Service guide
Changing motor flange
APP / APP S / APP S 674 53-86
hpp.danfoss.com
Service guide | Changing motor flange APP / APP S / APP S 674 53-86
Table of Contents
1. Introduction
Contents
1. Introduction ....................................................................................................................................................................... 2
2. Disassemble motor flange ............................................................................................................................................ 3
3. Assembly motor flange .................................................................................................................................................. 5
4. Exploded view ................................................................................................................................................................... 7
This document covers the instructions for changing motor flange on the axial piston pumps APP
/ APP S / APP S 674 53-86.
Important: Place the pump horizontally on
a pallet or other stable surface above the
ground. Ensure that the pump cannot roll.
Tools provided with toolset 180Z0665:
• 1 x cone bushing extractor
• 1 x M8 x 140 screw
• 3 x M8 x 70 screws with nuts
• 3 x valve plate fixation
• 2 x M6 x 65
• 2 x tool washer
• 1 x M16 pin and nut
• 1 x ø30/17 x 3 washer
• 1 x shaft seal press bush tool
• 1 x bracket
• 1 x 8 mm Allen key
• 1 x 6 mm Allen key
For a better understanding of the pump, please
see the exploded view in section 4.
• 1 x M8 x 40 with nut
• 2 x combination wrench 13mm
• 1 x combination wrench 24 mm
• 1 x combination wrench 30 mm
• 1 x 24 mm socket (½”)
• 1 x torque wrench (½”)
• 1 x valve plate tool
• 2 x screw drivers, 5.5 x 1mm
• 1 x NV24 flush valve tool
• 2 x M8 x 16 bolts
• 1 x valve plate mount
2 | © Danfoss | DCS (im) | 2017.11
180R9403 | 521B1470 | DKCFN.PI.013.1I.02
Service guide | Changing motor flange APP / APP S / APP S 674 53-86
2. Disassemble motor
flange
1. Remove the coupling and shaft key (if
your pump model is an APP S / APP S
674 there are no shaft key. The shaft has a
spline instead).
3. If necessary, replace the O-ring.
2. Remove the 4 M6 screws from the cover
for shaft seal. Use 2 M6 screws to extract
the cover mounting them into the threads
in the cover for shaft seal.
4. Replace 3 screws with the 3 M8x70 screws
so they are equally separated from each
other. Torque the screws slightly and
fasten the nuts until they make contact
with the motor flange. Remove the
remaining screws.
© Danfoss | DCS (im) | 2017.11
5. Install guide screw in the top. Loosen the
three nuts sequentially one round at a
time, so the end flange comes out
as straight forward as possible.
Use two combination wrenches so you do
not unscrew the screws while loosening
the nuts.
6. Slide the motor flange out, using the
guide pin to protect the shaft seal. Make
sure the guide pin in the housing remains
in place.
180R9403 | 521B1470 | DKCFN.PI.013.1I.02 | 3