ืชื ืŸืžื–ื‘ , ืŸื›ืž ืจื—ืืœ .ื“ื—ื•ื™ืžื‘ ื˜ืžืจื•ืคืž USB ืขื‘ืฆื ืŸื ื•ื›ืœ ืืกื™ื ื›ื”ืœื• ืชื™ืฉื™ื ืื™ืžืืชื•ืž ืชื•ื—ืชืคืž ืœืฉ ื”ืžื™ืฉืจ ืจื•ืฆื™ืœ ืœื•ื›ื™ SCS -ื”
.ื”ื– ืšืžืกืžื‘ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชื•ืจื™ืฉ ืฃื™ืขืกื‘ ื˜ืจื•ืคืžื› , ื“ื—ื•ื™ืžื‘ ื˜ืžืจื•ืคืžื” USB ืขื‘ืฆืื” ืŸื ื•ื›ืž ืชื™ืฉื™ื ืืืชื•ืž
Page 6
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 7
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
MEBx ืชื•ืจื“ื’ื” ืœืฉ ื”ืจื™ืงืก
ืชืžืจื•ืคื˜ืœืค ื“ื•ืงืคืช ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืืฉืœ ,ื”ืžืจื•ืคื˜ืœืคื” ืชืžืจื‘ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ื™ื•ืจืฉืคื ืงืคืกืž (Intelยฎ Management Engine BIOS Extension (MEBx -ื”
.ืœืžืฉื— ืชื›ื™ืจืฆ ืชื•ืจื•ืฆืช ืชืจื“ื’ื”ื• ืชื•ื“ื“ื•ื‘ ืชื•ื ื•ื›ืช ืœื•ืจื˜ื ื• ืจื•ืฉืคื ืชื•ืœืœื•ื› ืชื•ื™ื•ืจืฉืคืื” .(Management Engine (ME
.MEBx ืชืจื•ืฆืช ืœืฉ , ืชื•ืžื™ื™ืง ืื , ืชื•ืœื‘ื’ืžื• ืชื•ื™ื•ืจืฉืคื ืชื•ื“ื•ื ืื™ื˜ืจืค ืงืคืกืž ื”ื– ืฃื™ืขืก
ืื ,ืŸื›ืœ .MEBx -ืž ื”ืื™ืฆื™ื” ืจื—ืืœ ืงืจ ME -ื” ืœืฉ (NVM) ืฃื™ื“ื  ืืœื” ืŸื•ืจื›ื™ื–ื‘ ืื™ืจืžืฉื  ืื” .MEBx -ื‘ ืื™ื ืกื—ื•ืืž ืื ื™ื ME -ื” ืœืฉ ื”ืจื•ืฆืชื” ืชื•ืจื“ื’ื”ื‘ ืื™ื™ื•ื ื™ืฉื” :ื”ืจืขื”
.ME -ื” ืœืฉ ืฃื™ื“ื  ืืœื” ืŸื•ืจื›ื™ื–ื‘ ืื™ืจืžืฉื  ืื ื™ื ื”ื“ื•ืงื  ื”ืชื•ืืœ ื“ืข ืชืขืฆื™ื‘ืฉ ืื™ื™ื•ื ื™ืฉื” ,ืกืจื•ืง MEBx -ื”
MEBx ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงืœ ืฉืžืชืฉืžื” ืงืฉืžืžืœ ื”ืฉื™ื’
:ืื™ืื‘ื” ืื™ื‘ืœืฉื” ืชื•ืขืฆืžืื‘ ื‘ืฉื—ืžื‘ MEBx ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงืœ ืฉืžืชืฉืžื” ืงืฉืžืžืœ ืชืฉื’ืœ ืŸืชื™ื 
.ื‘ืฉื—ืžื” ืชื (ืฉื“ื—ืž ืœืขืคื” ื•ื) ืœืขืคื”
.MEBx ืจื—ื‘ื• <F12> ืœืข ื“ื™ื™ืž ืฉืงื” ,ืœื•ื—ื›ื” โ„ขDELL ื•ื’ื•ืœื” ืขื™ืคื•ืž ืจืฉืื›
ืชื ื”ื‘ื› , ืŸื›ืž ืจื—ืืœ .
ืจื•ื—ื‘ืœ ื™ื“ื› ื”ื˜ืžืœื• ื”ืœืขืžืœ ืื™ืฆื—ื” ื™ืฉืงืžื‘ ืฉืžืชืฉื” ,ื˜ื™ืจืคืชื” ืขื™ืคื•ืž ืจืฉืื› .ื™ืžืขืค-ื“ื—ื” ืœื•ื—ืชืื” ื˜ื™ืจืคืชื‘ <F12> ืœืข ื”ืฉืงื” ืื™ื” MEBx -ื” ืœื ืชืฉื’ืœ ืชืคืกื•ื  ื”ื˜ื™ืฉ :ื”ืจืขื”
ยฎ
Microsoftยฎ Windows ืœืฉ ื”ื“ื•ื‘ืขื” ืŸื—ืœื•ืฉ ืขื™ืคื•ื™ ืจืฉื ื“ืข ืŸื™ืชืžื”ืœ ืšืฉืžื” ,ืขื™ืคื•ืž ื”ืœืขืคื”ื” ืชื›ืจืขืž ืœืฉ ื•ื’ื•ืœื”ื• ื™ื“ืž ื‘ืจ ืŸืžื– ืŸื™ืชืžืž ื”ืชื ืื
.ื‘ื•ืฉ ื”ืกื ื• ื‘ืฉื—ืžื”
.ื”ืชื•ื ืฉืœ ืฉืžืชืฉืžื” ืชื•ืจืฉืคืื‘ื• ,'admin' ืื™ื” ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก .<Enter> ืฉืงื” .ME ืœืฉ ื”ืžืกื™ืกื” ืชื ื“ืœืงื”
.<Enter> ืฉืงื” .(Intel Management Engine BIOS Extension (MEBx ืชื•ืจืฉืคืื‘
.ืŸืœื”ืœ ื’ืฆื•ืžื› ,ืขื™ืคื•ืž MEBx - ื” ืšืกืž
Page 8
:ื”ืจื™ื—ื‘ืœ ืชื•ื™ืฆืงื ื•ืค ืฉื•ืœืฉ ืชื•ื’ืฆื•ืž ื™ืฉืืจื” ื˜ื™ืจืคืชื‘
(Intel ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”) Intel ME General Settings
(Intel AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel AMT Configuration
(ื”ืื™ืฆื™) Exit
.ื”ืจืกื—ื” ื”ื ื•ื›ืชื‘ ืชื›ืžื•ืช ืชื›ืจืขืžื”ืฉ ืื“ื• ,ืชื•ืขื™ืคื•ืž ืืœ ื•ืœื ืชื•ื™ืฆืงื ื•ืคืž ืจืชื•ื™ ื•ื ืชื—ื ืื .ื•ื”ื•ื–ืฉ ืชื•ื™ื•ืจืฉืคืื” ืงืจ ื•ื’ืฆื•ื™ Intel MEBx -ื‘ :ื”ืจืขื”
Intel ME ืœืฉ ื”ืžืกื™ืกื” ื™ื•ื ื™ืฉ
.ื™ื”ืฉืœื› ื”ื ื•ื›ืช ืชืจื•ืฆืช ืœืฉ ืชื•ื™ื•ืจืฉืคื ื™ื•ื ื™ืฉ ื™ื ืคืœ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก ืชื ืชื•ื ืฉืœ ืšื™ืœืข .ื•ืกืจืคื  ื”ืชืข ื”ื–ืฉ ืชื•ืžืจื•ืคื˜ืœืคื” ืœื›ื‘ ื”ื”ื– ืื™ื”ื• admin ืื™ื” ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก
.ื™ื”ืฉืœื› ื”ื™ืฆืงื ื•ืคื‘ ืฉืžืชืฉื”ืœ ืœื›ื•ื™ืฉ ื™ื ืคืœ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก ืชื ืชื•ื ืฉืœ ื•ื™ืœืข , ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก ืืข Intel MEBx ืœืฉ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ื˜ื™ืจืคืชืœ IT ืœื”ื ืž ืœืฉ ื”ื ื•ืฉืืจื” ื”ืกื™ื ื›ื‘
:ืื™ืื‘ื” ืื™ื‘ื™ื›ืจื” ืชื ืœื•ืœื›ืœ ื”ืžืกื™ืกื” ืœืข
32 - ืž ืจืชื•ื™ ืืœ ,ืื™ื•ื•ืช ื”ื ื•ืžืฉ
ืชื—ื ืชื™ืฉื™ืจ ืชื•ื
ืชื—ื ื”ื ื˜ืง ืชื•ื
ืจืคืกืž
(.ืื™ื•ื•ืชื”ื• ," ,: ืœืœื•ื› ืืœ ; ื•ื ,$ ,! ืŸื•ื’ื› ,(ื™ืจืžื•ื ืืคืœื ืืœ) ื“ื—ื•ื™ืž ื•ืช
.ื”ืžืกื™ืกื” ืชื•ื‘ื›ืจื•ืžืœ ืื™ืคื™ืกื•ืž ืื ื™ื ืšื ,ื”ืžืกื™ืกืœ ืื™ืคืงืช ืื™ื•ื•ืช ืื” ื—ื•ื•ืจื• (_) ืŸื•ืชื—ืช ื•ืง :ื”ืจืขื”
.Intel ื™ื“ื™-ืœืข ืŸืชื™ื  ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
*
Page 9
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”
:ื”ืœื ืื™ื‘ืœืฉ ืขืฆื‘ ,Intelยฎ Management Engine (ME) Platform Configuration ืฃื“ื” ืœื ื˜ื•ื•ื ืœ ื™ื“ื›
ืฉืงื” .(Intel ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”) Intel ME General Settings ืจื—ื‘ (Management Engine BIOS Extension (MEBx ืœืฉ ื™ืฉืืจื” ื˜ื™ืจืคืชื‘
.<Enter>
)ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื” ืœืฉ ื”ืจื•ืฆืช ืฉื›ื•ืจ( Acquiring General Settings configuration
ืŸื•ื’ื› ,Intel ME ืœืฉ ืชื™ืคื™ืฆืคืก ืชื•ื™ืœื ื•ื™ืฆืงื ื•ืค ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื•ื‘ืงืœ IT -ื” ืœื”ื ืžืœ ืจืฉืคืืž ื”ื– ืฃื“ .(ME ืœืฉ ืชื™ืœืœื› ื”ืจื•ืฆืช) ME General Configuration ืฃื“ื” ืขื™ืคื•ืž
.ืื™ื ื•ืฉื” ืื™ืคื™ืขืกืœ ืื™ืจื™ื”ืž ืื™ืจื•ืฉื™ืง ืŸืœื”ืœ .ื”ืžื•ื“ื›ื• ืœืžืฉื— ืชื›ื™ืจืฆ ืชื•ื™ื•ืจืฉืคื ,ื”ืžืกื™ืก
(Intel ME ื‘ืฆืž ืชืจืงื‘) Intel ME State Control
(Intel ME ืชืžืกื™ืก ื™ื•ื ื™ืฉ ) Change Intel ME Password
(ื”ืžืกื™ืก ืชื•ื™ื ื™ื“ืž) Password Policy
(ืชืฉืจ ืชืจื“ื’ื”) Network Setup
(ืชืฉืจ ืืฉ ืชื•ืจื“ื’ื”) Network Name Settings
(ื—ืจืืž ืืฉ) Host Name
(ืื•ื—ืช ืืฉ) Domain Name
(ื™ืžื ื™ื“ Dynamic DNS (DNS
(ื™ืชืคื•ืงืช ืŸื•ื›ื“ืข ื—ื•ื•ืจืž) Periodic Update Interval
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(TCP/IP ืชื•ืจื“ื’ื”) TCP/IP Settings
(ื˜ื•ื•ื—ืž LAN IPv4 ืชืจื•ืฆืช) Wired LAN IPv4 Configuration
(DHCP ื‘ืฆืž) DHCP Mode
(IPv4 ืชื‘ื•ืชื›) IPv4 Address
(ืœื“ื—ืž ืชืจื™ืจื‘ ืจืขืฉ ืชื‘ื•ืชื›) Default Gateway Address
(ืชืคื“ืขื•ืž DNS ืชื‘ื•ืชื›) Preferred DNS Address
(ืชื™ืคื•ืœื— DNS ืชื‘ื•ืชื›) Alternate DNS Address
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ื˜ื•ื•ื—ืž LAN IPv6 ืชืจื•ืฆืช) Wired LAN IPv6 Configuration
(IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) IPv6 feature Selection
(IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type
(IPv6 ืชื‘ื•ืชื›) IPv6 Address
(IPv6 ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืชื ) IPv6 Default Router
(ืชืคื“ืขื•ืž DNS IPv6 ืชื‘ื•ืชื›) Preferred DNS IPv6 Address
(ืชื™ืคื•ืœื— DNS IPv6 ืชื‘ื•ืชื›) Alternate DNS IPv6 Address
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ื™ื˜ื•ื—ืœื LAN IPv6 ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Wireless LAN IPv6 Configuration
(IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) IPv6 feature Selection
(IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ื”ืจื•ืฆืช ืืœืœ ืชืฉืจืœ ื”ืฉื™ื’) Unconfigure Network Access
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Remote Setup And Configuration
(ื™ื—ื›ื•ื  ื”ืงืคืกื ื‘ืฆืž) Current Provisioning Mode
(ื”ืงืคืกื ืชืžื•ืฉืจ) Provisioning Record
(ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชืœื—ืชื”) Start Configuration
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(IPv4/IPv6 ื”ืงืคืกื ืชืจืฉ) Provisioning Server IPv4/IPv6
(FQDN ื”ืงืคืกื ืชืจืฉ) Provisioning Server FQDN
(PPS - ื• PID ืชืจื“ื’ื”) Set PID and PPS
(PPS - ื• PID ืชืงื™ื—ืž) Deleting PID and PPS
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Remote Configuration
PKI DNS Suffix
(Hash ื™ื’ื•ืก ืœื•ื”ื™ื ) Manage Hashes
(ืชื™ืฉื™ื ืืืชื•ืž Hash ืชืคืกื•ื”) Adding Customized Hash
(Hash ืชืงื™ื—ืž) Deleting a Hash
:ืขื™ืคื•ืช ื”ืื‘ื” ื”ืขื“ื•ื”ื”
FQDN
TTL
TLS PSK
TLS PKI
Page 10
(ืœื™ืขืคื” ื‘ืฆืžื” ื™ื•ื ื™ืฉ) Changing the Active State
(ืจื•ืฉื™ื Hash ืชื’ืฆื”) Viewing a Certificate Hash
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ื™ืžื•ืงืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Local FW Update
(ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Secure FW Update
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข ืชื•ืจื“ื’ื” ) FW Update Settings
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(PRTC ืชืจื“ื’ื”) Set PRTC
(ืœืžืฉื— ืชื›ื™ืจืฆ ืชืจืงื‘) Power Control
Intel ME ON in Host Sleep
(ืงืจืก ื‘ืฆืžื‘ ืŸืžื– ืงืกืค) Idle Time Out
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(Intel ME ื‘ืฆืž ืชืจืงื‘) Intel ME State Control
ME ื˜ื™ืจืคืชื” ,(ME ืชืžืจื•ืคื˜ืœืค ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) ME Platform Configuration ื˜ื™ืจืคืชื‘ ืชืจื—ื‘ื  (ME ื‘ืฆืž ืชืจืงื‘) ME State Control ืชื•ืจืฉืคืื” ืจืฉืื›
.ืื™ื’ืื‘ื” ืจื•ืชื™ื ืšื™ืœื”ืช ืื•ื™ืกืœ ื“ืข ,ืชื™ืฉืืจื” ื”ืžืจื•ืคื˜ืœืคื”ืž ME -ื” ื‘ืฉื—ืž ืชื ื“ื“ื•ื‘ืœ ื™ื“ื› ME ืชื ืœืจื˜ื ืœ ืšืชื•ืจืฉืคืื‘ .ืขื™ืคื•ืž (ME ื‘ืฆืž ืชืจืงื‘) State Control
ืขื•ืฆื™ื‘ ืชื ืขื ื•ืž MEBx ืšืจื“ Intel ME ืœื•ืจื˜ื  .ืื™ื’ืื‘ ืจื•ืชื™ื ืชืจื˜ืžืœ Intel ME ืชื ืœืจื˜ื ืœ ืชืœื•ื›ื™ื” ืชื ืชืงืคืกืž (ืœืจื˜ื•ื ืž/ืจืฉืคื•ืืž) Intel ME State Control ืชื•ืจืฉืคืื”
.ืชื™ืœืื™ืฆื ื˜ื•ืคื” ื”ื™ืขื‘ื› Intel ME ืชื ืœื•ืกืคืœ IT -ื” ื™ืื ื›ื˜ืœ ืชืจืฉืคืืž ื•ื– ืชื•ืจืฉืคื .Intel ME ืœืฉ ื“ื•ืงื”
ME Platform State Control
ืชื•ืจืฉืคืืจื•ืื™ืช
(ืจืฉืคื•ืืž) Enabledื”ืžืจื•ืคื˜ืœืคื‘ Management Engine -ื” ืชื ืจืฉืคืืž (ืœืจื˜ื•ื ืž) Disabledื”ืžืจื•ืคื˜ืœืคื‘ Management Engine -ื” ืชื ืœืจื˜ื ืž
ื”ืจื•ื‘ืขืช ืŸื™ื ืชื›ืจืขืžืœืฉ ืšื› ,Intel ME ืœื•ื—ืชื ืœืฉ ืื“ืงื•ืž ื‘ืœืฉื‘ Intel ME ืœืฉ ื“ื•ืงื” ืชืจื™ืฆืขืœ ืืจื•ื’ ืื•ื” . ืื•ืฉื™ื™ื” ืชื ืชืžืื‘ ืœืจื˜ื ืž ื•ื ื™ื Intel ME ืœืฉ "ืœื•ืจื˜ื " :ื”ืจืขื”
ื™ืื ื›ื˜ืœ ืจืฉืคืืž ื”ื– ืœื•ืจื˜ื  .ื“ื‘ืœื‘ ืื™ื’ืื‘ ืจื•ืชื™ื ืชื•ืจื˜ืžืœ ื“ืขื•ื™ืžื• ,ืชื›ืžืชื  ื”ืจื•ืฆืช ื•ื ื™ื ืื’ื• ืœื™ื’ืจ ื”ืœื•ืขืค ื‘ืฆืž ืชื•ื™ื”ืœ ื“ืขื•ื™ืž ื”ื– ืŸื™ื .ืื™ืงื™ืคืื”ืž ื“ื—ื ืฃืื‘ Intel ME -ื‘ ื”ืจื•ืงืžืฉ
.Intel ME ืœืฉ ื”ืขืจืคื” ืืœืœ ,ืชื›ืจืขืžื‘ ืชื•ื™ืขื‘ ืจืชืืœ IT
Page 11
(Intel ME ืชืžืกื™ืก ื™ื•ื ื™ืฉ) Change Intel ME Password
Intel ืœืฉ ื”ืžืกื™ืกืœ ื”ืฉื™ืจื“ื” ื™ื•ื ื™ืฉ ืฃื™ืขืกื‘ ืื™ื˜ืจื•ืคืžื” , ื”ืžืกื™ืกืœ ืขื’ื•ื ื‘ ืชื•ืœื‘ื’ื”ืœื• ืชื•ื™ื ื™ื“ืžืœ ื‘ืœ ืื™ืฉ) ื”ืฉื“ื—ื” ื”ืžืกื™ืกื” ืชื ื“ืœืงื” ,ื”ืฉื“ื— ื”ืžืกื™ืก ืŸื™ื–ื”ืœ Intel ME ืœืฉ ื”ื™ื—ื ื”ื‘
.ื”ืฉื“ื—ื” ื”ืžืกื™ืกื” ืชื ื‘ื•ืฉ ื“ืœืงื” ,ื”ืžืกื™ืกื” ืชื•ืžื™ืืœ ื”ื™ื—ื ื”ื‘
.(ME
(ื”ืžืกื™ืก ืชื•ื™ื ื™ื“ืž) Password Policy
.ืชืฉืจื” ืšืจื“ Intel MEBx ืชืžืกื™ืก ืชื ืชื•ื ืฉืœ ื”ืฉืจื•ืž ืฉืžืชืฉืžื” ื™ืชืž ืชืขื‘ื•ืง ื•ื– ืชื•ืจืฉืคื
.Intel MEBx ืœืฉ ืฉืžืชืฉืžื” ืงืฉืžืž ืšืจื“ ื“ื™ืžืช ืชื•ื ืฉืœ ืŸืชื™ื  Intel MEBx ืชืžืกื™ืก ืชื :ื”ืจืขื”
Page 12
.ื•ืœื ืชื•ื™ื•ืจืฉืคื ืœืฉ ืจื•ืื™ืช
ืืจื˜ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก ืื ,ืชืฉืจื” ืงืฉืžืž ืšืจื“ Intel MEBx ืœืฉ ื”ืžืกื™ืกื” ืชื ืชื•ื ืฉืœ ืŸืชื™ื  โ€” (ื“ื‘ืœื‘ ืœื“ื—ืž ืชืจื™ืจื‘ ืชืžืกื™ืก) Default Password Only
.ื”ืชื ื•ืฉ
ื”ืจื“ื’ื”ื” ืšื™ืœื”ืช ืŸืžื–ื‘ ืชืฉืจื” ืงืฉืžืž ืšืจื“ Intel MEBx ืœืฉ ื”ืžืกื™ืกื” ืชื ืชื•ื ืฉืœ ืŸืชื™ื  โ€” (ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืšืœื”ืžื‘ ) During Setup and Configuration
.ืชืฉืจื” ืงืฉืžืž ืšืจื“ Intel MEBx ืชืžืกื™ืก ืชื ืชื•ื ืฉืœ ืŸืชื™ื  ืืœ ,ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืšื™ืœื”ืช ืชืžืœืฉื” ืืข .ืจื—ื ืŸืžื–ื‘ ืืœ ืšื ,ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื•
