FW803 PHY IEEE * 1394A Three-Cable Transceiver/Arbiter Device
Supports LPS/link-on as a part of PHY-link interface.

Distinguishing Features

Compliant with IEEE P1394a Draft 2.0 Standard for a High Performance Serial Bus (Supplement)
Supports extended BIAS_HANDSHAKE time for
enhanced interoperability with camcorders.
While unpowered and connected to the bus, will not
drive TPBIAS on a connected port even if receiving incoming bias voltage on that port.
Does not require external filter capacitors for PLL.
Does not require a separate 5 V supply for 5 V link
controller interoperability.
Interoperable across 1394 cable with 1394 physical
layers (PHY) using 5 V supplies.
Interoperable with 1394 link-layer controllers using
5 V supplies.
Powerdown features to conserve energy in battery-
powered applications include: — Device powerdown pin. — Link interface disable using LPS. — Inactive ports power down.
Interface to link-layer controller supports Annex J
electrical isolation as well as bus-keeper isolation.

Features

Supports provisions of IEEE 1394-1995 Standard for
a High Performance Serial Bus.
Fully interoperable with FireWire† implementation of
IEEE 1394-1995.
Reports cable power fail interrupt when voltage at
CPS pin falls below 7.5 V.
Separate cable bias and driver termination voltage
supply for each port.

Other Features

64-pin TQFP package.
Single 3.3 V supply operation.
Data interface to link-layer controller provided
through 2/4/8 parallel lines at 50 Mbits/s.
25 MHz crystal oscillator and PLL provide transmit/
receive data at 100 Mbits/s, 200 Mbits/s, and 400 Mbits/s, and link-layer controller clock at 50 MHz.
Node power-class information signaling for system
power management.
Multiple separate package signals provided for ana-
log and digital supplies and grounds.
Data Sheet, Rev. 3
June 2001
Provides three fully compliant cable ports at
100 Mbits/s, 200 Mbits/s, and 400 Mbits/s.
Fully supports open HCI requirements.
Supports arbitrated short bus reset to improve
utilization of the bus.
Supports ack-accelerated arbitration and fly-by con-
catenation.
Supports connection debounce.
Supports multispeed packet concatenation.
Supports PHY pinging and remote PHY access
packets.
Fully supports suspend/resume.
Supports PHY-link interface initialization and reset.
Supports 1394a-2000 register set.

Description

The Agere Systems Inc. FW803 device provides the analog physical layer functions needed to implement a three-port node in a cable-based IEEE 1394-1995 and IEEE 1394a-2000 network.
* IEEE is a registered trademark of The Institute of Electrical and
Electronics Engineers, Inc.
FireWire is a registered trademark of Apple Computer, Inc.
Page 2
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Table of Contents
Contents Page
Distinguishing Features ............................................................................................................................................ 1
Features ...................................................................................................................................................................1
Other Features ......................................................................................................................................................... 1
Description ................................................................................................................................................................1
Signal Information ..................................................................................................................................................... 6
Application Information ........................................................................................................................................... 10
Crystal Selection Considerations ............................................................................................................................ 11
1394 Application Support Contact Information ....................................................................................................... 12
Absolute Maximum Ratings .................................................................................................................................... 12
Electrical Characteristics ........................................................................................................................................13
Timing Characteristics ............................................................................................................................................16
Timing Waveforms .................................................................................................................................................. 17
Internal Register Configuration ............................................................................................................................... 18
Outline Diagrams .................................................................................................................................................... 23
Ordering Information ............................................................................................................................................... 23
List of Figures

Figures Page

Figure 1. Block Diagram ........................................................................................................................................... 5
Figure 2. Pin Assignments ........................................................................................................................................ 6
Figure 3. Typical External Component Connections ..............................................................................................10
Figure 4. Typical Port Termination Network ........................................................................................................... 11
Figure 5. Dn, CTLn, and LREQ Input Setup and Hold Times Waveforms ............................................................. 17
Figure 6. Dn, CTLn Output Delay Relative to SYSCLK Waveforms ....................................................................... 17
List of Tables

