Delfield F18DC52-E Installation Manual

F18 Series
Work Tables
Original Instructions Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 9291454 09/15
F18 Series Service and Installation Manual
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other
Appliance.
WARNING Do Not Store Explosive Substances Such As Aerosol Cans With A Flammable Propellant In This Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment.
WARNING This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have
Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety.
WARNING This Appliance Is Not To Be Played With.
WARNING Do Not Clean With Water Jet.
WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance.
CAUTION Observe the following:
Minimum clearances must be maintained from all walls and combustible materials.
Keep the equipment area free and clear of combustible material.
Allow adequate clearance for air openings.
Operate equipment only on the type of electricity indicated on the specification plate.
Unplug the unit before making any repairs.
Retain this manual for future reference.
NOTES
All models intended for sale and use in Australia and New Zealand use only R-404A as a refrigerant. No flammable refrigerants are used.
All models intended for sale and use in Australia and New Zealand are of climatic class 4 (30°C, 55%RH).
All models intended for sale and use in Australia and New Zealand use ecomate® as the insulation blowing gas which is nonflammable.
2
Contents
Receiving & Inspecting .........................................................3
Serial Number Location ........................................................4
Warranty Information ............................................................4
Regulatory Certifications .......................................................4
Domestic Specifications .................................................... 5-7
Export Specifications ........................................................ 8-9
Installation ..........................................................................10
Operation ...................................................................... 11-12
Temperature Settings ..........................................................13
Maintenance .................................................................. 14-15
F18 Series Service and Installation Manual
Receiving and Inspecting the Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
4. Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs or casters are not bent.
6. Also open the compressor compartment housing and
7. Freight carriers can supply the necessary forms upon
8. Retain all crating material until an inspection has been
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.
visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
request.
made or waived.
3
F18 Series Service and Installation Manual
Serial Number Location
The serial number on all self-contained F18 Series refrigerated work tables and freezer bases is located on the electrical specifications tag affixed inside the compressor section next to the pressure control.
On remote refrigerated bases with doors, the tag is inside the unit on the coil side. On remote refrigerated bases with drawers, the tag is affixed to the drawer divider. On remote freezer bases, the tag is located on the inside back of the unit.
Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is available at www.delfield.com.
