Danfoss MCI 25 B Installation guide [da]

INSTRUCTIONS
MCI 25 B
Montering - Mounting - Montage mm (inch)
047C0421
DK Hvis enhed er monteret vandret reducer strøm med 50% UK
If unit is mounted horizontally derate current by 50%
D Falls Einheit horizontal montiert wird, reduziert sich der Strom
um 50%.
Forbindelse - Wiring - Verdrahtung
75° C
K
abel / wire *
**
**
**
- Vigtigt: (Overhold max. skruedrejningsmomenter)
- Important: (Observe the maximum screw torque limits)
- Wichtig: (Max. Drehmoment beachten)
* Used copper conductoronly ** UL tested
mm2 (AWG) mm2 (AWG)
2 x 1.5 - 6 (2 x 16 - 10)
2 x 1.5 - 6 2 x 16 - 10)
1 - 10 (18 - 8)
2 x 1 - 6 (2 x 18 - 10)
0.5 - 1.5 (20 - 16)
2 x 0.5 - 0.75 (2 x 20 - 18)
0.5 - 1.5 (20 - 16)
2 x 0.5 - 1.5 (2 x 20 - 16
0.5 - 1.5 (20 - 16)
2 x 0.5 - 1.5 (2 x 20 - 16)
Pozidrive 2
1.2 Nm max.
10.6 lb-in max.
6 mm
1.2 Nm max.
10.6 lb-in max.
N.A.
3 mm
0.5 Nm max.
4.4 lb-in max.
Mål - Dimensions - Abmessungen mm
DK Køleplade skal holdes ren. Luftstrøm må ikke blokeres UK Keep heat sink clean. Airfl ow should not be blocked D Kühlfl ächen freihalten. Luftstrom muß ungehindert fl ießen
Motor Danfoss
A
0.63 - 1.00 047B3024
Use UL listed magnetic circuit breaker or UL specifi ed back-up fuse type K5 or H class
NB:
1.00 - 1.63 047B3025
1.6 - 2.5 047B3026
2.5 - 4.0 047B3027
4.0 - 6.3 047B3028 6 - 10 047B3029 10 - 16 047B3030 16 - 20 047B3031 20 - 25 047B3032
Run / break command Slo
w speed command
Forced brake command
Bypass
I-O mechanical brake
Common
(inch)
CTI 25
DK Hvis beskyttet med sikringer, se specifi kationer i datablad UK If pretection with fuses, see recommendations in data sheet D Falls Sicherungen verwendet werden, Empfehlungen im Datenblatt beachten PS: This product has been designed for class A equipment. Use of the product in domestic environment may cause radio interference, in which case the user may be required to employ additional mitigation methods.
047C0421
UL: Use thermal overload protection as required by the National Electric Code UL: When protected by a non-time delay K5 or H Class fuse, rated 266% of motor FLA, this device is rated for use on a circuit capable of delivering not more than 5,000 rms. symmetrical amperes, 600 V maximum. Maximum surrounding temperature 40°C
© Danfoss | DCS (rja) | 2015-09
IC.PI.C50.J2.51
520B6903
Indstilling - Settings - Einstellungen
Dansk English Deutsch
Advarsel!
Indstil Brake torque til 1 før tilslutning af drifts pæn ding. Ved større motorer kan for høj indstilling medføre komponentskader.
Caution!
Adjust Brake torque to 1 before mains is connected. For larger motors a too high brake current can lead to component damages
Warnung!
Brake torque auf 1 einstellen, befor Anschluß an Betriebsspannung. Bei größeren Motoren kann eine zu hohe Einstellung Schäden an den Kom po nen ten verursachen.
NB!
Initial moment Initial torque Startleistung
Initial moment m. kick-start Initial torque with kick-start Startleistung m. Kick-Start
Rampe op Ramp up Anlaufzeit
• Anvend 2 mm x 0.5 mm skruetrækker
• Vær forsigtig ikke at indstille drejekontak-
terne imellem klik.
• Softstarteren afl æser indstillinger i st tilstand
Dansk English Deutsch
1. Indstil Ramp-up kontakt til max.
2. Indstil Brake torque kontakt til 1
3. Indstil Initial torque kontakt til min.
4. Påtryk styrespænding i et par sekun­ der, hvis ikke motor akslen roterer øjeblikkelig efter start juster Initial torque en deling op.