.ืชืข ืœื›ื‘ ืชืฉืจื” ืงืฉืžืž ืšืจื“ Intel MEBx ืœืฉ ื”ืžืกื™ืกื” ืชื ืชื•ื ืฉืœ ืŸืชื™ื  โ€” (ืชืข ืœื›ื‘) Anytime
(ืชืฉืจ ืชืจื“ื’ื”) Network Setup
.Enter ืฉืงื”ื• (ืชืฉืจ ืชืจื“ื’ื”) Network Setup ืจื—ื‘ ,(Intel ME ืชืžืจื•ืคื˜ืœืค ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.(Intel ME ืœืฉ ืชืฉืจ ืชืจื“ื’ื”) Intel ME Network Setup ืฃื“ืœ ื”ื ืชืฉืž Intel ME Platform Configuration ื˜ื™ืจืคืชื”
(ืชืฉืจ ืืฉ ืชื•ืจื“ื’ื”) Network Name Settings
.Enter ืฉืงื”ื• Intel ME Network Name Settings ืจื—ื‘ ,(Intel ME ืœืฉ ืชืฉืจ ืืฉ ืชื•ืจื“ื’ื”) Intel ME Network Name Settings ืชื•ืจืฉืคืื‘
Page 13
(ื—ืจืืž ืืฉ) Host Name .1
.Enter ืฉืงื”ื• (ื—ืจืืž ืืฉ) Host Name ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
.Intel AMT -ื” ืชืจืฉืคื•ืืž ืชื›ืจืขืžื” ืœืฉ ื—ืจืืžื” ืืฉ ื”ื™ื”ื™ ื”ื– .Intel AMT - ื” ืืข ื‘ืฉื—ืžืœ ื—ืจืืž ืืฉ ืชื•ืฆืงื”ืœ ืŸืชื™ื 
(ืื•ื—ืช ืืฉ) Domain Name .2
Page 14
.Enter ืฉืงื”ื• ( ืื•ื—ืช ืืฉ) Domain Name ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
.Intel AMT -ื” ืืข ื‘ืฉื—ืžืœ ืื•ื—ืช ืืฉ ืชื•ืฆืงื”ืœ ืŸืชื™ื 
.Intel ME -ืœ ื™ื“ื•ืขื™ื™ ื•ื ,ื”ืœืขืคื”ื” ืชื›ืจืขืž ืœืฉ ื‘ืฉื—ืžื” ืืฉืœ ื”ื”ื–ื• ื—ืจืืžื”
(ื™ื“ื•ืขื™ื™/ืฃืชื•ืฉืž Shared/Dedicated FQDN (FQDN .3
.Enter ืฉืงื”ื• (ื™ื“ื•ืขื™ื™ /ืฃืชื•ืฉืž Shared/Dedicated FQDN (FQDN ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
ืืข ืฃืชื•ืฉืž ื”ื™ื”ื™ ("HostName.DomainName" , ืจืžื•ืœื›) Intel ME ืœืฉ (FQDN - ืืœืž ืื•ื—ืช ืืฉ) Fully Qualified Domain Name -ื” ืื ืชืขื‘ื•ืง ื•ื– ื”ืจื“ื’ื”
Page 15
ืชื•ืจืฉืคืืจื•ืื™ืช
(ื™ื“ื•ืขื™ื™) DedicatedME - ืœ ื™ื“ื•ืขื™ื™ FQDN ืื•ื—ืชื” ืืฉ
(ืฃืชื•ืฉืž) Sharedื—ืจืืžื” ืืข ืฃืชื•ืฉืž FQDN ืื•ื—ืชื” ืืฉ
(ื™ืžื ื™ื“ DNS ืŸื•ื›ื“ืข) Dynamic DNS Update .4
.Enter ืฉืงื”ื• (ื™ืžื ื™ื“ DNS ืŸื•ื›ื“ืข) Dynamic DNS Update ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
Dynamic ืœื•ืงื•ื˜ื•ืจืค ืชื•ืขืฆืžืื‘ DNS -ื‘ FQDN -ื” ืชืื• ื”ืœืฉ IP -ื” ืชื•ื‘ื•ืชื› ืชื ื”ืœื™ืขืค ื”ืจื•ืฆื‘ ืื•ืฉืจืœ ื”ืกื ืช ื”ื—ืฉื•ืงื” ,ืชืจืฉืคื•ืืž Dynamic DNS Update ืชื•ืจืฉืคืื” ืื
ืœืฉ ื”ืจื•ืฆืชื” ืื .ื™ืžื ื™ื“ DNS ืŸื•ื›ื“ืข ื•ื DHCP option 81 ืชื•ืขืฆืžืื‘ DNS -ื” ืชื ืŸื›ื“ืขืœ ื”ืกื ืช ืืœ ื”ื—ืฉื•ืงื” ,ืชืœืจื˜ื•ื ืž DDNS Update ืชื•ืจืฉืคืื” ืื .DNS Update
DHCP -ื‘ ื”ืฉืžืชืฉื” ื”ื—ืฉื•ืงื” ื•ื‘ืฉ , ื”ืœืฉ ืŸืฉื™ื” ืื•ืฉื™ื™ื‘ ืฉืžืชืฉืช ื”ื—ืฉื•ืงื” ,ืฉืžืชืฉืžื” ื™ื“ื™-ืœืข ืœืœื› ืชืจื“ื’ื•ืž ื”ื ื™ื (ืœืจื˜ื•ื ืž ื•ื ืจืฉืคื•ืืž) (DDNS ืŸื•ื›ื“ืข) DDNS Update ื‘ืฆืž
,Dynamic DNS Update ืจื•ื‘ืข (ืจืฉืคื•ืืž) "Enabled" ืจื•ื—ื‘ืœ ื™ื“ื› .DDNS ืŸื•ื›ื“ืขื” ืœื•ืงื•ื˜ื•ืจืค ืชื•ืขืฆืžืื‘ ืชื•ืจื™ืฉื™ DNS -ื” ืชื ื”ื ื›ื“ืข ืืœ ืšื ,DNS ืื•ืฉื™ืจืœ option 81
.ืื•ื—ืชื” ืืฉื• ื—ืจืืžื” ืืฉ ืชื ืจื™ื“ื’ื”ืœ ื”ื‘ื•ื—
ืชื•ืจืฉืคืืจื•ืื™ืช
ื”ื—ืฉื•ืงื‘ Dynamic DNS Update Client -ื”
.ืจืฉืคื•ืืž
.ืœืจื˜ื•ื ืž ื”ื—ืฉื•ืงื‘ Dynamic DNS Update Client -ื”
Enabled
(ืจืฉืคื•ืืž)
Disabled
(ืœืจื˜ื•ื ืž)
(ื™ืชืคื•ืงืช ืŸื•ื›ื“ืข ื—ื•ื•ืจืž) Periodic Update Interval .5
.Enter ืฉืงื”ื• (ื™ืชืคื•ืงืช ืŸื•ื›ื“ืข ื—ื•ื•ืจืž) Periodic Update Interval ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
.Enter ืฉืงื”ื• , ื™ื•ืฆืจื” ื—ื•ื•ืจืžื” ืชื ื“ืœืงื”
Page 16
.ืชืจืฉืคื•ืืž Dynamic DNS Update ืชื•ืจืฉืคืื” ืจืฉืื› ืงืจ ื”ื ื™ืžื– ื•ื– ืชื•ืจืฉืคื :ื”ืจืขื”
ืšืจืข .ืชื•ืงื“ื‘ ืŸื” ืชื•ื“ื™ื—ื™ื” .ืŸื•ื’ืจืื” ืœืฉ DNS -ื” "ื™ื•ืงื™ื " ืชื•ื™ื ื™ื“ืžืœ ืืืชื”ื‘ ืจื“ื’ื•ื™ ืŸืžื–ื” ื—ื•ื•ืจืž .ืื™ื™ืชืคื•ืงืช ืื™ื ื•ื›ื“ืข ื—ืœืฉื™ ื”ื—ืฉื•ืงื” ืœืฉ DDNS -ื” ืŸื•ื›ื“ืข ื—ื•ืงืœ ื•ื‘ืฉ ืŸืžื–ื” ื—ื•ื•ืจืž ืชืจื“ื’ื”
.ืชื•ืงื“ 1440 - ืชื•ืขืฉ 24 ืื•ื” ื”ื– ืŸื™ื™ืคืืž ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืšืจืข .ืจืชื•ื™ ื•ื ืชื•ืงื“ 20 ืชื•ื™ื”ืœ ืšื™ืจืฆ ืจื“ื’ื•ืžื” ืšืจืขื” .ื™ืชืคื•ืงืช ืŸื•ื›ื“ืข ืœืจื˜ื ืž 0 ืœืฉ
TTL .6
.Enter ืฉืงื”ื• TTL ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
.Enter ืฉืงื”ื• (ืชื•ื™ื ืฉื‘) ื™ื•ืฆืจื” ืŸืžื–ื” ืชื ื“ืœืงื”
Page 17
.ืชืจืฉืคื•ืืž Dynamic DNS Update ืชื•ืจืฉืคืื” ืจืฉืื› ืงืจ ื”ื ื™ืžื– ื•ื– ืชื•ืจืฉืคื :ื”ืจืขื”
,ื”ืœืฉ ื™ื ื•ืฉืืจื” ืœื“ื—ืžื” ืชืจื™ืจื‘ ืšืจืขื‘ ืฉืžืชืฉืช ื”ื—ืฉื•ืงื” ,ืกืคืื› ืจื“ื’ื•ืช ื•ื– ื”ืจื“ื’ื” ืื .ืกืคืืž ืœื•ื“ื’ ืชื•ื™ื”ืœ ืšื™ืจืฆ ื”ื– ืจืคืกืž .ืชื•ื™ื ืฉื‘ TTL - ื” ืŸืžื– ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื•ื‘ืงืœ ืชืจืฉืคืืž ื•ื– ื”ืจื“ื’ื”
.DHCP ืจื•ื‘ืข ื”ืจื™ื›ื—ื” ืŸืžื–ืž 1/3 ื•ื ืชื•ืงื“ 15 ืื•ื”ืฉ
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu .7
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel ME Network Name Settings ืชื—ืช
.(Intel ืชืฉืจ ืชืจื“ื’ื”) Intel Network Setup ืฃื“ืœ ื”ื ืชืฉืž Intel ME Network Name Settings ื˜ื™ืจืคืชื”
(TCP/IP ืชื•ืจื“ื’ื”) TCP/IP Settings
.Enter ืฉืงื”ื• (TCP/IP ืชื•ืจื“ื’ื”) TCP/IP Settings ืจื—ื‘ (ืชืฉืจ ืชืจื“ื’ื”) Network Setup ื˜ื™ืจืคืชื‘
.(Intel ืชืฉืจ ืชืจื“ื’ื”) Intel Network Setup ืฃื“ืœ ื”ื ืชืฉืž Intel ME Network Name Settings ื˜ื™ืจืคืชื”
.(TCP/IP ืชื•ืจื“ื’ื”) TCP/IP Settings ืฃื“ืœ ื”ื ืชืฉืž Intel Network Setup ื˜ื™ืจืคืชื”
ืชื ืœื‘ืงืœ ื™ื“ื› ื˜ื•ื—ืœืื” ืงืฉืžืž ืชื ืฉืคื—ืž ืื•ื” ,ื—ืชืคื  Intel MEBx -ื” ืจืฉืื› .ื™ื˜ื•ื—ืœื IPv4 ืจื•ื‘ืข ืืœ ืšื ,ื™ื˜ื•ื—ืœื IPv6 ืจื•ื‘ืข ืื™ื˜ื™ืจืคืช ืœืœื•ื› Intel MEBx -ื” :ื”ืจืขื”
.ืืœ ื•ื ื™ื˜ื•ื—ืœืื” IPv6 -ื” ื˜ื™ืจืคืช ืชื ื’ื™ืฆื”ืœ ืื ื”ื˜ืœื—ื”ื”
(ื˜ื•ื•ื—ืž LAN IPv4 ืชืจื•ืฆืช) Wired LAN IPv4 Configuration
.Enter ืฉืงื”ื• (ื˜ื•ื•ื—ืž LAN IPv4 ืชืจื•ืฆืช) Wired LAN IPv4 Configuration ืจื—ื‘ ,TCP/IP Settings ืชื—ืช
.Wired LAN IPv4 Configuration ืฃื“ืœ ื”ื ืชืฉืž TCP/IP Settings ื˜ื™ืจืคืชื”
Page 18
(DHCP ื‘ืฆืž ) DHCP Mode .1
.Enter ืฉืงื”ื• (DHCP ื‘ืฆืž) DHCP Mode ืจื—ื‘ ,Wired LAN IPv4 Configuration ืชื—ืช
.Wired LAN IPv4 Configuration ืฃื“ืœ ื”ื ืชืฉืž TCP/IP Settings ื˜ื™ืจืคืชื”
ืฉืงื”ื• ENABLED ืจื—ื‘ .ืšืกืžื” ืœืข ื•ื’ืฆื•ื™ ืชื•ืคืกื•ื  ืชื•ื™ื•ืจืฉืคื .DHCP ืชืจืฉ ื™ื“ื™-ืœืข ืขื‘ืงื™ืช TCP/IP ืชื•ืจื“ื’ื” ืชืจื•ืฆืช , ืจืฉืคื•ืืž DHCP ื‘ืฆืž ืื :(ืจืฉืคื•ืืž) ENABLED
.ืื™ืคืกื•ื  ืื™ื‘ืœืฉื‘ ืšืจื•ืฆ ืŸื™ื .Enter
.ืจืฉืคื•ืืž DHCP ื‘ืฆืž
Page 19
.ืชื•ืคืกื•ื  ืชื•ื™ื•ืจืฉืคื ื•ื’ืฆื•ื™ ,DHCP ืชื ืœืจื˜ื ืช ืื .Enter ืฉืงื”ื• ( ืœืจื˜ื•ื ืž) DISABLED ืจื—ื‘
.ืœืจื˜ื•ื ืž DHCP ื‘ืฆืž
(IPv4 ืชื‘ื•ืชื›) IPv4 Address .2
.Enter ืฉืงื”ื• (IPv4 ืชื‘ื•ืชื›) IPv4 Address ืจื—ื‘
.Enter ืฉืงื”ื• ืชื‘ื•ืชื›ื” ืชื“ื•ืžืขื‘ IPv4 -ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
Page 20
(ื”ื ืฉืž ืชืฉืจ ืชื›ื™ืกืž ืชื‘ื•ืชื›) Subnet Mask Address .3
.Enter ืฉืงื”ื• (ื”ื ืฉืž ืชืฉืจ ืชื›ื™ืกืž ืชื‘ื•ืชื›) Subnet Mask Address ืจื—ื‘
.Enter ืฉืงื”ื• ืชื‘ื•ืชื›ื” ืชื“ื•ืžืขื‘ ื”ื ืฉืžื” ืชืฉืจ ืชื›ื™ืกืž ืชื‘ื•ืชื› ืชื ื“ืœืงื”
(ืœื“ื—ืž ืชืจื™ืจื‘ ืจืขืฉ ืชื‘ื•ืชื›) Default Gateway Address .4
Page 21
.Enter ืฉืงื”ื• (ืœื“ื—ืž ืชืจื™ืจื‘ ืจืขืฉ ืชื‘ื•ืชื›) Default Gateway Address ืจื—ื‘
.Enter ืฉืงื”ื• ืชื‘ื•ืชื›ื” ืชื“ื•ืžืขื‘ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืจืขืฉ ืชื‘ื•ืชื› ืชื ื“ืœืงื”
(ืชืคื“ืขื•ืž DNS ืชื‘ื•ืชื›) Preferred DNS Address .5
.Enter ืฉืงื”ื• (ืชืคื“ืขื•ืž SNS ืชื‘ื•ืชื›) Preferred DNS Address ืจื—ื‘
.Enter ืฉืงื”ื• ืชื‘ื•ืชื›ื” ืชื“ื•ืžืขื‘ ืชืคื“ืขื•ืžื” DNS -ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
(ืชื™ืคื•ืœื— DNS ืชื‘ื•ืชื›) Alternate DNS Address .6
Page 22
.Enter ืฉืงื”ื• (ืชื™ืคื•ืœื— SNS ืชื‘ื•ืชื›) Alternate DNS Address ืจื—ื‘
.Enter ืฉืงื”ื• ืชื‘ื•ืชื›ื” ืชื“ื•ืžืขื‘ ืชื™ืคื•ืœื—ื” DNS -ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu .7
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Wired LAN IPv4 Configuration ืชื—ืช
.TCP/IP Settings ื˜ื™ืจืคืชืœ ื”ื ืชืฉืž Wired LAN IPv4 Configuration ื˜ื™ืจืคืชื”
(ื˜ื•ื•ื—ืž LAN IPv6 ืชืจื•ืฆืช) Wired LAN IPv6 Configuration
.Enter ืฉืงื”ื• (ื˜ื•ื•ื—ืž LAN IPv6 ืชืจื•ืฆืช) Wired LAN IPv6 Configuration ืจื—ื‘ ,TCP/IP Settings ืชื—ืช
.Wired LAN IPv6 Configuration ืฃื“ืœ ื”ื ืชืฉืž TCP/IP Settings ื˜ื™ืจืคืชื”
ืœืฉ ื”ืจื•ืฆืช ืขื•ื‘ืงืœ ืฉื™ ,IPv6 ืชื•ื‘ื•ืชื› ืจื•ื‘ืข ื™ืžื ื™ื“ DNS ืœืฉ ืื•ืฉื™ืจ ืจืฉืคืืœ ื™ื“ื› .ื—ืจืืžื” ืœืฉ ื”ืœืขืคื”ื” ืชื›ืจืขืž ืืข ืชื•ืคืชื•ืฉืž ืŸื ื™ืื• ืชื•ื™ื“ื•ืขื™ื™ ืŸื” Intel ME - ื‘ IPv6 -ื” ืชื•ื‘ื•ืชื›
.ื™ื“ื•ืขื™ื™ FQDN
Page 23
:ืชื•ืื‘ื” IPv6 -ื” ืชื•ื‘ื•ืชื› ืืข ืชืฉืจ ืงืฉืžืž ืœื› ืœืฉ ื”ืจื•ืฆืชื” ืชื ืจื™ื“ื’ื”ืœ ืŸืชื™ื  .ืชื™ื‘ ื™ืคื“ ื”ื‘ื•ืจืž IPv6 ืงืฉืžืžื‘ ืชื›ืžื•ืช Intel ME ืœืฉ ืชืฉืจื” ืชื™ื ืกื—ืž :ื”ืจืขื”
ืชื™ื˜ืžื•ื˜ื•ื ืชืจื“ื’ื•ืž ื”ืชืจื•ืฆืชืฉ ืจื•ืฉื™ืงืœ ืชื—ื ืชื™ืžื•ืงืž ืชื‘ื•ืชื›
ืชื™ื˜ืžื•ื˜ื•ื ืชืจื“ื’ื•ืž ืŸืชืจื•ืฆืชืฉ ืชื•ื™ืœื‘ื•ืœื’ ืชื•ื‘ื•ืชื› ืฉื•ืœืฉ
DHCPv6 -ื” ื™ื“ื™-ืœืข ืชืจื“ื’ื•ืž ื”ืชืจื•ืฆืชืฉ ืชื—ื ืชื‘ื•ืชื›
ืชื™ื˜ื˜ืก ื”ืจื•ืฆื‘ ืชืจื“ื’ื•ืž ื”ืชืจื•ืฆืชืฉ ืชื—ื IPv6 ืชื‘ื•ืชื›
(IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘ ) IPv6 feature Selection .1
.Enter ืฉืงื”ื• (IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) IPv6 Feature Selection ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.ืชืœืจื˜ื•ื ืž IPv6 Feature Selection ืชื•ืจืฉืคืื” .Enter ืฉืงื”ื• 'Disabled' ืจื—ื‘ :(ืœืจื˜ื•ื ืž) DISABLED
Page 24
.Enter ืฉืงื”ื• 'Enabled' ืจื—ื‘ :(ืจืฉืคื•ืืž) ENABLED
.(
.ืชืจืชื•ืž ืชืคืกื•ื  ื”ืจื•ืฆืชื• ืชืจืฉืคื•ืืž IPv6 Feature Selection ืชื•ืจืฉืคืื”
(IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type .2
.Enter ืฉืงื”ื• (IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
64) ื™ื ืฉื” ืงืœื—ื” ืื•ื” ืงืฉืžืžื” ื”ื”ื–ืžื• ืŸื•ืฉืืจื” ืงืœื—ื” ืื™ื” IPv6 -ื” ื‘ืชื  ื™ื“ื™-ืœืข ืชืจื“ื’ื•ืžืฉ IPv6 -ื” ืชืžื•ื“ื™ืง , ืื™ืงืœื— ื™ื ืฉืž ืชื‘ื›ืจื•ืž ืชื™ื˜ืžื•ื˜ื•ื ืชืจื“ื’ื•ืž ื”ืชืจื•ืฆืชืฉ IPv6 -ื” ืชื‘ื•ืชื›
Page 25
ื“ื—ื ืœื› ืชื•ื™ื‘ื™ืก
ืชืจื™ืจื‘ ืชืจื“ื’ื” ื™ื”ื•ื– .RFC 3041 -ื‘ ืจืื•ืชืžื› ื™ืืจืงื ืจืคืกืž ืชื•ืขืฆืžืื‘ ืชื™ื˜ืžื•ื˜ื•ื ืงืคื•ืž IPv6 ืงืฉืžืž ื”ื”ื–ืž
.ืœื“ื—ืžื”
ืชื•ืจืฉืคืืจื•ืื™ืช
Random
ื”ื”ื–ืž) ID
(ื™ืืจืงื
Intel ID.MAC -ื” ืชื‘ื•ืชื› ืชื•ืขืฆืžืื‘ ืชื™ื˜ืžื•ื˜ื•ื ืงืคื•ืž IPv6 ืงืฉืžืž ื”ื”ื–ืž
ืšืจืข ืืข ืจื“ื’ื•ื™ ื™ื ื“ื™ื” ืงืฉืžืžื” ื”ื”ื–ืžืฉ ืชื‘ื™ื™ื—ืž ื”ื– ื’ื•ืก ืชืจื™ื—ื‘ .ืชื™ื ื“ื™ ืชืขื‘ืงื  IPv6 ืงืฉืžืž ื”ื”ื–ืž ืœืฉ ื”ืจื•ืฆืชื”
.ืฃืงืช
Manual
ID
(ื™ื ื“ื™ ื”ื”ื–ืž)
(IPv6 ืชื‘ื•ืชื›) IPv6 Address .3
.Enter ืฉืงื”ื• (IPv6 ืชื‘ื•ืชื›) IPv6 Address ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.Enter ืฉืงื”ื• IPv6 -ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
Page 26
(IPv6 ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืชื ) IPv6 Default Router .4
.Enter ืฉืงื”ื• (IPv6 ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืชื ) IPv6 Default Router ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.Enter ืฉืงื”ื• IPv6 ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ื‘ื™ืชื  ืชื ื“ืœืงื”
(ืชืคื“ืขื•ืž DNS IPv6 ืชื‘ื•ืชื› ) Preferred DNS IPv6 Address .5
Page 27
.Enter ืฉืงื”ื• (ืชืคื“ืขื•ืž DNS IPv6 ืชื‘ื•ืชื›) Preferred DNS IPv6 Address ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.Enter ืฉืงื”ื• ืชืคื“ืขื•ืžื” DNS IPv6 -ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