Table s Page

Table 1. Signal Descriptions ..................................................................................................................................... 7
Table 2. Absolute Maximum Ratings ...................................................................................................................... 12
Table 3. Analog Characteristics .............................................................................................................................. 13
Table 4. Driver Characteristics ............................................................................................................................... 14
Table 5. Device Characteristics ..............................................................................................................................15
Table 6. Switching Characteristics ......................................................................................................................... 16
Table 7. Clock Characteristics ...............................................................................................................................16
Table 8. PHY Register Map for the Cable Environment .........................................................................................18
Table 9. PHY Register Fields for the Cable Environment ...................................................................................... 18
Table 10. PHY Register Page 0: Port Status Page ................................................................................................ 20
Table 11. PHY Register Port Status Page Fields .................................................................................................. 21
Table 12. PHY Register Page 1: Vendor Identification Page .................................................................................22
Table 13. PHY Register Vendor Identification Page Fields .................................................................................... 22
22 Agere Systems Inc.
Page 3
Data Sheet, Rev. 3 FW803 PHY IEEE 1394A June 2001 Three-Cable Transceiver/Arbiter Device
Description
Each cable port incorporates two differential line trans­ceivers. The transceivers include circuitry to monitor the line conditions as needed for determining connec­tion status, for initialization and arbitration, and for packet reception and transmission. The PHY is designed to interface with a link-layer controller (LLC).
The PHY requires either an external 24.576 MHz crystal or crystal oscillator. The internal oscillator drives an internal phase-locked loop (PLL), which generates the required 400 MHz reference signal. The 400 MHz reference signal is internally divided to provide the 49.152 MHz, 98.304 MHz, and
196.608 MHz clock signals that control transmission of the outbound encoded strobe and data information. The 49.152 MHz clock signal is also supplied to the associated LLC for synchronization of the two chips and is used for resynchronization of the received data. The powerdown function, when enabled by the PD signal high, stops operation of the PLL and disables all circuitry except the cable-not-active signal circuitry.
The PHY supports an isolation barrier between itself and its LLC. When /ISO is tied high, the link interface outputs behave normally. When /ISO is tied low, internal differentiating logic is enabled, and the outputs become short pulses, which can be coupled through a capacitor or transformer as described in the IEEE 1394-1995 Annex J. To operate with bus-keeper isolation, the /ISO pin of the FW803 must be tied high.
Data bits to be transmitted through the cable ports are received from the LLC on two, four, or eight data lines (D[0:7]), and are latched internally in the PHY in synchronization with the 49.152 MHz system clock. These bits are combined serially, encoded, and transmitted at 98.304 Mbits/s, 196.608 Mbits/s, or
393.216 Mbits/s as the outbound data-strobe information stream. During transmission, the encoded data information is transmitted differentially on the TPA and TPB cable pair(s).
During packet reception, the TPA and TPB transmitters of the receiving cable port are disabled, and the receivers for that port are enabled. The encoded data information is received on the TPA and TPB cable pair. The received data-strobe information is decoded to recover the receive clock signal and the serial data bits. The serial data bits are split into two, four, or eight parallel streams, resynchronized to the local system clock, and sent to the associated LLC. The received data is also transmitted (repeated) out of the other active (connected) cable ports.
(continued)
Both the TPA and TPB cable interfaces incorporate differential comparators to monitor the line states during initialization and arbitration. The outputs of these comparators are used by the internal logic to determine the arbitration status. The TPA channel monitors the incoming cable common-mode voltage. The value of this common-mode voltage is used during arbitration to set the speed of the next packet transmission. In addition, the TPB channel monitors the incoming cable common-mode voltage for the presence of the remotely supplied twisted-pair bias voltage. This monitor is called bias-detect.
The TPBIAS circuit monitors the value of incoming TPA pair common-mode voltage when local TPBIAS is inactive. Because this circuit has an internal current source and the connected node has a current sink, the monitored value indicates the cable connection status. This monitor is called connect-detect.
Both the TPB bias-detect monitor and TPBIAS connect-detect monitor are used in suspend/resume signaling and cable connection detection.
The PHY provides a 1.86 V nominal bias voltage for driver load termination. This bias voltage, when seen through a cable by a remote receiver, indicates the presence of an active connection. The value of this bias voltage has been chosen to allow interoperability between transceiver chips operating from 5 V or 3 V nominal supplies. This bias voltage source should be stabilized by using an external filter capacitor of approximately 0.33 µF.
The transmitter circuitry, the receiver circuitry, and the twisted-pair bias voltage circuity are all disabled with a powerdown condition. The powerdown condition occurs when the PD input is high. The port transmitter circuitry, the receiver circuitry, and the TPBIAS output are also disabled when the port is disabled, suspended, or disconnected.
The line drivers in the PHY operate in a high­impedance current mode and are designed to work with external 112 line-termination resistor networks. One network is provided at each end of each twisted­pair cable. Each network is composed of a pair of series-connected 56 resistors. The midpoint of the pair of resistors that is directly connected to the twisted-pair A (TPA) signals is connected to the TPBIAS voltage signal. The midpoint of the pair of resistors that is directly connected to the twisted-pair B (TPB) signals is coupled to ground through a parallel RC network with recommended resistor and capacitor values of 5 k and 220 pF, respectively.
Lucent Technologies Inc. 3
Page 4
FW803 PHY IEEE 1394A Data Sheet, Rev. 3 Three-Cable Transceiver/Arbiter Device June 2001
Description
The value of the external resistors are specified to meet the standard specifications when connected in parallel with the internal receiver circuits.
The driver output current, along with other internal operating currents, is set by an external resistor. This resistor is connected between the R0 and R1 signals and has a value of 2.49 kΩ ± 1%.
The FW803 supports suspend/resume as defined in the IEEE 1394a-2000 specification. The suspend mechanism allows an FW803 port to be put into a suspended state. In this state, a port is unable to transmit or receive data packets, however, it remains capable of detecting connection status changes and detecting incoming TPBias. When all ports of the FW803 are suspended, all circuits except the bias voltage reference generator, and bias detection circuits are powered down, resulting in significant power savings. The use of suspend/resume is recommended.
Four signals are used as inputs to set four configuration status bits in the self-identification (self­ID) packet. These signals are hardwired high or low as a function of the equipment design. PC[0:2] are the three signals that indicate either the need for power from the cable or the ability to supply power to the cable. The fourth signal, C/LKON, as an input, indicates whether a node is a contender for bus manager. When the C/LKON signal is asserted, it means the node is a contender for bus manager. When the signal is not asserted, it means that the node is not a contender. The C bit corresponds to bit 20 in the self-ID packet, PC0 corresponds to bit 21, PC1 corresponds to bit 22, and PC2 corresponds to bit 23 (see Table 4-29 of the IEEE 1394-1995 standard for additional details).
A powerdown signal (PD) is provided to allow a powerdown mode where most of the PHY circuits are powered down to conserve energy in battery-powered applications. The internal logic in FW803 is reset as long as the powerdown signal is asserted. A cable status signal, CNA, provides a high output when none of the twisted-pair cable ports are receiving incoming bias voltage. This output is not debounced. The CNA output can be used to determine when to power the PHY down or up. In the powerdown mode, all circuitry is disabled except the CNA circuitry. It should be noted that when the device is powered down, it does not act in a repeater mode.
(continued)
When the power supply of the PHY is removed while the twisted-pair cables are connected, the PHY transmitter and receiver circuitry has been designed to present a high impedance to the cable in order to not load the TPBIAS signal voltage on the other end of the cable.
For reliable operation, the TPBn signals must be terminated using the normal termination network regardless of whether a cable is connected to a port or not connected to a port. For those applications, when FW803 is used with one or more of the ports not brought out to a connector, those unused ports may be left unconnected without normal termination. When a port does not have a cable connected, internal connect-detect circuitry will keep the port in a disconnected state.
Note: All gap counts on all nodes of a 1394 bus must
be identical. This may be accomplished by using PHY configuration packets (see Section 4.3.4.3 of IEEE 1394-1995 standard) or by using two bus resets, which resets the gap counts to the maximum level (3Fh).
The link power status (LPS) signal works with the C/LKON signal to manage the LLC power usage of the node. The LPS signal indicates that the LLC of the node is powered up or powered down. If LPS is inac­tive for more than 1.2 µs and less than 25 µs, PHY/link interface is reset. If LPS is inactive for greater than 25 µs, the PHY will disable the PHY/link interface to save power. FW803 continues its repeater function. If the PHY then receives a link-on packet, the C/LKON signal is activated to output a 6.114 MHz signal, which can be used by the LLC to power itself up. Once the LLC is powered up, the LPS signal communicates this to the PHY and the PHY/link interface is enabled. C/LKON signal is turned off when LPS is active or when a bus reset occurs, provided the interrupt that caused C/LKON is not present.
Two of the signals are used to set up various test conditions used in manufacturing. These signals, SE and SM, should be connected to V operation.
SS
for normal
4 Lucent Technologies Inc.
Page 5
Data Sheet, Rev. 3 FW803 PHY IEEE 1394A June 2001 Three-Cable Transceiver/Arbiter Device
Description
SYSCLK
LREQ
CTL0
CTL1
PC0
PC1
PC2
C/LKON
SE
SM
(continued)
CPS
LPS
/ISO
CNA
D0 D1 D2 D3 D4 D5 D6 D7
LINK
INTERFACE
I/O
RECEIVED
DATA
DECODER/
RETIMER
ARBITRATION
AND
CONTROL
STATE
MACHINE
LOGIC
BIAS
VOLTAGE
AND
CURRENT
GENERATOR
CABLE PORT 0
R0
R1
TPA0+ TPA0–
TPBIAS0
TPB0+ TPB0–
PD
/RESET
TRANSMIT
DATA
ENCODER

