Danby DAC5110M, DAC5210M User Manual

Owner’s Use and Care Guide
Guide d’utiliser et soin de Propriètaire
Model • Modèle
DAC 5110M, DAC5210M
Danby Products Ltd, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, Findlay, Ohio USA 45840
V3.11.09 JF
ownership, be sure this manual accompanies the unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente du
climatiseur, ce manuel doit être inclus avec l’appareil.
CAUTION:
Read and follow all safety rules and operating
instructions before first use of this product.
PRÉCAUTION:
Veuillez lire attentivement les consignes de
sécurité et les directives d’utilisation avant
l’utilisation initial de ce produit.
AIR CONDITIONER
Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 8
• Important Safety Information
• Features
• Installation Instructions
• Operating Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
CLIMATISEUR
Guide d’utilisation et soins de Propriètaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 16
• Consignes de Sécurité Importantes
• Caracteristiques
• Consignes d’installation
• Consignes d’operation
• Soins et Entretien
• Dépannage
• Garantie
Thank you for choosing a Danby Room Air Conditioner to cool your home. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.
NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a
Customer Service Representative, call Danby TOLL FREE: 1-800-26- (1-800-263-2629)
WELCOME
CAUTION: Do not leave a room air conditioner unattended in a room where people or animals who cannot react to a failed unit are located. A failed unit can cause extreme overheating and fire in an enclosed, unattended space.
1
READ ALL SAFETY INFORMATION BEFORE USING
1) All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2) Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3) This 115V air conditioner uses 10.0 or less nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.
4) For your safety and protection, this unit is
grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.
5) The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. If it is necessary to use an extension cord to connect your air conditioner, use an
approved “air conditioner” extension cord only
(available at most local hardware stores).
6) The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the power cord.
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
5.0 to 10 18 AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types Rated Volts 120 Amps 10 Wall Outlet
Fuse Size 15 Time Delay Fuse Plug Type
(or Circuit Breaker)
IMPORTANT SAFETY INFORMATION
ELECTRICAL
SPECIFICATIONS
2
Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort
needs and leave at that chosen setting.
2) The filter is very efficient in removing airborne
particles. Keep the air filter clean. Normally, filters should be cleaned every 2 weeks. More frequent cleaning may be necessary depending on indoor air quality.
3) Use drapes, curtains or shades to keep direct
sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow
around the unit.
4) Start your air conditioner before the outdoor air
becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room.
5) When outdoor temperatures are cool enough, use
HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.
ENERGY-
SAVING TIPS
FEATURES
Air FIlter
Exterior Air Inlet
Cabinet
Interior Air Inlet
Control Panel
Interior Air Inlet
3
INSTALLATION INSTRUCTIONS
ELECTRIC SHOCK HAZARD: To avoid the possibility of personal
injury, disconnect power to the unit before installing or servicing.
3/4” screws (9)
3/8” screws (4)
Safety Lock (1)
Adhesive Foam Seal (1)
Frame Lock (2)
Regular Foam
Seal (1)
Side Curtain RH (1)
Side Curtain LH (1)
Fig. 1
INSTALLATION HARDWARE
CAUTION: Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.
L shaped mounting bracket (1)
TOOLS NEEDED FOR INSTALLATION:
Screw Drivers: Phillips and flat head.
Power Drill: 1/8” diameter drill bit.
Pencil
Measuring Tape
Scissors
Carpenters Level
NOTE: Save the shipping carton and packing materials for future storage or transportation. From carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1.
LOCATION
A) This room air conditioner is designed to fit
easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.
B) Make sure window and frame are structurally sound and free from dry and rotted wood.
C) For maximum efficiency, install the air conditioner on a side of the house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.
D) Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit (See Fig. 2). The rear of the unit should be outdoors and
not in a garage nor inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.
E) Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes.
F) DO NOT install unit where leakage of
combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc.
Awning
Fence, wall, or other obstacle
Ground
Side Obstruction
20” Min
30” Min
20” Min
12” Min
Fig. 2
NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrains or neighboring properties.
INSTALLATION INSTRUCTIONS (cont’d)
4
3/8” screws
“L” shaped mounting bracket
“U” shaped Channel (Factory Installed)
Fig. 3
Slide down into tabs
Shutter tabs
Shutter
Shutter frame
Fig. 4
1) Assembly of the Upper Channel to Cabinet.
• “L” Shaped Top Channel: Install the “L” shaped channel to the top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws.
2) Assembly of the Side Curtains to Cabinet.
• Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner, as shown in Fig. 4.
• Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right.
3) Completing the Installation
• Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on.
Loading...
+ 11 hidden pages