DS1 SERIES
OUT LED on receiver (RX)
The yellow LED ON indicates the presence of the object into controlled area.
POWER ON LED on receiver (RX)
The green LED ON indicates the optimal device functioning.
The fast blinking of the green LED indicates a critical device alignment.
Please refer to “DIAGNOSTICS” paragraph for other indications.
POWER ON LED on emitter (TX)
The green LED ON indicates the correct device functioning.
Please refer to “DIAGNOSTICS” paragraph for other indications.
General information on device positioning
Align the two receiver (RX) and emitter (TX) units, verifying that their distance is inside
the device operating distance, in a parallel manner, placing the sensitive sides one in
front of the other, with the connectors oriented on the same side. The critical alignment
of the unit will be signalled by the fast blinking of the green receiver LED.
Mount the receiver and emitter units on rigid supports which are not subject to strong
vibrations, using specific fixing brackets and /or the holes present on the device lids.
Precautions to respect when choosing and installing the device
Choose the device according to the minimum object to detect and the maximum
controlled area requested (= operating distance x controlled height);
In agroindustrial applications, the compatibility of light grid housing material and any
chemical agents used in the production process has to be verified with the assistance
of the DATALOGIC technical sales support department;
The AREAscan
the safety control of the machines where installed.
Moreover the following points have to be considered:
- avoid installation near very intense and / or blinking light sources, in particular near to
the receiver unit;
- the presence of strong electromagnetic disturbances can condition the correct
functioning of the device; this condition has to be carefully evaluated and checked with
the DATALOGIC technical sales support department;
- the presence of smoke, fog and suspended dust in the working environment can
reduce the operating distance of the device;
- strong and frequent temperature variations, with very low peak temperatures, can
generate a thin condensation layer on the optics surfaces, compromising the correct
functioning of the device;
- reflecting surfaces near the luminous beam of the AREAscan
or lateral) can cause passive reflections able to compromise object detection inside the
controlled area.
if different devices have to be installed in adjacent areas, the emitter of one unit must not
interfere with the receiver of the other unit.
General information relative to object detection and measurement
For a correct object detection and / or measurement, the object has to pass completely
through the controlled area; testing the correct detection before beginning the process is
suggested.
INSTRUCTION MANUAL
CONTROLS
INSTALLATION MODES
TM
light grids are NOT safety devices, and so MUST NOT be used in
TM
device (above, under
CONNECTIONS
EMITTER
(TX):
M12
4-pole connector
NOT USED
0 V
1
2
4
3
1 – brown: +24 Vdc
+24 Vdc
SYNC ( RX)
ANALOGUE
OUTPUT
RECEIVER
(RX):
M12
5-pole connector
5
+24 Vdc
1
SYNC ( TX)
4
SWITCHING
OUTPUT
2
3
0 V
1 – brown: +24 Vdc
2 – white: Analogue output 2 – white: Not used
3 – blue: 0 V 3 – blue: 0 V
4 –black: Switching output 4 – black: SYNC
5 – grey: SYNC
Shielded cables are not foreseen in the standard connection
Ground connection of the two units is not necessary
Use the same power supply for both units: for a correct functioning it’s necessary that
both units TX and RX have the same voltage reference 0V
FUNCTIONING AND PERFORMANCES
The beam interruption due to the passage of an object inside the controlled area caused
the closing of the switching output and the variation of the device analogue output signal.
Small objects can be detected (reaching dimensions of only 5 mm) and determine linear
measurements with a 3 mm error in best cases.
In particular, the switching output is always activated when at least one beam is
obscured. The status variation is signalled by the yellow receiver LED that turns on.
The analogue output value (0-10 V) is proportional to the number of obscured beams (0V
means that no beam is interrupted, 10V all beams interrupted)
The device does not require calibration; periodical checks of the resolution and / or
measurement are however suggested.
The blinking of the green receiver LED (stability function) signals the critical alignment of
the units and / or the functioning outside or near the maximum operating distance. In
optimal conditions the LED remains on continuously.
The two units are synchronised via cable (SYNC wire); precarious connections or
induced disturbances on the synchronism line can cause device malfunctioning or a
temporary blocking.
The diagrams, given below, show the typical minimum resolution trend of each model, SR
(standard resolution) and HR (high resolution), in according to the operating distance (D).
For DS1-LD-SR-XXX-PV, the minimum resolution at a particular operating distance is to
be intended with the trimmer calibrated near commutation threshold for that distance.
11
10
9
8
7
6
5
4
3
Resolution minimum (R) mm
2
0
0
30
15
DS1-SD-HR-XXX-JV
0
700
50
DS1-SD-SR-XXX-JV
900
1300
1100
7
1
1500
Operating distance (D) mm
00
00
9
2
1
DS1-LD-SR-XXX-JV
DS1-LD-SR-XXX-PV
DS1-LD-HR-XXX-JV
00
00
00
5
3
1
2
2
0
90
70
2
2
0
3
100
3
300
DS1- HD-SR-XXX -JV
00
9
3
3700
3500
EMISSION POWER REGULATION (only DS1-LD-SR-XXX-PV)
The emitter is equiped with a trimmer which let
user change the emission power. The operating
distance increases rotating the trimmer clockwise.