Figure 1. Block Diagram

CABLE PORT 1
CABLE PORT 2
CRYSTAL OSCILLATOR, PLL SYSTEM,
AND
CLOCK
GENERATOR
TPA1+
TPA1–
TPBIAS1
TPB1+
TPB1–
TPA2+
TPA2–
TPBIAS2
TPB2+
TPB2–
XI
XO
5-5459.d (F)
Lucent Technologies Inc. 5
Page 6
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device

Signal Information

LREQ
V
CTL0
CTL1
D0
D1
V
DD
D2
D3
D4
D5
D6
D7
V
CNA
LPS
SS
V
63
64
1
2
SS
3
4
5
6
7
8
9
10
11
12
13
14
SS
15
16
PIN #1 IDENTIFIER
17
18
XO
/RESET
VDDSYSCLK
59
60
61
62
AGERE FW803
19
20
21
22
Data Sheet, Rev. 3
June 2001
SSAVDDA
DDA
SSAVSSA
V
R0
R1
VSSPLLVDDPLLVSSXI
52
53
54
55
56
57
58
23
24
25
26
27
28
29
V
V
49
50
51
30
48
TPBIAS2
47
TPA2+
46
TPA2–
45
TPB2+
44
TPB2–
43
V
DDA
42
TPBIAS1
41
TPA1+
40
TPA1–
39
TPB1+
38
TPB1–
37
TPBIAS0
36
TPA0+
35
TPA0–
34
TPB0+
33
TPB0–
31
32
DD
V
C/LKON
PD
PC0
PC1
PC2
SS
DD
SE
SM
V
/ISO
VDDV
CPS
DDAVDDA
V
Note: Active-low signals are indicated by “/” at the beginning of signal names, within this document.

