Danby DAC080EUB2GDB Product Manual

Loading...

OWNER’S USE AND CARE GUIDE GUIDE D’UTILISATION ET D'ENTRETIEN

AIR CONDITIONER

CLIMATISEUR

02'(/ 02'Ê/(

DAC080ECB2GDB / DAC080EUB2GDB DAC100ECB2GDB / DAC100EUB2GDB DAC120ECB2GDB / DAC120EUB2GDB

2014.12.05

DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9

DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840

1-800-263-2629 (1-800-26-DANBY)

DO NOT RETURN THIS UNIT TO THE RETAILER

WITHOUT FURTHER INSTRUCTIONS

Dear valued customer, we hope your Danby product purchase fulfills all your requirements. Your satisfaction is our priority!

Please contact us at our toll free consumer service number for any inquiries you may have about your new unit.

NE PAS RETOURNER CET APPAREIL CHEZ LE DÉTAILLANT SANS CONSIGNES SUPPLÉMENTAIRES

Cher(ère) client(e) important(e), nous espérons que votre produit Danby répond à tous vos besoins. Votre satisfaction est notre priorité!

Veuillez nous contacter au numéro gratuit de service après-vente, si vous avez des questions quelconques à propos de votre nouvel appareil.

NO DEVUELVA ESTA UNIDAD A LA TIENDA SIN

INSTRUCCIONES ADICIONALES

Estimado cliente, esperamos que el producto Danby que ha comprado satisfaga completamente sus necesidades. Su satisfacción

es nuestra prioridad!

Por favor, contáctenos gratuitamente a nuestro número de Servicio al Cliente para cualquier pregunta que tenga sobre su nuevo electrodoméstico.

Danby 28.08.2014

TO OBTAIN WARRANTY SERVICE YOU MUST PROVIDE A VALID PROOF OF PURCHASE. PLEASE STAPLE YOUR RECEIPT TO THIS PAGE FOR FUTURE REFERENCE.

_____________________________________________________________________

POUR OBTENIR LE SERVICE SUR GARANTIE, VOUS DEVEZ FOURNIR UNE PREUVE D’ACHAT VALIDE. VEUILLEZ AGRAFER VOTRE REÇU À CETTE PAGE POUR RÉFÉRENCE FUTURE.

_____________________________________________________________________

IMPORTANT - GROUNDING METHOD

This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed. Never use the cord, the plug or the appliance when they show any sign of damage. Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrician or electrical supplier.

IMPORTANT - MÉTHODE POUR LA MISE À LA TERRE

Ce produit arrive d’origine avec un cordon d’alimentation équipé d’une prise à trois fiches. Il doit être branché dans une prise avec une fiche de mise à la terre en conformité avec le Code national de l’électricité et les codes et règles locaux applicables. Si la prise murale n’a pas de mise à la terre, il est de la responsabilité et l’obligation du client de changer la prise existante pour la rendre conforme au Code national de l’électricité et aux codes et règles locaux applicables. La fiche de mise à la terre ne doit pas, en aucune circonstance, être coupée ou retirée. Si vous apercevez des signes de dommage, n’utilisez jamais le cordon d’alimentation, la prise ou l’appareil. N’utilisez jamais l’appareil avec une rallonge sauf si elle a été vérifiée et testée par un électricien qualifié ou un fournisseur de matériel électrique.

CONTENTS

TABLE DES MATIÈRES

AIR CONDITIONER

 

Owner’s Use and Care Guide ................................

1-17

Welcome

Important Safety Information

Features

Installation Instructions

Operation Instructions

Care and Maintenance

Troubleshooting

Warranty

CLIMATISEUR

 

Guide d’utilisation et d’entretien............................

18-34

Bienvenue

Consignes de sécurité importantes

Caractéristiques

Consignes d’installation

Consignes d’utilisation

Soins et entretien

Dépannage

Garantie

CAUTION:

Read and follow all safety rules and operating instructions before first use of this product.