(ืชื™ืคื•ืœื— DNS IPv6 ืชื‘ื•ืชื›) Alternate DNS IPv6 Address .6
.Enter ืฉืงื”ื• (ืชื™ืคื•ืœื— DNS IPv6 ืชื‘ื•ืชื›) Alternate DNS IPv6 Address ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.Enter ืฉืงื”ื• ืชื™ืคื•ืœื—ื” DNS IPv6 - ื” ืชื‘ื•ืชื› ืชื ื“ืœืงื”
Page 28
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu .7
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
.TCP/IP Settings ื˜ื™ืจืคืชืœ ื”ื ืชืฉืž Wired LAN IPv6 Configuration ื˜ื™ืจืคืชื”
(ื™ื˜ื•ื—ืœื LAN IPv6 ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Wireless LAN IPv6 Configuration
.Enter ืฉืงื”ื• (ื™ื˜ื•ื—ืœื LAN IPv6 ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Wireless LAN IPv6 Configuration ืจื—ื‘ ,TCP/IP Settings ืชื—ืช
.Wireless LAN IPv6 Configuration ืฃื“ืœ ื”ื ืชืฉืž TCP/IP Settings ื˜ื™ืจืคืชื”
Page 29
(IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘ ) IPv6 feature Selection .1
.Enter ืฉืงื”ื• (IPv6 ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) IPv6 Feature Selection ืจื—ื‘ ,Wireless LAN IPv6 Configuration ืชื—ืช
(IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type .2
Page 30
.Enter ืฉืงื”ื• (IPv6 ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) IPv6 Interface ID Type ืจื—ื‘ ,Wired LAN IPv6 Configuration ืชื—ืช
64) ื™ื ืฉื” ืงืœื—ื” ืื•ื” ืงืฉืžืžื” ื”ื”ื–ืžื• ืŸื•ืฉืืจื” ืงืœื—ื” ืื™ื” IPv6 -ื” ื‘ืชื  ื™ื“ื™-ืœืข ืชืจื“ื’ื•ืžืฉ IPv6 -ื” ืชืžื•ื“ื™ืง , ืื™ืงืœื— ื™ื ืฉืž ืชื‘ื›ืจื•ืž ืชื™ื˜ืžื•ื˜ื•ื ืชืจื“ื’ื•ืž ื”ืชืจื•ืฆืชืฉ IPv6 -ื” ืชื‘ื•ืชื› .(ื“ื—ื ืœื› ืชื•ื™ื‘ื™ืก
ืชื•ืจืฉืคืืจื•ืื™ืช
ืชืจื™ืจื‘ ืชืจื“ื’ื” ื™ื”ื•ื– .RFC 3041 -ื‘ ืจืื•ืชืžื› ื™ืืจืงื ืจืคืกืž ืชื•ืขืฆืžืื‘ ืชื™ื˜ืžื•ื˜ื•ื ืงืคื•ืž IPv6 ืงืฉืžืž ื”ื”ื–ืž
.ืœื“ื—ืžื”
ืืข ืจื“ื’ื•ื™ ื™ื ื“ื™ื” ืงืฉืžืžื” ื”ื”ื–ืžืฉ ืชื‘ื™ื™ื—ืž ื”ื– ื’ื•ืก ืชืจื™ื—ื‘ .ืชื™ื˜ืžื•ื˜ื•ื ืชืขื‘ืงื  IPv6 ืงืฉืžืž ื”ื”ื–ืž ืœืฉ ื”ืจื•ืฆืชื”
.ืฃืงืช ืšืจืข
Random
ื”ื”ื–ืž) ID
(ื™ืืจืงื
Intel ID.MAC -ื” ืชื‘ื•ืชื› ืชื•ืขืฆืžืื‘ ืชื™ื˜ืžื•ื˜ื•ื ืงืคื•ืž IPv6 ืงืฉืžืž ื”ื”ื–ืž
Manual
ID
(ื™ื ื“ื™ ื”ื”ื–ืž)
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu .3
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Wireless LAN IPv6 Configuration ืชื—ืช
.TCP/IP Settings ื˜ื™ืจืคืชืœ ื”ื ืชืฉืž Wireless LAN IPv6 Configuration ื˜ื™ืจืคืชื”
(ื”ืจื•ืฆืช ืืœืœ ืชืฉืจืœ ื”ืฉื™ื’) Unconfigure Network Access
ืืœืœ ืชืฉืจืœ ื”ืฉื™ื’) Unconfigure Network Access ืจื—ื‘ ,(Intel ME ืชืžืจื•ืคื˜ืœืค ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• ( ื”ืจื•ืฆืช
.ื”ืงืคืกื ื™ื ืคืœ ื‘ืฆืžืœ ืจื•ื‘ืขืœ Intel ME -ืœ ืื•ืจื’ื™ ื”ื– ืจื‘ื“ :ื”ืจืขื”
Page 31
.ื”ืจื•ืฆืช ืœื˜ื‘ืœ ื™ื“ื› (ืŸื›) Y ืจื—ื‘
.Enter ืฉืงื”ื• (ื”ืืœืž ื”ืงืคืกื-ื™ื) Full Unprovisioning ืจื—ื‘
Page 32
.ืขื•ืฆื™ื‘ื‘ ื”ืงืคืกื-ื™ื
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Remote Setup And Configuration
ืฉืงื”ื• (ืงื•ื—ืจืž ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Automated Remote Setup and Configuration ืจื—ื‘ ,Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.Enter
.Automated Remote Setup and Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel ME Platform Configuration ื˜ื™ืจืคืชื”
Page 33
(ื™ื—ื›ื•ื  ื”ืงืคืกื ื‘ืฆืž) Current Provisioning Mode
.Enter ืฉืงื”ื• ( ื™ื—ื›ื•ื  ื”ืงืคืกื ื‘ืฆืž) Current Provisioning Mode ืจื—ื‘ ,(ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Automated Setup and Configuration ืชื—ืช
.PSK ื•ื PKI ,(ืืœืœ) None :ื™ื—ื›ื•ื ื” ื”ืงืคืกืื” TLS ื‘ืฆืž ืชื’ืฆื” โ€“ (ื™ื—ื›ื•ื  ื”ืงืคืกื ื‘ืฆืž ) Current Provisioning Mode
(ื”ืงืคืกื ืชืžื•ืฉืจ) Provisioning Record
Page 34
.Enter ืฉืงื”ื• ( ื”ืงืคืกื ืชืžื•ืฉืจ) Provisioning Record ืจื—ื‘ ,Automated Setup and Configuration ืชื—ืช
Provision Record not" ื”ืขื“ื•ื”ื” ื’ืฆื•ืช Intel MEBx -ื‘ , ื•ื ื–ื•ื” ืืœ ืื™ื ื•ืชื ื” ืื .ืชื›ืจืขืžื” ืœืฉ ื”ืงืคืกืื” PSK/PKI ืชืžื•ืฉืจ ื™ื ื•ืชื  ืชื’ืฆื” โ€“ Provisioning Record
ื™ืจื•ื“ื™ืก ืจืคืกืž
.(ื”ืืฆืžื  ืืœ ื”ืงืคืกื ืชืžื•ืฉืจ) "present
:ืื‘ื” ืŸืคื•ืื‘ ื’ืฆื•ืช ื”ืงืคืกืื” ืชืžื•ืฉืจ ,ื•ื ื–ื•ื” ืื™ื ื•ืชื ื” ืื
.PKI ื•ื PSK ,(ืืœืœ) None :ืชื›ืจืขืžื” ืœืฉ ื™ื—ื›ื•ื ื” ื”ืจื•ืฆืชื” ื‘ืฆืž ืชื’ืฆื”
.ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืชืจืฉ ืœืฉ IP -ื” ืชื‘ื•ืชื›
.MM/DD/YYYY at HH:MM ืชื™ื ื‘ืชื‘ ,ื”ืงืคืกืื” ืœืฉ ื”ืขืฉื”ื• ืšื™ืจืืชื” ืชื’ืฆื”
0 ืšืจืข .ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ื”ืขืฆื‘ืชื”ืฉ ื™ื ืคืœ Intel MEBx -ื‘ ,ืืœ ื•ื ,ื”ืขื‘ืงื  "PKI DNS Suffix" -ื” ืœืฉ ื”ืจื•ืฆืชื” ืื ืŸื•ื™ืฆ
ืจื•ืฉื™ืื‘ FQDN - ืœ ื•ื– ืชืžื•ื™ืก ื”ื•ื•ืฉืชื• DHCP option 15 ืœืข ืงืจ ืšืžืชืกืช ื”ื—ืฉื•ืงื”ื• ื”ืขื‘ืงื  ืืœ DNS - ื” ืชืžื•ื™ืก ืชืจื•ืฆืชืฉ ืŸื™ื™ืฆืž
ืจื•ืฉื™ืื‘ DNS -ื” ืชืžื•ื™ืกืœ ื”ืชื•ื ืื™ืืชืช ื”ื—ืฉื•ืงื”ืฉื• ื”ืขื‘ืงื  DNS -ื” ืชืžื•ื™ืก ืชืจื•ืฆืชืฉ ืŸื™ื™ืฆืž 1 ืšืจืข .ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชืจืฉ ืœืฉ ื—ื•ืงืœื”
.ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชืจืฉ ืœืฉ ื—ื•ืงืœื”
ืŸื™ื™ืฆืž (ืืœ) "No" :ื—ืจืืžื” ื™ื“ื™-ืœืข ืœืขืคื•ื” ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืšื™ืœื”ืช ืื ืŸื•ื™ืฆ โ€“ ( ื—ืจืืž ื™ื“ื™-ืœืข ืœืขืคื•ืž) Host Initiated
ื™ื“ื™-ืœืข ืœืขืคื•ื” ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืšื™ืœื”ืชืฉ ืŸื™ื™ืฆืž (ืŸื›) "Yes" .ื—ืจืืžื” ื™ื“ื™-ืœืข ืœืขืคื•ื” ืืœ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืšื™ืœื”ืชืฉ
.(ื“ื‘ืœื‘ PKI) ื—ืจืืžื”
.(ื“ื‘ืœื‘ PKI) ืื™ื•ื•ืชื” 40 ืŸื‘ ืจื•ืฉื™ืื” ืœืฉ Hash -ื” ื™ื ื•ืชื  ืชื’ืฆื”
.(ื“ื‘ืœื‘ SHA1 (PKI -ื‘ ืงืจ ื”ื›ื™ืžืช ืฉื™ ,ืขื’ืจื› .Hash -ื” ื’ื•ืก ืจื•ืื™ืช
ืชื•ืจืฉืคืืจื•ืื™ืช
TLS
provisioning
mode
(TLS ืœืฉ ื”ืงืคืกื ื‘ืฆืž)
Provisioning IP
ืœืฉ IP ืชื‘ื•ืชื›)
(ื”ืงืคืกืื”
Date of
Provision
(ื”ืงืคืกื ืšื™ืจืืช)
DNS
Hash Data
(Hash ื™ื ื•ืชื )
Hash Algorithm
(Hash ืืชื™ืจื•ื’ืœื)
Hash -ื” ืืชื™ืจื•ื’ืœื ืื (ืืœ) "No" ืชื’ืฆื” .ืจื—ื‘ื ืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืืชื™ืจื•ื’ืœื ืื•ื” Hash -ื” ืืชื™ืจื•ื’ืœื ืื (ืŸื›) "Yes" ืชื’ืฆื”
.(ื“ื‘ืœื‘ PKI)
.(ืื™ืจื•ืฉื™ืื” ืชื•ืฉืจ) Certificate Authority -ื” ืœืฉ ืื™ื™ืจื•ื“ื™ืกื” ืื™ืจืคืกืžื” ืชื ืชื ื™ื™ืฆืžื” ืื™ื•ื•ืชื” 32 ืชื‘ ืชื–ื•ืจื—ืžื”
ืฉื•ืžื™ืฉื‘ืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืืชื™ืจื•ื’ืœื ื•ื ื™ื
IsDefault
FQDN.(ื“ื‘ืœื‘ PKI) ืจื•ืฉื™ืื‘ ืจื›ื–ื•ืžืฉ ื”ืงืคืกืื” ืชืจืฉ ืœืฉ FQDN - ื”
Serial Number
(
)
Page 35
Time Validity
.ืŸืžื–ื” ืชื•ื™ืงื•ื— ืชืงื™ื“ื‘ ืชื ืจื‘ืข ืจื•ืฉื™ืื” ืื ืŸื•ื™ืฆ
(ืŸืžื– ืชื•ื™ืงื•ื— ืจื‘ืข)
Pass
RCFG
.Enter ืฉืงื”ื• RCFG ืจื—ื‘ ,(Intel ืœืฉ ืงื•ื—ืจืž ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Intel Automated Remote Setup and Configuration ื˜ื™ืจืคืชื‘
.(Intel ืœืฉ ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel Remote Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel Automated Remote Setup and Configuration ื˜ื™ืจืคืชื”
(ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชืœื—ืชื”) Start Configuration
.Enter ืฉืงื”ื• ( ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชืœื—ืชื”) Start Configuration ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
.ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืขืฆื‘ืœ ืŸืชื™ื  ืืœ ,ืชืœืขืคื•ืž ื”ื ื™ื ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืื
.(ืŸื›) Y ืจื—ื‘ ,ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง (ืจืฉืคืืœ) ืœื™ืขืคื”ืœ ื™ื“ื›
Page 36
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
.Intel Automated Remote Setup and Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel Remote Configuration ื˜ื™ืจืคืชื”
(IPv4/IPv6 ื”ืงืคืกื ืชืจืฉ) Provisioning Server IPv4/IPv6
.Enter ืฉืงื”ื• (IPv4/IPv6 ื”ืงืคืกื ืชืจืฉ) Provisioning Server IPv4/IPv6 ืจื—ื‘ ,Intel Automated Setup and Configuration ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• ื”ืงืคืกืื” ืชืจืฉ ืชื‘ื•ืชื› ืชื ื“ืœืงื”
Page 37
.Enter ืฉืงื”ื• ื”ืงืคืกืื” ืชืจืฉ ืœืฉ ื”ืื™ืฆื™ื” ืจืคืกืž ืชื ื“ืœืงื”
.9971 ืื•ื” ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืื™ืฆื™ ืจืคืกืž .Intel AMT ืœืฉ ื”ืงืคืกืื” ืชืจืฉ ืœืฉ (65535 โ€“ 0) ื”ืื™ืฆื™ื” ืจืคืกืž
(FQDN ื”ืงืคืกื ืชืจืฉ) Provisioning Server FQDN
.Enter ืฉืงื”ื• (FQDN ื”ืงืคืกื ืชืจืฉ) Provisioning Server FQDN ืจื—ื‘ ,Intel Automated Remote Setup and Configuration ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• ื”ืงืคืกืื” ืชืจืฉ ืœืฉ PQDN -ื” ืชื ื“ืœืงื”
Page 38
.ื“ื—ื™ ืื’ PKI -ื• PSK ืจื•ื‘ืข ,ืชื•ื ืž ื—ืœื•ืฉ AMT ื•ื™ืœืืฉ ืชืจืฉื” ืœืฉ FQDN -ื” ืื’ ื•ื”ื– .(ื“ื‘ืœื‘ PKI) ืจื•ืฉื™ืื‘ ืจื›ื–ื•ืžืฉ ื”ืงืคืกืื” ืชืจืฉ ืœืฉ FQDN -ื”
TLS PSK
.Enter ืฉืงื”ื• TLS PSK ืจื—ื‘ ,(Intel ืœืฉ ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Intel Automated Setup and Configuration ื˜ื™ืจืคืชื‘
.(Intel ืœืฉ TLS PSK ืชืจื•ืฆืช ืชืขื™ื‘ืง) Intel TLS PSK Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel Automated Setup and Configuration ื˜ื™ืจืคืชื”
TLS PSK ืœืฉ ื”ืจื•ืฆืชื” ืชื•ืจื“ื’ื” ืชื ืœืœื•ื› ื”ื– ื”ื ืฉืž ื˜ื™ืจืคืช
Page 39
(PPS -ื• PID ืชืจื“ื’ื”) Set PID and PPS
.Enter ืฉืงื”ื• (PSS -ื• PID ืชืจื“ื’ื”) Set PID and PPS ืจื—ื‘ ,Intel TLS PSK Configuration ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• PID ื“ืœืงื”
.Enter ืฉืงื”ื• PPS ื“ืœืงื”
PID: 1234-ABCD ื”ืžื’ื•ื“) .ืฃืงืž ืชื™ื ื‘ืชื‘ PPS -ื”ื• PID -ื” ืชื ืŸื™ื–ื”ืœ ืฉื™ ."ืขื•ืฆื™ื‘ื‘" ืื™ืืฆืžื  ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืื ,ืชื™ืงืœื— ื”ืงืคืกื-ื™ืืœ ืื•ืจื’ืช PID/PPS - ื” ืชืจื“ื’ื”
.(; PPS: 1234-ABCD-1234-ABCD-1234-ABCD-1234-ABCD
ื‘ืฆืž , ื”ื– ืšืจืขื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื  ืื .ื”ืจื“ื’ื”ื” ืœืฉ ื”ืจื•ืฆืชื” ื‘ืฆืž ืชื ื”ื ืฉื™ ืืœ "0000-0000-0000-0000-0000-0000-0000-0000" ืœืฉ PPS ืšืจืข :ื”ืจืขื”
.(ืœื™ื—ืชื” ืืœ) 'Not-started' -ื› ืจืชื•ื  ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื”
(PPS -ื• PID ืชืงื™ื—ืž) Deleting PID and PPS
.Enter ืฉืงื”ื• (PSS -ื• PID ืชืงื™ื—ืž) Delete PID and PPS ืจื—ื‘ ,Intel TLS PSK Configuration ื˜ื™ืจืคืชื‘
.Intel MEBx -ืž ื”ืื™ื’ืฉ ืชืขื“ื•ื” ืจื–ื—ื•ืช , ืŸื›ืœ ืื“ื•ืง ื•ื ื–ื•ื” ืืœ PPS -ื”ื• PID -ื” ืื .Intel ME -ื‘ ืื™ื ืกื—ื•ืืžืฉ ืื™ื™ื—ื›ื•ื ื” PPS -ื”ื• PID -ื” ืชื ืชืงื—ื•ืž ื•ื– ืชื•ืจืฉืคื
.(ืืœ) N ืจื—ื‘ ,ืงื•ื—ืžืœ ื”ืฆืจืช ืืœ ืื .(ืŸื›) Y ืจื—ื‘ ,PPS -ื”ื• PID -ื” ื™ื›ืจืข ืชื ืงื•ื—ืžืœ ื™ื“ื›
Page 40
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel TLS PSK Configuration ื˜ื™ืจืคืชื‘
.Intel Automated Remote Setup and Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel TLS PSK Configuration ื˜ื™ืจืคืชื”
TLS PKI
.Enter ืฉืงื”ื• TLS PKI ืจื—ื‘ ,Intel Automated Setup and Configuration ื˜ื™ืจืคืชื‘
.(Intel ืœืฉ ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel Remote Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel Automated Remote Setup and Configuration ื˜ื™ืจืคืชื”
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Remote Configuration
.Enter ืฉืงื”ื• ( ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Remote Configuration ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