Figure 2. Pin Assignments

SSA
V
5-6236.b (F)
66 Agere Systems Inc.
Page 7
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Signal Information
Table 1. Signal Descriptions
Pin Signal* Type Name/Description
18 C/LKON I/O Bus Manager Capable Input and Link-On Output. On hardware reset,
15 CNA O Cable-Not-Active Output. CNA is asserted high when none of the PHY
24 CPS I Cable Power Status. CPS is normally connected to the cable power
3 CTL0 I/O Control I/O. The CTLn signals are bidirectional communications control
4CTL1
5, 6, 8,
9, 10, 11,
12, 13
23 /ISO I Link Interface Isolation Disable Input (Active-Low). /ISO controls the
* Active-low signals are indicated by “/ ” at the beginning of signal names, within this document.
D[0:7] I/O Data I/O. The Dn signals are bidirectional and pass data between the
(continued)
this pin is used to set the default value of the contender status indicated during self-ID. The bit value programming is done by tying the signal through a 10 k resistor to V (low, not bus manager capable). Using either the pull-up or pull-down resistor allows the link-on output to override the input value when neces­sary.
After hardware reset, this pin is set as an output.
C/LKON indicates one of the following events by asserting a 6.114 MHz signal.
1. FW803 receives a link-on packet addressed to this node.
2. Port_event register bit is 1.
3. Any of the Timeout, Pwr_Fail, or Loop register bits are 1 and the Resume_int register bit is also 1. Once activated, the C/LKON output will continue active until the LPS becomes active. The PHY also deasserts the C/LKON output when a bus reset occurs, if the C/LKON is active due solely to the reception of a link-on packet.
Note:
ports are receiving an incoming bias voltage. This circuit
during the powerdown mode.
through a 400 k resistor. This circuit drives an internal comparator that detects the presence of cable power. This information is maintained in one internal register and is available to the LLC by way of a register read (see Table 8,
signals between the PHY and the LLC. These signals control the passage of information between the two devices. Bus-keeper circuitry is built into these terminals.
PHY and the LLC. Bus-keeper circuitry is built into these terminals.
operation of an internal pulse differentiating function used on the PHY-LLC interface signals, CTLn and Dn, when they operate as outputs. When /ISO is asserted low, the isolation barrier is implemented between PHY and its LLC (as described in Annex J of IEEE 1394-1995). /ISO is normally tied high to disable isolation differentiation. Bus-keepers are enabled when /ISO is high (inactive) on CTL, D, and LREQ. When /ISO is low (active), the bus-keepers are disabled. Please refer to Agere’s application note AP98-074CMPR for more information on isolation.
If an interrupt condition exists which would otherwise cause the C/LKON output to be activated if the LPS were inactive, the C/LKON output will be activated when the LPS subsequently becomes inac­tive.
Register 0
DD (high, bus manager capable) or to GND
If the LPS is inactive,
remains active
).
Agere Systems Inc. 7
Page 8
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Signal Information
(continued)
Table 1. Signal Descriptions (continued)
Pin Signal* Type Name/Description
DD
16 LPS I Link Power Status. LPS is connected to either the V
supplying the LLC or to a pulsed output that is active when the LLC is powered for the purpose of monitoring the LLC power status. If LPS is inactive for more than 1.2 µs and less than 25 µs, interface is reset. If LPS is inactive for greater than 25 µs, the PHY will disable the PHY/Link interface to save power. FW803 continues its repeater function.
1LREQ ILink Request. LREQ is an output from the LLC that requests the PHY to
perform some service. Bus-keeper circuitry is built into this terminal.
20 PC0 I Power-Class Indicators. On hardware reset, these inputs set the default
21 PC1
22 PC2
value of the power class indicated during self-ID. These bits can be programmed by tying the signals to V
DD
(high) or to ground (low).
19 PD I Powerdown. When asserted high, PD turns off all internal circuitry except
the bias-detect circuits that drive the CNA signal.
57 PLLV
DD
Power for PLL Circuit. PLLV
DD
supplies power to the PLL circuitry
portion of the device.
58 PLLV
SS
Ground for PLL Circuit. PLLVSS is tied to a low-impedance ground
plane.
54 R0 I Current Setting Resistor. An internal reference voltage is applied to a
resistor connected between R0 and R1 to set the operating current and the cable driver output current. A low temperature-coefficient resistor
55 R1
(TCR) with a value of 2.49 kΩ ± 1% should be used to meet the IEEE 1394-1995 standard requirements for output voltage limits.
61 /RESET I Reset (Active-Low). When /RESET is asserted low (active), the FW803
is reset. An internal pull-up resistor, which is connected to VDD, is provided, so only an external delay capacitor is required to ensure that the capacitor is discharged when PHY power is removed. This input is a stan­dard logic buffer and can also be driven by an open-drain logic output buffer.
28 SE I Test Mode Control. SE is used during the manufacturing test and should
be tied to V
SS.
29 SM I Test Mode Control. SM is used during the manufacturing test and should
be tied to V
SS.
63 SYSCLK O System Clock. SYSCLK provides a 49.152 MHz clock signal, which is
synchronized with the data transfers to the LLC.
36 TPA0+ Analog I/O Portn, Port Cable Pair A. TPAn is the port A connection to the twisted-
41 TPA1+
47 TPA2+
pair cable. Board traces from each pair of positive and negative differen­tial signal pins should be kept matched and as short as possible to the external load resistors and to the cable connector.
35 TPA0 Analog I/O Portn, Port Cable Pair A. TPAn is the port A connection to the twisted-
40 TPA1
46 TPA2
* Active-low signals are indicated by “/ ” at the beginning of signal names, within this document.
pair cable. Board traces from each pair of positive and negative differen­tial signal pins should be kept matched and as short as possible to the external load resistors and to the cable connector.
88 Agere Systems Inc.
Page 9
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Signal Information
Table 1. Signal Descriptions (continued)
Pin Signal* Type Name/Description
34 TPB0+ Analog I/O Portn, Port Cable Pair B. TPBn is the port B connection to the twisted-
39 TPB1+
45 TPB2+
33 TPB0 Analog I/O Portn, Port Cable Pair B. TPBn is the port B connection to the twisted-
38 TPB1
44 TPB2
37 TPBIAS0 Analog I/O Portn, Twisted-Pair Bias. TPBIAS provides the 1.86 V nominal bias
42 TPBIAS1
48 TPBIAS2
7, 17,
26, 27, 62
30, 31,
43, 50, 51
2, 14,
25, 56, 64
32, 49,
52, 53
59 XI Crystal Oscillator. XI and XO connect to a 24.576 MHz parallel resonant
60 XO
* Active-low signals are indicated by “/ ” at the beginning of signal names, within this document.
V
DD Digital Power. VDD supplies power to the digital portion of the device.
V
DDA Analog Circuit Power. VDDA
SS Digital Ground. All VSS signals should be tied to the low-impedance
V
V
SSA Analog Circuit Ground. All VSSA signals should be tied together to a low-
(continued)
pair cable. Board traces from each pair of positive and negative differen­tial signal pins should be kept matched and as short as possible to the external load resistors and to the cable connector.
pair cable. Board traces from each pair of positive and negative differen­tial signal pins should be kept matched and as short as possible to the external load resistors and to the cable connector.
voltage needed for proper operation of the twisted-pair cable drivers and receivers and for sending a valid cable connection signal to the remote nodes.
supplies power to the analog portion of the
device.
ground plane.
impedance ground plane.
fundamental mode crystal. Although, when a 24.576 MHz clock source is used, it can be connected to XI with XO left unconnected. The optimum values for the external shunt capacitors are dependent on the specifica­tions of the crystal used. It is suggested that two 12 pF shunt capacitors be used for a crystal with a specified details, see Crystal Selection Considerations in the Application Informa­tion section.
pF loading capacitance. For more
7
Agere Systems Inc. 9
Page 10
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device

