Danfoss MK18 Data sheet

Datasheet
MK18 Range - Electronic Time Control Range with Service Interval
Features
The MK18 range has all the exibility and reliability of its predecessor but with a more elegant look and some handy new features. The addition of a real time clock means that setting the time and manually adjusting for summer winter time changes is a thing of the past.
All units in the MK18 range are set to operate straight from the box with default settings, but the inclusion of a full range of customisable user and installer settings provide ultimate exibility when setting up the unit.
The MK18 range consists of 3 products:
TS715 Si / TS715Si-CB Electronic Timeswitch - A single channel unit, with voltage free switching contacts. Ideal for combi-boiler installations and anywhere you require low voltage switching.
CP715 Si Common Timebase Programmer - A two channel programmer providing heating and hot water outputs. Each output can operate independently of the other, with common timing for both channels.
FP715 Si Full Programmer - A two channel programmer providing heating and hot water outputs. Each output can operate independently of the other, with separate timing for each channel.
All three models use an industry standard 6 pin backplate making the MK18 range an ideal replacement for many existing products.
• 24 hours / 5-2 day / 7 day programming
• Factory Set Clock
• Automatic Summer/Winter Time Change
• Backlit Display
• Built in programmes
• Holiday function
• Industry standard wallplate
• Optional Service Interval Timer
Service Interval Timer
The service interval timer allows the installer to select a service due date for the boiler, this can be set at between 28 days and 366 days from the current date.
Service due date is within 28 days
From 28 days prior to the service due date, a visual warning will appear in the display and a buzzer will sound for ten seconds each hour commencing at midday, this can be cancelled for the current day by pressing any button.
Option Service Interval Timer Function
Setting 0 Disabled, (factory default) Setting 1 Active, visual and audible warning, no heat reduction Setting 2 Active, visual and audible warning, heat reduced to 45 minutes per hour Setting 3 Active, visual and audible warning, heat reduced to 30 minutes per hour Setting 4 Active, visual and audible warning, heat reduced to 15 minutes per hour
© Danfoss HS | 732v04 03/2017 | VDBRB412
Service due date is reached or passed
When the service due date is reached the visual and audible warning are repeated each hour of the day commencing at midday, but the duration of the alarm is increased to 60 seconds, this can be cancelled for the current day by pressing any button. All override and programming buttons are disabled and depending upon service interval timer setting, heating can be restricted to 15, 30 or 45 minutes in each programmed hour.
1
Electronic Time Controls with Optional Service IntervalDatasheet
DHW
HTG
DHW
HTG
Specications
Features TS715 Si TS715 Si-CB CP715 Si FP715 Si
Code No. 087N789900 087N790700 087N789700 087N789800
Single channel timeswitch
Two channel programmer, with common timebase
Two channel full programmer, with independent timebase
Service interval timer available, select at time of installation
7 day, 24 hour or 5/2 day operation, select at installation
2 on/os or 3 on/os per day, select at installation
Pumped or gravity hot water option, select at installation
Permanent back lit display
Output channels single independent HW independent HW & CH
Programmes selectable On/O/Auto/Allday
Programmable holiday function Up to 99 days
Factory set real time clock
Automatic BST/GMT change
Service interval timer Programmable 56-365 days
Factory pre-set on/o time
Advance override per channel
+1hour override per channel
Voltage rating 230 Vac ± 15%, 50/60 Hz
Contact Rating 3 (1) A
Switching action
Battery backup on power failure Time and all other settings - indenitely
Maximum ambient temperature 45°C
Enclosure Rating IP30
Dimensions (mm) 137 wide x 93 high x 29 deep
Please note: (1) Per channel on CP and FP models
1 x SPDT
(voltage free)
(commons linked internally)
(1)
2 x SPDT
Installer Settings and DIL Switches
The MK18 programmer and timeswitch family all use APM (Advanced Programming Menu) functionality to provide easy customistation of parameters allowing full exibility of programming.
The units come from the factory set up for most typical installations, but through an Installer APM and separate user APM the units can be adapted to suit almost any application requirement.
The DIL switches on the rear of the unit provide simple and quick selection of 24 hour / 5-2 day or full 7 day control as well as selecting gravity or fully pumped system conguration (CP/FP715Si only)
Sw.1
Sw.2
Sw.3
Sw.4
Not Used
Gravity
5/2 Day
7 Day
Not Used
Pumped
7 Day or 24 Hour
24 Hour
Wiring
ELECTRONICS
L 1 2 3 4
N
COM
TS715 Si
OFF
N/C
N/O
ON
ELECTRONICS
N
FUSED 3A
230V
1
L
DHW COM
2
DHW
SI
TS715 Si-CB
4
HTG COM
53
HTG OFF
6
HTG
ON
ELECTRONICS
MAINS OFF
N/O
N/C
N
L1234
CP715 Si and FP715 Si
OFF
N/C
N/O
ON
ON
Danfoss Ltd.
Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2
© Danfoss HS | 732v04 02/2016 | VDBRB412
Loading...