Danfoss APP 21–46 Installation guide

Instruction
Instruction
APP pump instruction
APP pumps
APP 21–46
APP 21-43
hpp.danfoss.com
ro-solutions.com
Table of Contents
Table of Contents
1. Identication ...........................................................................2
2. System design ..........................................................................3
2.1 Open-ended systems with direct water supply...........................................3
2.2 Preferred RO system design and P&ID ...................................................3
2.3 Reversible pumps .......................................................................4
2.4 General comments......................................................................4
3. Building up the pump unit ..............................................................4
3.1 Mounting...............................................................................4
3.2 Direction of rotation ....................................................................5
3.3 Orientation .............................................................................5
3.4 Protection from too high pressures ......................................................5
3.5 Grounding ..............................................................................5
3.6 Connections ............................................................................6
4. Initial start-up ...........................................................................7
5. Operation...............................................................................7
5.1 Temperature............................................................................7
5.2 Pressure ................................................................................8
5.3 Dry running.............................................................................8
5.4 Disconnection ..........................................................................8
5.5 Storage .................................................................................8
6. Service..................................................................................8
6.1 Warranty................................................................................8
6.2 Maintenance............................................................................8
6.3 Repair ..................................................................................8
1. Identication
PUMP
Type APP 38 Code no. 180BXXXX
Serial no. XXXXXXXX-XXX
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
2
180R9405 | AN274337709031en-000302 | 11.2019
2. System design
The design of the system must ensure that self-emptying of the pump during standstill is avoided.
The inlet pressure of the pump must never exceed the outlet pressure. This may typically occur in boosted or open-ended systems with direct water supply.
2.1 Open-ended systems with direct water supply
The pump is supplied with water directly from a feed pump.
The inlet pressure for APP 21-38 must be at least 2 barg (29 psig) and 3.5 barg (50.8 psig) for the APP 46, depending on speed. It must not exceed 5 barg (72.5 psig) continuous.
To protect the pump from being damaged by peaks of high-pressure in case the pump stops momentarily, it is required to mount a low­pressure relief valve on the inlet line.
2.2 Preferred RO system design and P&ID
1. Dimension the inlet line to obtain mini­mum pressure loss (large ow, minimum pipe length, minimum number of bends/ connections, and ttings with small pressure losses).
2. Place an inlet lter (1) in front of the APP pump (2). Please consult Danfoss lter data sheet for guidance on how to select the right lter. Thoroughly clean pipes and ush system prior to start-up.
3. Place a monitoring pressure switch (3) set at min. inlet pressure between lter and pump inlet. The monitoring switch must stop the pump at pressures lower than minimum pressure.
4. Use exible hoses (4) to minimize vibrations and noise.
5. In order to eliminate the risk of damage and cavitation, a positive pressure at the inlet (5) is always to be maintained at min. inlet pressure and max. inlet pressure.
Inlet
Outlet
It is recommend to install safety valve or a pressure relief valve (9) in order to avoid high-pressure peaks in case the pump stops momentarilly or is spinning backwards.
6. For easy system bleeding and ushing, a bypass non-return valve (6) is integrated in the APP pump.
7. A non-return valve (7) in outlet can be installed in order to avoid backspin of the pump. The volume of water in the mem­brane vessel works as an accumulator and will send ow backwards in case of the pump stops momentarily.
8. A safety valve or a pressure relief valve (8) can be installed in order to avoid system damage as the Danfoss APP pump creates pressure and ow immediately after start­up, regardless of any counter pressure.
Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between non-return valve and pump as protection against high-pressure peaks.
Media filter
PI
Feed
180R9405 | AN274337709031en-000302 | 11.2019
1
PI
1
PI PI
Fresh water
permeat flush
9 3
5
M
PT
2
7
4
6
PI
Brine
Permeate
PI
3
3-5 mm [0.12-0.20 inch]
2.3 Reversible pumps
If exposed to high-pressure in the outlet while the electric motor is not energized, the pumps will start spinning backwards. This will not harm the pumps as long as the pressure in the inlet does not exceed the max. pressure peak of 10 barg(145 psig).
If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required as protection against high-pressure pulses and high-pressure in general.
Alternatively a high-pressure check valve can be mounted in the pump discharge line to prevent the pump from reversing.
The dotted setup ensures that the inlet pressure does not exceed 10 barg (145 psig), when a non­return valve is mounted in the inlet.
In order to avoid the risk of cavitation, the inlet pressure for APP 21-38 must be min. 2 barg (29 psig) and 3.5 barg (50.8 psig) for APP 46, depending on speed. The inlet line connection must be properly tightened, as possible entrance of air will cause cavitation.
2.4 General comments
Filtration
A good ltration is vital to ensure a long and trouble-free life of the pump.
As water has very low viscosity, the APP pumps have been designed with very narrow clearance in order to control internal leakage rates and improve component performance. Therefore it is important that the inlet water is ltered properly to minimize the wear of the pump.