The emission power reduction it is useful to
decrease passive reflections when the maximum
operating distance it is not required. Trimmer
rotation is limited to 260°. Do not apply a torque
Rotate the trimmer clockwise to the limit (maximum emission), then align RX and TX at
the required operating distance (LED OUT off); decrease emission power rotating the
trimmer counterclockwise until the output switches (LED OUT off) or the limit is reached
(minimum emission); in the first case, rotate the trimmer clockwise until the output
switches again and LED OUT remains off.
greater than 35 Nmm.
Power supply:
Consumption on emitting
unit
(TX):
Consumption on receiving
unit (RX):
Switching output:
Switching output current:
Output saturation voltage:
Analogue output:
Analogue output current:
Minimum resolution:
Measurement precision:
Response time:
Indicators:
Operating temperature:
Storage temperature:
Operating distance
(typical values):
Emission type:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
RECEIVING UNIT (RX):
Segnal Status Cause Action
OUT LED
POWER ON
LED
EMITTING UNIT (TX):
Segnal Status Cause Action
POWER ON
LED
ON
OFF
ON
Fast blinking
Slow blinking
OFF
ON
Blinking
OFF
TECHNICAL DATA
24 Vdc 15%
150 mA max.
50 mA max without load
1 PNP output
100 mA; short-circuit protection
1.5 V at T=25 °C
0-10V proportional to obscured beams
10 mA max. (1K minimum resistive load)
refer to “Specifications” table
± 3.5 mm (refer to “Specifications” table)
1 ms (refer to “Specifications” table)
RX: OUT LED (yellow) / POWER ON LED (green)
TX: POWER ON LED (green)
0…+ 50 °C
-25…+ 70 °C
DS1-SD-XX-XXX-JV: 0.15…0.8 m
DS1-LD-XX-XXX-JV: 0.15…2.1 m
DS1-LD-SR-XXX-PV: 0.20…2.5 m
DS1-HD-XX-XXX-JV: 0.20…4.0 m
Infrared (880 nm)
0.5 mm amplitude, 10 … 55 Hz frequency, for
every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-
27)
Black electro-painted aluminium
PMMA
IP65 (EN 60529)
M12 4-pole connector for TX
M12 5-pole connector for RX
300 g. (DS1-xx-010-xx)
400 g. (DS1-xx-015-xx)
600 g. (DS1-xx-030-xx)
DIAGNOSTICS
Switching output.
Presence of the object in
the controlled area.
Switching output.
Controlled area free of
objects.
Optimal functioning
Critical alignment of the
unit or/and functioning
closed to maximum
operating distance.
Wrong connections
and/or malfunctioning.
Device is not powered. - Verify the connections.
Normal functioning of
emission unit.
Unit malfunctioning - Switch OFF and switch ON the
Absence of powering
and/or synchronism with
receiver
- Verify the output connections
and any short- circuits
- Switch OFF and switch ON the
device.
- If condition persists, contact
Datalogic.
- If condition persists, contact
Datalogic.
device.
- If condition persists, contact
Datalogic.
- Verify the connections and right
value of power supply.
- If condition persists, contact
Datalogic.
DIMENSIONS
22
DS1-010
DS1-015
DS1-030
L1
150.1
200.1
350.1
Ø4.5 N°2
M2 N°4
43.2
L2 L3
107
157
307
129.1
179.1
329.1
L3
15.5
mm
M12
10.8
24L2
L1
FIXING BRACKET
The fixing bracket is supplied with the product.
SPECIFICATIONS
Controlled
Model
DS1-LD-HR-010-JV 100 32 5 0.31
DS1-LD-HR-015-JV 150 48 5 0.21
DS1-LD-SR-010-JV 100 16 7 0.63
DS1-LD-SR-010-PV 100 16 7 0.63
DS1-LD-SR-015-JV 150 24 7 0.42
DS1-LD-SR-015-PV 150 24 7 0.42
DS1-LD-SR-030-JV 300 48 7 0.21
DS1-LD-SR-030-PV 300 48 7 0.21
DS1-SD-SR-010-JV 100 16 7 0.63
DS1-SD-SR-015-JV 150 24 7 0.42
DS1-SD-SR-030-JV 300 48 7 0.21
DS1-SD-HR-010-JV 100 32 4 0.31
DS1-SD-HR-015-JV 150 48 4 0.21
DS1-HD-SR-010-JV 100 16 7 0.63
DS1-HD-SR-015-JV 150 24 7 0.42
DS1-HD-SR-030-JV 300 48 7 0.21
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2009 - 2017 Datalogic S.p.A. and/or its affiliates
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
height
(mm)
N°.
beams
Minimum
resolution
(mm)
826003144 Rev.E
Output
(V)
Measurement
precision
(mm)
3.5
3.5
7
7
7
7
7
7
7
6
7
3
3
7
7
7
analogue
sensitivity
ALL RIGHTS RESERVED. Without limiting the
Response
Operatine
distance
time
(ms)
2 0.15…2.1
2.75 0.15…2.1
1 0.15…2.1
1 0.20…2.5
1.5 0.15…2.1
1.5 0.20…2.5
2.75 0.15…2.1
2.75 0.20…2.5
1 0.15…0.8
1.5 0.15…0.8
2.75 0.15…0.8
2 0.15…0.8
2.75 0.15…0.8
1 0.20…4
1.5 0.20…4
2.75 0.20…4
(m)