Danfoss MCX106 Installation guide

Danfoss MCX106 Installation guide

Unit Specification

MCX106

Hall Effect Level Sensor

3500 Annapolis Lane North, Minneapolis, MN 55447

 

Telephone: (763) 509-2084 Telefax: (763) 559-0108 ISSUE: 1

DATE: November 1995

DIMENSIONS

182A

Dimensions of the MCX106 in Millimeters (Inches).

FEATURES

Non-contact sensor withstands high shock and vibration

Designed to withstand the mobile environment

 

 

 

-

-40° to 85° C operating range

Input voltage adapted for microprocessor circuits

 

-

95% relative humidity

 

 

 

-

Meets off-highway vibration standards

Infinite resolution

 

-

Protected against static discharge, EMI and RFI

Long life

TECHNICAL DATA

ELECTRICAL

INPUT VOLTAGE 5.0 to 8.0 Vdc

HALL EFFECT ELECTROMAGNETIC SENSOR Life is not limited by the number of cycles

MAXIMUM OUTPUT LOAD CURRENT 1 mA sourcing or sinking

MAXIMUM CURRENT DRAW 20 mA

OUTPUT IMPEDANCE 0

HYSTERESIS

Negligible

LINEARITY

Approximately ±3% over the rated angle. Since the output is proportional to the sine of the input angle, greater linearity can be achieved by reducing the angle employed.

TEMPERATURE RATING

-40° to 85° C (-40° to 185° F) operating -55° to 125° C (-67 to 257° F) storage

TEMPERATURE STABILITY

Null shift of ±.028% per °C from -40° to 85° C Gain shift of ±.025% per °C from -40° to 85° C

K20279 UNIT SPEC

1 OF 1

©Copyright 1995, Sauer-Danfoss (US) Company. All rights reserved. Contents subject to change.