.(ืขื•ืฆื™ื‘ื‘) "In-process" ื‘ืฆืžื‘ ืืฆืžื  ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืชืจืฉ ืื ,ืชื™ืงืœื— ื”ืงืคืกื-ื™ืืœ ืื™ืžืจื•ื’ ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืœืฉ ืœื•ืจื˜ื /ืจื•ืฉืคื
ืชื•ืจืฉืคืืจื•ืื™ืช
ืŸื›ื• (ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) 'Remote Configuration' ืื™ื˜ื™ืจืคื” ืงืจ .ืชืœืจื˜ื•ื ืž ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง
.ืื™ื™ื•ืœื’ (ืื“ื•ืง ื˜ื™ืจืคืช) 'Previous Menu'
.ืื™ื’ืฆื•ืž ืื™ืคืกื•ื  ืชื•ื“ืฉื• ,ืชืจืฉืคื•ืืž ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง
.Enter ืฉืงื”ื• ( ืœืจื˜ื•ื ืž) Disabled ืจื—ื‘ :Disabled ืจื•ื‘ืข
.Enter ืฉืงื”ื• ( ืจืฉืคื•ืืž) Enabled ืจื—ื‘ :Enabled ืจื•ื‘ืข
Disabled
(ืœืจื˜ื•ื ืž)
Enabled
(ืจืฉืคื•ืืž)
Page 41
PKI DNS Suffix
.Enter ืฉืงื”ื• (PKI DNS ืชืžื•ื™ืก) PKI DNS Suffix ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• PKI DNS -ื” ืชืžื•ื™ืก ืชื ื“ืœืงื”
(Hash ื™ื’ื•ืก ืœื•ื”ื™ื ) Manage Hashes
Page 42
.Enter ืฉืงื”ื• (Hash ื™ื’ื•ืก ืœื•ื”ื™ื ) Manage Hashes ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
ืื‘ื” ืšืกืžื” , ืŸื™ื™ื“ืข Hash ื”ืœื™ื›ืž ื”ื ื™ื ืชื›ืจืขืžื” ืื .ืœื“ื—ืžื” ืชืจื™ืจื‘ ื‘ืฆืžื• ืœื™ืขืคื” ื‘ืฆืžื” ืชืื• Hash Name - ื” ืชื ื’ื™ืฆืชื• ืชื›ืจืขืžื‘ Hash -ื” ื™ื’ื•ืก ืชื ืจื•ืคืกืช ื•ื– ืชื•ืจืฉืคืื‘ ื”ืจื™ื—ื‘
.Intel MEBx -ื‘ ื’ืฆื•ื™
.ืŸืœื”ืœ ืื‘ื” ืฃื™ืขืกื‘ ืŸื™ื™ืข . ืœื—ื™ ืชื™ืฉื™ื ืืืชื•ืž Hash ืชืคืกื•ื” ืšื™ืœื”ืช ,(ืŸื›) "Yes" ื”ื ืขืช ืื
Manage ื˜ื™ืจืคืชื‘ ืื™ื ื™ืžื– ืื™ืื‘ื” ืื™ืฉืงืžื” .ืชื›ืจืขืžื‘ Hash -ื” ื™ื’ื•ืก ืœื•ื”ื™ื ืœ ืชื“ืœืงืž ืชื•ืจืงื‘ ืงืคืกืž (ืจื•ืฉื™ื ืœื•ื”ื™ื  ืœืฉ Manage Certificate Hash (Hash ืšืกืžื”
.Certificate Hash
ืฉืงืžืจื•ืื™ืช
Escape.ื˜ื™ืจืคืชื”ืž ื”ืืฆื™
Insert.ืชื›ืจืขืžืœ ืชื™ืฉื™ื ืืืชื•ืž ืจื•ืฉื™ื Hash ืชืคืกื•ื”
Delete.ืชื›ืจืขืžื”ืž ื•ืจื—ื‘ื ืฉ ืื™ืจื•ืฉื™ืื” Hash ืชืงื™ื—ืž
+.ืจื—ื‘ื ืฉ ืจื•ืฉื™ืื” Hash ืœืฉ ืœื™ืขืคื” ื‘ืฆืžื” ื™ื•ื ื™ืฉ
Enter.ืจื—ื‘ื ืฉ ืจื•ืฉื™ืื” Hash ืœืฉ ืื™ื˜ืจืคื” ืชื’ืฆื”
Page 43
(ืชื™ืฉื™ื ืืืชื•ืž Hash ืชืคืกื•ื”) Adding Customized Hash
:ืื‘ื” ืšืกืžื” ืชื’ืฆื”ืœ ืชืžืจื•ื’ ,Manage Certificate Hash ืšืกืžื‘ Insert ืฉืงืžื” ืœืข ื”ืฆื™ื—ืœ
.ืจื•ืฉื™ืื” Hash ืšืจืข ืชื ืŸื™ื–ื”ืœ ืฉืงื‘ืชืช ,Enter ืœืข ื”ืฉืงื”ื‘ .(ืื™ื•ื•ืช 32 ื“ืข) Hash -ื” ืืฉ ืชื ืŸื–ื” :ืชื™ืฉื™ื ืืืชื•ืž ืจื•ืฉื™ื Hash ืฃื™ืกื•ื”ืœ ื™ื“ื›
Invalid Hash" ื”ืขื“ื•ื”ื” ื’ืฆื•ืช ,ื”ืžื™ืืชืžื” ืชื™ื ื‘ืชื‘ ืŸื–ื•ืž ื•ื ื™ื ืšืจืขื” ืื .(ืื™ืชื‘ 32 ื”ื– SHA-2 ืจื•ื‘ืข ืื™ืชื‘ 20 ื”ื– SHA-1 ืจื•ื‘ืข) ื™ืœืžื™ืฆื“ืกืงื” ืจืคืกืž ืื•ื” ืจื•ืฉื™ืื” Hash ืšืจืข
.Hash -ื” ืœืฉ ืœื™ืขืคื” ื‘ืฆืžื” ืชื ืจื™ื“ื’ื”ืœ ืฉืงื‘ืชืช ,"Enter" ืœืข ื”ืฉืงื”ื‘ .(ื‘ื•ืฉ ื”ืกื  - ื™ืงื•ื— ืืœ Hash ืจื•ืฉื™ื ืŸื–ื•ื”) "Certificate Entered - Try Again
Page 44
:ืื‘ื” ืŸืคื•ืื‘ , ืชื™ืฉื™ื ืืืชื•ืžื” Hash -ื” ืœืฉ ืœื™ืขืคื” ื‘ืฆืžื” ืชื ื”ืจื™ื“ื’ืž ืšืชื‘ื•ืฉืช
.ืœื™ืขืคื› ืŸืžื•ืกืž ืชื™ืฉื™ื ืืืชื•ืžื” Hash -ื” ( ืŸื›) Yes
.ืœื™ืขืค ื”ื™ื”ื™ ืืœ ืšื ,EPS -ืœ ืฃืกื•ื•ืชื™ ืชื™ืฉื™ื ืืืชื•ืžื” Hash - ื” ( ืืœ) (ืœื“ื—ืž ืชืจื™ืจื‘) No
(Hash ืชืงื™ื—ืž) Deleting a Hash
:ืื‘ื” ืšืกืžื” ืชื’ืฆื”ืœ ืชืžืจื•ื’ ,Manage Certificate Hash ืšืกืžื‘ Delete ืฉืงืžื” ืœืข ื”ืฆื™ื—ืœ
.ืœื“ื—ืžื” ืชืจื™ืจื‘ ืšืจืขื› ืจื“ื’ื•ืžืฉ ืจื•ืฉื™ื ืœืฉ Hash ืงื•ื—ืžืœ ืŸืชื™ื  ืืœ :ื”ืจืขื”
Page 45
.ืจื—ื‘ื ืฉ ืจื•ืฉื™ืื” Hash ืชื ืงื•ื—ืžืœ ืชืจืฉืคืืž ื•ื– ืชื•ืจืฉืคื
.ื”ื—ืฉื•ืงืœ Intel MEBx ื™ื“ื™ ืœืข ืชื—ืœืฉื  ืจื—ื‘ื ืฉ Hash - ื” ืชืงื™ื—ืžืœ ื”ืขื“ื•ื” (ืŸื›) Yes
.ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืจื“ื’ื”ืœ ืชืจื–ื•ื— ืชื›ืจืขืžื”ื• Intel MEBx ื™ื“ื™-ืœืข ืงื—ืžื  ื•ื ื™ื ืจื—ื‘ื ืฉ Hash -ื” (ืืœ) No
(ืœื™ืขืคื” ื‘ืฆืžื” ื™ื•ื ื™ืฉ) Changing the Active State
:ืื‘ื” ืšืกืžื” ืชื’ืฆื”ืœ ืชืžืจื•ื’ ,Manage Certificate Hashes ืšืกืžื‘ '+' ืฉืงืžื” ืœืข ื”ืฆื™ื—ืœ
.PSK ืชืงืคืกื ืšืœื”ืžื‘ ืฉื•ืžื™ืฉืœ ืŸื™ืžื– Hash -ื”ืฉ ืชื ื™ื™ืฆืž ืœื™ืขืคื› Hash ืชืจื“ื’ื” .ืจื—ื‘ื ืฉ ืจื•ืฉื™ืื” Hash ืœืฉ ืœื™ืขืคื” ื‘ืฆืžื” ื™ื•ื ื™ืฉืœ ืชืžืจื•ื’ (ืŸื›) Y ืœืฉ ื”ื‘ื•ืฉืช
(ืจื•ืฉื™ื Hash ืชื’ืฆื”) Viewing a Certificate Hash
:ืื‘ื” ืšืกืžื” ืชื’ืฆื”ืœ ืชืžืจื•ื’ ,Manage Certificate Hash ืšืกืžื‘ Enter ืฉืงืžื” ืœืข ื”ืฆื™ื—ืœ
Page 46
:ืื™ืื‘ื” ืื™ื˜ืจืคื” ืชื ืื™ืœืœื•ื›ื• ืฉืžืชืฉืžื” ื™ื ืคื‘ ืื™ื’ืฆื•ืž ืจื—ื‘ื ืฉ ืจื•ืฉื™ืื” Hash ืœืฉ ืื™ื˜ืจืคื”
Hash ืืฉ
ืจื•ืฉื™ื Hash ื™ื ื•ืชื 
ืœื“ื—ืž ืชืจื™ืจื‘ื• ืœื™ืขืค ื‘ืฆืž
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel Remote Configuration ื˜ื™ืจืคืชื‘
.Intel Automated Remote Setup and Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel Remote Configuration ื˜ื™ืจืคืชื”
(ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข ืชื•ืจื“ื’ื”) FW Update Settings
.Enter ืฉืงื”ื• (ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข ืชื•ืจื“ื’ื”) FW Update Settings ืจื—ื‘ ,(Intel ME ืชืžืจื•ืคื˜ืœืค ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.FW Update Settings ืฃื“ืœ ื”ื ืชืฉืž Intel FW Platform Configuration ื˜ื™ืจืคืชื”
Page 47
(ื™ืžื•ืงืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Local FW Update
.Enter ืฉืงื”ื• (ื™ืžื•ืงืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Local FW Update ืจื—ื‘ ,FW Update Settings ื˜ื™ืจืคืชื‘
ืœื’ื•ืกืž IT -ื” ืœื”ื ืž ,(ืจืฉืคื•ืืž) "Enabled" ืชื•ืจืฉืคืื” ืชืจื—ื‘ื  ืจืฉืื› .ื”ื“ืฉื‘ ื”ื—ืฉื•ืงื” ืœืฉ ื™ืžื•ืงืž ืŸื•ื›ื“ืข ืขื•ื ืžืœ ื•ื ืจืฉืคืืœ ืชืœื•ื›ื™ื” ืชื ืงืคืกืž Intel ME ืชื—ืฉื•ืง ืœืฉ ื™ืžื•ืงืžื” ืŸื•ื›ื“ืขื”
.ื™ืžื•ืงืžื” ื—ื˜ื‘ื•ืืžื” ืงืฉืžืžื” ืšืจื“ ื•ื Intel Management Engine ืงืฉืžืž ืšืจื“ ืชื™ืžื•ืงืž ื”ืจื•ืฆื‘ Intel ME ืชื—ืฉื•ืง ืชื ืŸื›ื“ืขืœ
(ืœืจื˜ื•ื ืž) "Disabled" -ื› ืชื™ื˜ืžื•ื˜ื•ื ืชืจื“ื’ื•ืž ื•ื– ื”ืจื“ื’ื” ,ื™ืžื•ืงืžื” ืŸื•ื›ื“ืขื” ืชืžืœืฉื” ืจื—ืืœ ,ืŸื›ืœ .ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉื‘ ืฉืžืชืฉื”ืœ ืชื›ืจืขืžื” ืœื”ื ืž ืชื ื‘ื™ื™ื—ืž ื•ื ื™ื ื”ื– ื™ืžื•ืงืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข
.(ืจืฉืคื•ืืž ) "Enabled" -ื› ื•ื– ืชื•ืจืฉืคื ืจื™ื“ื’ื”ืœ ืฉื™ ,ื™ืžื•ืงืž ืŸื•ื›ื“ืข ืฉื•ืจื“ ืจืฉืื› .Intel ME ืชื—ืฉื•ืง ื™ื“ื™-ืœืข
Page 48
(ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Secure FW Update
.Enter ืฉืงื”ื• (ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข) Secure FW Update ืจื—ื‘ ,FW Update Settings ื˜ื™ืจืคืชื‘
ืืœ ืื .ืชื›ืจืขืž ืœื”ื ืž ืœืฉ ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ ืชื‘ื™ื™ื—ืž Secure Firmware Update ื”ื™ืฆืงื ื•ืคื” . ืื™ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ื™ื ื•ื›ื“ืข ืœืจื˜ื ืœ ื•ื ืจืฉืคืืœ ืฉืžืชืฉืžืœ ืชืจืฉืคืืž ื•ื– ืชื•ืจืฉืคื
.ื”ื—ืฉื•ืงื” ืชื ืŸื›ื“ืขืœ ืŸืชื™ื  ืืœ , ืชื›ืจืขืž ืœื”ื ืž ืœืฉ ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ ืื™ืงืคื•ืกืž
ืœื”ื ืž ืšืจื“ ืื™ืขืฆื•ื‘ืž ืื™ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ื™ื ื•ื›ื“ืข .ืชื—ื˜ื‘ื•ืืžื” ื”ื˜ื™ืฉื” ืชื•ืขืฆืžืื‘ ื”ื—ืฉื•ืงื” ืชื ืŸื›ื“ืขืœ ืœื•ื›ื™ IT - ื” ืœื”ื ืž ,ืชืจืฉืคื•ืืž Secure Firmware Update ื”ื ื•ื›ืชื” ืจืฉืื›
.LMS ืŸืงืชื”ื”
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,FW Update Settings ื˜ื™ืจืคืชื‘
.Intel ME Platform Configuration ืฃื“ืœ ื”ื ืชืฉืž FW Update Settings ื˜ื™ืจืคืชื”
(PRTC ืชืจื“ื’ื”) Set PRTC
.Enter ืฉืงื”ื• (PRC ืชืจื“ื’ื”) Set PRC ืจื—ื‘ ,Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
Page 49
.(G3) ื™ื•ื‘ื™ื› ื‘ืฆืž ืšืœื”ืžื‘ PRTC ืœืฉ ืชื™ืœืื•ื˜ืจื™ื• ื”ืงื•ื–ื—ืชืœ ืชืฉืžืฉืž PRTC -ื” ืšืจืข ืชืจื“ื’ื” .01/04/2021 - 01/01/2004 :ื™ืงื•ื— ืื™ื›ื™ืจืืช ื—ื•ื•ื˜
.Enter ืฉืงื”ื• (GMT (UTC) (YYYY:MM:DD:HH:MM:SS ืชื™ื ื‘ืชื‘ PRTC ื“ืœืงื”
(ืœืžืฉื— ืชื›ื™ืจืฆ ืชืจืงื‘) Power Control
.Enter ืฉืงื”ื• ( ืœืžืฉื— ืชื›ื™ืจืฆ ืชืจืงื‘) Power Control ืจื—ื‘ ,Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.Intel Power Control ืฃื“ืœ ื”ื ืชืฉืž Intel ME Platform Configuration ื˜ื™ืจืคืชื”
Page 50
ืœืฉ ืœืžืฉื— ืชื›ื™ืจืฆ ืชืจืงื‘) Intel ME Power Control ื˜ื™ืจืคืชื” .ื”ื ื™ืฉ ื™ื‘ืฆืž ืจืคืกืžื‘ Intel ME ืชื ืชื•ื‘ื›ืœ ืŸืชื™ื  ,EUP LOT6 -ื• *ENERGY STAR ืชื•ืฉื™ืจื“ื‘ ื“ื•ืžืขืœ ื™ื“ื›
.Intel ME ืชืžืจื•ืคื˜ืœืค ืœืฉ ืœืžืฉื—ื” ืชื›ื™ืจืฆืœ ื”ืจื•ืฉืงื” ืชื•ื™ื ื™ื“ืž ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื‘ื•ืง (Intel ME
Intel ME ON in Host Sleep States
.Enter ืฉืงื”ื• Intel ME ON in Host Sleep States ืจื—ื‘ ,Intel ME Power Control ื˜ื™ืจืคืชื‘
.FPT ื•ื FITC ืชื•ืขืฆืžืื‘ ืœืžืฉื— ืชื›ื™ืจืฆ ืœื•ื”ื™ื ืœ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืœื™ื‘ื— ืชื ืชื•ื ืฉืœ ืŸืชื™ื  . ืœืขืคื•ื™ Intel ME - ื” ื™ืชืž ืชืขื‘ื•ืง ื”ืจื—ื‘ื ืฉ ืœืžืฉื—ื” ืชื›ื™ืจืฆ ืชืœื™ื‘ื—
.ืชื›ืจืขืžื‘ ืฉื•ืžื™ืฉืœ ืืืชื”ื‘ ,ืฉื•ืžื™ืฉ ื”ืฉืขื™ื™ ื”ื‘ืฉ ืœืžืฉื—ื” ืชื›ื™ืจืฆ ืชืœื™ื‘ื— ืชื ืจื•ื—ื‘ืœ ืœื•ื›ื™ ื”ืฆืงื” ืฉืžืชืฉืž ืœื”ื ืž
.ืœืžืฉื—ื” ืชื›ื™ืจืฆ ืชื•ืœื™ื‘ื— ืœืฉ ืื™ื˜ืจืคื” ืชื ื”ืฉื™ื—ืžืž ื”ืื‘ื” ื”ืœื‘ื˜ื”
M3 ื•ื M0 ื‘ืฆืžืœ ืจื•ื‘ืขื™ Intel ME ,ื•ื– ื”ื“ื•ืงืค ืชื—ื™ืœืฉ ืจื—ืืœ .ME -ื” ืœื ื”ื“ื•ืงืค ืชื—ื™ืœืฉืœ ื“ืข M-off ื‘ืฆืžื‘ ืจืืฉื  Intel ME , ืŸืžื–ื” ืงืกืค ืชืขื™ืงืค ืจื—ืืœ ,Intel ME WoL ืืข
.M3 ื•ื M0 ื‘ืฆืžืœ ืจื•ื‘ืขืœ Intel ME - ืœ ืื•ืจื’ื™ ืื’ Intel ME -ืœ ืชื•ืชื™ื .ืชื—ืœืฉื ืฉ ื”ืื‘ื” ื”ื“ื•ืงืคืœ ื‘ื™ื’ื™ื•
M0 ื‘ืฆืžืœ ืขื™ื’ื™ Intel ME -ืฉ ืจื—ืืœ .ืŸื”ืฉืœื› Intel ME ืชื•ื“ื•ืงืคืœ ื‘ื™ื’ื™ ืืœ Intel AMT ,ื”ื– ืŸืžื– ืšืœื”ืžื‘ .M3 ื•ื M0 ื‘ืฆืžืœ M-off ื‘ืฆืžืž ืจื•ื‘ืขืœ ืจืฆืง ืŸืžื– ื—ืงื•ืœ Intel ME -ืœ
.Intel ME ืชื•ื“ื•ืงืคืœ ื‘ื™ื’ืช ืชื›ืจืขืžื” ,M3 ื•ื
ืœืžืฉื— ืชื›ื™ืจืฆ ืชืœื™ื‘ื—12
S0ONON S3OFFON/ ME WoL
S4/S5OFFON/ ME WoL
.Enter ืฉืงื”ื• ,ื”ื™ื•ืฆืจื” ืœืžืฉื—ื” ืชื›ื™ืจืฆ ืชื•ื™ื ื™ื“ืž ืชื ืจื—ื‘
.MEBx ื•ื ืœื•ื”ื™ื ื” ืฃื•ืกืž ,WebUI ืšืจื“ ืจืชื•ื™ ืจื—ื•ืืž ื“ืขื•ืžื‘ ืชืื– ืชื•ื ืฉืœ ืŸืชื™ื  .2 ืœืžืฉื— ืชื›ื™ืจืฆ ืชืœื™ื‘ื—ืœ ืจื‘ืขืžืœ ืชื™ื˜ืžื•ื˜ื•ื ืื•ืจื’ืช ื”ืงืคืกื ื‘ืฆืžืœ ืชื›ืจืขืž ืชืจื‘ืขื” :ื”ืจืขื”
(ืงืจืก ื‘ืฆืžื‘ ืŸืžื– ืงืกืค) Idle Time Out
.Enter ืฉืงื”ื• (ืงืจืก ื‘ืฆืžื‘ ืŸืžื– ืงืกืค) Idle Time Out ืจื—ื‘ ,Intel ME Power Control ื˜ื™ืจืคืชื‘
Page 51
ืšืฉืž ืชื ืŸื™ื™ืฆืž ืšืจืขื” .ืชื•ืงื“ื‘ ืšืจืขื” ืชื ืŸื™ื–ื”ืœ ืฉื™ .M3 ื‘ืฆืžื‘ Intel ME -ื” ืœืฉ ืชื•ืœื™ืขืค ืจืกื•ื— ืœืฉ ืŸืžื– ืงืกืค ืชืจื“ื’ื”ืœื• Intel ME Wake on ื”ื ื•ื›ืชื” ืจื•ืฉืคืืœ ืชืฉืžืฉืž ื•ื– ื”ืจื“ื’ื”
.(ื™ื•ื‘ื›) M-off ื‘ืฆืžืœ ืจื•ื‘ืขื™ืฉ ื™ื ืคืœ M3 ื‘ืฆืžื‘ ืชื•ืœื™ืขืค ืืœืœ ืจืืฉื™ื”ืœ ืœื•ื›ื™ Intel ME -ืฉ ืŸืžื–ื”
.M-off - ืœ ืจื•ื‘ืขื™ ืืœ ืื•ื” ,M0 -ื‘ ืืฆืžื  Intel ME -ื” ืื :ื”ืจืขื”
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel ME Platform Configuration ื˜ื™ืจืคืชื‘
.Intel ME Platform Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel ME Power Control ื˜ื™ืจืคืชื”
.Intel ื™ื“ื™-ืœืข ืŸืชื™ื  ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
*
Page 52
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง
.ื™ืงื  ืชื›ืจืขืž ืœื•ื—ืชื ืชืœื‘ืง ืืฉืœ ,Intel AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ื™ื ืคืœ ืฉื“ื—ืž ืœื—ืชืืœ ืšื™ืœืข ,(Intelยฎ Management Engine (ME ื”ื ื•ื›ืชื” ืœืฉ ื”ืืœืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืจื—ืืœ
ื‘ืฉื—ืž ืจื™ื“ื’ื”ืœ ืชืจืฉืคืืž ื•ื– ื”ื ื•ื›ืช .(Management Engine BIOS Extension (MEBx ืœืฉ ื™ืฉืืจื” ื˜ื™ืจืคืชื”ืž Intel AMT configuration ืชื•ืจืฉืคืื‘ ืจื—ื‘
