Danfoss TTE4.6FK Data sheet

TTE4.6FK Energy-optimized Compressor R134a 115V 60Hz
General
Code number 102G3448
Approvals UL984
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 14
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (257)
Cooling requirements
Frequency Hz 50 60
Application
90°F S
100°F S
110°F S
Remarks on application:
Motor
Motor type RSCR
LRA (rated after 4 sec. UL984), HST | LST A 9.5
Cut in Current, HST | LST A 18.0
Resistance, main | start winding (77°F) 3.7 5.4
Design
Displacement cu.in 0.28
Oil quantity (type) .oz. 6.1 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 60.6
Weight without electrical equipment lbs. 16.5
Dimensions
Height inch A 6.81
Suction connector location, I.D. in. | angle C 0.252-0.259 | 30°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.202-0.205 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 6.65
B1
B2
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.C3.22 / 520N1364 1/2
ASHRAE LBP Static cooling, with RC 15μF, 115V 60Hz, PTC consumption incl., preliminary data
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 219 488 866
Power cons. in W 72 105 142
Current cons. in A 0.62 0.92 1.24
EER in BTU/Wh 3.05 4.65 6.24
EN 12900 Household (CECOMAF) Static cooling, with RC 15μF, 115V 60Hz, PTC consumption incl., preliminary data
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 52 117 212
Power cons. in W 72 105 142
Current cons. in A 0.62 0.92 1.24
COP in W/W 0.72 1.11 1.49
Accessories for TTE4.6FK Figure Code number Test conditions
PTC starting device (Siemens)
with reduced loss of energy J506-A120-A320 Ambient temp. 90°F 90°F
Cover b 117U1026 Suction gas temp. 90°F 90°F
Run capacitor 15 μF (compulsory) e 117-7118 Liquid temperature 90°F 131°F
Protector (Texas Instuments) f
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.C3.22 / 520N1364 June 2012
a1
117U6106 Condensing temp. 130°F 131°F
117U3302
TI-4TM314NFBYY-53 Mounting accessories Code number
Bolt joint for one comp. Ø: 5/8 in. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
ASHRAE
LBP
EN 12900/
CECOMAF
Loading...