CAUTION:

Read and follow all safety rules and operating instructions before first use of this product.

PRECAUTION:

Veuillez lire attentivement les consignes de sécurité et les instructions d’utilisation avant l’utilisation initiale de ce produit.

Model • Modèle DAC10010E / DAC10011E / DAC12010E

Welcome

Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.

For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the side of the unit.

NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.

Model Number:

Serial Number:

Date of Purchase:

WARNING

Improper connection of the grounding plug can result in risk of Fire, Electric Shock and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.

This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer Service Representative, call Danby TOLL FREE: 1-800-263-2629

2

Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ELECTRICAL SPECIFICATIONS

1)All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2)Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3)This 115V air conditioner uses 10.2 or less nameplate amps and may be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.

4)For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.

5)The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. If it is necessary to use an extension cord to connect your air conditioner, use an approved “air conditioner” extension cord only (available at most local hardware stores).

6)The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the power cord.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

8.8 to 10.2

14

AWGAmerican Wire Gauge

*Based on copper wire at 60°C temperature rating.

 

TABLE 2

 

 

 

 

 

 

 

Receptacle and Fuse Types

 

 

 

 

 

 

Rated Volts

125

 

 

 

 

 

 

Amps

15

 

 

 

 

 

 

Wall Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse Size

15

 

 

Time Delay Fuse

Plug Type

(or Circuit Breaker)

 

3

Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ENERGY SAVING TIPS

Features

Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times. (usually cleaned every 2 weeks depending on indoor air quality).

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating the room, but do not allow drapes or curtains to obstruct the air flow around the unit.

4)Start your air conditioner before the outdoor air becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room.

5)When outdoor temperatures are cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.

Fresh Air Ventilation Switch

Cabinet

(open for Fan only operation)

 

Interior Air Outlet

 

Control Panel

Exterior

 

Air Inlet

Interior Air Inlet

 

 

Air FIlter

Installation Instructions

ELECTRIC SHOCK HAZARD

To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

NOTE: Your Room Air Conditioner is designed for easy installtion in a single or double-hung window. This unit is NOT designed for vertical (slider type) windows and/or through-the-wall applications.

TOOLS NEEDED FOR INSTALLATION:

Screw Drivers: Phillips and flat head.

Power Drill: 1/8” (3.2mm) diameter drill bit.

Pencil

Measuring Tape

Scissors

Carpenters Level

NOTE: Save the shipping carton and packing materials for future storage or transportation. From carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1.

CAUTION

Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.

4

Installation Instructions

INSTALLATION

Fig. 1

HARDWARE

 

3/4in. (19.1mm)

Safety Lock (1)

screws (7)

 

3/8in. (9.5mm) screws

“L” Shaped

(4) *Factory installed

mounting

on some models

bracket (1)

 

* Factory installed

 

on some models

 

Sash bracket (2)

Adhesive

 

Foam Seal(1)

 

Side Curtain RH (1)

Side Curtain LH (1)

 

LOCATION

A)This room air conditioner is designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.

B)Make sure window and frame are structurally sound and free from dry and rotted wood.

C)For maximum efficiency, install the air conditioner on a side of the house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.

D)Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit (See Fig. 2). The rear of the unit should be outdoors and not in a garage nor inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.

E)Be certain the proper electrical outlet is within reach of the installation.

Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes.

F)DO NOT install unit where leakage of combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc.

NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrains or neighboring properties.

5

Danby DAC10011, DAC10011E Owner's Manual

Installation Instructions

LOCATION

Fig. 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Awning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12” Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fence,

 

 

 

 

 

 

 

 

 

 

 

 

30”

 

 

 

 

 

 

 

 

 

 

Side

 

 

Min

 

 

 

 

wall, or

 

 

 

 

 

 

Obstruction

 

 

 

 

 

 

other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

obstacle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Assembly of the Upper Channel to Cabinet. (Factory installed on some units)

“L” Shaped Top Channel: Install the “L” shaped channel to the top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws.

2) Assembly of the Side Curtains to Cabinet.

Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner, as shown in Fig. 4.

Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right.

3) Completing the Installation

Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on.

3/8” screws

Fig. 3

“L” shaped mounting bracket

“U” shaped Channel (Factory Installed)

Fig. 4

Slide

down

 

 

into

 

tabs

Shutter tabs

Shutter

Shutter frame

6

Installation Instructions

3) Completing the Installation (cont)

Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5).

Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5).

Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4” screw on each side (Fig. 5).

Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6).

PLEASE NOTE: Window applications come in a variety of different styles.

Therefore, it may be necessary to modify or improvise your particular installation.

Fig. 5

 

 

 

 

 

 

 

Window sash

 

 

 

 

 

 

 

 

 

 

3/4” screws

“L” Shaped

Mounting

Bracket

Shutter clamps

Fig. 6

Safety Lock

Foam Seal

3/4” screw

7

Operating Instructions

KEY PAD FEATURES

 

LED

 

Display

Temp / Timer

 

Control

68

 

 

Auto

 

Timer

Check

Sleep

Mode

Filter

 

Auto

Auto

 

MODE

Mode

Fan

Speed

Selector

 

Energy

Power

Button

Saver

 

LED DISPLAY: Displays the following information independently;Set Temperature, Ambient RoomTemperature and Auto Timer On/Off settings.

POWER: Turns unit On/Off.

MODE: Allows you to scroll through and select the desired operating mode; Cool , Dry , Fan Only and *Auto .The selected mode will be denoted by the adjacent indicator light.*‘Auto’is a pre-set factory program that automatically defines the mode (Cool or Dry) and fan speed based on the set temperature.

