Daikin FVXG-K User manual

3P290325-1A M11B010A
DAIKIN OPTIONAL PARTS BKS028A4
Two-dimensional bar code is a code for manufacturing.

Installation Procedure

1. Assembling the installation frame.
1) Fix the floor anchor, side support (R), side support (L), and reinforce plate at the 6 locations using the
A
J K L M
( Bolt (M6 × 16L), Washer (M6), Spring washer (M6) , Nut (M6))
B C D
A
Floor anchor
B
Side support (R)
C
Side support (L)

Accessories

D
Reinforce plate
21112
E
Support plate
1216
F
Support cover
1166
G
Cover
H
Thermal insulation
J
Bolt (M6 × 16L)
K
Washer (M6)
L
Spring washer (M6)
M
Nut (M6)
N
Screw (M4 × 8L)
25

Limitations on Place of Installation

Right back pipingLeft back piping
244537.5
* M10 foundation bolt
43
*Be careful of the installation direction.
C
Side support (L)
M
L
K
K
L
M
D
Reinforce plate
Face the cut surface inside.
B
Side support (R)
J
K
A
Floor anchor
K J
Cross-section diagram
D
Reinforce plate
A
Floor anchor
M
Nut (M6)
L
Spring washer (M6)
K
Washer (M6)
K
Washer (M6)
J
Bolt (M6 × 16L)
150
403
105
* Fixing holes
on the wall
537.5
950
* Maximum width
(for air conditioner installation)
Right bottom pipingLeft bottom piping
105
Right pipingLeft piping
720
(for air conditioner installation)
* Maximum height
406 (liquid pipe)
369 (gas pipe)
unit: mm
* Maximum depth
(for air conditioner installation)
223
233
142 (gas pipe) 157 (liquid pipe)
60
45
2. Fix the installation frame.
2-1) Fix the installation frame at 2 locations on the
floor surface using the M10 foundation bolts. (field supply: M10 foundation bolt)
2-2) Fix the installation frame at 4 locations on the
wall using screws. (field supply: M4 × 25L)
CAUTION
• Be sure to fix the installation frame on the floor surface firmly using M10 foundation bolts.
• Fix the installation frame to a sufficiently strong wall that can bear the heavy load of the unit.
M10 foundation bolts (field supply) (2 locations)
Screws (field supply: M4 × 25L) (4 locations)
M10 nuts (field supply) (2 locations)
3. Preparing for the air conditioner installation.
3-1) Remove the pipe port cover on the bottom right of the air conditioner. 3-2) Set the thermal insulation, and cover the field piping, drain hose, and inter-unit wiring with it.
(Note: The thermal insulation is used only when it is routed under the support cover.)
3-3) Fix the support cover at 8 locations on the installation frame using screws. ( Screw (M4 × 8L))
H
Thermal insulation
H
H F
NF
Cross-section diagram
Pipe port cover
Drain hose
Inter-unit wiring
H
Thermal insulation
Field piping
4. Installing the air conditioner and performing finishing.
4-1) Hook the air conditioner on the mounting plate (supplied with the air conditioner), and fix it at 2 locations on the
installation frame using screws. ( Screw (M4 × 8L))
N
Screw (M4 × 8L) (2 locations)
N
H
Set the thermal insulation according to the locations of the M10 foundation bolts.
N
Screw (M4 × 8L) (8 locations)
F
Support cover
3-4) Fix the support plate (2 pcs.) at 6 locations on the installation frame using screws. ( Screw (M4 × 8L))
E
N
3-5) Fix the mounting plate (supplied with the air conditioner) at 6 locations on the installation frame using screws.
N
( Screw (M4 × 8L))
N
Screw (M4 × 8L) (6 locations)
E
Support plate (After the support cover is installed.)
F
Mounting plate (supplied with the air conditioner)
E
Support plate (After the support cover is installed.)
F
4-2) After connecting the field piping, drain hose, and
G
G
N
Cover
inter-unit wiring, fix the cover at 3 locations on the installation frame using screws. ( Screw (M4 × 8L))
N
Screw (M4 × 8L) (3 locations)
Diagram of finished unit
N
Screw (M4 × 8L) (6 locations)
*In accordance with the direction of
the piping, remove the pipe port cover of the cover on either the
G
left or right.