3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763
) 559-0108
DIMENSIONS
Unit Specification
MCX106
Hall Effect Level Sensor
ISSUE: 1 DATE: November 1995
Dimensions of the MCX106 in Millimeters (Inches).
FEATURES
• Non-contact sensor withstands high shock and vibration
• Input voltage adapted for microprocessor circuits
• Infinite resolution
• Long life
TECHNICAL DATA
ELECTRICAL
INPUT VOLTAGE
5.0 to 8.0 Vdc
HALL EFFECT ELECTROMAGNETIC SENSOR
Life is not limited by the number of cycles
MAXIMUM OUTPUT LOAD CURRENT
1 mA sourcing or sinking
MAXIMUM CURRENT DRAW
20 mA
OUTPUT IMPEDANCE
0
182A
• Designed to withstand the mobile environment
- -40° to 85° C operating range
- 95% relative humidity
- Meets off-highway vibration standards
- Protected against static discharge, EMI and RFI
HYSTERESIS
Negligible
LINEARITY
Approximately ±3% over the rated angle. Since the
output is proportional to the sine of the input angle,
greater linearity can be achieved by reducing the angle
employed.
TEMPERATURE RATING
-40° to 85° C (-40° to 185° F) operating
-55° to 125° C (-67 to 257° F) storage
TEMPERATURE STABILITY
Null shift of ±.028% per °C from -40° to 85° C
Gain shift of ±.025% per °C from -40° to 85° C
K20279 UNIT SPEC
1 OF 1
©Copyright 1995, Sauer-Danfoss (US) Company.
All rights reserved. Contents subject to change.