.Intel AMT ืœืฉ ืœื•ื”ื™ื ื” ืชื•ื ื•ื›ืชื‘ ื”ื›ื™ืžืชืœ Intel AMT ืชืœื•ื›ื™ ืืข
ืœื“ื—ืž ืชืจื™ืจื‘ ืจืขืฉ ,ื”ื ืฉืž ืชืฉืจ ืชื›ื™ืกืž ,TCP/IP, DHCP, VLAN, IDE, DNS ืŸื•ื’ื› ,ืื™ื‘ืฉื—ืž ืชื™ื™ื’ื•ืœื•ื ื›ื˜ ืœืฉ ืื™ื—ื ื•ืžื• ืชืฉืจื‘ ื”ื“ื•ื‘ืข ืœืฉ ืชื™ืกื™ืกื‘ ื”ื ื‘ื”ืœ ืงืงื“ื–ืช :ื”ืจืขื”
.ื”ื– ืšืžืกืž ืฃืงื™ื”ืž ืชื’ืจื•ื— ื”ืœื ืื™ื—ื ื•ืž ืชืจื‘ืกื” .ืื•ื—ืช ืืฉื•
.ืื™ื ื•ืฉื” ืื™ืคื™ืขืกืœ ืื™ืจื™ื”ืž ืื™ืจื•ืฉื™ืง ืŸืœื”ืœ .Intel AMT Configuration ืฃื“ื” ืขื™ืคื•ืž
(ืœื•ื”ื™ื  ืชืœื•ื›ื™ ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) Manageability Feature Selection
SOL/IDER
(ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ) Username and Password
SOL
(ืฉื“ื—ืž ื‘ื•ืชื™ื  ื‘ืฆืž) Redirection Mode
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(KVM ืชืจื•ืฆืช) KVM Configuration
(KVM ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) KVM feature Selection
(ืฉืžืชืฉืž ืชืจื™ื—ื‘) User Opt-in
(ืงื—ื•ืจืž IT -ืž ื”ืจื•ืฆืช ืชื•ื™ื•ืจืฉืคื ืชืจื™ื—ื‘) Opt-in Configurable from remote IT
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.ืŸืœื”ืœ ืชื•ืžื•ืฉืจื” ืฉืžืชืฉืžื” ื™ื“ื™-ืœืข ื”ืจื“ื’ื”ืœ ืชื•ื ืชื™ื ื” ืชื•ื™ื•ืจืฉืคืื” ืชื ืœืœื•ื› Intel AMT Configuration ืฃื“ื”
(ืœื•ื”ื™ื  ืชืœื•ื›ื™ ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) Manageability Feature Selection
.Intel AMT Configuration ืฃื“ืœ ื”ื ืชืฉืž ื™ืฉืืจื” ื˜ื™ืจืคืชื” .Enter ืฉืงื”ื• Intel AMT Configuration ืจื—ื‘ ,ื™ืฉืืจื” ื˜ื™ืจืคืชื‘
.Enter ืฉืงื”ื• (ืœื•ื”ื™ื  ืชืœื•ื›ื™ ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) Manageability Feature Selection ืจื—ื‘ ,Intel AMT Configuration ื˜ื™ืจืคืชื” ืชื—ืช
ืืœ ืœื•ื”ื™ื  ืชืœื•ื›ื™ืฉ ื”ืฉื•ืจื™ืค ืชืœืจื˜ื•ื ืž ืชื•ืจืฉืคืื” ืชืจืืฉื” .ื’ืฆื•ืž Intel ME ืœืฉ ืœื•ื”ื™ื ื” ืชืœื•ื›ื™ ืชื ื•ื›ืช ื˜ื™ืจืคืช , ืชืจืฉืคื•ืืž Manageability Feature Selection ืชื•ืจืฉืคืื” ืจืฉืื›
Page 53
.ืชืจืฉืคื•ืืž ื”ื™ื”ืช
SOL/IDER
.Enter ืฉืงื”ื• SOL/IDER ืจื—ื‘ ,(ืจืฉืคื•ืืž Intel AMT ืจืฉืื›) Intel AMT Configuration ืฃื“ื‘
.SOL/IDER ืฃื“ืœ ื”ื ืชืฉืž Intel AMT Configuration ืฃื“ื”
(ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ) Username and Password
.Enter ืฉืงื”ื• (ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ) Username and Password ืจื—ื‘ ,SOL/IDER ืฃื“ื‘
ืœืคื•ื˜ืž ืฉืžืชืฉืžื” ืชื•ืžื™ื .(ืœืจื˜ื•ื ืž) DISABLED ื•ื– ืชื•ืจืฉืคื ืจื™ื“ื’ื”ืœ ืฉื™ ,*Kerberos -ื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื  ืื .SOL/IDER ืชื•ืœื™ืขืค ืจื•ื‘ืข ืฉืžืชืฉืžื” ืชื•ืžื™ื ืชื ืชืงืคืกืž ื•ื– ืชื•ืจืฉืคื
.SOL/IDER ืชื•ืœื™ืขืคื‘ ืฉืžืชืฉืž ืชื•ืžื™ื ืœืจื˜ื ืœ ื•ื ืจืฉืคืืœ IT -ื” ืœื”ื ืž ืชื•ืจืฉืคืื‘ ,Kerberos -ื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื  ืืœ ืื .Kerberos ืšืจื“
ืชื•ืจืฉืคืืจื•ืื™ืช
(ืจืฉืคื•ืืž) Enabledืื™ืจืฉืคื•ืืž ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ (ืœืจื˜ื•ื ืž) Disabled.ืื™ืœืจื˜ื•ื ืž ื”ืžืกื™ืกื• ืฉืžืชืฉืž ืืฉ
SOL
.Enter ืฉืงื”ื• SOL ืจื—ื‘ ,SOL/IDER ืฃื“ื‘
Page 54
,SOL - ื‘ ืชื›ืžื•ืช ื”ื ื™ื ืชื›ืจืขืžื” ืื .(SOL -ื‘ ืชื›ืžื•ืช ื—ื•ืงืœื” ืชื›ืจืขืž ืื) ืœื•ื”ื™ื  ืชืจืฉ ืฃื•ืกืž ืœื Intel AMT ืœืฉ ืœื”ื•ื ืž ื—ื•ืงืœ ืฃื•ืกืž ืœืฉ ื˜ืœืค/ื˜ืœืงื” ืชื ืฉื“ื—ืž ื‘ืชื ืœ ืจืฉืคืืž SOL
.ื•ืชื•ื ืจืฉืคืืœ ืœื•ื›ื™ ื•ื ื™ื ื”ื– ืšืจืข
ืชื•ืจืฉืคืืจื•ืื™ืช
(ืจืฉืคื•ืืž) Enabledืจืฉืคื•ืืž SOL (ืœืจื˜ื•ื ืž) Disabledืœืจื˜ื•ื ืž SOL
.ื”ื‘ ืฉื•ืžื™ืฉื” ืชื ืืกื•ื— ืงืจ ืืœื ,ื•ื– ื”ื ื•ื›ืช ืจื™ืกืž ื•ื ื™ื SOL ืœื•ืจื˜ื  :ื”ืจืขื”
IDER
.Enter ืฉืงื”ื• IDER ืจื—ื‘ ,SOL/IDER ืฃื“ื‘
Page 55
.ื•ืชื•ื ืจืฉืคืืœ ืœื•ื›ื™ ื•ื ื™ื ื”ื– ืšืจืข ,IDE-R -ื‘ ืšืžื•ืช ื•ื ื™ื ื—ื•ืงืœื” ืื .ืชืงื—ื•ืจืž ืงืกื™ื“ ืชื ื•ืžืชืž ,ืœื•ื”ื™ื  ืฃื•ืกืž ืชื•ืขืฆืžืื‘ Intel AMT ืœื”ื•ื ืž ื—ื•ืงืœ ืœืฉ ืœื•ื—ืชื ืจืฉืคืืž IDE-R
ืชื•ืจืฉืคืืจื•ืื™ืช
(ืจืฉืคื•ืืž) Enabledืจืฉืคื•ืืž IDER (ืœืจื˜ื•ื ืž) Disabledืœืจื˜ื•ื ืž IDER
.ื”ื‘ ืฉื•ืžื™ืฉื” ืชื ืืกื•ื— ืงืจ ืืœื ,ื•ื– ื”ื ื•ื›ืช ืจื™ืกืž ื•ื ื™ื IDER ืœื•ืจื˜ื  :ื”ืจืขื”
(ืฉื“ื—ืž ื‘ื•ืชื™ื  ื‘ืฆืž) Redirection Mode
.Enter ืฉืงื”ื• Redirection Mode ืจื—ื‘ ,SOL/IDER ืฃื“ื‘
Page 56
ืจื‘ื“ .ื”ืœืขืคื” ืœื› ื™ื ืคืœ ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืชื•ืื™ืฆื™ ืชื ื—ื•ืชืคืœ ืšื™ืจืฆ ืฃื•ืกืžื” ,ืชืœืจื˜ื•ื ืž ืชื•ืจืฉืคืื” ืื .ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืœืฉ ื”ืœื•ืขืคื” ืŸืคื•ืื‘ ืชื˜ืœื•ืฉ Legacy Redirection Mode ืชื•ืจืฉืคืื”
ืชื™ื™ืฆืงื ื•ืคื‘ ืื™ื›ืžื•ืช ืื ื™ืืฉ ,(Intel AMT 6.0 ื™ื ืคืœ) ืื™ื ืฉื™ื” SMB - ื” ื™ืคื•ืกืž .ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืชื•ืื™ืฆื™ ืœืฉ ื”ื—ื™ืชืคื‘ ืื™ื›ืžื•ืชื” ,ืื™ืฉื“ื— SMB ื™ืคื•ืกืžื• ืื™ื™ื ื•ื’ืจื ืื™ืคื•ืกืž ืจื•ื‘ืข ื“ืขื•ื  ื”ื–
.Intel MEBx ืœืฉ ื•ื– ืชื•ืจืฉืคื ืšืจื“ ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืชืื™ืฆื™ ืชื ืชื™ื ื“ื™ ืœื™ืขืคื”ืœ ืื™ื›ื™ืจืฆ ,ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืชื•ืื™ืฆื™ ืœืฉ ื”ื—ื™ืชืคื”
:ื”ืื‘ื” ื”ืขื“ื•ื”ื” ืชื’ืฆื•ืž ,ื”ื– ื‘ืฆืž ืชืจื™ื—ื‘ ืชืขื‘
.(ืœื“ื—ืž ืชืจื™ืจื‘) ืœืจื˜ื•ื ืž ืื“ื•ืง ืจื•ื“ืœ ืฉื“ื—ืž ื‘ื•ืชื™ื  ื‘ืฆืž
ืชื•ืจืฉืคืืจื•ืื™ืช
Disabled
(ืœืจื˜ื•ื ืž)
Page 57
Enabled
ืื™ื˜ืงื™ื•ืจืคื‘ SMB ื‘ืฆืž ื”ื™ื”ืฉ ื”ืžืœ ื”ื”ื– ื‘ืฆืž ื•ื”ื– .Intel MEBx - ื‘ ืจืฉืคื•ืืž ืฉื“ื—ืž ื‘ื•ืชื™ื  ืจืฉืื› ื“ื™ืžืช ื”ื—ื•ืชืค ืชืจืชื•ื  ื”ืื™ืฆื™ื”
.ืฉื“ื—ืž ื‘ื•ืชื™ื  ืœืฉ ืชื•ืœืขืคื” ื—ื•ืชืคืœ ื—ื™ืœืฆื”ืœ ื™ื“ื› ื”ื– ื‘ืฆืžืœ ื•ืงืงื“ื–ื™ (Intel AMT 6.0 ื™ื ืคืœ) ืื™ื ืฉื™ SMB ื™ืคื•ืกืž .ืื™ืžื“ื•ืง
(ืจืฉืคื•ืืž)
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,SOL/IDER ืฃื“ื‘
.Intel AMT Configuration ืฃื“ืœ ื”ื ืชืฉืž SOL/IDER ืฃื“ื”
(KVM ืชืจื•ืฆืช) KVM Configuration
.Enter ืฉืงื”ื• (KVM ืชืจื•ืฆืช) KVM Configuration ืจื—ื‘ ,Intel AMT Configuration ืฃื“ื‘
.KVM Configuration ืฃื“ืœ ื”ื ืชืฉืž Intel AMT Configuration ืฃื“ื”
(KVM ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) KVM feature Selection
.Enter ืฉืงื”ื• (KVM ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) KVM Feature Selection ืจื—ื‘ ,IKVM Configuration ืฃื“ื‘
ืชื•ืจืฉืคืืจื•ืื™ืช
(ืœืจื˜ื•ื ืž) DisabledKVM ืชื ื•ื›ืช ืœื•ืจื˜ื  (ืจืฉืคื•ืืž) EnabledKVM ืชื ื•ื›ืช ืจื•ืฉืคื
.ื”ื– ื”ืจืงืžื‘ ืœืขืคื™ ืืœ KVM . ื”ืชื•ื ืœืจื˜ื ืž ืืœื ,ื•ื– ื”ื ื•ื›ืช ืจื™ืกืž ื•ื ื™ื KVM ืœื•ืจื˜ื  :ื”ืจืขื”
(ืฉืžืชืฉืž ืชืจื™ื—ื‘) User Opt-in
.Enter ืฉืงื”ื• ( ืฉืžืชืฉืž ืชืจื™ื—ื‘) User Opt-in ืจื—ื‘ ,IKVM Configuration ืฃื“ื‘
Page 58
:ืชื•ืื‘ื” ืชื•ื™ื•ืจืฉืคืื” ืชื ืจื•ื—ื‘ืœ ืŸืชื™ื 
(KVM ืชืœืขืคื” ืœืฉ ืงื•ื—ืจืž ืชืจื™ืฆื™ืœ ืชืฉืจื“ื  ื™ืžื•ืงืž ืฉืžืชืฉืž ืชืžื›ืกื”) Local User Consent is not required for remote establishment of KVM session
(KVM ืชืœืขืคื” ืœืฉ ืงื•ื—ืจืž ืชืจื™ืฆื™ืœ ืชืฉืจื“ื  ืืœ ื™ืžื•ืงืž ืฉืžืชืฉืž ืชืžื›ืกื” ) Local User Consent is required for remote establishment of KVM session
(ืงื—ื•ืจืž IT -ืž ื”ืจื•ืฆืช ืชื•ื™ื•ืจืฉืคื ืชืจื™ื—ื‘) Opt-in Configurable from remote IT
.Enter ืฉืงื”ื• ( ืงื—ื•ืจืž IT -ืž ื”ืจื•ืฆืช ืชื•ื™ื•ืจืฉืคื ืชืจื™ื—ื‘) Opt-in Configurable from remote IT ืจื—ื‘ ,IKVM Configuration ืฃื“ื‘
Page 59
ืชื•ืจืฉืคืืจื•ืื™ืช
ืชืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืจื•ื—ื‘ืœ ืงื—ื•ืจืž ืฉืžืชืฉืž ืœืฉ ืชืœื•ื›ื™ื” ืชื ืชืœืจื˜ื ืž ื•ื– ืชื•ืจืฉืคื
.ื”ืจื™ื—ื‘ื” ืชื•ื™ื ื™ื“ืžื‘ ื˜ื•ืœืฉืœ ืœื•ื›ื™ ื™ืžื•ืงืž ืฉืžืชืฉืž ืงืจ , ื”ื– ื”ืจืงืžื‘ .ืฉืžืชืฉืž
ืชืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืจื•ื—ื‘ืœ ืงื—ื•ืจืž ืฉืžืชืฉืž ืœืฉ ืชืœื•ื›ื™ื” ืชื ืชืจืฉืคืืž ื•ื– ืชื•ืจืฉืคื
.ืฉืžืชืฉืž
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,KVM Configuration ืฃื“ื‘
.Intel AMT Configuration ืฃื“ืœ ื”ื ืชืฉืž KVM Configuration ืฃื“ื”
.Enter ืฉืงื”ื• ( ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu ืจื—ื‘ ,Intel AMT Configuration ืฃื“ื‘
.(ื™ืฉืืจ ื˜ื™ืจืคืช) Main Menu ืฃื“ืœ ื”ื ืชืฉืž Intel AMT Configuration ืฃื“ื”
Disable Remote Control of KVM Opt-In
(KVM ืœืฉ ื”ืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืœืฉ ืงื•ื—ืจืž ื”ืจืงื‘ ืœื•ืจื˜ื ) Policy
Enable Remote Control of KVM Opt-In
(KVM ืœืฉ ื”ืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืœืฉ ืงื•ื—ืจืž ื”ืจืงื‘ ืจื•ืฉืคื) Policy
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
(ืื“ื•ืง ื˜ื™ืจืคืช) Previous Menu
.Intel ื™ื“ื™-ืœืข ืŸืชื™ื  ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
*
Page 60
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Intelยฎ Fast Call
ืฅื•ื—ืž ืชืืฆืžื  VPro -ื” ืชื›ืจืขืž ืื ,ืขื•ื™ืก ืฉืงื‘ืœ ื”ืฆืงื” ืฉืžืชืฉืžืœ ืจืฉืคืืž ื”ืจื–ืขืœ Intel Fast Call ืจื•ื‘ื™ื— .VPro SKUs ืจื•ื‘ืข ื”ื ื™ืžื–ื” ื”ื ื•ื›ืช ื”ื•ื•ื”ืž ื”ืจื–ืขืœ Intelยฎ Fast Call ืขืฆื‘ืœ ื™ื“ื› ,ืชื ืขื˜ื  ืชื›ืจืขืžื” ืจืฉืื› (<Ctrl><h>) ืŸืฆื—ืœ/ืจื•ืฆื™ืงื” ืฉืงืž ืœืข ืฉื™ืงื”ืœ ืฉืžืชืฉืžื” ืชื•ืจืฉืคืื‘ ,ื”ืจื–ืขืœ Intel Fast Call ืจื•ื‘ื™ื— ืจืฉืคืืž BIOS -ื” ืื .ืชื™ื ื•ื’ืจืื” ืชืฉืจืœ
.Fast Call for Help ืจื•ื—ื‘ืœื• F12 ืฉื™ืงื”ืœ ืฅืœืžื•ืž .Intel Fast Call ืจื•ื‘ื™ื—
.ื”ื‘ ื”ื›ื™ืžืชืœ ืชื›ืจืขืžื” ืชื ืจื™ื“ื’ื™ IT -ื” ืœื”ื ืž ืจืฉืื› ืงืจ ื”ื ื™ืžื– ื”ื™ื”ืช ื•ื– ื”ื ื•ื›ืช :ื”ืจืขื”
ืชื•ืฉื™ืจื“
:ืื™ืื‘ื” ืื™ืจื‘ื“ืœ ื”ืงื•ืงื– VPro ืชื›ืจืขืž ,ื”ืœืขืคื”ื” ืชื›ืจืขืžืž Intel Fast Call ืจื•ื‘ื™ื— ืจื•ืฆื™ืœ ื”ื™ื”ื™ ืŸืชื™ื ืฉ ื™ื ืคืœ
ืจืฉืคื•ืืž ื”ื‘ื™ื‘ืก ื™ื•ื”ื™ื–
ืงื•ื—ืจืž ืจื•ื‘ื™ื— ืชื•ื™ื ื™ื“ืž
(MPS - ืœื•ื”ื™ื  ืชื•ื—ื›ื•ื  ืชืจืฉ) Management Presence Server
ืื™ื‘ื™ื›ืจืžื” ืœื› ืจื•ื‘ื™ื—
ืื .ืฉื•ืžื™ืฉืœ ืŸื™ืžื– ื”ื™ื”ื™ ื”ืจื–ืขืœ Intel Fast Call ื™ื–ื ,Full VPro - ื‘ ืชื›ืžื•ืช ืชื›ืจืขืžื” ืื .ื”ืงืคืกื ื‘ืฆืžื‘ ืชื•ื™ื”ืœ ื”ื›ื™ืจืฆ ืชื›ืจืขืžื” ,ื”ืจื–ืขืœ Intel Fast Call ืชื ืœื‘ืงืœ ืชื ืž ืœืข
.ืจืฉืคื•ืืž ื”ื™ื”ื™ ืืœ ื”ืจื–ืขืœ Intel Fast Call ื™ื–ื ,Intel Standard Manageability -ื‘ ืงืจ ืชื›ืžื•ืช ืชื›ืจืขืžื”
ืจื‘ื“ .ืชื™ื ื•ื’ืจืื” ืชืฉืจื” ืšื•ืชื‘ ืชืืฆืžื  ืชื›ืจืขืžื” ืื ืขื•ื‘ืงืœ Intel AMT -ืœ ืจืฉืคืืž ื”ื– ืจื‘ื“ .ื”ื‘ื™ื‘ืก ื™ื•ื”ื™ื– ืจืฉืคืืœ ืฉื™ , ื”ืจื–ืขืœ Intel Fast Call ืชื ืœื™ืขืคื”ืœ ื”ื™ื”ื™ ืŸืชื™ื ืฉ ื™ื ืคืœ
.ISV ืื•ืฉื™ื™ ืšืจื“ ืจื“ื’ื•ืž ื”ื–
ื”ื›ื™ืจืฆ ืšื ,ืชืจื“ื’ื•ืž ืชื•ื™ื”ืœ ืชื‘ื™ื™ื— ื”ื ื™ื BIOS -ื‘ ื”ืจื•ืงืžืฉ ื”ื—ื™ืฉื” ืจื•ื‘ืข ืชื•ื™ื ื™ื“ืžื” .ื”ืจื–ืขืœ Intel Fast Call ืชื ืœื™ืขืคื”ืœ ื”ื™ื”ื™ ืŸืชื™ื ืฉ ื™ื ืคืœ ืงื•ื—ืจืž ืจื•ื‘ื™ื— ืชื•ื™ื ื™ื“ืž ืจื•ืฆื™ืœ ืฉื™
.ื”ืจื–ืขืœ Intel Fast Call ืชื ืœื™ืขืคืžื” ืจื•ืฆื™ืงื” ืฉืงืžื‘ ืšื•ืžืชืœ BIOS -ื” ืœืข .BIOS -ื”ืž ื”ืจื–ืข ืชื—ื™ืฉ ืขื•ืฆื™ื‘ ื™ื ืคืœ ืชืจื—ื ืชื•ื™ื ื™ื“ืž ืชื•ื™ื”ืœ
.DMZ ืจื•ื–ืื‘ ืŸื›ื•ืฉ ืœื•ื”ื™ื ื” ืชื•ื—ื›ื•ื  ืชืจืฉ .ื”ืจื–ืขืœ Intel Fast Calls ืœืข ื”ื ืขื™ืฉ ืœื•ื”ื™ื  ืชื•ื—ื›ื•ื  ืชืจืฉ ืชื•ื™ื”ืœ ื‘ื™ื™ื—
.ื”ืจื–ืขืœ Intel Fast Call ืขืฆื‘ืœ ื”ืœื•ื›ื™ ืชื›ืจืขืžื” , ืื™ืžื™ื™ืงืชืž ื”ืœืื” ืื™ืื ืชื” ืœื› ืจืฉืื›
ื”ืจื–ืขืœ Intel Fast Call ืขื•ืฆื™ื‘
:ืชื•ืœืœื•ื› ื”ืœื .ื”ืจื–ืขืœ Intel Fast Call ืชื•ืœื™ืขืค ืขื•ืฆื™ื‘ืœ ืชื•ื˜ื™ืฉ ืฉื•ืœืฉ ืชื•ืžื™ื™ืง ,ื”ื ื•ื›ืชื” ืœืฉ ื”ืืœืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืจื—ืืœ
.<Ctrl><h> ืฉืงื” Dell ืœืฉ ื”ื—ื™ืชืคื” ืšืกืžื‘