Application Information

12 pF 12 pF
0.1 µF
LLC
LLC PULSE
DD
OR V
LLC
LREQ
V
SS
CTL0
CTL1
D0
D1
V
DD
D2
D3
D4
D5
D6
D7
V
SS
CNA
LPS
SS
V
63
64
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
PIN #1 IDENTIFIER
17
181920
XO
/RESET
VDDSYSCLK
60
61
62
21
24.576 MHz
DD
VSSPLLV
PLLVSS
XI
56
57
58
59
AGERE FW803
22
23
24
Data Sheet, Rev. 3
June 2001
2.49 k
DDA
SSA
SSA
V
V
R0
R1
52
53
54
55
25
26
27
28
29
VSSA
VDDA
V
49
50
51
30
31
32
TPBIAS2
48
TPA2+
47
TPA2–
46
TPB2+
45
TPB2–
44
V
43
42
41
40
39
38
37
36
35
34
33
DDA
TPBIAS1
TPA1+
TPA1–
TPB1+
TPB1–
TPBIAS0
TPA0+
TPA0–
TPB0+
TPB0–
PORT 1*
PORT 0*
SS
DD
VDD
PD
PC0
PC1
PC2
/ISO
V
CPS
VDDV
SE
SM
DDA
V
VDDA
VSSA
C/LKON
10 k
400 k
POWER CLASS
CABLE
LKON
BUS
MANAGER
POWER
5-6767 (F)
* See Figure 4 for typical port termination network.

Figure 3. Typical External Component Connections

1010 Agere Systems Inc.
Page 11
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Application Information
42
41
40
39
38
37
36
35
34
33
TPBIAS1
TPA1+
TPA1–
TPB1+
TPB1–
TPBIAS0
56
TPA0+
TPA0–
TPB0+
TPB0–
56
TPBIAS1
56
56
(continued)
0.33 µF
USE SAME PORT TERMINATION NETWORK AS ILLUSTRATED BELOW.
5
3
6
IEEE 1394-1995 STANDARD
CONNECTOR
4
220 pF
5 k
CABLE
POWER
1
2
VGVP
5-6930 (F)

Figure 4. Typical Port Termination Network

Crystal Selection Considerations

The FW803 is designed to use an external 24.576 MHz crystal connected between the XI and XO terminals to pro­vide the reference for an internal oscillator circuit. IEEE 1394a-2000 standard requires that FW803 have less than ±100 ppm total variation from the nominal data rate, which is directly influenced by the crystal. To achieve this, it is recommended that an oscillator with a nominal 50 ppm or less frequency tolerance be used.
The total frequency variation must be kept below by board and device variations. Trade offs between frequency tolerance and stability may be made as long as the total frequency variation is less than
100 ppm.
±
Load Capacitance
100 ppm from nominal with some allowance for error introduced
±
The frequency of oscillation is dependent upon the load capacitance specified for the crystal, in parallel resonant mode crystal circuits. Total load capacitance (CL) is a function of not only the discrete load capacitors, but also capacitances from the FW803 board traces and capacitances of the other FW803 connected components.
Agere Systems Inc. 11
Page 12
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Crystal Selection Considerations
Load Capacitance
The values for load capacitors (CA and CB) should be calculated using this formula:
C
= CB = (CL – C
A
Where:
C
= load capacitance specified by the crystal manufacturer
L
C
= capacitance of the board and the FW803, typically 2—3 pF
stray
Board Layou
The layout of the crystal portion of the PHY circuit is important for obtaining the correct frequency and minimizing noise introduced into the FW803 PLL. The crystal and two load capacitors should be considered as a unit during lay­out. They should be placed as close as possible to one another, while minimizing the loop area created by the com­bination of the three components. Minimizing the loop area minimizes the effect of the resonant current that flows in this resonant circuit. This layout unit (crystal and load capacitors) should then be placed as close as possible to the PHY XI and XO terminals to minimize trace lengths. Vias should not be used to route the XI and XO signals.
t
(continued)
) × 2
stray
(continued)

1394 Application Support Contact Information

E-mail: 1394support@agere.com

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso­lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended peri­ods can adversely affect device reliability.

Table 2. Absolute Maximum Ratings

Parameter Symbol Min Max Unit
Supply Voltage Range V
Input Voltage Range* V
Output Voltage Range at Any Output V
Operating Free Air Temperature T
Storage Temperature Range T
* Except for 5 V tolerant I/O (CTL0, CTL1, D0—D7, and LREQ) where VI max = 5.5 V.
DD
I
O
A
stg
3.0 3.6 V
0.5 V
0.5 V
DD + 0.5 V
DD + 0.5 V
070°C
–65 150 °C
1212 Agere Systems Inc.
Page 13
Data Sheet, Rev. 3 June 2001
Three-Cable Transceiver/Arbiter Device

Electrical Characteristics

Table 3. Analog Characteristics

Parameter Test Conditions Symbol Min Typ Max Unit
Supply Voltage Source power node V Differential Input Voltage Cable inputs, 100 Mbits/s operation V
Cable inputs, 200 Mbits/s operation V Cable inputs, 400 Mbits/s operation V
Cable inputs, during arbitration V
Common-mode Voltage
Source Power Mode
Common-mode Voltage
Nonsource Power Mode*
Receive Input Jitter TPA, TPB cable inputs,
Receive Input Skew Between TPA and TPB cable inputs,
Between TPA and TPB cable inputs,
Between TPA and TPB cable inputs,
Positive Arbitration
Comparator Input Threshold Voltage
Negative Arbitration
Comparator Input Threshold Voltage
Speed Signal Input
Threshold Voltage
Output Current TPBIAS outputs I TPBIAS Output Voltage At rated I/O current V Current Source for
Connect Detect Circuit
* For a node that does not source power (see Section 4.2.2.2 in IEEE 1394-1995 Standard).
TPB cable inputs,
speed signaling off
TPB cable inputs,
S100 speed signaling on
TPB cable inputs,
S200 speed signaling on
TPB cable inputs,
S400 speed signaling on
TPB cable inputs,
speed signaling off
TPB cable inputs,
S100 speed signaling on
TPB cable inputs,
S200 speed signaling on
TPB cable inputs,
S400 speed signaling on
100 Mbits/s operation
TPA, TPB cable inputs,
200 Mbits/s operation
TPA, TPB cable inputs,
400 Mbits/s operation
100 Mbits/s operation
200 Mbits/s operation
400 Mbits/s operation
—V
—V
200 Mbits/s V 400 Mbits/s V
—I
CM—SP—100
V
CM—SP—200 0.935 2.515 V
V
CM—SP—400 0.532 2.515 V
V
CM—NSP—100 1.165 2.015 V
V
CM—NSP—200 0.935 2.015 V
V
CM—NSP—400 0.532 2.015 V
V
FW803 PHY IEEE 1394A
DD—SP 3.0 3.3 3.6 V
ID—100 ID—200 132 260 mV ID—400 100 260 mV
ID—ARB 168 265 mV
V
CM 1.165 2.515 V
VCM 1.165 2.015 V
——1.08ns
——0.5ns
——0.315ns
——0.8ns
——0.55ns
——0.5ns
TH
+89168mV
TH
–168 –89 mV
TH—S200 45 139 mV TH—S400 266 445 mV
O –5 2.5 mA
O
CD ——76µA
142 260 mV
1.165 2.515 V
1.665 2.015 V
Agere Systems Inc. 13
Page 14
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Electrical Characteristics
(continued)

