Danfoss TT2.5F Standard Data sheet

TT2.5F Standard Compressor R134a 115V 60Hz
General
Code number 102G3248
Approvals UL984
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °F -13 to 23
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (257)
Cooling requirements
Frequency Hz 50 60
Application
90°F S
100°F S
110°F S
Remarks on application:
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.1
Cut in Current, HST | LST A 14.0
Resistance, main | start winding (77°F) 8.1 4.9
Design
Displacement cu.in 0.16
Oil quantity (type) .oz. 6.1 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 54.2
Weight without electrical equipment lbs. 14.7
Dimensions
Height inch A 6.22
Suction connector location, I.D. in. | angle C 0.252-0.259 | 30°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.189-0.193 | 28°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 5.98
B1
B2
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.Q7.22 / 520N1363 1/2
ASHRAE MBP 115V, 60Hz, static cooling, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 166 187 268 373 445 496
Power cons. in W 66 69 81 93 95 107
Current cons. in A 0.96 0.99 1.04 1.11 1.13 1.22
EER in BTU/Wh 2.54 2.69 3.31 3.99 4.69 4.64
EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling, PTC consumption incl.
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 44 50 71 98 105 132
Power cons. in W 66 69 81 93 95 107
Current cons. in A 0.96 0.99 1.04 1.11 1.13 1.22
COP in W/W 0.68 0.72 0.88 1.05 1.11 1.23
Accessories for TT2.5F Figure Code number Test conditions
PTC starting device (Texas Instuments)
with reduced loss of energy TI 8EA 4B3 Ambient temp. 90°F 90°F
PTC starting device (Siemens)
with reduced loss of energy J506-A120-A120 Liquid temperature 115°F 131°F
Cover b 117U1026
Protector (Texas Instuments) f
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.Q7.22 / 520N1363 June 2012
a1
a1
(alt.)
117U6102 Condensing temp. 130°F 131°F
117U6105 Suction gas temp. 90°F 90°F
117U3301 Mounting accessories Code number
TI-4TM276NFBYY-53 Bolt joint for one comp. Ø: 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/ 8 in . 118-1918
Snap-on in quantities Ø: 5 /8 i n. 118-1919
ASHRAE
MBP
EN 12900/
CECOMAF
Loading...