We are confident that you will be happy with your selection because it represents the state of the art in the technology of home climate control.
By following the suggestions contained in this manual, the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs.
DAIKIN EUROPE N.V.
Conformity
This unit complies with European directives:
• Low voltage directive 2014/35/UE • Electro-magnetic compatibility 2014/30/UE;.
Symbols
The following symbols provide the necessary information for correct, safe use of the machine in a rapid, unmistakable
Editorial pictograms
User
- Refers to pages containing instructions or information for the user.
Installer
- Refers to pages containing instructions or information for the installer
Safety pictograms
Generic danger
- Signals that the operation described could cause physical injury if not performed according to the safety rules.
Danger of high voltage
- Signals that the operation described could cause electrocution if not performed according to the safety rules.
way
Service
- Refers to pages containing instructions or information for the installer TECHNICAL CUSTOMER SERVICE.
Danger due to heat
- Signals that the operation described could cause burns if not performed according to the safety rules.
Do Not
- Refers to actions that absolutely must not be performed.
2
General
1.1 General warnings .................................................................. 4
1.2 Fundamental safety rules ............................................................ 4
1.3 Product range .................................................................... 5
1.4 Nominal technical specifications ....................................................... 5
1.5 Overall dimensions ................................................................. 6
Installation
2.1 Positioning the unit ................................................................. 7
2.2 Installation modes .................................................................. 7
2.3 Minimum installation space ........................................................... 7
2.4 Access to the internal components ..................................................... 8
2.5 Removing the side panels ............................................................ 9
2.6 Vertical installation .................................................................9
2.7 Horizontal or ceiling installation ....................................................... 10
2.8 Hydraulic connections .............................................................10
2.9 Condensation discharge ............................................................ 11
2.10 Filling the system ................................................................. 12
2.11 Evacuating air while filling the system ................................................... 12
2.12 Electrical connections .............................................................. 13
2.13 Maintenance ....................................................................13
2.14 Cleaning the outside ............................................................... 13
2.15 Cleaning air suction filter ............................................................ 14
2.16 Energy saving tips ................................................................ 15
EN
Troubleshooting
3.1 Troubleshooting .................................................................. 16
3.2 Table of anomalies and remedies .....................................................16
3
1.1
General warnings
GENERAL
After unpacking, make sure that all the components
are present. If not, contact your installer of your DAIKIN affiliate office.
DAIKIN appliances must be installed by an authorised
installer who, on completion of the work, will release a declaration of conformity to the client in respect of the laws in force and the indications given by DAIKIN in the instructions leaflet supplied together with the appliance.
These appliances have been designed both for
conditioning and/or heating environments and must be destined for this use only and compatibly with their performance characteristics.
DAIKIN EUROPE N.V. accepts no responsibility, either
contractual or extra-contractual, for any damage caused to persons, animals of property as a result of incorrect installation, adjustment or maintenance or improper use.
In case of water leaks, turn the master switch of the
system to "OFF" and close the water taps.
As soon as possible, call the DAIKIN technical service
department or else professionally qualified personnel and do not intervene personally on the appliance.
The imbedded FWXM-series do not have a grill or
covering plate. Provide safety guards and air inlet/outlet grills to prevent accidental contact with the device.
If the room temperature is too low or too high it is
damaging for the health and is also a useless waste of energy.
Avoid prolonged contact with the direct air flow.
Do not leave the room closed for long periods.
Periodically open the windows to ensure a correct change of air.
This instruction leaflet is an integral part of the
appliance and consequently must be kept carefully and must ALWAYS accompany the appliance, even when it is passed to a new owner or user or transferred onto another system. If it is lost or damaged, please contact the local DAIKIN technical service centre.
All repair or maintenance interventions must be
performed by the technical service department or by professionally qualified personnel as foreseen in this booklet. Do not modify or intervene on the appliance as this could create dangerous situations and the manufacturer will not be responsible for any damage caused.
Danger from burns - take care when touching
If the appliance is not used for a long period of time, the
following operations should be performed:
- Turn the master switch of the system to "OFF"
- Close the water taps
- If there is the risk of freezing, make sure that anti-freeze has been added to the system otherwise empty the system.
1.2
Fundamental safety rules
Remember that some fundamental safety rules should
be followed when using a product that uses electricity and water, such as:
The unit can be used by children over the age of
8, and by people with reduced physical, sensory or mental capabilities, or with no experience or necessary knowledge, as long as they are monitored or after they have received instructions on the safe use of the unit and have understood the dangers involved.
Children must not play with the appliance. The cleaning and maintenance that must be
performed by the user should not be carried out by children without supervision.
It is forbidden to touch the appliance with wet hands
or body when barefoot.
It is forbidden to carry out any cleaning before having
disconnected the appliance from the electricity mains supply by turning the system master switch to "OFF".
It is forbidden to modify the safety or adjustment
devices or adjust without authorisation and indications of the manufacturer.
It is forbidden to pull, cut or knot the electrical cables
coming out of the appliance, even if it is disconnected from the mains supply.
4
SIU
GENERAL
It is forbidden to poke objects or anything else through
the inlet or outlet grills.
It is forbidden to open the doors which access the
internal parts of the appliance without first turning the system master switch to "OFF".
It is forbidden to dispose of or leave in the reach of
children the packaging materials which could become a source of danger.
1.3
Product range
There are 2 types of DAIKIN heat pump convectors, FWXV and FWXM, each of which is offered in 3 sizes with different performances and dimensions.
FWXV-series
cooler-convector with metal cabinet.
1.4
Nominal technical specifications
It is forbidden to climb onto the appliance or rest any
object on it.
The external parts of the appliance can reach
temperatures of more than 70°C.
FWXM-series
Embedded cooler-convector without panels.
2 pipes
TECHNICAL DATA (DC) FWXV/FWXM 10AATV3(R) 15AATV3(R) 20AATV3(R)
Heat exchanger water contents FWXV/FWXM Maximum working pressure Maximum water inlet temperature Minimum inlet water temperature Hydraulic fixtures Power supply Maximum current absorbed Maximum power absorbed Weight FWXM Weight FWXV
L 0,8 1,13 1,46 bar 10 10 10 °C 80 80 80 °C 4 4 4 " V/ph/Hz 230/1/50 230/1/50 230/1/50 A 0,16 0,18 0,26 W 17.6 19,8 26,5 kg 12 15 18 kg 20 23 26
Eurokonus 3/4 Eurokonus 3/4 Eurokonus 3/4
EN
5
SIU
135 mm
GENERAL
1.5
Overall dimensions
2 pipes
U.M.
Dimensions
A mm 999 1199 1399
FWXV10AATV3(R) FWXV15AATV3(R) FWXV20AATV3(R)
FWXV
601 mm
A
U.M.
Dimensions
A mm 578 778 978
FWXM10AATV3(R) FWXM15AATV3(R) FWXM20AATV3(R)
FWXM
A
6