Daikin FVQ71BV1B, FVQ100BV1B, FVQ125BV1B Installation manuals

INSTALLATION MANUAL
SPLIT SYSTEM Air Conditioners
English
Deutsch
MODELS
(Floor standing type)
FVQ71BV1B FVQ100BV1B FVQ125BV1B
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH. BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L’INSTALLATION. CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR. GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA.
PRIMA DELL’INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI. TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
Français
Español
Italiano
Nederlands
Portugues
Русский
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN­DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO. MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ ОБРАЩЕНИЯ В БУДУЩЕМ.
MONTAJDAN ÖNCE BU TALÝMATLARI DÝKKATLÝ BÝR BÝÇÝMDE OKUYUN. GELECEKTE BAÞVURMAK ÜZERE BU ELKÝTABINI KOLAY ULAÞABÝLECEÐÝNÝZ BÝR YERDE MUHAFAZA EDÝN.
(III)
DAIKIN.TCF.021
KEMA
(II)
DAIKIN.TCF.016
KEMA
(I)
DAIKIN.TCF.004
KEMA
<A>
<B>
2024351-QUA/
EMC02-4565
81728-KRQ/
ECM98-4341
59277-KRQ/
ECM95-4233
<C>
Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome,
Kita-ku, Osaka, 530-8323 Japan
Low Voltage 2006/95/EC
Machinery Safety 98/37/EC
Electromagnetic Compatibility 2004/108/EC
Noboru Murata
Manager Quality Control Department
Sakai, 1st of January 2008
(I) FHY35BJV1, FHY45BJV1, FHY60BJV1, FHY71BJV1, FHY100BJV1, FHY125BJV1, FH35BJV1, FH45BJV1, FH60BJV1
DAIKIN INDUSTRIES, LTD.
(II) FHYP35BV1, FHYP45BV1, FHYP60BV1, FHYP71BV1, FHYP100BV1, FHYP125BV1, FH35BZV1, FH45BZV1, FH60BZV1
FHQ35BVV1B, FHQ50BVV1B, FHQ60BVV1B, FHQ71BVV1B, FHQ100BVV1B, FHQ125BVV1B
(III) FHQ35BUV1B, FHQ50BUV1B, FHQ60BUV1B, FHQ71BUV1B, FHQ100BUV1B, FHQ125BUV1B
FVQ71BV1B, FVQ100BV1B, FVQ125BV1B
FUQ71BUV1B, FUQ100BUV1B, FUQ125BUV1B, FUQ71BVV1B, FUQ100BVV1B, FUQ125BVV1B
FAQ71BUV1B, FAQ100BUV1B, FAQ71BVV1B, FAQ100BVV1B
EN60335-2-40,
3P104327-1E
FVQ71BV1B FVQ100BV1B FVQ125BV1B
SPLIT SYSTEM Air Conditioner Installation manual

CONTENTS

1. SAFETY PRECAUTIONS.....................................................................................1
2. BEFORE INSTALLATION ....................................................................................3
3. SELECTING INSTALLATION SITE......................................................................5
4. INDOOR UNIT INSTALLATION ...........................................................................5
5. REFRIGERANT PIPING WORK...........................................................................6
6. DRAIN PIPING WORK .........................................................................................9
7. SEPARATE INSTALLATION OF THE CONTROL PANEL ................................10
8. ELECTRIC WIRING WORK ...............................................................................12
9. WIRING EXAMPLE ............................................................................................13
10. INSTALLATION OF AIR INTAKE GRILLE .........................................................15
11. FIELD SETTING.................................................................................................16
12. TEST OPERATION ............................................................................................17
13. WIRING DIAGRAM.............................................................................................20

