Danfoss APP 21–46 Installation guide

Instruction
Instruction
APP pump instruction
APP pumps
APP 21–46
APP 21-43
hpp.danfoss.com
ro-solutions.com
Table of Contents
Table of Contents
1. Identication ...........................................................................2
2. System design ..........................................................................3
2.1 Open-ended systems with direct water supply...........................................3
2.2 Preferred RO system design and P&ID ...................................................3
2.3 Reversible pumps .......................................................................4
2.4 General comments......................................................................4
3. Building up the pump unit ..............................................................4
3.1 Mounting...............................................................................4
3.2 Direction of rotation ....................................................................5
3.3 Orientation .............................................................................5
3.4 Protection from too high pressures ......................................................5
3.5 Grounding ..............................................................................5
3.6 Connections ............................................................................6
4. Initial start-up ...........................................................................7
5. Operation...............................................................................7
5.1 Temperature............................................................................7
5.2 Pressure ................................................................................8
5.3 Dry running.............................................................................8
5.4 Disconnection ..........................................................................8
5.5 Storage .................................................................................8
6. Service..................................................................................8
6.1 Warranty................................................................................8
6.2 Maintenance............................................................................8
6.3 Repair ..................................................................................8
1. Identication
PUMP
Type APP 38 Code no. 180BXXXX
Serial no. XXXXXXXX-XXX
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
2
180R9405 | AN274337709031en-000302 | 11.2019
2. System design
The design of the system must ensure that self-emptying of the pump during standstill is avoided.
The inlet pressure of the pump must never exceed the outlet pressure. This may typically occur in boosted or open-ended systems with direct water supply.
2.1 Open-ended systems with direct water supply
The pump is supplied with water directly from a feed pump.
The inlet pressure for APP 21-38 must be at least 2 barg (29 psig) and 3.5 barg (50.8 psig) for the APP 46, depending on speed. It must not exceed 5 barg (72.5 psig) continuous.
To protect the pump from being damaged by peaks of high-pressure in case the pump stops momentarily, it is required to mount a low­pressure relief valve on the inlet line.
2.2 Preferred RO system design and P&ID
1. Dimension the inlet line to obtain mini­mum pressure loss (large ow, minimum pipe length, minimum number of bends/ connections, and ttings with small pressure losses).
2. Place an inlet lter (1) in front of the APP pump (2). Please consult Danfoss lter data sheet for guidance on how to select the right lter. Thoroughly clean pipes and ush system prior to start-up.
3. Place a monitoring pressure switch (3) set at min. inlet pressure between lter and pump inlet. The monitoring switch must stop the pump at pressures lower than minimum pressure.
4. Use exible hoses (4) to minimize vibrations and noise.
5. In order to eliminate the risk of damage and cavitation, a positive pressure at the inlet (5) is always to be maintained at min. inlet pressure and max. inlet pressure.
Inlet
Outlet
It is recommend to install safety valve or a pressure relief valve (9) in order to avoid high-pressure peaks in case the pump stops momentarilly or is spinning backwards.
6. For easy system bleeding and ushing, a bypass non-return valve (6) is integrated in the APP pump.
7. A non-return valve (7) in outlet can be installed in order to avoid backspin of the pump. The volume of water in the mem­brane vessel works as an accumulator and will send ow backwards in case of the pump stops momentarily.
8. A safety valve or a pressure relief valve (8) can be installed in order to avoid system damage as the Danfoss APP pump creates pressure and ow immediately after start­up, regardless of any counter pressure.
Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between non-return valve and pump as protection against high-pressure peaks.