Table 4. Driver Characteristics

Parameter Test Conditions Symbol Min Typ Max Unit
Differential Output Voltage 56 Ω load V
Off-state Common-mode Voltage Drivers disabled V
Driver Differential Current,
TPA+, TPA, TPB+, TPB
Common-mode Speed Signaling
Current, TPB+, TPB
Driver enabled,
speed signaling off*
200 Mbits/s speed
signaling enabled
400 Mbits/s speed
signaling enabled
* Limits are defined as the algebraic sum of TPA+ and TPA driver currents. Limits also apply to TPB+ and TPB as the algebraic sum of driver
currents.
† Limits are defined as the absolute limit of each of TPB+ and TPB driver currents.
OD 172 265 mV
OFF ——20mV
IDIFF
ISP
SP
I
1.05 1.05 mA
2.53 4.84 mA
8.1 12.4 mA
1414 Agere Systems Inc.
Page 15
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Electrical Characteristics
(continued)

Table 5. Device Characteristics

Parameter Test Conditions Symbol Min Typ Max Unit
Supply Current:
V
DD = 3.3 V
One Port Active
All Ports Active No Ports Active, LPS = 0 PD = 1
High-level Output Voltage I
Low-level Output Voltage I
OH max, VDD = min VOH VDD – 0.4 V
OL min, VDD = max VOL ——0.4V
High-level Input Voltage CMOS inputs V
Low-level Input Voltage CMOS inputs V
Pull-up Current,
V
I = 0 V II 11 32 µA
/RESET Input
Powerup Reset Time,
V
I = 0 V 2 ms
/RESET Input
Rising Input Threshold Voltage
—VI
/RESET Input
Output Current SYSCLK I
Control, data I
@ CMOS
CNA I
C/LKON I
Input Current,
V
I
= V
DD
or 0 V I LREQ, LPS, PD, SE, SM, PC[0:2] Inputs
Off-state Output Current,
O = VDD or 0 V IOZ ——°±5 µA
V
CTL[0:1], D[0:7], C/LKON I/Os
Power Status Input Threshold
400 k resistor V
Voltage, CPS Input
Rising Input Threshold Voltage*,
—V
LREQ, CTLn, Dn
Falling Input Threshold Voltage*,
—V
LREQ, CTLn, Dn
Bus Holding Current,
V
I = 1/2(VDD) 250 550 µA
LREQ, CTLn, Dn
Rising Input Threshold Voltage
—V
LPS
Falling Input Threshold Voltage
—V
LPS
* Device is capable of both differentiated and undifferentiated operation.
I
DD
IDD IDD IDD
IH
IL 0.2VDD V
RST 1.1 1.4 V
OL/IOH
— — — —
DD
0.7V
–16 16 mA
1
13
1
51
85
1
—— V
— — — —
mA mA mA mA
@ TTL
OL/IOH
OL/IOH –16 16 mA
OL/IOH –2 2 mA
I
TH 7.5 8.5 V
IT+VDD/2 + 0.3 VDD/2 + 0.8 V
IT
V
LIH
LIL 0.24VDD + 0.2 V
–12 12 mA
——°±1 µA
DD
/2 – 0.8 VDD/2 – 0.3 V
0.24VDD + 1 V
Agere Systems Inc. 15
Page 16
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001

Timing Characteristics

Table 6. Switching Characteristics

Symbol Parameter Measured Test Conditions Min Typ Max Unit
Jitter, Transmit TPA, TPB 0.15 ns
Transmit Skew Between
TPA and TPB
tr Rise Time, Transmit (TPA/TPB) 10% to 90% RI = 56 Ω,
t
f Fall Time, Transmit (TPA/TPB) 90% to 10% RI = 56 Ω,
t
su
Setup Time,
50% to 50% See Figure 5 6 ns
Dn, CTLn, LREQ↑↓ to SYSCLK
t
h Hold Time,
50% to 50% See Figure 5 0 ns
Dn, CTLn, LREQ↑↓ from SYSCLK
t
d Delay Time,
50% to 50% See Figure 6 1 6 ns
SYSCLK to Dn, CTLn↑↓
——±0.1 ns
——1.2ns
C
I = 10 pF
——1.2ns
C
I = 10 pF

Table 7. Clock Characteristics

Parameter Symbol Min Typ Max Unit
External Clock Source Frequency f 24.5735 24.5760 24.5785 MHz
1616 Agere Systems Inc.
Page 17
Data Sheet, Rev. 3 June 2001

Timing Waveforms

Figure 5. Dn, CTLn, and LREQ Input Setup and Hold Times Waveforms

FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
SYSCLK
th
tsu
Dn, CTLn, LREQ
5-6017.a (F)
SYSCLK
td
Dn, CTLn

Figure 6. Dn, CTLn Output Delay Relative to SYSCLK Waveforms

5-6018.a (F)
Agere Systems Inc. 17
Page 18
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device

Internal Register Configuration

The PHY register map is shown below in Table 8.

