dbx 480P User Guide

User Manual
Complete Equalization & Loudspeaker Management System
480P
Power Supply
®
480P Rear Panel
IEC Power Cord Receptacle
The 480P comes with a IEC power supply cord and a selectable power supply.
Voltage Selector Switch
The 480P allows you to select either 115V with 500mA 250V SLOW BLOW fuse or 230V with 250mA 250V Type “T” fuse. WARNING: Fuse must be changed to correspond with the desired power setting.
RS485 Link to 480R (DB-9 connector type)
This connector is used to connect to the 480R. Cable lengths 480R to 480P - 300 feet max. 500 feet with dbx proprietary cable.
RS485 Link to Network Master (DB-9 connector type)
This connector is used to connect the 480R to the network master. Connect to the CONTROLLER IN on the Network master 480P to Network cable length- Up to 4000 feet.
RS485 Link to 480R (RJ-45 connector type)
This connector is used to connect to the 480R, and is wired in parallel with the DB-9 connector. Cable lengths 480R to 480P - 300 feet max. 500 feet with dbx proprietary cable.
RS485 Link to Network Master (RJ-45 connector type)
This connector is used to connect the 480R to the network master. Connect to the CONTROLLER IN on the Network master and is and is wired in parallel with the DB-9 connector. 480P to Network cable length- Up to 4000 feet.
RS232 PC Connection
This input is used to connect a PC to the 480R for 480R software updates.
RS485/ PC Select Button
This recessed button is used to select the link to master controller connector or the PC
480P Front Panel
Power Switch
Tu r ns the 480P and 480R on and off.
Specifications ( 480P Power Supply) Inputs
Connectors: RS 232 and RS 485 Network Communication
Connectors
Power Requirements
30 Watts Selectable
100-120V - 50/60Hz or 220-240V-
50/60Hz
Dimensions
Dimensions: Height: 1.75” X Width- 19” X Depth 7.90” Weight: 8 lbs. Shipping Weight: 9.5 lbs.
18-0294-A
WARNING FOR
YOUR PROTECTION
PLEASE READ THE FOLLOWING:
KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS CLEAN ONLY WITH A DAMP CLOTH. DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS.
DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTERS, STOVES; OR OTHER APPARATUS (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT
.
ONLY USE ATTACHMENTS/ACCESSORIES SPEC­IFIED BY THE MANUFACTURER.
UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERI­ODS OF TIME.
WATER AND MOISTURE: Appliance should not be used
near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.
POWER SOURCES: The appliance should be connected to a power supply only of the type described in the oper­ating instructions or as marked on the appliance.
GROUNDING OR POLARIZATION: Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.
POWER CORD PROTECTION: Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, conven­ience receptacles, and the point where they exit from the appliance.
SERVICING: To reduce the risk of fire or electric shock, the user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel.
FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSI­BLE FUSE RECEPTACLE: Replace fuse with same type
and rating only.
MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. Connect this equipment only to the power source indicated on the equipment rear panel. To reduce the risk of fire or electric shock, refer servicing to quali­fied service personnel or equivalent.
SAFETY INSTRUCTIONS
NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.
WARNING: THIS APPLIANCE MUST BE EARTHED. CAUTION: EQUIPMENT IS NOT
DISCONNECTED FROM
MAINS WHEN SWITCH IS IN THE OFF POSITION
The cores in the mains lead are coloured in accordance with the following code:
GREEN and YELLOW - Earth BLUE - Neutral
BROWN - Live
As colours of the cores in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
• The core which is coloured green and yellow must be connected to the terminal in the plug marked with the letter E, or with the earth symbol, or coloured green, or green and yellow.
• The core which is coloured blue must be con­nected to the terminal marked N or coloured black.
• The core which is coloured brown must be con­nected to the terminal marked L or coloured red.
This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If the attachment plug needs to be changed, refer servicing to qualified service personnel who should refer to the table below. The green/yellow wire shall be connected directly to the units chassis.
WARNING: If the ground is defeated, certain fault conditions in the unit or in the system to which it is connected can result in full line voltage between chassis and earth ground. Severe injury or death can then result if the chassis and earth ground are touched simultaneously.
The symbols shown above are internationally accepted symbols that warn of potential hazards with electrical products. The light­ning flash with arrowpoint in an equilateral triangle means that there are dangerous voltages present within the unit. The excla­mation point in an equilateral triangle indicates that it is neces­sary for the user to refer to the owner’s manual.
These symbols warn that there are no user serviceable parts inside the unit. Do not open the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified personnel. Opening the chassis for any reason will void the manufacturer’s warranty. Do not get the unit wet. If liquid is spilled on the unit, shut it off immediately and take it to a dealer for service. Disconnect the unit during storms to prevent damage.
IMPORTANT SAFETY INSTRUCTIONS
U.K. MAINS
PLUG WARNING
A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable disposal facility. NEVER UNDER ANY CIRCUMSTANCES SHOULD
YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET. Do not use the mains plug
without the fuse cover in place. Replacement fuse covers can be obtained from your local retailer. Replacement fuses are 13 amps and MUST be ASTA approved to BS1362.
LITHIUM BATTERY
WARNING
CAUTION!
This product may contain a lithium battery.There is danger of explosion if the battery is incorrectly replaced. Replace only with a Sony or equivalent bat­tery. Make sure the battery is installed with the cor­rect polarity. Discard used batteries according to man­ufacturer’s instructions.
ADVARSEL!
Lithiumbatteri - Eksplosjonsfare.Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndter­ing. Udskiftning må kun ske med batteri av samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
VAROITUS!
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittele­maan tyyppin. Hävitä käytetty paristo valmistajan ohjei­den mukaisesti.
VARNING!
Explosionsfara vid felaktigt batteribyte.Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
IMPORTANT SAFETY INSTRUCTIONS
ELECTROMAGNETIC
COMPATIBILITY
This unit conforms to the Product Specifications noted on the Declaration of Conformity. Operation is subject to the following two conditions:
• this device may not cause harmful interference, and
• this device must accept any interference received, including interference that may cause undesired operation.
Operation of this unit within significant electromagnetic fields should be avoided.
• use only shielded interconnecting cables.
DECLARATION OF
CONFORMITY
Manufacturer’s Name: dbx Professional
Products
Manufacturer’s Address:
8760 S. Sandy Parkway
Sandy, Utah 84070, USA
declares that the product:
Product name: dbx DriveRack™ 480P
Product option: None
conforms to the following Product Specifications:
Safety: EN 60065 (1993)
IEC 60065 (1998) CAN/CSA E60065-99
EMC: EN 55013 (1990)
EN 55020 (1991)
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC as amended by Directive 93/68/EEC.
dbx Professional Products Vice-President of Engineering 8760 S. Sandy Parkway Sandy, Utah 84070, USA March 15th, 2000
European Contact: Your Local dbx Sales and Service Office or
Harman Music Group 8760 South Sandy Parkway Sandy, Utah 84070 USA PH: (801) 568-7533 FX: (801) 568-7583
CAUTION
RISK OF ELECTRIC SHOCK
ATTENTION: WARNING:
SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR
TO REDUCE THE RISK OF FIRE OR ELECTRIC
CONDUCTOR
LIVE
L
NEUTRAL
N
E
EARTH GND
WIRE COLOR
Normal Alt
BROWN
BLUE
GREEN/YEL
BLACK
WHITE
GREEN
Loading...