www.clare.com
CPC1943G
R1
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Operating Voltage Range V
T
- 20 - 240 V
RMS
Peak Blocking Voltage - V
DRM
- - 400 V
Load Current (Continuous) V
L
=120-240VAC IL 0.005 - 0.5 A
Off State Leakage Current V
DRM
I
LEAK
-- 1mA
On-State Voltage Drop - - - 1.2 V
RMS
Critical Rate of Rise - dv/dt 500 - - V/µS
Switching Speeds
Turn-on I
F
=5 mA T
ON
- - 0.5 cycles
Turn-off I
F
=5 mA T
OFF
- - 0.5 cycles
Zero-Cross Turn-On Voltage 1st half cycle - 2 5 V
Sub. half cycle - - 1 V
Operating Frequency1 - 20 - 500 Hz
Load Power Factor for
Guaranteed Turn-On2 - PF 0.25 - - -
Input Characteristics @ 25°C
Input Control Current
For Normal Environment - I
F
5- 50mA
For High Noise Environment - I
F
10 - 100 mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Input Drop-out Voltage - 0.8 - - V
Reverse Input Current VR=5V I
R
--10uA
Common Characteristics @ 25°C
Input to Output Capacitance - C
I/O
-3 -PF
Input to Output Isolation - V
I/O
3750 - - V
RMS
1
Zero Cross 1st half cycle @ <100Hz
2
Snubber circuits may be required at low power factors.
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Package Dissipation
PM - - 8002mW
Isolation Voltage
Input to Output 3750 - - V
RMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Surface Mount Package - - +220 °C
(10 Seconds Max.)
1
Derate Linearly 1.33 mW/˚C
2
Derate Linearly 6.67 mW/˚C