Table 8. PHY Register Map for the Cable Environment

Address Contents
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
2 Physical_ID R PS
0000
0001
2 RHB IBR Gap_count
0010
2 Extended (7)
0011
2 Max_speed
0100
2
0101
2 Resume_int ISBR Loop Pwr_fail Timeout Port_event Enab_accel Enab_multi
0110
2
01112 Page_select
1000
2 Register 0 Page_select
LCtrl
XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX
Contender Jitter Pwr_class
XXXXX XXXXX
XXXXX
Data Sheet, Rev. 3
June 2001
Tot al _p or ts
Delay
Port_select
11112 Register 7 Page_select
REQUIRED
The meaning of the register fields within the PHY register map are defined by Table 9 below. Power reset values not specified are resolved by the operation of the PHY state machines subsequent to a power reset.

Table 9. PHY Register Fields for the Cable Environment

Field Size Type Power Reset
Value
Physical_ID 6 r 000000 The address of this node determined during self-identification. A
R 1 r 0 When set to one, indicates that this node is the root.
PS 1 r Cable power active.
RHB 1 rw 0 Root hold-off bit. When set to one, the force_root variable is TRUE,
IBR 1 rw 0 Initiate bus reset. When set to one, instructs the PHY to set ibr
Gap_count 6 rw 3F
Extended 3 r 7 This field has a constant value of seven, which indicates the
16 Used to configure the arbitration timer setting in order to optimize
XXXXX
value of 63 indicates a malconfigured bus; the link will not transmit any packets.
which instructs the PHY to attempt to become the root during the next tree identify process.
TRUE and reset_time to RESET_TIME. These values in turn cause the PHY to initiate a bus reset without arbitration; the reset signal is asserted for 166 µs. This bit is self-clearing.
gap times according to the topology of the bus. See Section 4.3.6 of IEEE Standard 1394-1995 for the encoding of this field.
extended PHY register map.
RESERVED
Description
1818 Agere Systems Inc.
Page 19
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Internal Register Configuration
(continued)
Table 9. PHY Register Fields for the Cable Environment (continued)
Field Size Type Power Reset Value Description
Total_ports 4 r 3 The number of ports implemented by this PHY. This count
reflects the number.
Max_speed 3 r 010
2 Indicates the speed(s) this PHY supports:
000
2 = 98.304 Mbits/s
001
2 = 98.304 and 196.608 Mbits/s
010
2 = 98.304, 196.608, and 393.216 Mbits/s
011
2 = 98.304, 196.608, 393.216, and 786.43 Mbits/s
100
2 = 98.304, 196.608, 393.216, 786.432, and
1,572.864 Mbits/s
101
2 = 98.304, 196.608, 393.216, 786.432, 1,572.864, and
3,145.728 Mbits/s
All other values are reserved for future definition.
Delay 4 r 0000 Worst-case repeater delay, expressed as 144 + (delay * 20) ns.
LCtrl
1rw 1 Link Active. Cleared or set by software to control the value of
the L bit transmitted in the node’s self-ID packet 0, which will be the logical AND of this bit and LPS active.
Contender 1 rw See description. Cleared or set by software to control the value of the C bit
transmitted in the self-ID packet. Powerup reset value is set by C/LKON pin.
Jitter 3 r 000 The difference between the fastest and slowest repeater data
delay, expressed as (jitter + 1) * 20 ns.
Pwr_class 3 rw See description. Power-Class. Controls the value of the pwr field transmitted in
the self-ID packet. See Section 4.3.4.1 of IEEE Standard 1394­1995 for the encoding of this field. PC0, PC1, and PC2 pins set up power reset value.
Resume_int 1 rw 0 Resume Interrupt Enable. When set to one, the PHY will set
Port_event to one if resume operations commence for any port.
ISBR 1 rw 0 Initiate Short (Arbitrated) Bus Reset. A write of one to this bit
instructs the PHY to set ISBR true and reset_time to SHORT_RESET_TIME. These values in turn cause the PHY to arbitrate and issue a short bus reset. This bit is self-clearing.
Loop 1 rw 0 Loop Detect. A write of one to this bit clears it to zero.
Pwr_fail 1 rw
1
Cable Power Failure Detect. Set to one when the PS bit changes from one to zero. A write of one to this bit clears it to zero.
Timeout 1 rw 0 Arbitration State Machine Timeout. A write of one to this bit
clears it to zero (see MAX_ARB_STATE_TIME).
Port_event 1 rw 0 Port Event Detect. The PHY sets this bit to one if any of con-
nected, bias, disabled, or fault change for a port whose Int_enable bit is one. The PHY also sets this bit to one if resume operations commence for any port and Resume_int is one. A write of one to this bit clears it to zero.
Agere Systems Inc. 19
Page 20
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Internal Register Configuration
Table 9. PHY Register Fields for the Cable Environment (continued)
Field Size Type Power Reset
Value
Enab_accel 1 rw 0 Enable Arbitration Acceleration. When set to one, the PHY will
Enab_multi 1 rw 0 Enable multispeed packet concatenation. When set to one, the link
Page_select 3 rw 000 Selects which of eight possible PHY register pages are accessible
Port_select 4 rw 000 If the page selected by Page_select presents per-port information,
The port status page is used to access configuration and status information for each of the PHY’s ports. The port is selected by writing zero to Page_select and the desired port number to Port_select in the PHY register at address
2. The format of the port status page is illustrated by Table 10 below; reserved fields are shown shaded. The
0111 meanings of the register fields with the port status page are defined by Table 11.
(continued)
Description
use the enhancements specified in clause specification. PHY behavior is unspecified if the value of Enab_accel is changed while a bus request is pending.
will signal the speed of all packets to the PHY.
through the window at PHY register addresses 1000 1111
2, inclusive.
this field selects which port’s registers are accessible through the window at PHY register addresses 1000 Ports are numbered monotonically starting at zero, p0.
of 1394
8.11
2 through 11112, inclusive.
a-2000
2 through

Table 10. PHY Register Page 0: Port Status Page

Address Contents
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
1000
2 AStat BStat Child Connected Bias Disabled
1001
2 Negotiated_speed Int_enable Fault
10102
10112
11002
11012
11102
11112
XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX
REQUIRED
XXXXX
RESERVED
XXXXX XXXXX XXXXX
2020 Agere Systems Inc.
Page 21
Data Sheet, Rev. 3 June 2001
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
Internal Register Configuration
The meaning of the register fields with the port status page are defined by Table 11 below.