©2015 The Deleld Company. All rights reserved. Reproduction without written permission is prohibited. “Deleld” is a registered trademark of The Deleld Company.
Warranty Information
Visit http://www.delfield.com/minisite/service/warranty_info to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
Domestic Models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL) Underwriters Laboratories of Canada (CUL)
Export (-E) (230-240V/50Hz/1Ph) Models are certified by:
National Sanitation Foundation (NSF)
Technical Inspection Association
European Conformity
4
F18 Series Service and Installation Manual
Domestic Specifications
Remote Refrigerated Work Tables
Model # Of Doors
F18WR31 (1) 19” 70 7.56 2.56 115/60/1 3.0 383 120/3°
F18WR39 (1) 27” 124 10.23 3.95 115/60/1 3.0 465 120/4°
F18WR44 (2) 19” 70 12.14 5.12 115/60/1 3.0 605 120/5°
F18WR52 (1) 19” & (1) 27” 70/124 15.12 6.51 115/60/1 3.0 686 120/6°
F18WR60 (2) 27” 124 18.10 7.90 115/60/1 3.0 768 120/6°
F18WR70 (2) 32” 140 21.23 9.64 115/60/1 3.0 869 120/7°
F18WR79 (2) 27” & (1) 19” 124/70 24.48 10.29 115/60/1 6.0 1050 240/4°
F18WR87 (3) 27” 124 27.46 11.85 115/60/1 6.0 1131 240/5°
Shelf Max Load (lbs)
Self-Contained Refrigerated Work Tables
Model # Of Doors
F18WC39 (1) 19” 70 7.56 2.56 115/60/1 8.0 383 1462 16 1/5 5-15P
F18WC47 (1) 27” 124 10.23 3.95 115/60/1 8.0 465 1462 16 1/5 5-15P
F18WC52 (2) 19” 70 12.14 5.12 115/60/1 8.0 605 1462 16 1/5 5-15P
F18WC60 (1) 19” & (1) 27” 70/124 15.12 6.51 115/60/1 8.0 686 1462 16 1/5 5-15P
F18WC68 (2) 27” 124 18.10 7.90 115/60/1 8.0 768 1462 16 1/5 5-15P
F18WC78 (2) 32” 140 21.23 9.64 115/60/1 10.0 869 1994 16 1/4 5-15P
F18WC87 (2) 27” & (1) 19” 124/70 24.48 10.29 115/60/1 10.0 1050 2261 16 1/4 5-15P
F18WC95 (3) 27” 124 27.46 11.85 115/60/1 10.0 1131 2261 16 1/4 5-15P
Shelf Max Load (lbs)
Base Volume
3
FT
Base Volume
3
FT
Shelf
Area FT
Shelf
Area FT
Volts/Hertz/
2
Phase Amps BTU Load EVAP. BTU/°TD
Volts/Hertz/
2
Phase Amps BTU Load BTU System Cap.
R-404A
oz. H.P.
NEMA
Plug
Remote Refrigerated Mega Top Tables
Model # Of Doors
F18MR31A (1) 19” 70 4.14 6 115/60/1 3.0 280/265 120/2°/12/22°
F18MR44A (2) 19” 70 7.15 6 115/60/1 3.0 444/265 120/4°/12/22°
F18MR44D (2) 19” 70 7.15 12 115/60/1 3.0 444/529 120/4°/22/25°
F18MR52A (1) 19” & (1) 27” 70/124 8.97 6 115/60/1 3.0 515/265 120/4°/12/22°
F18MR52D (1) 19” & (1) 27” 70/124 8.97 12 115/60/1 3.0 515/529 120/4°/22/25°
F18MR52E (1) 19” & (1) 27” 70/124 8.97 18 115/60/1 3.0 515/794 120/4°/31/26°
Shelf Max Load (lbs)
Base Volume
3
FT
# of Pans
Volts/Hertz/
Phase Amps
BTU Load Base/Rail
EVAP. BTU/°TD
Base/Rail
Self-Contained Refrigerated Mega Top Tables
Model # Of Doors
F18MC39A (1) 19” 70 4.14 6 115/60/1 7.0 280/265 1903/925 16 1/4 5-15P
F18MC39D (1) 19” 70 4.14 12 115/60/1 7.0 280/529 1903/1156 16 1/4 5-15P
F18MC52A (2) 19” 70 7.15 6 115/60/1 7.0 444/265 1903/925 16 1/4 5-15P
F18MC52D (2) 19” 70 7.15 12 115/60/1 7.0 444/529 1903/1156 16 1/4 5-15P
F18MC52E (2) 19” 70 7.15 18 115/60/1 7.0 444/794 1903/1321 16 1/4 5-15P
F18MC60A (1) 19” & (1) 27” 70/124 8.97 6 115/60/1 7.0 515/265 2314/864 16 1/4 5-15P
F18MC60D (1) 19” & (1) 27” 70/124 8.97 12 115/60/1 7.0 515/529 2314/1141 16 1/4 5-15P
F18MC60E (1) 19” & (1) 27” 70/124 8.97 18 115/60/1 7.0 515/794 2314/1361 16 1/4 5-15P
F18MC60F (1) 19” & (1) 27” 70/124 8.97 24 115/60/1
Shelf Max Load (lbs)
Base Volume
3
FT
# of Pans
Volts/Hertz/
Phase Amps
BTU Load Base/Rail
7.0 515/1058 2314/1540 16 1/4 5-15P
BTU System Cap.
Base/Rail
R-404A
oz. H.P.
NEMA
Plug
5