The main lter must have a ltration eciency of
99.98% at 10 μm. We recommend to use precision depth lter cartridges rated 10 μm abs. β10 ≥ 5000 (equivalent to a ltration eciency of
99.98%). Bag lters and string wounded lter cartridges typically have only 50% ltration eciency. This means that for each 100,000 parti­cles reaching the lter, 50,000 particles pass through it compared to only 20 particles in a lter with an eciency of 99.98%.
For more information on the importance of proper ltration, please consult our publication “Filtration” (code number 521B1009), which also will provide you with an explanation of ltration denitions and a guidance on how to select the right lter.
Monitoring
It is recommended to continuously monitor the following conditions:
Filter clogging
Pressure (inlet- and outlet side of the pump)
3. Building up the pump unit
D
A: Elastic coupling B: Bell housing C: Motor shaft D: Pump ange
3.1 Mounting
1. Mount the coupling ush or maximum 1 mm oset from the pump shaft end. Ensure an air gap between coupling parts of 3-5 mm (0.12-0.2 inch).
2. Mount the bell housing on pump. Secure nuts with the right torque.
3. Measure the longest distance “A” from top of bell housing to the button of coupling claw.
4. Mount the coupling on motor shaft. Ensure the coupling and motor ange are not in contact with each other.
5. Measure from motor ange to the top of the coupling. That measurement “B” shall be 3-5 mm (0.12-0.2 inch) shorter than the measurement “A”.
(“A” and “B” can be found on the next
page).
4
180R9405 | AN274337709031en-000302 | 11.2019
6. Adjust respectively, verify the measure­ment, and secure both couplings with the right torques on the locking screws (see coupling operation & mounting instruction).
7. Mount the elastic gear ring and mount the bell housing/pump on the motor. After mounting it must be possible to move the elastic gear ring 3-5 mm (0.12 - 0.2 inch) axial “C”. The check can be done through the inspection hole of bell housing. Secure ange bolts with the right torque.
1: Bolts: torque 100 Nm ±10 Nm 2: Nuts: torque 40 Nm ±4 Nm 3: Torque see table below
1
3
2
2
C
1
If alternative mounting is desired, please contact Danfoss High Pressure Pumps.
Choose proper tolerances to ensure an easy mounting of the elastic coupling without use of tools.
Please take care to observe the recommended length tolerances of the chosen coupling, as an axial force on the pump will damage the pump.
(“C” can be found on the drawing below).
Thread size
Torque (Nm)
3.2 Direction of rotation
Is indicated by an arrow on the pump label.
PUMP
Type APP 38 Code no. 180BXXXX
Serial no. XXXXXXXX-XXX
3.3 Orientation
The pump can be mounted/orientated in any horizontal direction with the inlet and the outlet pointing upwards, downwards or to either side.
3.4 Protection from too high pressures
The pump should be protected against too high pressure by means of a safety valve or a pressure relief valve.
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
M5 M6 M8 M10
2 4.8 10 17
The valve should be placed as close to the pump as possible.
The opening characteristics of the valve must not result in peak pressures higher than 100 barg (1450 psig).
We recommend the use of exible soft hoses both in the inlet and in the outlet lines.
3.5 Grounding
To prevent stray current corrosion we recom­mend grounding of the pump and all other parts in the system. All parts in the system must be electrical potential equalized to a single reference point (grounding point). It is recom­mended that the electrical resistance in the grounding cable is equal to or below 0.25 Ω toards the grounding point.
180R9405 | AN274337709031en-000302 | 11.2019
5
The valve outlet must not be connected directly to the pump suction line. It must be connected directly to the drain.
Inlet
3.6 Connections
I: Inlet O: Outlet C: Bleeding D: Parallel key
Outlet
Inlet
Outlet
C
I
O
C
C
D
Description APP 21 - APP 46
E Parallel key,
DIN 6885
F Bleeding G ¼”, Hexagon AF = 6 mm
I Inlet port M60 x 1.5; depth 24 mm
O Outlet port M60 x 1.5; depth 24 mm
Mounting ange ISO 3019-2 180B4TW
mm 12 × 8 × 70
in 0.47 × 0.31 × 2.76
For more details on the accessories, please contact Danfoss High Pressure Pumps. Possible extension see next page.
6
180R9405 | AN274337709031en-000302 | 11.2019
C
Accessories Typ e Code no.
3” inlet hose kit 3” Victaulic 180Z0144 2.00 m [79”]
2” outlet hose kit APP 21-38
2½” outlet hose kit APP 46
2½” inlet connector APP 21-24
3” inlet connector APP 21-46
Non-return valve (outlet) Super Duplex APP 21-46
2½” Victaulic 180Z0263 1.78 m [70”]
2½”Victaulic 180Z0618 1.00 m [39.4”]
2½” Victaulic 180B3206
3” Victaulic 180B3208
2½” Victaulic
(OD 73 mm)
180Z0280 1.00 m [39.4”]
180Z0619 1.78 m [70”]
180H0055
4. Initial start-up
5. Operation 5.1 Temperature
1. Flush inlet line before connecting the pump, to remove possible impurities from pipes, hoses etc.
2. Connect pump inlet to inlet line and ush the pump for 5 min. by means of the internal ushing valve, to remove possible impurities from pipes, hoses etc.
