Danfoss TS710 User guide

User Guide
TS710
Single Channel Heating Timer
www.heating.danfoss.com
User Guide TS710 Single Channel Heating Timer
Symbols
Mon–Sun
AM PM
Function description
Current set day Time and date setup
Current on/o period
Schedule setup
Current set time / parameter setup
Symbols
2 Buttons
Symbols Function description
Schedule setup (menu access*)
Conrm settings
OK
(date and time setup*)
Menu navigation / day selection
Time and setting changes
< >
/ channel mode selection
Channel selection
CH
(holiday mode selection*)
* To access additional feature p ress and hold button for 3 secs
3 Set Date & Time
Function description
Heating active
Heating channel 1 current mode
Away mode
• Press and hold OK button for 3 seconds; Yr ashes. Press < or > buttons to adjust year
• Press OK button again; Mth ashes. Press < or > buttons to adjust month
• Press OK button again; Day ashes. Press < or > buttons to adjust day of the month
• Press OK button again; Hr ashes. Press < or > buttons to adjust hour
• Press OK button again; Min ashes. Press < or > buttons to adjust minute
• Press OK button to exit, automatic exit after 20 seconds if no buttons pressed
Danfoss Heating
2
VUSUG102 05/2019
User Guide TS710 Single Channel Heating Timer
4 Timer Schedule Setup
• Press button to access schedule setup
• Set CH ashes, press OK to conrm
Example below for 5/2 day setup, 2 periods
Mo. Tu. We. Th. Fr. ashing Press OK to accept or right arrow to select Sa. Su.
Sa. Su. Now showing in display.
Period 1:
1. Use < or > to select ON hour, press OK to conrm
2. Use < or > to select ON minute, press OK to conrm
3. Use < or > to select OFF hour, press OK to conrm
4. Use < or > to select OFF minute, press OK to conrm
Repeat 1 to 4 above for period 2
Where TS710 is set for 7day schedule, option will be given to select each day separately. In 24hr mode, option will only be given to select Mo. to Su. together. See parameter P1.
Where TS710 is set for 3 periods, options will be given to select period 3 times. In 1 period mode, option will only be given for one time period. See parameter P2.
A default program provides timer control if the user does not create own programs:
5/2 or 7 day – 3 Periods selected
Days Event 1 - On Event 2 - O Event 3 - On Event 4 - O Event 5 - On Event 6 - O
Start time Start time Start time Start time Start time Start time
Mon - Fri 6:30 8:30 11: 30 13:30 16:30 22:30
Sat - Sun 7:30 9:30 11: 30 13:30 16:30 22:30
* Floor temperatu re control mode .
For 24hr mode, default schedule follows Mo. to Fr. times above.
For 2 periods setup, default event times 1, 2, 5 & 6 are used. For 1 period setup, default event times 1 & 6 are used.
Note: if parameter P1 or P2 are changed schedule wil l default to times above and user selec ted times will need to be reset.
Period 1
1. Use < or > to select ON hour, press OK to conrm
2. Use < or > to select ON minute, press OK to conrm
3. Use < or > to select OFF hour, press OK to conrm
4. Use < or > to select OFF minute, press OK to conrm
Display returns to home screen and schedule is set.
Danfoss Heating
VUSUG102 05/2019
3
User Guide TS710 Single Channel Heating Timer
5 Select Away Mode
• Press CH for 3 seconds to enter Away mode and will be displayed.
• Press CH again to exit Away mode.
6 Set Control Parameters
Press button for 6 seconds to enter the parameter setting mode. Press for parameter selection and set the parameter range via < or >. Complete all adjustments. To exit parameter setup press , automatic exit after 20 seconds in no button is pressed.
No. Parameter settings Settings range Default
P1 Working mode
P2 Schedule periods
P4 Timer display
P5 Auto daylight saving
P7 Service due setup Installer setting only
P8 Reset
01: Schedule timer 7 day 02: Schedule timer 5/2 day 03: Schedule timer 24hr
01: 1 period (2 events) 02: 2 periods (4 events) 03: 3 periods (6 events)
01: 24hr 02: 12hr
01: On 02: O
00: Reset o 01: Select reset
02
02
01
01
00
Danfoss Heating
VUSUG102 | BC306936675289EN-000101 05/2019