Table 11. PHY Register Port Status Page Fields

Field Size Type Power Reset
AStat 2 r TPA line state for the port:
BStat 2 r TPB line state for the port (same encoding as AStat).
Child 1 r 0 If equal to one, the port is a child; otherwise, a parent. The
Connected 1 r 0 If equal to one, the port is connected.
Bias 1 r 0 If equal to one, incoming TPBIAS is detected.
Disabled 1 rw 0 If equal to one, the port is disabled.
Negotiated_speed 3 r 000 Indicates the maximum speed negotiated between this PHY
Int_enable 1 rw 0 Enable port event interrupts. When set to one, the PHY will
Fault 1 rw 0 Set to one if an error is detected during a suspend or resume
(continued)
Value
Description
2 = invalid
00 01
2 = 1
10
2
= 0
11
2
= Z
meaning of this bit is undefined from the time a bus reset is detected until the PHY transitions to state T1: Child Hand­shake during the tree identify process (see Section 4.4.2.2 in IEEE Standard 1394-1995).
port and its immediately connected port; the encoding is the same as for they PHY register Max_speed field.
set Port_event to one if any of connected, bias, disabled, or fault (for this port) change state.
operation. A write of one to this bit clears it to zero.
Agere Systems Inc. 21
Page 22
FW803 PHY IEEE 1394A Three-Cable Transceiver/Arbiter Device
Data Sheet, Rev. 3
June 2001
Internal Register Configuration
The vendor identification page is used to identify the PHY’s vendor and compliance level. The page is selected by writing one to Page_select in the PHY register at address 0111 shown in Table 12; reserved fields are shown shaded.
(continued)
2
. The format of the vendor identification page is

Table 12. PHY Register Page 1: Vendor Identification Page

Address Contents
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
2 Compliance_level
1000
1001
2
XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX
10102
10112 Vendor_ID
1100
2
11012
11102 Product_ID
1111
2
REQUIRED
XXXXX
RESERVED
The meaning of the register fields within the vendor identification page are defined by Table 13.

Table 13. PHY Register Vendor Identification Page Fields

Field Size Type Description
Compliance_level 8 r Standard to which the PHY implementation complies:
0 = not specified 1 = IEEE 1394
a-2000
Agere’s FW803 compliance level is 1. All other values reserved for future standardization.
Vendor_ID 24 r The company ID or organizationally unique identifier (OUI) of the manufacturer
of the PHY. Agere’s vendor ID is 00601D
16. This number is obtained from the
IEEE registration authority committee (RAC). The most significant byte of Vendor_ID appears at PHY register location 1010 1100
2.
2 and the least significant at
Product_ID 24 r The meaning of this number is determined by the company or organization that
has been granted Vendor_ID. Agere’s FW803 product ID is 081402 significant byte of Product_ID appears at PHY register location 1101 least significant at 1111
2
.
16
. The most
2
and the
The vendor-dependent page provides access to information used in manufacturing test of the FW803.
2222 Agere Systems Inc.
Page 23
Data Sheet, Rev. 3
)
June 2001

Outline Diagrams

64-Pin TQFP

Dimensions are in millimeters. .
12.00 ± 0.20
10.00 ± 0.20
PIN #1 IDENTIFIER ZONE
64 49
FW803 PHY IEEE 1394A
Three-Cable Transceiver/Arbiter Device
1.00 REF
0.25
GAGE PLANE
1
16
0.50 TYP
17 32
DETAIL A
DETAIL B
0.05/0.15
48
10.00
± 0.20
33
1.40 ± 0.05
1.60 MAX
12.00
± 0.20
SEATING PLANE
0.08
SEATING PLANE
0.19/0.27
DETAIL A
DETAIL B
0.45/0.75
0.106/0.200
0.08
M
5-3080 (F

Ordering Information

Device Code Package Comcode
FW803-09-DB 64-Pin TQFP 108697079
Agere Systems Inc. 23
Page 24
For additional information, contact your Agere Systems Account Manager or the following: INTERNET: http://www.agere.com E-MAIL: docmaster@micro.lucent.com N. AMERICA: Agere Systems Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106)
ASIA PACIFIC: Agere Systems Singapore Pte. Ltd., 77 Science Park Drive, #03-18 Cintech III, Singapore 118256
Tel. (65) 778 8833, FAX (65) 777 7495
CHINA: Agere Systems (Shanghai) Co., Ltd., 33/F Jin Mao Tower, 88 Century Boulevard Pudong, Shanghai 200121 PRC
Tel. (86) 21 50471212, FAX (86) 21 50472266
JAPAN: Agere Systems Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141, Japan
Tel. (81) 3 5421 1600, FAX (81) 3 5421 1700
EUROPE: Data Requests: DATALINE: Tel. (44) 7000 582 368, FAX (44) 1189 328 148
Technical Inquiries: GERMANY: (49) 89 95086 0 (Munich), UNITED KINGDOM: (44) 1344 865 900 (Ascot),
FRANCE: (33) 1 40 83 68 00 (Paris), SWEDEN: (46) 8 594 607 00 (Stockholm), FINLAND: (358) 9 3507670 (Helsinki), ITALY: (39) 02 6608131 (Milan), SPAIN: (34) 1 807 1441 (Madrid)
Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
Copyright © 2001 Agere Systems Inc. All Rights Reserved Printed in U.S.A.
June 2001 DS99-302CMPR-3 (DS99-302CMPR-2)
Loading...