AVERTISSEMENT :

Veuillez lire attentivement les consignes de sécurité et les instructions d’utilisation avant l’utilisation initiale de ce produit.

Model • Modèle

DAC080ECB2GDB / DAC080EUB2GDB / DAC100ECB2GDB DAC100EUB2GDB / DAC120ECB2GDB / DAC120EUB2GDB

WELCOME

Welcome to the Danby family. We are proud of our quality products, and we believe in dependable service, like you will find in this Owner’s Use and Care Guide, and like you will receive from our friendly customer service department. Best of all, you will experience these values each and every time you use your Danby appliance. That is important, because your new appliance will be a part of your family for a long time.

For easy reference, we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturer’s nameplate on the right side of the unit above the powercord.

Note the information below; you will need this information to obtain service under warranty. To receive service, you must provide the original receipt.

NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.

Model No:

Serial No:

Date Purchased:

NEED HELP?

Before you call for service, here are a few things you can do to help us serve you better:

Read this Owner’s Use and Care Guide:

It contains instructions to help you use and maintain your appliance properly.

If you received a damaged appliance:

Immediately contact the retailer (or builder) that sold you the appliance.

Save time and money:

Check the Troubleshooting section at the end of the guide before calling. This section helps you solve common problems that may occur.

If you do need service, you can relax, knowing help is only a phone call away.

1-800-26- (1-800-263-2629)

WARNING

Improper connection of the grounding plug can result in risk of fire, electric shock and/or injury to persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is properly grounded.

1

Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ELECTRICAL SPECIFICATIONS

1.All wiring must comply with local and national electrical codes and must be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2.Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3.This 115V air conditioner uses 9.4 or less nameplate amps and may be used in any properly wired, general-purpose household receptacle. See Table 1 for the specifications for the individual branch circuit.

4.For your safety and protection, this unit is grounded through the powercord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.

5.The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information.

6.The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the powercord.

TABLE 1 DAC080EC/UB2GDB

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

6.2

16

AWGAmerican Wire Gauge

*Based on copper wire at 60°C temperature rating

TABLE 1 DAC100EC/UB2GDB

DAC120EC/UB2GDB

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

7.8 to 9.4

14

AWGAmerican Wire Gauge

*Based on copper wire at 60°C temperature rating

TABLE 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

 

 

 

 

 

 

 

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)

 

 

 

 

 

2

Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ENERGY SAVING TIPS

Your appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.

1.Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2.The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times (usually cleaned every 2 weeks depending on indoor air quality).

3.Use drapes, curtains or shades to keep direct sunlight from penetrating and heating the room, but do not allow drapes or curtains to obstruct the air flow around the unit.

4.Start your air conditioner before the outdoor air becomes hot, to avoid an initial period of discomfort while the unit is cooling the room.

5.When outdoor temperatures are cool enough, use the FAN MODE only, on HIGH, MED., or LOW setting. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than operating on a cooling setting.

FEATURES

*Fresh Air Ventilation Switch (open for Fan only operation, available in some models only)

Interior Air Outlet

Control Panel

Interior Air Inlet

Cabinet

Exterior

Air Inlet

Air Filter

*Pushed in, means the vent is closed. Pulled out, means the vent is open.

3

INSTALLATION INSTRUCTIONS

ELECTRIC SHOCK HAZARD

To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

NOTE: Your Room Air Conditioner is designed for easy installation in a single or double-hung window. This unit is NOTdesigned for vertical (slider type) windows and/or through-the-wall applications.

TOOLS NEEDED FOR INSTALLATION:

Screwdrivers: Phillips and flat head.

Power Drill: 1/8in. (3.2mm) diameter drill bit

Pencil

Measuring Tape

Scissors

Carpenter’s Level

NOTE: Save the shipping carton and packing materials for future storage or transportation. From the carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of the hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1.

CAUTION

Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipulate. Inadequate support on the control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.

