Dell Metered PDU LED Specifications

English Dell™ Metered Rack

Power Distribution Unit (PDU)
G728N
Product Overview and Specifications
English Français Español
日本語版
Product Overview and Specifications
OUTLETS— The Rack PDU has twenty (20) 5-15 R outlets.
OWER CORD— The Rack PDU has an IEC-320-C20 inlet and can be used with a detachable power cord (not provided).
P
G728N
Electrical
Input connection IEC-320-C20 Acceptable input voltage 100–120 VAC Maximum input current (phase) 16 A Input frequency 50/60 Hz Input power 1.9 kVA UL and C-UL (derated), PSE Output voltage 100–120 VAC (Line-to-Neutral) Output connections Twenty (20) 5-15 R Maximum output current (outlet) 5-15 R: 12 A UL and C-UL (derated), PSE Maximum output current (phase) 16 A UL and C-UL (derated), PSE
Physical
± 10%
Dimensions (H x W x D)
Shipping dimensions (H x W x D)
Weight 4.1 kg (9.0 lb) Shipping weight 5.9 kg (13.0 lb)
162.5 x 5.5 x 4.1 cm (64.0 x 2.2 x 1.6 in)
187.5 x 22.6 x 13.5 cm (73.8 x 8.9 x 5.3 in)
Environmental
Maximum elevation (above MSL)
Operating Storage
Temperature
Operating Storage
Humidity
Operating Storage
0 to 3048 m (0 to 10,000 ft) 0 to 15 240 m (0 to 50,000 ft)
0 to 50°C (32 to 122°F) –15 to 60°C (5 to 140°F)
5 to 95%, non-condensing 5 to 95%, non-condensing
2 Dell Metered Rack Power Distribution Unit—Product Overview and Specifications
Compliance
Safety UL, C-UL, PSE EMC FCC Part 15 Class A, ICES-003 Class A, VCCI-A, EN
55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, AS/NZS CISPR 22 Class A, EU EMC DIRECTIVE 2004/108/EC–latest revision
Environmental Dell 6T198
EU RoHS DIRECTIVE 2002/95/EC–latest revision
Dell Metered Rack Power Distribution Unit—Product Overview and Specifications 3
Information in this document is subject to change without notice.
www.dell.com | support.dell.com
© 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, and the DELL logo are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell
Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Model G728N
03/2010 Part Number 990-4207

Français

Unité de distribution de l'alimentation (PDU) Dell™
à monter en rack avec compteur
Présentation et caractéristiques techniques du produit