.ื™ืžืขืค-ื“ื—ื” ืœื•ื—ืชืื” ื˜ื™ืจืคืชืœ ืจื•ื‘ืขืœ ื™ื“ื› <F12> ืฉืงื” Dell ืœืฉ ื”ื—ื™ืชืคื” ืšืกืžื‘
.Intel Fast Call for Help :ื”ื ื•ืจื—ืื” ืชื•ืจืฉืคืื” ืชื ืจื—ื‘
:Windows ืšื•ืชืž
.Intel AMT ืœืฉ ืื•ืฉื™ื™ื”/ืชื•ื™ื˜ืจืคื” ืœืžืก ืšืจื“ Intel Management Security Status ืชื ืœืขืคื”
.Intel AMT ื”ื™ื™ืกื™ื˜ืจื›ื” ืœื ืจื•ื‘ืข
.(ืจื‘ื—ืชื”) Connect ืœืข ืฅื—ืœ ,(ืงื•ื—ืจืž ืชื•ื™ืจื•ืฉื™ืง) Remote Connectivity ื”ื‘ื™ืชื‘
.Intel ื™ื“ื™-ืœืข ืŸืชื™ื  ื”ื– ืšืžืกืžื‘ ืขื“ื™ืžื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
*
Page 61
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ME ืœืฉ ืชื•ื™ืœืœื› ืชื•ืจื“ื’ื”
.ืชื•ื™ืœืœื›ื” ืชื•ืจื“ื’ื”ื” ืฃื“ื‘ (Intelยฎ Management Engine BIOS Extension (MEBx ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชื•ืจื“ื’ื” ืชื•ื’ืฆื•ืž ื”ืื‘ื” ื”ืœื‘ื˜ื‘
(ื”ืžืกื™ืก) Password
(ื”ืžืกื™ืก) Passwordadmin
(Intel ME ืชืžืกื™ืก ื™ื•ื ื™ืฉ) Change Intel ME Password
Change Intel ME
ืชืžืกื™ืก ื™ื•ื ื™ืฉ) Password
ืงื™ืจ
(Intel ME
(ื”ืžืกื™ืก ืชื•ื™ื ื™ื“ืž) Password Policy
* Default Password Only
(ื“ื‘ืœื‘ ืœื“ื—ืž ืชืจื™ืจื‘ ืชืžืกื™ืก)
ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืšืœื”ืžื‘
ืชืข ืœื›ื‘
Password Policy
(ื”ืžืกื™ืก ืชื•ื™ื ื™ื“ืž)
(ืชืฉืจ ืชืจื“ื’ื”) Network Setup
(ืชืฉืจ ืืฉ ืชื•ืจื“ื’ื”) Network Name Settings
(ื—ืจืืž ืืฉ) Host Nameืงื™ืจ
ืงื™ืจ
(ื™ื“ื•ืขื™ื™) Dedicated
*(ืฃืชื•ืฉืž) Shared
*(ืœืจื˜ื•ื ืž) Disabled
(ืจืฉืคื•ืืž ) Enabled
(TCP/IP ืชื•ืจื“ื’ื”) TCP/IP Settings
(ื˜ื•ื•ื—ืž LAN IPv4 ืชืจื•ืฆืช) Wired LAN IPv4 Configuration
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
ืืฉ) Domain Name
(ืื•ื—ืช
FQDN
Dynamic DNS (DNS
(ื™ืžื ื™ื“
ื‘ืฆืž) DHCP Mode
(DHCP
(ื˜ื•ื•ื—ืž LAN IPv6 ืชืจื•ืฆืช) Wired LAN IPv6 Configuration
*(ืœืจื˜ื•ื ืž) Disabled
(ืจืฉืคื•ืืž ) Enabled
ืชื•ืจืฉืคืื” ื”ืจื—ื‘ื  ืื ืงืจ ื’ืฆื•ืž ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืฃื“
.(ืจืฉืคื•ืืž ) enabled
*(ื™ืืจืงื ื”ื”ื–ืž) Random ID
Intel ID
(ื™ื ื“ื™ ื”ื”ื–ืž) Manual ID
IPv6 feature
Selection
ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘)
(IPv6
IPv6 Interface ID
ืงืฉืžืž ื”ื”ื–ืž ื’ื•ืก) Type
(IPv6
Page 62
ืชื‘ื•ืชื›) IPv6 Address
ืงื™ืจ
ืงื™ืจ
ืงื™ืจ
ืงื™ืจ
(ืืœ/ืŸื›) Y / N
(ืืœ/ืŸื›) Y / N
IPv6 Default Router
ืœืฉ ืœื“ื—ืž ืชืจื™ืจื‘ ื‘ืชื )
Preferred DNS IPv6
DNS ืชื‘ื•ืชื›) Address
Alternate DNS IPv6
DNS ืชื‘ื•ืชื›) Address
Activate Network
ื”ืฉื™ื’ ืชืœืขืคื”) Access
Unconfigure
Network Access
(ื”ืจื•ืฆืช ืืœืœ ืชืฉืจืœ ื”ืฉื™ื’)
(IPv6
(IPv6
(ืชืคื“ืขื•ืž IPv6
(ืชื™ืคื•ืœื— IPv6
(ืชืฉืจืœ
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”) Remote Setup And Configuration
(ื™ื—ื›ื•ื  ื”ืงืคืกื ื‘ืฆืž) Current Provisioning Mode
(ื”ืงืคืกื ืชืžื•ืฉืจ) Provisioning Record
(ืืœ/ืŸื›) Y / N
(ืืœ/ืŸื›) Y / N
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(Start Configuration
(ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชืœื—ืชื”)
Provisioning
Server IPv4/IPv6
ืงื™ืจ
(IPv4/IPv6
Provisioning
ืชืจืฉ) Server FQDN
ืงื™ืจ
(FQDN ื”ืงืคืกื
ืงื™ืจ
Set PID and PPS
(PPS - ื• PID ืชืจื“ื’ื”)
Delete PID and PPS
(PPS - ื• PID ืชืงื™ื—ืž)
Configuration
(ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง)
RCFG
ื”ืงืคืกื ืชืจืฉ)
TLS PSK
TLS PKI
Remote
PKI DNS Suffixืงื™ืจ
(Hash ื™ื’ื•ืก ืœื•ื”ื™ื ) Manage Hashes
(ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข ืชื•ืจื“ื’ื”) FW Update Settings
(ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข ืชื•ืจื“ื’ื”) FW Update Settings
Page 63
Local FW Update
(ื“ื™ืžืช ื—ื•ืชืค) * Always Open
(ื—ื•ืชืค ืืœ ืืœื•ืขืœ) Never Open
(ืœื‘ื’ื•ืž) Restricted
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
Intel AMT ืœืฉ ืชื™ืงืœื— ื”ืงืคืกื-ื™ืืœ ืื•ืจื’ืœ ืœื•ืœืข**
.(Management Engine (ME ืœืฉ ืชื•ื™ืขื‘ ืŸื•ืจืชืค ืจื•ื‘ืข ืงืจ ื”ื ืชืฉืž Intel ME Platform State Control
.ืชืงืคื•ืกืž ื”ื‘ื™ืชื” ืื ืงืจ ืชื™ืืจื  ื”ืงืคืกื-ื™ื ืชืจื“ื’ื”
ืŸื•ื›ื“ืข ืŸื™ื™ืคืืž) Qualifier
(ื™ืžื•ืงืž ื”ื—ืฉื•ืง
Secure FW Update
(ื—ื˜ื‘ื•ืืž ื”ื—ืฉื•ืง ืŸื•ื›ื“ืข)
ืœื“ื—ืž ืชืจื™ืจื‘ ืชืจื“ื’ื”*
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
1 2
Page 64
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
AMT ืชืจื•ืฆืช
.AMT ืœืฉ ื”ืจื•ืฆืชื” ืฃื“ื‘ (Intelยฎ Management Engine BIOS Extension (MEBx ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชื•ืจื“ื’ื” ืชื•ื’ืฆื•ืž ื”ืื‘ื” ื”ืœื‘ื˜ื‘
ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘/ืœื•ื”ื™ื  ืชืœื•ื›ื™
SOL/IDER
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(ืœืจื˜ื•ื ืž) Disabled
*(ืจืฉืคื•ืืž ) Enabled
(KVM ืชืœืขืคื”ืœ ืชืฉืจื“ื  ื”ื ื™ื ืฉืžืชืฉืž ืชืžื›ืกื”) User Consent is not required for KVM session
(KVM ืชืœืขืคื”ืœ ืชืฉืจื“ื  ืฉืžืชืฉืž ืชืžื›ืกื”) User Consent is required for KVM session
(KVM ืœืฉ ื”ืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืœืฉ ืงื•ื—ืจืž ื”ืจืงื‘ ืœื•ืจื˜ื ) Disable Remote Control of KVM Opt-In Policy
* (KVM ืœืฉ ื”ืจื™ื—ื‘ ืชื•ื™ื ื™ื“ืž ืœืฉ ืงื•ื—ืจืž ื”ืจืงื‘ ืจื•ืฉืคื) Enable Remote Control of KVM Opt-In Policy
.Clarkdale/Arrandale CPU ืชื•ื™ื”ืœ ืชื‘ื™ื™ื— ื”ืฉื™ืจื“ื” ,ืœืขืคื™ KVM -ืฉ ื™ื“ื› :ื”ืจืขื”
.(Management Engine (ME ืœืฉ ืชื•ื™ืขื‘ ืŸื•ืจืชืค ืจื•ื‘ืข ืงืจ ื”ื ืชืฉืž Intel ME Platform State Control
.ืื•ื—ืชื” ืืฉ ืชื ืชื™ื˜ืžื•ื˜ื•ื ืŸืขื•ื˜ DHCP ,(ืŸื•ื’ืจื ) Enterprise ื‘ืฆืžื‘
ืฉืžืชืฉืž ืืฉ) Username and Password
(ื”ืžืกื™ืกื•
SOL
IDER
ื‘ื•ืชื™ื  ื‘ืฆืž) Legacy Redirection Mode
(ืื“ื•ืง ืจื•ื“ืœ ืฉื“ื—ืž
(KVM ืชืจื•ืฆืช) KVM Configuration
ืชื•ื ื•ื›ืช ืชืจื™ื—ื‘) KVM feature Selection
(KVM
(ืฉืžืชืฉืž ืชืจื™ื—ื‘) User Opt-in
Opt-in Configurable from remote IT
(ืงื—ื•ืจืž IT -ืž ื”ืจื•ืฆืช ืชื•ื™ื•ืจืฉืคื ืชืจื™ื—ื‘)
ืœื“ื—ืž ืชืจื™ืจื‘ ืชืจื“ื’ื”*
Intel AMT ืœืฉ ืชื™ืงืœื— ื”ืงืคืกื-ื™ืืœ ืื•ืจื’ืœ ืœื•ืœืข**
.ืชืงืคื•ืกืž ื”ื‘ื™ืชื” ืื ืงืจ ืชื™ืืจื  ื”ืงืคืกื-ื™ื ืชืจื“ื’ื”
1 2 3
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 65
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืœ ืชื•ื˜ื™ืฉ ืœืฉ ื”ืจื™ืงืก
ืชืžืœืฉื”ืœ ืชื•ื˜ื™ืฉ ื™ืชืฉ ืŸื ืฉื™ .ืœื•ื”ื™ื  ืื•ืฉื™ื™ ืืข ื”ื™ืฆืงืืจื˜ื ื™ืืœ ืชื•ื ื›ื•ืž ื•ื™ื”ื™ Intel AMT ืชื•ืœื•ื›ื™ืฉ ื™ื ืคืœ ,ื‘ืฉื—ืžื” ืชืจื•ืฆืช ืชื ืขื•ื‘ืงืœ ืฉื™ ,ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืชืจื™ืงืก ืฃื™ืขืกื‘ ืŸื•ื“ื™ื ืฉ ื™ืคื›
:(ืจืชื•ื™ื‘ ืชื‘ื›ืจื•ืžื” ืœื ืชื‘ื›ืจื•ืž ืชื•ื—ืคื”ืž) ื”ืงืคืกืื” ืšื™ืœื”ืช
.Intel AMT ืชืœื•ื›ื™ ืืข ืื™ื‘ืฉื—ืžื”ืž ื“ื—ื ืœื›ื‘ ื“ื‘ืœื‘ ืชื—ื ื”ืขื™ื’ื ื‘ ืชืจืฉื‘ GUI ืฃื•ืกืžืž ื”ืงืคืกืื” ืšื™ืœื”ืช ืชื ืื™ืœืฉื”ืœ ืจืฉืคืืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ืจื™ืฉ โ€” ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ืจื™ืฉ
.ื”ื•ื‘ื’ ื—ืคื  ืŸื•ืกื—ืืœ USB ืŸืงืชื”ื‘ ืจืžืฉื ื• ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชื•ืจื™ืฉ ื™ื“ื™-ืœืข ืจืฆื•ื ืฉ ืฅื‘ื•ืง ืชื•ืขืฆืžืื‘ ืื™ืืœืžืชืž PID -ื”ื• PPS -ื” ืชื•ื“ืฉ
ืื™ื‘ืฉื—ืžื”ืž ื“ื—ื ืœื›ื‘ (Management Engine BIOS Extension (MEBx ืชื•ืจื“ื’ื” ืœืฉ ื”ืจื•ืฆืชื” ืชื ืชื™ื ื“ื™ ืขื‘ื•ืง (IT) ืขื“ื™ืžื” ืชื™ื™ื’ื•ืœื•ื ื›ื˜ ืœื”ื ืž โ€” MEBx ืงืฉืžืž
ื”ืจื•ืฆืชื” ืชืขื™ื‘ืง ืชื•ืจื™ืฉ ื™ื“ื™-ืœืข ื•ืจืฆื•ื ืฉ ืื™ื™ืจืžื•ื ืืคืœื ืื™ื•ื•ืช 8 -ื• ืื™ื•ื•ืช 32 ื™ื ื‘ ืชื•ื—ืชืคืž ืœืฉ ื”ื“ืœืงื” ื™ื“ื™-ืœืข ืื™ืืœืžืชืž PID -ื”ื• PPS -ื” ืชื•ื“ืฉ .Intel AMT -ืœ ืื™ื ื›ื•ืžื”
.MEBx -ื” ืงืฉืžืžื‘
ืขื’ืž ืืœืœ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Zero Touch Configuration ื•ื (RCFG - ืงื•ื—ืจืž ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Remote Configuration ืชื•ื‘ื•ืจืง ืื™ืชืขืœ ืืจืงื  โ€” TLS-PKI
Intel Management Engine BIOS - ื‘ ืื•ืฉืจ ืชื•ื™ื”ืœ ื‘ื™ื™ื— ืจื•ืฉื™ืืœ ืšื™ื•ืฉืžื” Hash -ื” .ื”ืงืคืกืื” ืชืจืฉืœ ืšื™ื•ืฉืžื” ืจื•ืฉื™ืื‘ ืฉืžืชืฉืž ื”ื– ืšื™ืœื”ืช .(ZTC -
.(Extension (MEBx
.ืื™ืื‘ื” ืื™ืคื™ืขืกื‘ ืื•ืฆืžืœ ืŸืชื™ื  ื”ืœื ืชื•ื ื•ืฉ ืชื•ื˜ื™ืฉื‘ ืฉื•ืžื™ืฉื” ืชื•ื“ื•ื ืื™ื˜ืจืค
ืฃื“ืœ ื”ืจื–ื—
ืŸื›ื•ืชื”
Page 66
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
USB ืŸืงืชื”ื‘ ืฉื•ืžื™ืฉ -- ื”ืจื•ืฆืช ืชืจื“ื’ื” ืชื•ืจื™ืฉ
ื”ืงืคืกืืœ ื”ืžืกื™ืก ื™ื•ื˜ื™ื‘ื• (PID) ื”ืงืคืกื ื”ื”ื–ืž , ื”ืžืกื™ืก ื™ื˜ืจืค ืชื™ืžื•ืงืž ืขื•ื‘ืงืœื• ืจื™ื“ื’ื”ืœ ืšืชื•ืจืฉืคืื‘ .USB ืŸื•ืกื—ื ืŸืงืชื” ืชื•ืขืฆืžืื‘ Intelยฎ AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื‘ ืŸื“ ื”ื– ืฃื™ืขืก
ืชื•ื™ืขื‘ื” ืืœืœ ,ื™ื ื“ื™ ืŸืคื•ืื‘ ืื™ื‘ืฉื—ืž ืœืฉ ื”ืจื•ืฆืช ืขื•ื‘ืงืœื• ืจื™ื“ื’ื”ืœ ืชืจืฉืคืืž USB ืชื•ืขืฆืžืื‘ ื”ืงืคืกื .USB ืชื•ืขืฆืžืื‘ ื”ืงืคืกื ืื’ ืืจืงื  ื”ื– ื‘ืฆืž .USB ืŸื ื•ื› ื—ืชืคืž ืชื•ืขืฆืžืื‘ (PPS)
.ืื™ื›ืจืข ืœืฉ ืชื™ื ื“ื™ ื”ื“ืœืงื”ืœ ืชื•ืจื•ืฉืงื”
ืŸืจืฆื™ื” ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ืœ ื”ืชื•ื ืกืคื ,ื”ืคืœื—ื•ื” ื”ืžืกื™ืกื” ืื .admin - ืŸืจืฆื™ื” ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ืœ ืชืจื“ื’ื•ืž MEBx -ื” ืชืžืกื™ืก ืื ืงืจ ืชืœืขื•ืค USB ืชื•ืขืฆืžืื‘ ื”ืงืคืกื :ื”ืจืขื”
.CMOS - ื” ืกื•ืคื™ื ื™ื“ื™-ืœืข
ืœืฉ ืšื™ืœื” ืฃื“ื‘ ืŸื™ื™ืข ,(Altirisยฎ Dellโ„ข Client Manager (DCM - ื‘ ืฉื•ืžื™ืฉื” ืœืข ื˜ืจื•ืคืž ืจื•ืื™ืชืœ .USB ืŸื ื•ื› ื—ืชืคืž ืชื•ืขืฆืžืื‘ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืœ ื™ืกื•ืคื™ื˜ ืšื™ืœื” ืŸืœื”ืœ
ืŸืงืชื”
.USB
.ืœื•ื”ื™ื  ืฃื•ืกืž ืืข ื‘ืฉื—ืžืœ USB ืŸื ื•ื› ื—ืชืคืž ืกื™ื ื›ืž IT ื™ืื ื›ื˜
.ืฃื•ืกืžื” ืšืจื“ (SCS) ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืชืจืฉืž ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืœืฉ ืชื•ื™ืžื•ืงืž ืชื•ืžื•ืฉืจ ืฉืงื‘ืž ื™ืื ื›ื˜ื”
:ืชื•ืื‘ื” ืชื•ืœื•ืขืคื” ืชื ืขืฆื‘ืž SCS -ื”
.PPS - ื• PID , ืชื•ืืžืกื™ืก ืœืฉ ืชื•ืžื™ืืชืžื” ืชื•ื›ืจืขื” ืชื ืงื™ืคืž
.ื•ืœืฉ ืื™ื ื•ืชื ื” ื“ืกืžื‘ ื”ื– ืขื“ื™ืž ืŸืกื—ืืž
.ืœื•ื”ื™ื ื” ืฃื•ืกืžืœ ืขื“ื™ืžื” ืชื ืจื™ื–ื—ืž
.USB - ื” ืŸื ื•ื› ื—ืชืคืžื‘ setup.bin ืฅื‘ื•ืงืœ PPS -ื”ื• PID - ื” , ื”ืžืกื™ืกื” ืชื•ื›ืจืข ืชื ื‘ืชื•ื› ืœื•ื”ื™ื ื” ืฃื•ืกืž
:ืชื•ืื‘ื” ืชื•ืœื•ืขืคื” ืชื ืขืฆื‘ืž ื™ืื ื›ื˜ื” ,ืŸื›ืž ืจื—ืืœ .Intel AMT ืชื•ืจืฉืคื ืืข ืื™ืฉื“ื— ืื™ื‘ืฉื—ืž ืื™ืืฆืžื  ื•ื‘ืฉ ื”ื ื›ื”ื” ืจื•ื–ืืœ USB - ื” ืŸื ื•ื› ื—ืชืคืž ืชื ื—ืงื•ืœ ื™ืื ื›ื˜ื”
.ืšืจื•ืฆ ืฉื™ ืื , ืืชื•ื ื‘ื™ื›ืจืžื• ื”ื–ื™ืจืื”ืž ืื™ื‘ืฉื—ืžื” ืชื ืื™ืฆื•ืž
.ื‘ืฉื—ืžืœ USB -ื” ืŸื ื•ื› ื—ืชืคืž ืชื ืกื™ื ื›ืž
.ื‘ืฉื—ืžื” ืชื ืœื™ืขืคืž
.USB - ื” ืŸื ื•ื› ื—ืชืคืž ืชื ื”ื”ื–ืž ื‘ืฉื—ืžื” ืœืฉ BIOS -ื”
.7 ื‘ืœืฉืœ ืจื•ื‘ืข .ืŸื ื•ื›ื” ื—ืชืคืž ืชืœื™ื—ืชื‘ setup.bin ืฅื‘ื•ืง ืฉืคื—ืž BIOS -ื” ,ืืฆืžื  ืื
.ืื™ืจืชื•ื ื” ืื™ื‘ืœืฉื”ืž ืืœืขืชื” .ื‘ืฉื—ืžื” ืชื ืฉื“ื—ืž ืœืขืคื” ,setup.bin ืฅื‘ื•ืง ื•ื USB ืŸื ื•ื› ื—ืชืคืž ืืฆืžื  ืืœ ืื
.ื•ืฉื—ืจืชื™ ืชื•ื™ื˜ืžื•ื˜ื•ื ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืฉ ื”ืขื“ื•ื” ื’ื™ืฆืž ื‘ืฉื—ืžื” ืœืฉ BIOS -ื”
:ืชื•ืื‘ื” ืชื•ืœื•ืขืคื” ืชื ืขืฆื‘ืž ืšื™ืœื”ืชื” .ืŸื•ืจื›ื™ื–ื” ืšื•ืชืœ ืชืืจืงื  setup.bin ืฅื‘ื•ืงื‘ ื”ื ื•ืฉืืจื” ื”ื ื™ืžื–ื” ื”ืžื•ืฉืจื”
.ืฅื‘ื•ืงื” ืชืจืชื•ื› ืชืžื•ืฉืจ ืชื•ืžื™ื
.ื”ืื‘ื” ื”ื ื™ืžื–ื” ื”ืžื•ืฉืจื” ืจื•ืชื™ื
.ื‘ื•ืฉ ื”ื‘ ืฉืžืชืฉื”ืœ ื”ื™ื”ื™ ืจืฉืคื ื™ืืฉ ื™ื“ื› ืœื˜ื•ื‘ืž ืชื™ื—ื›ื•ื ื” ื”ืžื•ืฉืจื” ืฃืงื•ืช , ื—ื™ืœืฆืž ืšื™ืœื”ื” ืื
MEBx -ื” ืœืฉ ืื™ืจื˜ืžืจืคื” ืงื•ืœื‘ืœ ืŸื•ืจื›ื™ื–ื” ืชื‘ื•ืชื› ืชื ืกื™ื ื›ืž ืšื™ืœื”ืชื”
.