INSTALLATION

 

screws (7)

Safety Lock (1)

 

Fig. 1

1/2in. (13 mm)

 

HARDWARE

3/8in. (9.5mm) screws

“L” Shaped

 

 

(4) *Factory installed

mounting

 

 

on some models

bracket (1)

 

 

 

* Factory installed

 

 

 

on some models

 

 

 

Sash bracket (2)

 

 

Adhesive

 

 

 

Foam Seal(1)

 

 

 

Side Curtain RH (1)

 

 

Side Curtain LH (1)

 

 

 

Regular

 

 

 

Foam Seal(1)

 

4

INSTALLATION INSTRUCTIONS

LOCATION

1.This room air conditioner is designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.

2.Make sure window and frame are structurally sound and free from dry and rotted wood.

3.For maximum efficiency, install the air conditioner on a side of the house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.

4.Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit (See Fig. 2). The rear of the unit should be outdoors. It should not be in a garage, or inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30 in. (76 cm) above the floor or ground. Curtains and other objects within the room should be prevented from blocking the air flow.

5.Be certain that the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes.

6.DO NOT install unit where leakage of combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc.

NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrians or neighbouring properties.

NOTE: It is normal for your unit to drip a small amount of water, especially on excessively humid days.

Fig. 2

 

 

 

 

 

 

 

 

 

 

 

20 in.

 

 

 

 

 

Awning

(50.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 in. (30.5

cm) Min

 

 

 

 

 

 

 

 

 

 

20 in.

 

 

 

 

 

 

 

 

 

(50.8

cm)

 

 

 

 

 

Min

 

 

 

 

 

Side

30

in. (76.2 cm)

Fence,

wall, or

 

Min

 

 

Obstruction

 

 

 

 

other

 

 

 

obstacle

 

 

Ground

 

 

 

 

 

 

 

5

Danby DAC080EUB2GDB Product Manual

INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION

1.

Assembly of the upper channel to the cabinet (factory installed on some units).

“L” Shaped Top Channel: install the “L” shaped channel to the top of the cabinet as shown in Fig. 3, using four (4)

 

3/8 in. (9.5 mm) screws.

2.

Assembly of the side curtains to the cabinet.

Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner, as shown in Fig. 4.

Slide the shutters into the top (“L” shaped) and bottom (“U” shaped) channels. The shutters are identified (on frame) as left and right.

Fig. 3

3/8 in. (9.5 mm)

“L” shaped mounting bracket

“U” shaped Channel (Factory Installed)

Fig. 4

Slide

down

 

into

 

tabs

Shutter tabs

Shutter

Shutter frame

3. Completing the installation.

Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on.

Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5).

Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 1/2 in. (13 mm) screw on each side and one in the “L” shaped mounting bracket (Fig. 5).

Secure the shutter clamp on each side of the lower part of the shutter, and secure to window sill using one 1/2 in. (13 mm) screw on each side (Fig. 5).

Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 1/2 in. (13 mm) screw (See Fig. 6).

PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify your particular installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 

 

 

 

 

Window sash

Fig. 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Lock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Foam Seal

 

 

 

 

 

screws

 

 

 

 

 

 

(adhesive)

 

 

 

 

1/2 in. (13mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2 in. (13 mm) screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“L” Shaped

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bracket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutter clamps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION (cont’d)

Check that the air conditioner is tilted downwards to the outside, about 3° to 4°, as shown in Fig. 7. After proper installation, condensed water should not drain from the overflow drain hole during normal use. If you notice water leaking out, check the angle of tilt, and make any necessary adjustments. However, on a very humid day, water leakage can occur – this is normal.

Note: To achieve 3° to 4°, you must measure the H, see figure 7.

Measure the tilt angle from the cabinet’s edge. The distance H should be approximately 3/4 in. to 1 in. (19 mm - 2.5 cm)

for DAC080ECB2GDB and DAC080BUB2GDB. The distance H should be approximately 1 in. to 1 3/8 in. (2.5 cm - 3.5 cm) for DAC100ECB2GDB, DAC100EUB2GDB, DAC120ECB2GDB and DAC120EUB2GDB.