3. Loosen top bleeding plug “C” (see item 3.5) using an allen key (only plugs with internal hexagan sockets). Retighten the plug, when water appears from the bleeding plug.
4. Make sure that the direction of rotation of the electric motor corresponds to the direc­tion of rotation of the pump (see label on pump).
5. Now the pump is ready for start-up.
WARNING Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of the pump (see label on pump). Otherwise the pump will be damaged if a check valve is placed between pump and feed pump.
O
I
Internal ushing valve
Fluid temperature: Min. +2°C to max. +50°C (Min. +35.6°F to max. +122°F)
Ambient temperature: Min. +2°C to max. +50°C (Min. +35.6°F to max. +122°F)
In case of lower operating temperatures, please contact Danfoss High Pressure Pumps.
NaCl vs. temperature
º
80
C
Duplex
70
60
50
316L
40
30
The chart below illustrates the corrosive resistance of dierent types of stainless steel related to NaCl concentration and temperature.
The APP water pump is made of Duplex and Super Duplex.
If the water pump is operated above the Super Duplex line, always ush water pump with fresh water at operation stop in order to minimize the risk of crevice corrosion.
Super Duplex
20
100
1000
160 1600
180R9405 | AN274337709031en-000302 | 11.2019
10 000
16000
100 000
160000
CI ppm
NaCI ppm
-
7
5.2 Pressure
The inlet pressure for APP 21-46 must be min. 2 barg (30 psig) and max. 5 barg (72.5 psig). At lower pressures the pump will cavitate, resulting in damage of the pump.
Max. inlet pressure peak (e.g. in case the pump stops momentarily) up to 10 barg (145 psig) are acceptable.
Max. pressure on the pump’s outlet line should be limited at 80 barg (1160 psig) continuously, 70 barg for APP 46.
Note: The pump unit should include a pressure gauge on the high-pressure side.
5.3 Dry running
When running, the pump must always be connected to the water supply in order to avoid damage if it should run dry.
5.4 Disconnection
If the inlet line is disconnected from the water supply, the pump will be emptied of water through the disconnected inlet line.
When starting up again, follow the bleeding procedure described under section 4: Initial start up.
5.5 Storage
monopropylene glycol to prevent internal corrosion or frost in the pump.
For further information on anti-freeze media, please contact Danfoss High Pressure Pumps.
Recommended procedure:
1. Disconnect the water supply to the pump.
2. Through the lower bleeding plug, empty the pump housing of water and close it again.
3. Connect the pump to a tank containing anti-freeze additive. Connect a hose to the inlet port of the pump and via another hose return the ow from the outlet port to the tank with antifreeze additives.
4. Quickly start and stop the pump. Make sure that the pump does not run dry.
The pump is now protected against
internal corrosion and frost.
Storage:
Storage of pump that have been in operation: For shorter periods of storage ush the pump with permeate rotating the pump for 10 sec., empty permeate and store. For long term storage (more than 2 months) Danfoss recommends servicing the product and clean any biological growth of the surface. Store the pump dry without water inside.
6. Service
Storage temperature: Min. -40°C to max. +70°C (Min. -40°F to max. +158°F)
When preparing the pump for long-term storage or for temperatures below the freezing point, ush the pump with an anti-freeze medium type
6.1 Warranty
Danfoss APP pumps are designed for long operation, low maintenance and reduced lifecycle costs.
Provided that the pump has been running according to the Danfoss specications, Danfoss guarantees 8,000 hours service-free operation, however, max 18 months from date of produc­tion.
If Danfoss recommendations concerning system-design are not followed, it will strongly inuence the life of the APP pumps.
6.2 Maintenance
After 8,000 hours of operation, it is strongly recommended to inspect the pump and change
any worn parts, e.g. pistons and shaft seal. This is done in order to prevent a potential breakdown of the pump. If the parts are not replaced, more frequent inspection is recom­mended according to our guidelines.
Standstill:
The APP pumps are made of Duplex/Super Duplex materials with excellent corrosion properties. It is however, always recommended
to ush the pump with fresh water when the system is shut down.
When stopping the pump for more than 1 day ush the pump with permeate by rotating the pump for 10 sec. Flushing through the ushing valve of the pump without rotating the pump is not enough for cleaning the inside of the pump. The pump can be ushed with biocide like the membranes. The biocide must be compatible with the materials used in our pump (materials can be found in the parts list in the Operating guide.
6.3 Repair
In case of irregular function of the APP, please contact Danfoss High Pressure Pumps sales organisation.
8
180R9405 | AN274337709031en-000302 | 11.2019
180R9405 | AN274337709031en-000302 | 11.2019
9
Danfoss A/S High Pressure Pumps Nordborgvej 81 DK-6430 Nordborg Denmark
© Danfoss | DCS (im) | 2019.11
180R9405 | AN274337709031en-000302 | 10