Dell Networking N2000 Series
Switch Configuration Guide for EqualLogic SANs
Dell Storage Engineering
May 2014

Revisions
© 2014 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express
written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.
Dell, the Dell logo, and the Dell badge, EqualLogic, and Force10 are trademarks of Dell Inc.
2 SCG1015 Dell Networking N2000 Series Configuration Guide

Table of contents
Revisions ............................................................................................................................................................................................. 2
1 Introduction ................................................................................................................................................................................ 4
1.1 Audience ........................................................................................................................................................................... 4
1.2 Switch details ................................................................................................................................................................... 4
1.3 Cabling diagram .............................................................................................................................................................. 5
2 Dell recommended switch configuration ............................................................................................................................. 6
2.1 Hardware configuration ................................................................................................................................................. 6
2.2 Delete startup configuration ......................................................................................................................................... 6
2.3 Configure out-of-band management port (Optional) ............................................................................................. 8
2.4 HTTP and Telnet authentication .................................................................................................................................. 8
2.5 Enable iSCSI optimization feature ................................................................................................................................ 9
2.6 Enable flow control ........................................................................................................................................................ 9
2.7 Configure Jumbo MTU for all ports .......................................................................................................................... 10
2.8 Configure spanning tree portfast on edge ports..................................................................................................... 10
2.9 Configure 10GbE ports for LAG ................................................................................................................................. 10
2.10 Save configuration ........................................................................................................................................................ 10
2.11 Configure additional switch ......................................................................................................................................... 11
3 Stack configuration (optional) ............................................................................................................................................... 12
3.1 Configure out-of-band management port (Optional) ........................................................................................... 14
3.2 HTTP and Telnet authentication ................................................................................................................................ 14
3.3 Enable iSCSI optimization feature .............................................................................................................................. 15
3.4 Enable flow control ...................................................................................................................................................... 15
3.5 Configure Jumbo MTU for all ports .......................................................................................................................... 16
3.6 Configure spanning tree portfast on edge ports..................................................................................................... 16
3.7 Save configuration ........................................................................................................................................................ 16
Additional resources ....................................................................................................................................................................... 17
3 SCG1015 Dell Networking N2000 Series Configuration Guide

Dell Networking N2000 Series
Dell Networking N2000 series – N2024, N2048
1 Introduction
This document illustrates how to configure Dell™ Networking N2000 Series switches for use with
EqualLogic™ PS Series storage using Dell best practices. The recommended configuration uses link
aggregation groups (LAGs) for inter-switch connections.
If you are following the Rapid EqualLogic Configuration steps at
http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portalby-sis.aspx, use sections 1 and 2 from this guide for LAG, or sections 1 and 3 from this guide for stack
configuration.
For more information on EqualLogic SAN design recommendations, see the EqualLogic Configuration
Guide at: http://en.community.dell.com/dell-
groups/dtcmedia/m/mediagallery/19852516/download.aspx.
1.1 Audience
This switch configuration guide describes an optimal configuration following Dell best practices for an
EqualLogic iSCSI SAN and is intended for storage or network administrators and deployment personnel.
1.2 Switch details
The table below provides an overview of the switch configuration.
Table 1 Switch specifications
Note: For proper functionality, the switch must be at the switch firmware version shown in the table
above before proceeding with this configuration. Using previous firmware versions may have
unpredictable results.
The latest firmware updates and documentation can be found at: support.dell.com.
4 SCG1015 Dell Networking N2000 Series Configuration Guide

1.3 Cabling diagram
The cabling diagram shown below represents the Dell recommend method for deploying your servers and
EqualLogic arrays.
Figure 1 Cabling diagram
5 SCG1015 Dell Networking N2000 Series Configuration Guide

2 Dell recommended switch configuration
These steps show you how to configure two Dell Networking N2000 switches with a Link Aggregation
Group (LAG). The switches are interconnected using the fixed 10GbE SFP+ module on the front and the
LAG is configured for Dynamic Link Aggregation Control Protocol (LACP).
2.1 Hardware configuration
1. Power on the two switches.
2. Connect a serial cable to the serial port of the first switch.
3. Using any terminal utility, open a serial connection session to the switch.
4. Open your terminal emulator and configure it to use the serial port (usually COM1, but this may
vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow
control.
5. Connect the optical cables between the fixed 10GbE module on the front of the N2000 switches.
See this configuration in Figure 1.
2.2 Delete startup configuration
Note: All configuration settings will be deleted
console>enable
console#reload
Are you sure you want to reload the stack? (y/n) y
Note: The switch will reboot.
Follow the prompts shown below when the Main Menu is displayed during the bootup process.
Dell Networking Boot Options
============================
Select a menu option within 3 seconds or the Operational Code will start
automatically...
1 - Start Operational Code
2 - Display Boot Menu
Select (1, 2)# 2
Boot Main Menu
==============
6 SCG1015 Dell Networking N2000 Series Configuration Guide