.MEBx -ืœ ืืจื•ืง ืšื™ืœื”ืชื”
.ื”ืžื•ืฉืจื” ืชื ื“ื‘ืขืž MEBx
.ื”ื’ื•ืฆืชืœ ื”ืžืœืฉื” ืชืขื“ื•ื” ื‘ืชื•ื› MEBx
.ื™ื ื•ื’ืจื ื‘ืฆืž ืœืฉ ื”ื‘ื™ื‘ืกื‘ ืื™ืฉืžืชืฉืžืœ ื”ืฆืคื”ืœ ืŸื›ื•ืžื• ื”ืจื“ื’ื” ื‘ืฆืžื‘ ืชืขื› ืืฆืžื  ื‘ืฉื—ืžื” .ื‘ืฉื—ืžื” ืชื ื”ื‘ื›ืž IT - ื” ื™ืื ื›ื˜
.ื“ื—ื ื‘ืฉื—ืžืž ืจืชื•ื™ ืฉื™ ืื 5 ื‘ืœืฉ ืœืข ืจื•ื–ื—
.ืœื•ื”ื™ื ื” ืฃื•ืกืž ืงืคืกืœ ื”ื ืค ,USB ืŸื ื•ื› ื—ืชืคืž ืชื•ืขืฆืžืื‘ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืœืข ืฃืกื•ื  ืขื“ื™ืž ืชืœื‘ืงืœ
USB ืŸื ื•ื› ื—ืชืคืž ืชื•ืฉื™ืจื“
:Intel AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืœ ืฉืžืฉืœ ืœื›ื•ื™ืฉ ื™ื“ื› ืชื•ืื‘ื” ืชื•ืฉื™ืจื“ื‘ ื“ื•ืžืขืœ ื‘ื™ื™ื— USB - ื” ืŸื ื•ื› ื—ืชืคืž
.MB 16 -ืž ืœื•ื“ื’ ืชื•ื™ื”ืœ ื‘ื™ื™ื—
.FAT32 ื•ื FAT16 ืื™ืฆื‘ืง ืชื›ืจืขืžื‘ ื˜ืžืจื•ืคืž ืชื•ื™ื”ืœ ื‘ื™ื™ื—
.KB 1 ืชื•ื™ื”ืœ ื‘ื™ื™ื— ืจื•ื˜ืงืกื” ืœื“ื•ื’
.USB - ื” ืŸื ื•ื› ื—ืชืคืžืž ืœื—ืชืืœ ืŸืชื™ื  ืืœ
.ืชืจื—ื ื”ืจื˜ืž ืœื›ืœ ืืœื• ,AMT ืชืงืคืกืืœ ื“ืขื•ื  USB -ื” ืŸื ื•ื› ื—ืชืคืž
.ืจื—ื ื•ื ืงื•ื—ืž ,ืจืชืกื•ืž ืื ืŸื™ื‘ ,ืจื—ื ืฅื‘ื•ืง ืœื› ืœื™ื›ื™ ืืœ USB -ื” ื—ืชืคืž
(Dellโ„ข Optiplexโ„ข 980 ื•ื ืื“ื•ืง ืจื•ื“ืž BIOS ืจื•ื‘ืข ) USB - ื” ืŸื ื•ื› ื—ืชืคืžื‘ ืชื—ื•ื ืฉ ืŸื•ืฉืืจื” ืฅื‘ื•ืงื” ืชื•ื™ื”ืœ ื‘ื™ื™ื— setup.bin ืฅื‘ื•ืงื”
Dell ื•ื Dellโ„ข Latitudeโ„ข E6410 / E6410 ATG / E6510 ื•ื UEFI BIOS ืจื•ื‘ืข) ื”ื ื•ื™ืœืขื” ื”ื™ื™ืจืคืกื‘ ืชื•ื™ื”ืœ ื‘ื™ื™ื— setup.bin ืฅื‘ื•ืงื”
(Precisionโ„ข Mobile Workstation M4500
ืŸื›ื•ืชื”
ืฃื“ืœ ื”ืจื–ื—
Page 67
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
USB ืŸืงืชื” ืšื™ืœื”
ืชื•ืขืฆืžืื‘ Intelยฎ AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ืœ ืšื™ืœื”ื” ืชื ืงืคืกืž ื”ื– ืฃื™ืขืก .(Dellโ„ข Client Management (DCM ืื•ืฉื™ื™ื” ืื™ื” ืชืงืคื•ืกืžืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืฃื•ืกืž ืชืœื™ื‘ื—
.ื™ืฉื™ืœืฉ ื“ืฆ ื™ืงืคืก ืšืจื“ ืชื•ื ื™ืžื– ืชื•ืจื—ื ืชื•ืœื™ื‘ื— ืจืคืกืž ,ืšืžืกืžื‘ ืจืชื•ื™ ืื“ืงื•ืž ืจื›ื–ื•ื”ืฉ ื™ืคื› .DCM ืชืœื™ื‘ื—
ืชื•ืจื™ืฉ ืฃื“ื‘ ืชื•ืžื•ืฉืจื” ืชื•ืฉื™ืจื“ื‘ ื“ื•ืžืขืœ ื‘ื™ื™ื—ืฉ USB ืŸื•ืกื—ื ืŸืงืชื” ืฉืจื“ื  ,ืšื› ืœืข ืฃืกื•ื  .ื”ื– ืšื™ืœื”ืชื‘ ืœื™ื—ืชืชืฉ ื™ื ืคืœ ,DNS -ื” ืชืจืฉ ื™ื“ื™ -ืœืข ื”ืืจื™ื™ืฉ ืšื› ื‘ืฉื—ืžื” ืชื ืจื™ื“ื’ื”ืœ ืฉื™
ืชืจื“ื’ื”
ืŸืงืชื”ื‘ ืฉื•ืžื™ืฉ -- ื”ืจื•ืฆืช
.USB
ืชืื– ืชื•ืฉืขืœ ืšื™ืœืข ื”ื™ื”ื™ืฉ ืŸื›ืชื™ื™ , ืœื•ื—ืชื ืŸื•ื’ื› ,ื•ื”ืฉืž ืขืฆื‘ืœ ื‘ืฉื—ืžืœ ื”ืจื•ืช ืื ืื™ืชืขืœ , ื”ืฉืขืžืœ . ืชืžื ืŸืžื–ื‘ ืชืœืขื•ืค ื•ื ืชื™ืžื ื™ื“ ื“ื™ืžืช ื”ื ื™ื ืื™ื”ืฉ ื”ื–ื› ืื•ื” ืœื•ื”ื™ื ื” ืชื ื›ื•ืช ื™ืคื•ื :ื”ืจืขื”
.ืœืขืคื™ืฉ ื™ื“ื› ื‘ื•ืฉ
.ื“ืฆื‘ ื•ืชื•ื ื—ื ื” ืŸื›ืž ืจื—ืืœื• ืŸื•ืกื—ื ื™ืขืฆืžื ืชื™ื•ื•ืช ืืœืœื• FAT16 ืื™ืฆื‘ืงื” ืชื›ืจืขืžื‘ USB ืŸืงืชื” ื˜ืžืจืค
.(ืœื—ืชื”) Start ื˜ื™ืจืคืชื” ืšืจื“ ื•ื ื”ื“ื•ื‘ืขื” ืŸื—ืœื•ืฉ ืœืžืก ืœืข ืื™ื™ืžืขืค ื”ืฆื™ื—ืœ ื™ื“ื™-ืœืข Altirisยฎ Dell Client Manager ืื•ืฉื™ื™ื” ืชื ื—ืชืค
.Altiris Console ืชื ื—ื•ืชืคืœ ื™ื“ื› ,ื™ืœืืžืฉื” ื˜ื•ื•ื™ื ื” ื˜ื™ืจืคืชืž AMT Quick Start ืจื—ื‘
Page 68
.Intel AMT Getting Started ืขื˜ืงืžื” ืชื ื‘ื™ื—ืจื”ืœ ื™ื“ื› <+> ืœืข ืฅื—ืœ
Page 69
.Section 1. Provisioning ืขื˜ืงืžื” ืชื ื‘ื™ื—ืจื”ืœ ื™ื“ื› <+> ืœืข ืฅื—ืœ
Page 70
.(Basic Provisioning (without TLS ืขื˜ืงืžื” ืชื ื‘ื™ื—ืจื”ืœ ื™ื“ื› <+> ืœืข ืฅื—ืœ
Page 71
.(DNS ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Step 1. Configure DNS ืจื—ื‘
."ProvisionServer" -ื› DNS -ื‘ ืื•ืฉืจ ืชื•ื™ื”ืœ ื‘ื™ื™ื— out-of-band ืœื•ื”ื™ื  ืŸื•ืจืชืค ืŸืงืชื•ืž ื•ื‘ืฉ ืชื•ืขื“ื•ื”ื” ืชืจืฉ
Page 72
ื”ืจื“ื’ื”ื” ืชืจืฉ ืœื ื”ื ื•ื›ื  ื”ืจื•ืฆื‘ ื—ื ืขืคืž ืื•ื”ืฉื• ProvisionServer - ื” ืšืจืข ืชื ืœืœื•ื› DNS -ื”ืฉ ืื“ื•ื•ืœ ื™ื“ื› DNS Configuration ืšืกืžื‘ (ื”ืงื™ื“ื‘) Test ืœืข ืฅื—ืœ
.Intel ืœืฉ (SCS) ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื•
Page 73
.ืชืขื› ืชื™ืืจื  Intel SCS -ื”ื• ProvisionServer -ื” ืจื•ื‘ืข IP - ื” ืชื‘ื•ืชื›
Page 74
.(ื™ื•ืœื™ื’ ืชื•ืœื•ื›ื™) Step 2. Discovery Capabilities ืจื—ื‘
Page 75
.(ืœื—ื”) Apply ืœืข ืฅื—ืœื• Disabled ื“ืฆืœืฉ ืŸื•ืžื™ืกื” ืชื‘ื™ืช ืœืข ืฅื—ืœ ,(ืœืจื˜ื•ื ืž) Disabled ืื™ื” ื”ืจื“ื’ื”ื” ืื .(ืจืฉืคื•ืืž) Enabled ืื™ื” ื”ืจื“ื’ื”ื”ืฉ ืื“ื•
Page 76
.(Intel AMT ืชืœื•ื›ื™ ืืข ืื™ื‘ืฉื—ืž ืชื’ืฆื”) Step 3. View Intel AMT Capable Computers ืจื—ื‘
Page 77
.ื•ื– ื”ืžื™ืฉืจื‘ ืื™ืืจื  ืชืฉืจื‘ Intel AMT ืชืœื•ื›ื™ ืืข ืื™ื‘ืฉื—ืžื” ืœื›
Page 78
.(ืœื™ืคื•ืจืค ืชืจื™ืฆื™) Step 4. Create Profile ืจื—ื‘
Page 79
.ืฉื“ื— ืœื™ืคื•ืจืค ืฃื™ืกื•ื”ืœ ื™ื“ื› ''+" ืŸืžื™ืกื” ืœืข ืฅื—ืœ
Page 80
ื”ืœืง ื”ืงื•ื–ื—ืช ืืฉืœ ,ื”ืœื™ื’ืจ ื”ืžืกื™ืก ืจื™ื“ื’ืž ืชื›ืจืขืžื” ืœื”ื ืž .ื”ืžืกื™ืกื” ืืข ื“ื—ื™ ืœื™ืคื•ืจืคื” ืจื•ืื™ืชื• ืืฉ ืชื ืชื•ื ืฉืœ ืชื›ืจืขืžื” ืœื”ื ืž ืชื•ืจืฉืคืื‘ ,(ื™ืœืœื›) General ื”ื™ื™ืกื™ื˜ืจื›ื‘
.ื”ืฉื“ื— ื”ืžืกื™ืก ื“ืœืงื”ื• (ื™ื ื“ื™) manual ืชื•ืจืฉืคืื” ืŸืฆื—ืœื‘ ืจื—ื‘ .ื“ื™ืชืขื‘
Page 81
ืจื™ื“ื’ืช ืื .IDE Redirection - ื• Ping, VLAN, WebUI, Serial over LAN ืชื•ื‘ื•ืฉืช ืจืฉืคืืœ ืชื•ืจืฉืคืื” ืชื ืชืงืคืกืž (ืชืฉืจ) Network ื”ื™ื™ืกื™ื˜ืจื›ื”
.MEBx -ื‘ ืื’ ืชื•ื ื™ืžื– ื”ืœืื” ืชื•ืจื“ื’ื”ื” ืœื› ,Intel AMT ืชื ืชื™ื ื“ื™
ืืฉ ืœืœื•ื› ,ืื™ืฉืจื“ื  ืื™ืจื—ื ืขื“ื™ืž ื™ืขื˜ืง ืจืคืกืž , ืชืจืฉืคื•ืืž ื•ื– ืชื•ืจืฉืคื ืื .TLS ืจืฉืคืืœ ืชืœื•ื›ื™ื” ืชื ืชืงืคืกืž (TLS (Transport Layer Security ื”ื™ื™ืกื™ื˜ืจื›ื”
.ืจื•ืฉื™ื ืชื™ื ื‘ืชื• CA ื’ื•ืก ,CA ืœืฉ ืฃืชื•ืฉืž ืืฉ ,(CA) ืื™ืจื•ืฉื™ืื” ืชื•ืฉืจ ืชืจืฉ
ื”ืฉื™ื’ื” ืชื•ืืฉืจื” ืชื ืจื™ื“ื’ื”ืœื• ืื™ืฉื“ื— ืื™ืฉืžืชืฉืž ืฃื™ืกื•ื”ืœ ื™ื“ื› ืื’ื• ,ื”ื– ืœื™ืคื•ืจืคืœ ืจื‘ื› ืื™ื›ื™ื•ืฉืžื” ืื™ืฉืžืชืฉืž ืชืจื™ืงืกืœ ืชืฉืžืฉืž (ื”ืฉื™ื’ ืชืจืงื‘ ืชืžื™ืฉืจ) ACL ื”ื™ื™ืกื™ื˜ืจื›ื”
.ืื”ืœืฉ
Page 82
Idle ืชืจื“ื’ื” ืื’ ื•ืžื› Intel AMT ืจื•ื‘ืข ื”ื ื™ืฉื” ื™ื‘ืฆืž ืชืจื™ื—ื‘ืœ ื”ืจื•ืฆืช ืชืขื™ื‘ืง ืชื•ื™ื•ืจืฉืคื ืชืœืœื•ื› (ืœืžืฉื— ืชื›ื™ืจืฆ ืชื•ื™ื ื™ื“ืž) Power Policy ื”ื™ื™ืกื™ื˜ืจื›ื”
.ืื™ื™ื‘ื˜ื™ืž ืื™ืขื•ืฆื™ื‘ ืชืœื‘ืงืœ ,0 -ื› ืชื•ืœื™ืขืค ืจืกื•ื— ืœืฉ ืŸืžื– ืงืกืค ื“ื™ืžืช ืจื™ื“ื’ื”ืœ ืฅืœืžื•ืž .(ืชื•ืœื™ืขืค ืจืกื•ื— ืœืฉ ืŸืžื– ืงืกืค) Timeout
.E-Star 4.0 ืืื•ืช ืจืืฉื™ื”ืœ ื‘ืฉื—ืžื” ืœืฉ ืชืœื•ื›ื™ื” ืœืข ืขื™ืคืฉื”ืœ ื”ื™ื•ืฉืข ( ืœืžืฉื— ืชื›ื™ืจืฆ ืชื•ื™ื ื™ื“ืž) Power Policy ื”ื™ื™ืกื™ื˜ืจื›ื” ืจื•ื‘ืข ื”ืจื“ื’ื”ื” :ื”ืืจืชื”
.(ื”ื—ื˜ื‘ื ืชื•ื—ืชืคืž ืชืงืคื”) Step 5. Generate Security Keys ืจื—ื‘
Page 83
.(USB ื—ืชืคืžืœ ื”ื—ื˜ื‘ื ืชื•ื—ืชืคืž ืื•ืฆื™ื™) Export Security Keys to USB Key ืœืข ืขื™ื‘ืฆืžืฉ ืฅื—ื” ืืข ืœืžืกื” ืชื ืจื—ื‘
Page 84
.Generate keys before export ืชื•ืจืฉืคืื” ืŸืฆื—ืœ ืชื ืจื—ื‘
Page 85
.50 ืื™ื” ืœื“ื—ืžื” ืชืจื™ืจื‘ .(ืื”ืœ ืงืคืกืœ ืฉื™ืฉ ืื™ื‘ืฉื—ืžื” ืจืคืกืžืœ ืืืชื”ื‘) ืงื™ืคื”ืœ ืฉื™ืฉ ืชื•ื—ืชืคืžื” ืจืคืกืž ืชื ื“ืœืงื”
.ื”ื‘ื™ื‘ืกื” ืจื•ื‘ืข ื”ืฉื“ื—ื” Intel ME ืชืžืกื™ืก ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื‘ืง .admin ืื™ื” Intel ME ืœืฉ ืœื“ื—ืžื” ืชืจื™ืจื‘ ืชืžืกื™ืก
.(ื”ืงืคื”) Generate ืŸืฆื—ืœืœ ืœืืžืฉืž ืจื•ืฉื™ืง ืขื™ืคื•ืž ,ื—ืชืคืžื” ืชืจื™ืฆื™ ืจื—ืืœ .(ื”ืงืคื”) Generate ืœืข ืฅื—ืœ
Page 86
.Provisioning Server -ื‘ USB ืจื‘ื—ืž ืšื•ืชืœ ืื›ืœ ืื“ื•ืง ืชื˜ืžืจื™ืคืฉ USB -ื” ืŸืงืชื” ืชื ืกื ื›ื”
ืชืจื™ืจื‘ื› ื”ื”ื•ื–ืž USB -ื” ืŸืงืชื” .USB -ื” ืŸืงืชื”ืœ setup.bin ืฅื‘ื•ืงื” ืชื ื“ื™ืจื•ื”ืœ ื™ื“ื› (USB ื—ืชืคืž ืฅื‘ื•ืง ืชื“ืจื•ื”) Download USB key file ืจื•ืฉื™ืงื” ืœืข ืฅื—ืœ
.USB - ื” ืŸืงืชื”ื‘ ืฅื‘ื•ืงื” ืชื ืจื•ืžืฉ .ืœื“ื—ืž
.ื•ื‘ setup.bin ืฅื‘ื•ืงื” ืชืจื™ืžืฉ ื™ื ืคืœ USB - ื” ืŸืงืชื” ืชื ืฉื“ื—ืž ื˜ืžืจืคืœ ืฉื™ ,ืื™ืคืกื•ื  ืชื•ื—ืชืคืžื‘ ืšืจื•ืฆ ื”ื™ื”ื™ ื“ื™ืชืขื‘ ืื :ื”ืจืขื”
Page 87
.(ืฅื‘ื•ืง ืชื“ืจื•ื” ) File Download ื—ื™ืฉ-ื•ื“ื” ืชื‘ื™ืชื‘ ( ื”ืจื™ืžืฉ) Save ืœืข ืฅื—ืœ
.ืจื•ืžืฉ ืœืข ืฅื—ืœ .USB -ื” ืŸืงืชื”ืœ ืœื™ื‘ื•ืž (:ื‘ ื”ืจื™ืžืฉ) :Save in ืœืฉ ืื•ืงื™ืžื”ืฉ ืื“ื•
.(ื”ืžืœืฉื•ื” ื”ื“ืจื•ื”) Download Complete ื—ื™ืฉ-ื•ื“ื” ืชื‘ื™ืชื‘ (ื”ืจื™ื’ืก) Close ืœืข ืฅื—ืœ
.ืŸื ื•ื›ื” ืœืฉ ืจื™ื™ืกื” ืŸื•ืœื—ื‘ setup.bin ืฅื‘ื•ืงื” ืชื ืชื•ืืจืœ ืŸืชื™ื  ืชืขื›
Page 88
.Altiris Console ืœื ืจื•ื–ื—ืœ ื™ื“ื› ืŸื ื•ื›ื” ืจื™ื™ืก ืœืฉื• Export Security Keys to USB Key ืชื•ื ื•ืœื—ื” ืชื ืจื•ื’ืก
ื”ืขื“ื•ื”ื” ื”ืขื™ืคื•ืžื• ื“ื™ื™ืž ื”ื”ื•ื–ืž USB -ื” ืŸืงืชื” .ื‘ืฉื—ืžื” ืชื ืœืขืคื”ื• ืŸืงืชื”ื” ืชื ืกื ื›ื” ,ื‘ืฉื—ืžื” ืœื USB - ื” ืŸืงืชื” ืชื ื—ืง
))ืืœ/ืŸื›( ืชื™ื˜ืžื•ื˜ื•ื ื”ืงืคืกืื‘ ืšืฉืžื”( )Continue with Auto Provisioning (Y/N
.(ืŸื›) <y> ืฉืงื”
)...ืชื›ืจืขืžื” ืœื•ื—ืชืื‘ ืšื™ืฉืžื”ืœ ื™ื“ื› ื•ื”ืฉืœื› ืฉืงืž ืœืข ืฅื—ืœ( ...Press any key to continue with system boot
Page 89
.ืœื•ื”ื™ื ื” ืชืจืฉ ืœื ืจื•ื–ื—ื• ื‘ืฉื—ืžื” ืชื ื”ื‘ื› , ื”ืœื•ืขืคื” ืชืžืœืฉื” ืจื—ืืœ
.(ืชื•ื™ื˜ืžื•ื˜ื•ื ืื™ืœื™ืคื•ืจืค ืชื•ืืฆืงื” ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืง) Step 6. Configure Automatic Profile Assignments ืจื—ื‘
Page 90
ืจื•ื‘ืข ืชื•ืจื—ืื” ืชื•ืจื“ื’ื”ื” ืœืฉ ื”ืจื•ืฆืชื” ืชื ืขื‘ืง .ืŸื›ืœ ืื“ื•ืง ืชืจืฆื™ืฉ ืœื™ืคื•ืจืคื” ืชื ืจื—ื‘ ,+Intel AMT 2.0 ืชื—ืชืคื ื” ื”ืžื™ืฉืจื‘ .(ืจืฉืคื•ืืž) Enabled ืื™ื” ื”ืจื“ื’ื”ื”ืฉ ืื“ื•
.ื”ื‘ื™ื‘ืกื”
Page 91
.(ื”ืงืคืกื ืšื™ืœื”ืช ืจื•ื˜ื™ื ) Step 7. Monitor Provisioning Process ืจื—ื‘
Page 92
ื”ื ืชืฉืž ืชื›ืจืขืžื” ื‘ืฆืž ืŸื›ืž ืจื—ืืœ ,(ื”ืงืคืกื-ื™ื) Unprovisioned ืื•ื” ื‘ืฆืžื” ื”ืœื™ื—ืชื‘ .ืชื•ื›ืจืขืžื” ืชืžื™ืฉืจื‘ ืขื™ืคื•ื”ืœ ืื™ืœื™ื—ืชืž ืชื•ื—ืชืคืžื” ื•ืœื—ื•ื” ืืจื•ื‘ืขืฉ ืื™ื‘ืฉื—ืžื”
.ืšื™ืœื”ืชื” ืฃื•ืกื‘ (ื”ืงืคืกื ืœื‘ืงืž ) Provisioned -ืœ ื”ื ืชืฉืž ืื•ื” ืฃื•ืกื‘ืœื• ( ื”ืงืคืกืื‘) In provisioning -ืœ
Page 93
.(ืื™ืœื™ืคื•ืจืค ืชื•ืืฆืงื” ืจื•ื˜ื™ื ) Step 8. Monitor Profile Assignments ืจื—ื‘
Page 94
.(ืœื™ืคื•ืจืค ืืฉ) Profile Name - ื• FQDN, UUID ืชื•ื“ื•ืžืขื‘ ื”ื”ื•ื–ืž ื‘ืฉื—ืž ืœื› .ื”ืžื™ืฉืจื‘ ืื™ืขื™ืคื•ืž ืื™ืœื™ืคื•ืจืค ืื”ืœ ื•ืฆืงื•ื”ืฉ ืื™ื‘ืฉื—ืžื”
Page 95
ื™ื‘ืฉื—ืž ืœื›) All configured Intel AMT computers -ื‘ (ืื™ืคืกื•ื) Collections ื”ื™ื™ืงื™ืชื‘ ืื™ืืจื  ืื” , ื”ืงืคืกื ืื™ืœื‘ืงืž ืื™ื‘ืฉื—ืžื”ืฉ ืจื—ืืœ
.(ืชืจื“ื’ื•ืž ืืชืจื•ืฆืชืฉ Intel AMT
Page 96
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 97
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ืชื›ืจืขืž ืชืกื™ืจืค
Intel Active Management .ื‘ืœื•ืฉืžื” Intelยฎ 82566DM NIC -ื‘ ืฉืžืชืฉื” .ืชืฉืจืœื• ืœืžืฉื— ืจื•ืงืžืœ ื‘ืฉื—ืžื” ืชื ืจื‘ื— ,ืฉืžืชืฉืž ืจื•ื‘ืข ื‘ืฉื—ืž ืกื•ืจืคืœ ืŸื›ื•ืž ื”ืชืืฉ ืขื’ืจื‘
.ืจื—ื NIC ืŸื•ืจืชืค ืฃื ืืข ืœืขื•ืค ื•ื ื™ื (Technology (Intel AMT
ืฉืžืชืฉืžื” ืœืข) ืชืจืฉื” ืœื Hello ืชืขื“ื•ื” ื—ืœื•ืฉ Intel AMT ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืžื” , ื”ื– ืชืจืฉ ืืฆื•ืž ื‘ืฉื—ืžื” ืื .(SCS) ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืชืจืฉ ื“ื™ืž ืฉืคื—ืž ืื•ื” ,ื‘ืฉื—ืžื” ืชืœืขืคื” ืืข
.(Intel Activator ืชื•ืขืฆืžืื‘ ื•ื MEBx ืšืจื“ ืชืฉืจ ืชืฉื™ื’ ื”ืœื™ื—ืช ืœื™ืขืคื”ืœ