Gentag indtil motor aksel roterer øjeblikkelig efter start.
Hvis Initial torque justeringen ikke er tilstrækkeligt til at starte motoren er det nødvendigt at anvende Kick-start.
1. Indstil Initial torque til minimum kick­ start moment.
2.Påtryk styr
Indstil Ramp-up tiden til den ønskede værdi
e spænding i et par sekunder. Hvis belastningen stopper umiddelbart efter Kick-start perioden juster Initial torque en deling op. Gentag indtil motor aksel fortsætter med at rotere efter Kick-start
perioden.
op
· Use 2 mm x 0.5 mm screwdriver. Make sure that the switches click into
· position, otherwise time and torque settings will not be correct.
· The motor controller will read settings in
the off state.
1. Set Ramp-up switch to maximum
2. Set Brake torque switch to 1
3. Set Initial torque switch to inimum
4. Apply control signal for a few seconds. If the load does not rotate immediately increase the torque one step and try again. Repeat until the load starts to rotate immediately on start up.
If the maximum Initial torque setting is not suffi cient to start the motor, it is necessary to use kick start.
1.Set Initial torque switch to minimum kick start torque
2.Apply control signal for a few seconds. If the load stops right after the kick start increase the Initial torque onestep and try again. Repeat until the load continues to rotate after the “kick”.
Adjust the Ramp-up time to the desired starting time
Initial
· 2 mm x 0.5 mm Schraubenzieher verwenden
· Schalter müssen einrasten, um korrekte Funktion zu gewährleisten.
· Eingestellte Werte werden im ausgeschalteten Zustand abgelesen.
1. Ramp-up Schalter auf max. stellen.
2. Brake torque Schalter auf 1 stellen.
3. Initial torque Schalter auf min. stellen
4. Steuersignal einige Sekunden betätigen. Falls der Motor nicht sofor anläuft, Initial torque schrittweise erhöhen, bis der Motor anläuft.
Falls Initial torque max. Einstellung nicht ausreicht um den Motor zu starten, muß Kick-start verwendet werden.
1. Initial torque Schalter auf min.
Kick-start einstellen.
2. Steuersignal einige Sekunden
betätigen. Falls der Motor sofort wieder stoppt, Initial torque schrittweise erhöhen, bis der Motor sofort nach dem "Kick" anläuft.
Ramp-up auf den gewünschten Wert einstellen.
t
Bremse moment Brake torque Bremsleistung
Funktionsvælger Operating mode selector Funktionsschalter
2
Juster Brake torque indtil den ønskede bremsetid opnås.
NB. Hvis bremse moment indstillingen er for lav eller for høj vil den automatiske stop detektering ikke fungere.
Indstil langsom hastighed og hjælpe­kontakt (13 - 14) funktion: I. 7,5% af nom. hastighed og “bremse
motor” kontakt funktion
II.10% af nom. hastighed og “bremse
motor” kontakt funktion
III. 7,5% af nom. hastighed og “start-
stop” kontakt funktion
IV. 10% af nom. hastighed og “start-stop”
kontakt funktion
© Danfoss | DCS (rja) | 2015-09 IC.PI.C50.J2.51
Adjust the Brake torque until the desired stop time is obtained.
NB Note that if the braking torque setting is too high or too low the automatic stop detection will not function.
Select the desired slow speed value and auxiliary contact (13 - 14) function: I. 7.5% of nom. speed and “mechanical
brake” contact function
II.10% of nom. speed and “mechanical
brake” contact function
III. 7.5% of nom. speed and “start-stop”
contact function
IV. 10% of nom. speed and “start-stop”
contact function
Brake torque einstellen, bis die gewünschte Bremszeit erreicht ist.
NB. Falls die Einstellung der Brems­leistung zu niedrig oder zu hoch ist, wird der automatische Stop nicht funktionieren.
Kriechgeschwindigkeit und Hilfsfunktionsschalter (13 - 14) einstellen: I. 7.5% der Nenngeschwindigkeit und
“Bremsmotor” Funktionsschalter
II.10% der Nenngeschwindigkeit und
“Bremsmotor” Funktionsschalter
III. 7.5% der Nenngeschwindigkeit und
“Start-Stop” Funktionsschalter
IV. 10% der Nenngeschwindigkeit und
“Start-Stop” Funktionsschalter