Fig. 7

Measure the tilt angle from the cabinet’s edge

 

: approximately 3/4 in. (19 mm) to

 

1 in. (2.5 cm) for DAC080EB2GDB

 

: approximately 1 in. (2.5 cm) to

 

1 3/8 in. (3.5 cm) forDAC110EB2GDB

 

DAC120EB2GDB

WINDOW

OPERATING INSTRUCTIONS

KEY PAD FEATURES

 

LED

 

Display

Temp / Timer

 

Control

68

 

 

Auto

 

Timer

Check

Sleep

Mode

Filter

 

Auto

Auto

 

MODE

Fan

Mode

 

 

Speed

Selector

 

 

Energy

Power

Button

Saver

 

LED DISPLAY: Displays the following information independently - Set Temperature, Ambient RoomTemperature and Auto Timer On/Off settings.

POWER: Turns unit On/Off.

MODE: Allows you to scroll through and select the desired operating mode: Cool, Dry, Fan Only and *Auto. The selected mode will be denoted by the adjacent indicator light. *Auto mode is a pre-set factory program that automatically defines the mode (Cool or Dry) and fan speed, based

on the set temperature. The unit will automatically launch the Energy Saver function when it is in Cool, Dry, or Auto modes.

FAN SPEED: Select from four different fan settings: Low, Medium, High and Auto during Cool and Fan Only mode. Please note, during Dry mode the fan speed is automatically defined.

7

OPERATING INSTRUCTIONS

KEY PAD FEATURES (cont’d)

ENERGY SAVER: Automatically cycles the fan on and off while the compressor is not in use. This function is available in Cool, Dry, and Auto modes (only Auto-Cool and Auto-Fan modes). The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals,until the room temperature is above the set temperature. At this point, the compressor turns back on and cooling restarts.

TEMP / TIMER CONTROL: Used to increase or decrease the Temperature setting in 1°C / 1°F increments, and Auto-Timer On/Off settings in 30min./1hr. increments. Note: This appliance allows you to select the temperature scale to be displayed in either “Celsius” or “Fahrenheit” according to your preference.To change the temperature scale displayed on the electronic display, press both the “Temp/Timer” adjust arrows simultaneously to alternate between Celsius and Fahrenheit.

CHECK FILTER: The adjacent indicator light will illuminate as a reminder to clean the air conditioner filter (see page 11). Once the filter has been cleaned and replaced, depress the Check Filter button in order to resume operation.

SLEEP MODE: In this mode, the selected temperature will increase (when in cooling mode) by 1°C/2°F one half-hour after Sleep mode has been selected. The temperature will then increase by another 1°C/2°F after an additional half hour. This new temperature will be maintained for 6 hours before returning to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally

programmed. The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again.

AUTO-TIMER: Used to initiate the Auto On/ Auto Off timer.

When the air conditioner is off (Auto-On feature):

1)Press the Auto-Timer button once and the adjacent Auto-On indicator light will illuminate.

2)Use the Temp/Timer control cursors to select a delayed ON time of up to 24 hours.

3)Select the appropriate mode under which you want the unit to operate (Auto-Cool-Dry-Fan Only).

4)Select the fan speed setting.

5)The time you selected will appear in the LED display.

When the air conditioner is on (Auto-Off feature):

1)Press the Auto-Timer button twice and the adjacent Auto-Off indicator light will illuminate.

2)Use the Temp/Timer control cursors to select a delayed OFF time of up to 24 hours.

3)The time you selected will appear in the LED display. The Auto-On and Auto-Off timer features can operate during the same program by defining the Auto-Off parameters immediately after the Auto-On parameters.The Auto-Timer may be cancelled at any time by turning the unit On/Off.

For example, if you want to turn the unit on one hour later, to operate for one hour and then stop, set Auto-On “1” and Auto-Off “2”.

Note: This is a “one-shot” timer. It does not continue to cycle on and off. It will turn the unit on (if set by the user) ONE time. It will turn the unit off (if set by the user) ONE time. If you require the unit to turn on/off again automatically, then you must set the timer again.

8

+ 28 hidden pages