ืœืฉ IP -ื” ืชื•ื‘ื•ืชื› ืชื ืŸื™ื–ื”ืœ ืฉื™ ,ืื™ื ื™ืžื– ืื ื™ื DNS -ื• DHCP ืื .ืื™ื ื™ืžื– ืชื•ื™ื”ืœ ืื™ื‘ื™ื™ื— DNS -ื• DHCP ,ื—ื™ืœืฆื™ ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืชืจืฉ ืœืฉ ื™ื˜ืžื•ื˜ื•ืื” ืฉื•ืคื™ื—ื”ืฉ ื™ื“ื›
.Intel AMT ืชืœื•ื›ื™ ืืข ืื™ื‘ืฉื—ืž ืœืฉ MEBx - ืœ (SCS) ื”ืจื•ืฆืชื” ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ื™ืชืจืฉ
:ืื‘ื” ืขื“ื™ืžื” ืชื ืชืœืœื•ื› Hello -ื” ืชืขื“ื•ื”
(PID) ื”ืงืคืกื ื”ื”ื–ืž
(UUID) ื™ืœืกืจื‘ื™ื ื•ื ื™ื“ื•ื—ื™ื™ ื”ื”ื–ืž
(IP ืชื‘ื•ืชื›) IP Address
(FW) ื”ื—ืฉื•ืงื• ROM ืœืฉ ืชื•ืืกืจื’ ื™ืจืคืกืž
ืจื•ื‘ื™ื— ืื•ื–ื™ืœ ื™ื“ื› Hello -ื” ืชืขื“ื•ื”ื‘ืฉ ืขื“ื™ืžื‘ ืฉืžืชืฉืž SCS -ื” .ื”ืขื“ื•ื”ื” ืชื ืจื“ืฉืž ื‘ืฉื—ืžื”ืฉ ืŸื™ื™ืฆืž ืจืฉื ื‘ื•ืฉืž ืŸื•ื ื’ื ืž ืŸื™ื . ื”ืฆืงื” ืฉืžืชืฉืžืœ ื”ืคื•ืงืฉ Hello -ื” ืชืขื“ื•ื”
.TLS -ื‘ ื”ื›ื™ืžืช ื”ื ืฉื™ ืื ,(TLS Pre-Shared key (PSK ื”ื ืคืฆื” ืชืœื™ื‘ื— ืชื•ืขืฆืžืื‘ Intel AMT -ื” ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืžืœ (Transport Layer Security (TLS TLS Pre-Master ืงื™ืคื”ืœ ื™ื“ื› PID - ื‘ื• PPS -ื‘ ืฉืžืชืฉืžื• ื”ืงืคืกืื” ืชืจืฉ ืœืฉ ืื™ื ื•ืชื ื” ื“ืกืžื‘ (PPS) ื”ืงืคืกืืœ ื”ืžืกื™ืกื” ื™ื•ื˜ื™ื‘ ืชื ืฉืคื—ืœ ื™ื“ื› PID - ื‘ ืฉืžืชืฉืž SCS -ื”
HTTP -ื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื  ื™ื–ื ,TLS -ื‘ ืฉืžืชืฉืž ืšื ื™ื ืื .ื”ื ื™ืžื– ืชื™ืชืฉืชื” ืื TLS -ื‘ ืฉืžืชืฉื” ,ืชื•ื ืคืฆื•ืžื• ืชื•ื—ื˜ื‘ื•ืืž ืชื•ื™ืฆืงื–ื ืจื˜ ืจื•ื‘ืข . ื™ืœื ื•ื™ืฆืคื•ื ืื•ื” TLS -ื” .Secret
ื™ื˜ื™ืจืค ืชื ืงืคืกืžื• ื”ืžืกื™ืกื”ื• ืฉืžืชืฉืžื” ืืฉ ืชื•ืขืฆืžืื‘ Intel AMT -ื” ื‘ืฉื—ืžืœ ื”ืกื™ื ื› ืขืฆื‘ืž SCS -ื” .TLS ื•ืžื› ื—ื˜ื‘ื•ืืž ื•ื ื™ื HTTP Digest .ื™ื“ื“ื” ืชื•ืžื™ื ืชืจื˜ืžืœ Digest
:ืื™ืื‘ื” ืื™ืฉื•ืจื“ื” ืื™ื ื•ืชื ื”
(ืื™ื™ื“ื™ืชืข ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืจื•ื‘ืข) ืื™ืฉื“ื— PID - ื• PPS
TLS ื™ืจื•ืฉื™ื
ืื™ื™ื˜ืจืค ืชื•ื—ืชืคืž
ืื™ื™ื—ื›ื•ื  ื”ืขืฉื• ืšื™ืจืืช
HTTP Digest ื™ืจื•ืฉื™ื
HTTP Negotiate ื™ืจื•ืฉื™ื
.ื‘ืฉื—ืžื” ืชื ืงื•ื—ืจืž ืœื”ื ืœ ืŸืชื™ื  ,ื”ืงืคืกื ื‘ืฆืžื‘ .ืืœืž ืŸืคื•ืื‘ ื“ืงืคืชืž Intel AMT ืŸื›ืž ืจื—ืืœื• ื”ืงืคืกืื” ื‘ืฆืžืœ ื”ืจื“ื’ื”ื” ื‘ืฆืžืž ืจื‘ื•ืข ื‘ืฉื—ืžื”
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 98
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
ื”ืœืขืคื”ื” ืชื›ืจืขืž ืœืฉ ืื™ื ืงืชื” ื™ืœื”ื ืž
ืชื•ืืกืจื’ื‘ ื•ืžื› ืืœืฉ .ืŸืœื”ืœ ื”ื ื•ื“ื  ืŸืงืชื”ื” ืœื”ื ืž ืชืœื•ืขืค .ืื™ื ืงืชื”ื” ืœื”ื ืžื‘ ืื™ืจื›ื•ืž ืืœ ืื™ื ืงืชื” ืจื™ืกื”ืœ ื™ื“ื› ืŸืงืชื•ืž ืชื•ื™ื”ืœ ื‘ื™ื™ื— AMT Unified -ื” ืœืฉ ืŸืงืชื”ื” ืœื”ื ืž ,ื”ืœืขืคื”ื” ืชื›ืจืขืž ืšื•ืชื‘
ื™ืœื”ื ืž ื™ื ืฉ ืชื ืชืงืคืกืž ืชื™ื—ื›ื•ื ื” ื”ืกืจื’ื” ,ื—ื•ืงืœื” ืœืฉ ืฉื“ื—ืž ื”ื ืงืชื” ืœืฉ ื˜ื‘ืž ืชื“ื•ืงื ืž ,LMS/SOL -ื• HECI ,ืื™ื“ืจืคื  ืื™ื ืงืชื” ื™ืœื”ื ืž ื™ื ืฉ ื•ื™ื” ืŸื”ื‘ืฉ (5 ื•ื ,4 ,3) ืชื•ืžื“ื•ืง
.ืื™ื ืงืชื”ื” ืœื”ื ืžื‘ PCI -ื” ื™ื ืงืชื” ื™ื ืฉ ืชื ืชืœื”ื ืž ืื™ื” ,ืชื ืงืชื•ืž ืชื“ื—ื•ืืžื” ืื™ื ืงืชื”ื” ื™ืœื”ื ืž ืชืœื™ื‘ื— ืจืฉืื› .AMT Unified Driver ืชืืจืงื ืฉ ืชืคืชื•ืฉืž ื”ืœื™ื‘ื—ื‘ ืื™ื ืงืชื”ื”
AMT Unified Driver
ืจื•ื˜ื™ืœืงืชื‘ื• support.dell.com ืจืชืื‘ ืŸื™ืžื– (Intelยฎ AMT Serial-Over-LAN (SOL) / Local Manageability Service (LMS ืŸืงืชื”ื” ืœื”ื ืž
.ืฅื‘ื•ืงื” ืชื ืœืขืคื” , ืŸืงืชื”ื” ืœื”ื ืž ืชื’ืฉื” ืจื—ืืœ .Intel AMT SOL/LMS ืŸืžื•ืกืž ืŸืงืชื”ื” ืœื”ื ืž .(ืื™ื‘ื‘ืฉ ืชื›ืจืข ืœืฉ ืื™ื ืงืชื” ื™ืœื”ื ืž) Chipset Drivers ืชื—ืช ResourceCD
.ื”ื ืงืชื”ื” ืšื™ืœื”ืช ืšืฉืžื” ืชื ืจืฉืืœ ืฉืงื‘ืชืž ืฉืžืชืฉืžื”ื• ืกืจืคื  ืฅื‘ื•ืงื”
Intel Active Management Technology - SOL ืšืจืขืœ ืšืคื•ื” (PCI ืชื™ืจื•ื˜ ื”ืื™ืฆื™) PCI Serial Port ืšืจืขื” ,SOL/LMS ืŸืงืชื”ื” ืœื”ื ืž ืชื ืงืชื” ืจื—ืืœ
.((COM3
HECI ืŸืงืชื” ืœื”ื ืž
Chipset ืชื—ืช ResourceCD ืจื•ื˜ื™ืœืงืชื‘ื• support.dell.com ืจืชืื‘ ืŸื™ืžื– (Intel AMT Host Embedded Controller Interface (HECI ืŸืงืชื”ื” ืœื”ื ืž
ืชื ืจืฉืืœ ืฉืงื‘ืชืž ืฉืžืชืฉืžื”ื• ืกืจืคื  ืฅื‘ื•ืงื” .ืฅื‘ื•ืงื” ืชื ืœืขืคื” ,ืŸืงืชื”ื” ืœื”ื ืž ืชื’ืฉื” ืจื—ืืœ .Intel AMT HECI ืŸืžื•ืกืž ืŸืงืชื”ื” ืœื”ื ืž .(ืื™ื‘ื‘ืฉ ืชื›ืจืข ืœืฉ ืื™ื ืงืชื” ื™ืœื”ื ืž) Drivers
.ื”ื ืงืชื”ื” ืšื™ืœื”ืช ืšืฉืžื”
.Intel Management Engine Interface ืšืจืขืœ ืšืคื•ื” PCI Simple Communications Controller ืšืจืขื” ,HECI ืื™ื ืงืชื”ื” ื™ืœื”ื ืž ืชื ืงืชื” ืจื—ืืœ
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Page 99
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Intel AMT WebGUI
ืชืขื™ื‘ืงื• ื”ืจื“ื’ื”ื” ืื ืขื•ื‘ืงืœ ืชื ืž ืœืข ื”ืงื™ื“ื‘ื› ืฉืžืฉืž WebGUI -ื” ืชื•ื‘ื•ืจืง ืื™ืชืขืœ .ืœื‘ื’ื•ืž ืŸืคื•ืื‘ ืงื•ื—ืจืž ื‘ืฉื—ืž ืœื•ื”ื™ื ืœ ื˜ื ืจื˜ื ื™ื ืŸืคื“ืคื“ ืกืกื•ื‘ืž ืงืฉืžืž ืื•ื” Intelยฎ AMT WebGUI
Intel ืœืฉ ื”ื›ืœื”ื› ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืŸื™ื™ืฆืž WebGUI ื•ื‘ ืœืขื•ืคืฉ ื—ืจืืžื” ื‘ืฉื—ืžื” ืŸื™ื‘ืœ ืงื—ื•ืจืž ื‘ืฉื—ืž ืŸื™ื‘ ืงื•ื—ืจืž ื—ืœืฆื•ืž ืจื•ื‘ื™ื— .ื‘ืฉื—ืžื‘ ื”ื›ืœื”ื› ื•ืขืฆื•ื‘ Intel AMT ืœืฉ ื”ืจื•ืฆืชื”
.ืงื—ื•ืจืžื” ื‘ืฉื—ืžื‘ AMT
ยฎ
.
Internet Explorer ืŸื•ื’ื› , ื˜ื ืจื˜ื ื™ื ืŸืคื“ืคื“ ืœื›ืž ืฉื™ื’ื  Intel AMT WebGUI
:ืœืœื•ื› ืœื‘ื’ื•ืž ืŸืคื•ืื‘ ืงื•ื—ืจืž ื‘ืฉื—ืž ืœื•ื”ื™ื 
ื”ืจืžื•ื— ื™ืืฆืž
ืื™ืขื•ืจื™ื ืŸืžื•ื™ื‘ ืื•ืฉื™ืจ
ืงื•ื—ืจืž ื‘ืฉื—ืž ืกื•ืคื™ื
ืชืฉืจ ืชื•ืจื“ื’ื” ื™ื•ื ื™ืฉ
ืื™ืฉื“ื— ืื™ืฉืžืชืฉืž ืชืคืกื•ื”
.Intel AMT ืœืฉ ื˜ื ืจื˜ื ื™ืื” ืจืชื ื‘ ืŸื™ืžื– WebUI ืงืฉืžืžื‘ ืฉื•ืžื™ืฉื” ืชื•ื“ื•ื ืขื“ื™ืž :ื”ืจืขื”
.ื”ืขื‘ืงื  ื•ืชืจื•ืฆืชื• ืจื“ื’ื•ื”ืฉ ื‘ืฉื—ืžื‘ Intel AMT WebUI -ืœ ืจื‘ื—ืชื”ืœ ื™ื“ื› ืŸืœื”ืœ ืื™ื‘ืœืฉื” ืชื ืขืฆื‘
Intel AMT WebUI
.Intel AMT ืœืฉ ื”ืจื•ืฆืช ืชืขื™ื‘ืงื• ื”ืจื“ื’ื” ืื™ืœืฉื”ืฉ Intel AMT ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืžื” ืชื ืœืขืคื”
.Intel AMT -ื” ื‘ืฉื—ืž ืœืฉ ื”ื ืฉืž ืชืฉืจ ื”ืชื•ืื‘ ืœื•ื”ื™ื  ื‘ืฉื—ืž ืŸื•ื’ื› , ื“ืจืคื  ื‘ืฉื—ืžื‘ ื˜ื ืจื˜ื ื™ื ืŸืคื“ืคื“ ืœืขืคื”
ื•ื http://ip_address:16992 :ื”ืžื’ื•ื“) .Intel AMT ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืžื” ืœืฉ ื”ืื™ืฆื™ืœื• MEBx -ื‘ ืชื ื™ื•ืฆืžื” IP -ื” ืชื‘ื•ืชื›ืœ ืจื‘ื—ืชื”
(http://192.168.2.1:16992
.16992 ืื™ื” ื”ืื™ืฆื™ื” ,ืœื“ื—ืž ืชืจื™ืจื‘ื›
.ื™ื ื•ื’ืจื ื‘ืฆืžืœ ื”ืขื‘ืงื  ื•ืชืจื•ืฆืชื• ืจื“ื’ื•ื”ืฉ ื‘ืฉื—ืžื‘ Intel AMT WebUI -ืœ ืจื‘ื—ืชื”ืœ ื™ื“ื› //:htts -ื‘ื• 16993 ื”ืื™ืฆื™ื‘ ืฉืžืชืฉื” :ื”ืจืขื”
:ื”ืžื’ื•ื“) .ืื•ื—ืชื”ื• ื—ืจืืžื” ืืฉ ืœืฉ ื‘ื•ืœื™ืฉื” ืื•ื” FQDN -ื” .ME -ื” ืจื•ื‘ืข (FQDN) ืืœืž ืื•ื—ืช ืืฉื‘ ืฉืžืชืฉื” ,DHCP -ื‘ ืฉื•ืžื™ืฉ ื”ืฉืขื  ืื
(http://system1:16992 ื•ื http://host_name:16992
Management -ื” ืšื•ืชื‘ Intel AMT -ื‘ ืขื‘ื˜ื•ืžื” ืจืชื•ื™ื‘ ื”ื”ื•ื‘ื’ื” ื”ืžืจื‘ ื˜ื ืจื˜ื ื™ืื” ืฃื“ืœ ืฉื’ื™ื ื• Intel AMT -ื” ืจืฉืคื•ืืž ื‘ืฉื—ืžืœ TCP ืจื•ื‘ื™ื— ืจืฆื•ื™ ืœื•ื”ื™ื ื” ื‘ืฉื—ืž
.Intel AMT ืชืœื•ื›ื™ ืืข ื‘ืฉื—ืžื” ืœืฉ Engine
.MEBx -ื‘ Intel AMT ืชืจื“ื’ื” ืšืœื”ืžื‘ ืจื“ื’ื•ื”ืฉ ืšืจืขื” ืื™ื” ื”ืžืกื™ืกื”ื• admin ืื•ื” ืœื“ื—ืžื” ืชืจื™ืจื‘ ืฉืžืชืฉืž ืืฉ .ื”ืžืกื™ืกื”ื• ืฉืžืชืฉืžื” ืืฉ ืชื ื“ืœืงื”
.ืื™ืฉื•ืจื“ ืื™ื™ื•ื ื™ืฉ ืขืฆื‘ื• ื‘ืฉื—ืžื” ืขื“ื™ืžื‘ ืŸื™ื™ืข
ื”ืžืกื™ืกื” .ืชื•ืืžืกื™ืก ื™ืชืฉ ืจืฆื•ื™ ืงื—ื•ืจืž ืฃื•ืกืžื‘ ื•ื WebUI -ื‘ ื”ืžืกื™ืกื” ื™ื•ื ื™ืฉ .WebUI -ื‘ ืงื—ื•ืจืžื” ื‘ืฉื—ืžื” ืจื•ื‘ืข MEBx ืชืžืกื™ืก ืชื ืชื•ื ืฉืœ ืšืชื•ืจืฉืคืื‘ :ื”ืจืขื”
ืœื ืชื™ืžื•ืงืž ื”ืฉื™ื’ืœ ืชืฉืžืฉืžื” ืชื™ืžื•ืงืžื” MEBx ืชืžืกื™ืก .ืงื—ื•ืจืžื” ืฃื•ืกืžื” ื•ื WebUI -ื” ืชื•ืขืฆืžืื‘ ืงื•ื—ืจืž ืงืจ ืชืœืขื•ืค ,ืชืงื—ื•ืจืž MEBx ืชืžืกื™ืกื› ื”ืขื•ื“ื™ื” ,ื”ืฉื“ื—ื”
.ืงื•ื—ืจืžื• ื™ืžื•ืงืž ืŸืคื•ืื‘ MEBx -ื” ื‘ืฉื—ืžืœ ืชืฉื’ืœ ื™ื“ื› MEBx -ื” ืœืฉ ืชืงื—ื•ืจืžื” ื”ืžืกื™ืกื” ืชื ืŸื”ื• ืชื™ืžื•ืงืžื” ื”ืžืกื™ืกื” ืชื ืŸื” ืจื•ื›ื–ืœ ืšื™ืœืข .ื”ื ืชืฉืž ื”ื ื™ื MEBx -ื”
ืŸื ื™ื ืชื•ืืžืกื™ืกื” , ืชืคืœื—ื•ืž ืชืงื—ื•ืจืžื” ื”ืžืกื™ืกื” ืื .ื“ื—ื™ ืื’ ืชืงื—ื•ืจืžื• ืชื™ืžื•ืงืž ื”ืžืกื™ืกื› ืชืฉืžืฉืž ื”ืžืกื™ืกื” ,Intel AMT ืชืจื“ื’ื”ื‘ ื”ืœื™ื—ืชื‘ ืชืจื“ื’ื•ืž MEBx ืชืžืกื™ืก ืจืฉืื›
.ืชื•ื ืจื›ื ื•ืกืž
.(ื”ืื™ืฆื™) Exit ืจื—ื‘
ืŸื›ื•ืชื”
ืฃื“ืœ ื”ืจื–ื—
Page 100
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
AMT Redirection ืชืจื™ืงืก
-ื” ืชืœื•ื›ื™ืœ ืงืจ ืงื•ืงื– ื—ื•ืงืœื” .ืœื”ื•ื ืžื” ื—ื•ืงืœื” ืœืฉ ืœืžืฉื—ื” ืชืงืคืกืื• ืœื•ื—ืชืื” ื‘ืฆืžื‘ ืชื•ืœืช ืืœืœ ,ืœื”ื•ื ืž ืฃื•ืกืžืœ ืœื”ื•ื ืž ื—ื•ืงืœืž IDE -ื• ืชื™ืจื•ื˜ ืชืจื•ืฉืงืช ืฉื“ื—ืž ื‘ืชื ืœ ืจืฉืคืืž Intelยฎ AMT
,IDE Redirection (IDER - ื‘ื• (ืื™ืฉืงืž ื—ื•ืœ/ื˜ืกืงื˜ ืœืฉ ืฉื“ื—ืž ื‘ื•ืชื™ื  ,Serial Over LAN (SOL -ื‘ ืšืžื•ืช Intel AMT .ืชืฉืจ ืจื•ื‘ื™ื—ื• ืœืžืฉื— ืจื•ืงืžืœ ืจื•ื‘ื™ื— ,Intel AMT
.TCP/IP ื™ื ืค ืœืข (ืื™ืจื•ื˜ื™ืœืงืช ืŸื ื•ื› ืœืฉ ืฉื“ื—ืž ื‘ื•ืชื™ื 
Serial Over LAN ืชืจื™ืงืก
,ืœื•ื”ื™ื ื” ื™ืžื•ืฉื™ื™ ื‘ื•ืจ ืจื•ื‘ืข SOL -ื‘ ืฉืžืชืฉื”ืœ ืŸืชื™ื  .ืœื™ื’ืจ ืชืฉืจ ืจื•ื‘ื™ื— ื™ื ืค ืœืข ืชื™ืจื•ื˜ ื”ืื™ืฆื™ ืชืจื•ืฉืงืช ืชื•ืžื“ืœ ืชืœื•ื›ื™ื” ืื•ื” (SOL - ืชื™ืžื•ืงืž ืชืฉืจ ื™ื ืค ืœืข ื™ืจื•ื˜) Serial Over LAN
.ืชื™ืžื•ืงืž ืชื™ืจื•ื˜ ื”ืื™ืฆื™ ืจื•ื‘ื™ื— ืฉืจื“ื  ืœืœื› ืšืจื“ื‘ ืื”ื‘ืฉ
ืฉื“ื—ืž ืชื‘ืชื•ื ืž ื—ื•ืงืœื” ืœืฉ ืชื™ืจื•ื˜ื” ื”ืจื•ื‘ืขืชื” ,Intel AMT ืœืฉ ืฉื“ื—ืž ื‘ื•ืชื™ื ื” ืชื™ื™ืจืคืก ืชื•ืขืฆืžืื‘ , ืœื•ื”ื™ื  ืฃื•ืกืž ืŸื™ื‘ืœ Intel AMT ืจืฉืคื•ืืž ื—ื•ืงืœ ืŸื™ื‘ ืชืจืฆื•ื  ื”ืœื™ืขืค SOL ืชื•ืœื™ืขืค ืจืฉืื›
ื”ืื™ืฆื™ื” ืšืจื“ ื•ืขื™ื’ื” ื•ืœื™ืื› ื”ืืจื ืฉ ,LAN -ื” ืจื•ื‘ื™ื— ืšืจื“ ืื™ื™ืจื•ื˜ ืื™ื ื•ืชื  ื—ื•ืœืฉืœ ืœื•ื›ื™ ืœื•ื”ื™ื ื” ืฃื•ืกืž ,ื”ืžื•ื“ื‘ . ืœื•ื”ื™ื ื” ืฃื•ืกืžืœ ื”ื ื™ืžื– ืชื™ืฉืขื ื• LAN -ื” ืจื•ื‘ื™ื— ื™ื ืค ืœืข Intel AMT ืšืจื“
.ื—ื•ืงืœื” ืœืฉ ืชื™ืจื•ื˜ื”
IDE Redirection ืชืจื™ืงืก
IDER .ืœื™ื’ืจ ืชืฉืจ ืจื•ื‘ื™ื— ืšืจื“ IDE ื’ื•ืกืž LS-120 ืŸื ื•ื› ื•ื ืื“ื•ืง ืจื•ื“ืž ืื™ื ื•ื˜ื™ืœืงืช ืŸื ื•ื› , ืื™ืจื•ื˜ื™ืœืงืช ืŸื ื•ื› ืชื•ืžื“ืœ ืœื’ื•ืกืž (IDE - IDER ืœืฉ ืฉื“ื—ืž ื‘ื•ืชื™ื ) IDE Redirection
ืจื‘ื•ื—ืž ื”ื™ื” ื•ืœื™ืื› ืงื—ื•ืจืžื” ืŸืงืชื”ื‘ ืฉืžืชืฉื”ืœ ืœื•ื›ื™ ืœื”ื•ื ืžื” ื—ื•ืงืœื” ,IDER ืชื•ืœื™ืขืค ืชืจืฆื•ื ืฉ ืขื’ืจื‘ . ืชืฉืจื” ืšืจื“ ืœื”ื•ื ืž ื—ื•ืงืœืœ ื•ืœืฉ ืื™ื™ืžื•ืงืžื” ืื™ื ื ื•ื›ื”ืž ื“ื—ื ืจื‘ื—ืœ ืœื•ื”ื™ื  ื‘ืฉื—ืžืœ ืจืฉืคืืž
.DVD ืชื™ื ื‘ืชื‘ ืšื•ืžืช ื•ื ื™ื IDER . ื‘ื™ื’ืž ื•ื ื™ืืฉ ื‘ืฉื—ืž ืœืฉ ืงื•ื—ืจืž ืœื•ื—ืชืืœ ื™ืฉื•ืžื™ืฉ ืชื•ื™ื”ืœ ืœื•ื›ื™ ื”ื– ืจื‘ื“ .ื•ืžืฆืข ื•ืœืฉ IDE - ื” ื™ืฆื•ืจืขืž ื“ื—ืืœ ืชื•ืจื™ืฉื™
ืฃื•ืกืž ืจืฉืื› ,ื˜ื ืžื•ื’ืจืื› ืจื‘ืขื•ืž ื”ื– ืŸื ื•ื› , ืŸื›ืž ืจื—ืืœ .ืœื•ื”ื™ื ื” ืฃื•ืกืž ืœืฉ ืงืกื™ื“ื” ืŸื ื•ื›ื‘ ืŸืขื˜ื  ื™ืงื•ื— ืœื•ื—ืชื ืงืกื™ื“ ,ื”ืœื™ื—ืช . ื”ืžื•ื’ืค ื”ืœืขืคื” ืชื›ืจืขืž ืืข ื—ื•ืงืœ ืœื•ื—ืชืืœ ืฉืžืฉืž IDER ,ื”ืžื’ื•ื“ืœ
SOL - ื‘ ืฉืžืชืฉื”ืœ ืŸืชื™ื  .ื•ืœืฉ ืœื•ื—ืชืื” ื‘ืฆืžื‘ ื•ื ืœืขืคื•ืž ืื•ื” ืื ืชื•ืœืช ืืœืœ ,ื—ื•ืงืœื‘ ื™ืœืื•ื˜ืจื™ื• IDE ืŸืงืชื”ื› ืŸืงืชื”ื” ืชื ืืฉื•ืจ IDER TCP. Intel AMT -ื” ืชื•ืœื™ืขืค ืชื ื—ืชื•ืค ืœื•ื”ื™ื ื”
.ื™ืœืื•ื˜ืจื™ื•ื•ื” IDE -ื” ืŸืงืชื”ืž ืœื•ื—ืชืืœ ื—ื•ืงืœื” ืœืฉ BIOS - ื” ืชืจื•ืฆืช ืชื ืขื•ื‘ืงืœ ืšืจื•ืฆ ื”ื™ื”ื™ืฉ ืŸื›ืชื™ื™ืฉ ืŸื•ื•ื™ื›ืž ,ื“ื—ื™ IDER -ื‘ื•
ืŸื›ื•ืชื” ืฃื“ืœ ื”ืจื–ื—
Loading...