Danfoss MCW100A, MCW100 B Installation guide

0 (0)

MCW100A, B

Time Proportional

Rotary Position Controller

BLN-95-8966-4

Issued: March 1992

DESCRIPTION

The MCW100 Time Proportional Rotary Position Controller provides auto matic grade or steering control of paving, trenching and curbing machines by switching an on/off solenoid valve. The Controller uses a wand follower to sense the grade level or steering command from a stringline or surface.

Two modules are housed in the case of the Controller. The grade sensing module electromagnetically measures the deviation between the true grade ofthemachinethroughthefollower.Theamplifiermodulereceivesthesignal

from the sensor module and produces a voltage output to drive solenoid valves which, on a typical paving machine, operate lift cylinders. Within the amplifier’s proportional band, the percent of time the output is on is proportional to the grade error.

The MCW100A and B are the same with three exceptions: First, the “A” unit is switched on the hot side while the “B” unit is switched on the ground side. Secondthe“A”hasaninternalgrade/slopeswitchthat the“B”doesnothave.

Third, on the “A” model the deadband adjustment is a multiple turn potentiometer and on the “B” model it is a single turn trim potentiometer.

FEATURES

May be mounted on either side of machine

• Dual UP/DOWN lamps show deviation from setpoint in

Adjustable tracking force

RUN and STANDBY modes

• Reverse polarity and short circuit protected

Rugged aluminum housing

• Moisture and corrosion resistant

• Adjustable deadband varies sensitivity

• Withstands vibration and shock

RUN/STANDBY switch permits operator to switch to

• Models for both 12 and 24 Volt systems

 

manual control

ORDERING INFORMATION

SPECIFY

1.Model Number MCW100A or B

2.Voltage, 12 or 24 Vdc

3.Cable Part Number

4.Follower Part Number(s)

TABLE A.

 

ORDER NUMBER

VOLTAGE

TYPE OF OUTPUT

 

MCW100A1025

12 Vdc

Hot Side Switching

 

MCW100A1033

24 Vdc

Hot Side Switching

 

 

 

 

 

MCW100B1008

12 Vdc

Ground Side Switching

 

MCW100B1016

24 Vdc

Ground Side Switching

ACCESSORIES

1.STEERING FOLLOWER

Straight tubular follower, 16 inches long overall with breakaway joint. For steering only. Part Number KG07002.

2.RIGHT ANGLE GRADE FOLLOWER

With breakaway joint. For grade applications only. Follows a stringline. Also used with skate assembly, or skate and ski assembly for following hard reference surface. Part Number KG04003.

3.RIGHT ANGLE GRADE FOLLOWER LESS SENSING ARM For grade applications utilizing the skate and/or skate and ski assemblies. Same as Part Number KG04003 above,butwithoutthesensingarmandbreakawayjoint.

Part Number K09274.

© Danfoss, 2013-09

BLN-95-8966-4

1

Danfoss MCW100A, MCW100 B Installation guide

ORDERING INFORMATION (continued)

4.SKATE ASSEMBLY

For grade applications. Use with right angle grade follower(PartNumberK09274)onhardreferencesurface. Part Number KG06001.

5.SKI ASSEMBLY

For grade applications. Used with right angle grade follower (Part Number K09274), and skate assembly (PartNumberKG06001)onhardreferencesurface.Part Number KG02001.

6.CABLE ASSEMBLY

KW01015 two-foot coiled cable that extends to ten feet (3 meters). Has right angle connector on one end, and straightconnectorontheotherendtomakeconnections

between the MCW100 and Bendix Type No. MS3102A18-1P plug. (Part Number K03989.)

BLOCK DIAGRAM: High Side Switching

Microsyn

 

F

 

Voltage regulator

 

 

 

 

 

 

V

+

 

-

t

 

Battery

 

 

V

440Hz

f

 

 

 

t

V

3Hz

 

 

t

+

- +

V

V

t

Gain potentiometer

V

t

1605

DIMENSIONS

Approximate Dimensions of the MCW100 in Millimeters (Inches).

1149

BLN-95-8966-4

2

Loading...