Danfoss MCW100A, MCW100 B Installation guide

MCW100A, B
Time Proportional Rotary Position Controller
BLN-95-8966-4 Issued: March 1992
DESCRIPTION
The MCW100 Time Proportional Rotary Position Controller provides auto­matic grade or steering control of paving, trenching and curbing machines by switching an on/off solenoid valve. The Controller uses a wand follower to sense the grade level or steering command from a stringline or surface.
Two modules are housed in the case of the Controller. The grade sensing module electromagnetically measures the deviation between the true grade of the machine through the follower. The amplifier module receives the signal from the sensor module and produces a voltage output to drive solenoid valves which, on a typical paving machine, operate lift cylinders. Within the amplifier’s proportional band, the percent of time the output is on is propor­tional to the grade error.
The MCW100A and B are the same with three exceptions: First, the “A” unit is switched on the hot side while the “B” unit is switched on the ground side. Second the “A” has an internal grade/slope switch that the “B” does not have. Third, on the “A” model the deadband adjustment is a multiple turn trim potentiometer and on the “B” model it is a single turn trim potentiometer.
FEATURES
• May be mounted on either side of machine
• Adjustable tracking force
• Rugged aluminum housing
• Adjustable deadband varies sensitivity
• RUN/STANDBY switch permits operator to switch to manual control
ORDERING INFORMATION
SPECIFY
1. Model Number MCW100A or B
2. Voltage, 12 or 24 Vdc
3. Cable Part Number
4. Follower Part Number(s)
TABLE A.
ORDER NUMBER VOLTAGE TYPE OF OUTPUT
MCW100A1025 12 Vdc Hot Side Switching
MCW100A1033 24 Vdc Hot Side Switching
MCW100B1008 12 Vdc Ground Side Switching
MCW100B1016 24 Vdc Ground Side Switching
• Dual UP/DOWN lamps show deviation from setpoint in RUN and STANDBY modes
• Reverse polarity and short circuit protected
• Moisture and corrosion resistant
• Withstands vibration and shock
• Models for both 12 and 24 Volt systems
ACCESSORIES
1.
STEERING FOLLOWER Straight tubular follower, 16 inches long overall with breakaway joint. For steering only. Part Number KG07002.
2.
RIGHT ANGLE GRADE FOLLOWER With breakaway joint. For grade applications only. Fol­lows a stringline. Also used with skate assembly, or skate and ski assembly for following hard reference surface. Part Number KG04003.
RIGHT ANGLE GRADE FOLLOWER LESS SENSING ARM
3.
For grade applications utilizing the skate and/or skate and ski assemblies. Same as Part Number KG04003 above, but without the sensing arm and breakaway joint. Part Number K09274.
© Danfoss, 2013-09 BLN-95-8966-4 1
ORDERING INFORMATION
(continued)
4. SKATE ASSEMBLY For grade applications. Use with right angle grade fol­lower (Part Number K09274) on hard reference surface. Part Number KG06001.
5. SKI ASSEMBLY For grade applications. Used with right angle grade follower (Part Number K09274), and skate assembly (Part Number KG06001) on hard reference surface. Part Number KG02001.
BLOCK DIAGRAM: High Side Switching
Microsyn
V
440Hz
t
6. CABLE ASSEMBLY KW01015 two-foot coiled cable that extends to ten feet (3 meters). Has right angle connector on one end, and straight connector on the other end to make connections between the MCW100 and Bendix Type No. MS3102A18-1P plug. (Part Number K03989.)
V
3Hz
+
-
+
f
V
t
V
t
Gain
potentiometer
F
+
Battery
DIMENSIONS
Voltage regulator
V
-
t
V
t
1605
BLN-95-8966-4
Approximate Dimensions of the MCW100 in Millimeters (Inches).
2
1149
Loading...