FAN SPEED: Select from four different fan settings;Low , Medium , High and Auto during Cool and Fan Only mode. Please note: During ‘Dry’ mode the fan speed is automatically defined .

ENERGY SAVER: Automatically cycles the fan on and off while the compressor is not in use.

TEMP / TIMER CONTROL: Used to increase or decrease

the Temperature setting in 1°C / °F increments, and Auto-Timer On/Off settings in 30min./1hr. increments. Note: This appliance allows you select the temperature scale to be displayed in either “Celsius” or Fahrenheit” according to your preference.To change the temperature scale displayed on the electronic display, press both the “Temp/Timer”adjust arrows simultaneously to alternate between “Celsius” & “Fahrenheit”.

CHECK FILTER: The adjacent indicator light will illuminate as a reminder to clean the air conditioner filter (see page 9) Once the filter has been cleaned and replaced, depress the Check Filter button in order to resume operation.

SLEEP MODE: When activated, the current set temperature is gradually increased over a one (1) hour period then maintained for seven (7) hours. Once the program is complete, the air conditioner will resume to its previous set temperature (before sleep mode was activated). This feature is mean to be used during the night time hours to prevent the room from getting too cold (while you sleep) and results in less compressor running time and reduced energy consumption. Sleep mode may be cancelled by depressing the Sleep Mode button while the program is running.

AUTO-TIMER: Used to initiate the Auto On/ Auto Off timer.

While the Air Conditioner is off (Auto-On):

1)Press the Auto-Timer button once and the adjacent Auto-On indicator light will illuminate.

2)Use the Temp/Timer control cursors to select a delayed On time of up to 24 hours.

3)Select the appropriate mode under which you want the unit to operate (Auto-Cool-Dry-Fan Only)

4)Select the fan speed setting.

5)The time you selected will appear in the LED display.

While the Air Conditioner is on (Auto-Off):

1)Press the Auto-Timer button twice and the adjacent Auto-Off indicator light will illuminate.

2)Use the Temp/Timer control cursors to select a delayed Off time of up to 24 hours.

3)The time you selected will appear in the LED display. The Auto On and Auto Off timer can operate during the same program by defining the Auto-Off parameters immediately after the Auto On parameters.The Auto-Timer may be cancelled at any time by turning the unit On/Off.

8

Operating Instructions

USING THE REMOTE

CONTROL

5m

Location of the remote controller.

Use the remote controller within a distance of 5 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.

REMOTE CONTROLLER SPECIFICATIONS

CAUTION

The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.

Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.

If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.

If other electrical appliances react to the remote controller, either move these appliances or call the service depot.

Model

R15A, R15B, R15C

 

 

Rated Voltage

3.0V(Button cell: CR2025)

 

 

Lowest Voltage of

2.0V

CPU Emitting Signal

 

 

 

Signal Receiving Range

5m

 

 

Environment

-5°C ~ 60°C

 

 

9

Operating Instructions

REMOTE

CONTROLLER

BUTTONS

NOTE: Modle R15B does not have CLEAN AIR feature.

ON/OFF button

Operation starts when this button is pressed and stops when the button is pressed again.

TEMP UP button

Push this button to increase the temperature setting in 1°C increments to 30°C.

FAN button

Used to select the fan speed in three steps:

LOW MED HIGH

CLEAN AIR button (on some models)

When this button is pressed, the ion generator is energized and will help remove pollen and impurities from the air.

ENERGY SAVER button

Press this button to activate the Energy saving mode. Press it again to stop the funtion.

ON/OFF button

Operation starts when this button is pressed and stops when the button is pressed again.

TEMP UP button

Push this button to increase the temperature setting in 1°C increments to 30°C.

FAN button

Used to select the fan speed in three steps:

LOW MED HIGH

SWING button

When this button is pressed, the vertical louvres will swing automatically from side to side. Press it again to deactivate the "SWING" feature.

ON/OFF

 

MODE

TEMP

S

TEMP

UP

DOWN

 

ENERGY

 

 

SAVER

 

FAN

 

TIMER

MODE button

Each time you press this button, a mode is selected in a sequence that goes from AUTO, HEAT (cooling and heating models only) COOL, DRY, FAN and back to AUTO.

TEMP DOWN button

Push this button to decrease the indoor temperature setting in 1°C increments to 17°C.

CLEAN

SLEEP

AIR

 

Models:

R15A

R15B

ON/OFF MODE

TEMP

TEMP

UP

DOWN

 

SWING

FAN

TIMER

 

SLEEP

Models:

R15C

TIMER button

Push this button to activate the “Auto Start” or “Auto Stop” program from 0-12

hours (1 hour increments)

SLEEP button

Press this button to activate the Sleep mode. This function is available on COOL, HEAT or AUTO mode only and maintain the most comfortable temperature for you.

MODE button

Each time you press the button, a mode is selected in a sequence that goes from AUTO, HEAT (cooling and heating models only) COOL, DRY, FAN and back to AUTO.

TEMP DOWN button

Push this button to decrease the indoor temperature setting in 1°C increments to 17°C.

TIMER button

Push this button to activate the “Auto Start” or “Auto Stop” program from 0-12

hours (1 hour increments)

SLEEP button

Press this button to activate the Sleep mode. Press again to stop the function. This function is available on COOL, HEAT or AUTO mode only and maintain the most comfortable temperature for you.