1. SAFETY PRECAUTIONS

Please read these “SAFETY PRECAUTIONS” carefully before installing air conditioning equipment and be sure to install it correctly. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along with the operation manual for future reference. This air conditioner comes under the term “appliances not accessible to the general public”.
Meaning of WARNING and CAUTION notices.
WARNING
CAUTION ........... Failure to observe these instructions properly may result in property damage or
WARNING
• Ask your dealer or qualified personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual. Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit. A foundation of insufficient strength may result in the equipment falling and causing injury.
• Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes. Failure to do so during installation work may result in the unit falling and causing accidents.
• Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this installation manual. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire.
........... Failure to follow these instructions properly may result in personal injury or loss of life.
personal injury, which may be serious depending on the circumstances.
English 1
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the terminal box lid can be securely fastened. Improper positioning of the terminal box lid may result in electric shocks, fire or overheating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage. Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
• Be sure to switch off the unit before touching any electrical parts.
• Do not directly touch refrigerant that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite.
• Be sure to earth the air conditioner. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate piping to prevent condensation. Improper drain piping may result in indoor water leakage and property damage.
• Install the indoor and outdoor units, power cord and connecting wires at least 1 meter away from televisions or radios to prevent picture interference and noise. (Depending on the incoming signal strength, a distance of 1 meter may not be sufficient to eliminate noise.)
• Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps (inverter or rapid start types). Install the indoor unit as far away from fluorescent lamps as possible.
• Do not install the air conditioner in the following locations:
1. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen).
Plastic parts will deteriorate, parts may fall off and water leakage could result.
2. Where corrosive gas, such as sulphurous acid gas, is produced.
Corroding of copper pipes or soldered parts may result in refrigerant leakage.
3. Near machinery emitting electromagnetic radiation.
Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit.
4. Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in the air, or
where volatile flammables such as paint thinner or gasoline are handled. Operating the unit in such conditions may result in fire.
2 English

2. BEFORE INSTALLATION

• The accessories needed for installation must be retained in your custody until the installation work is completed. Do not discard them!
• Decide upon a line of transport.
• When transporting by hanging the unit, use a sling of soft material as shown below.
(1) Horizontal hanging (2) Vertical hanging
Sling
*Be sure that the sling
does not slide in the direction of the arrow.
• When moving the unit at or after opening, do not apply force to plastic parts.
• When selecting installation site, refer to the paper pattern (part of packaging material).
• For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit.
Sling
Apply cloth or corrugated fibreboard so that the air discharge grille and air inlet grille are not damaged
1. ACCESSORIES
Check the following accessories are included with the unit.
Name Bracket for installation
Quantity 1 set 2 pcs. 1 pc. 1 each
(1)
Shape
(Attached to the top
Control
Name
Quantity 1 pc. 1 pc. 5 pcs. 1 pc.
Shape
panel patch
plate
(6) (7) (8) (9)
panel)
Remote
controller lid
Through hole
protecting rubber
(2) (3) (4) For gas pipe
Clamp Installation pattern
Bush Insulation for fitting
(5) For liquid pipe
(Other)
(10) Operation
manual
(11) Installation
manual
(12) Screws
(M5 × 12, 2 pcs.)
(Part of packing material)
2. OPTIONAL ACCESSARIES
When the indoor unit is to be controlled by two remote controllers (refer to “FIELD SETTING”), install
them on an adequate place, referring to the related technical information. (As for the installation procedure, follow the instruction in “Remote controller installation procedure” attached to the remote controller.)
English 3
FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED.
1. Items to be checked after completion of work
Items to be checked If not properly done, what is likely to occur Check Are the indoor and outdoor unit fixed
firmly? Is the gas leak test finished? It may result in insufficient cooling. Is the unit fully insulated? Condensate water may drip. Does drainage flow smoothly? Condensate water may drip. Does the power supply voltage
correspond to that shown on the name plate?
Are wiring and piping correct? Is the unit safely grounded? Dangerous at electric leakage. Is wiring size according to specifications? Is something blocking the air outlet or inlet
of either the indoor or outdoor units? Are refrigerant piping length and
additional refrigerant charge noted down?
The unit may drop, vibrate or make noise.
The unit may malfunction or the components burn out.
The unit may malfunction or the components burn out.
The unit may malfunction or the components burn out.
It may result in insufficient cooling.
The refrigerant charge in the system is not clear.
2. Items to be checked at time of delivery *Also review the “SAFETY PRECAUTIONS”
Items to be checked Check
Did you explain about operations while showing the instruction manual to your customer?
Did you hand the instruction manual over to your customer?
Points for explanation about operations
The items with WARNING and CAUTION marks in the instruction manual are the items pertaining to possibilities for bodily injury and material damage in addition to the general usage of the product. Accordingly, it is necessary that you make a full explanation about the described contents and also ask your customers to read the instruction manual.
3. NOTE TO THE INSTALLER
Be sure to instruct customers how to properly operate the unit (especially operating different functions, and adjusting the temperature) by having them carry out operations themselves while looking at the manual.
4 English

3. SELECTING INSTALLATION SITE

Select an installation site where the following conditions are satisfied after obtaining your customer’s approval.
• Where optimum air distribution can be ensured.
• Where nothing blocks the air inlet and outlet, and where sufficient clearance for maintenance and service can be ensured.
• Where condensate can be properly drained.
• Where the floor is strong enough to bear the indoor unit weight.
• Make sure that the floor is not remarkably tilted.
• Where there is no risk of flammable gas leakage.
• Where piping between indoor and outdoor units is possible within the allowable limit. (Refer to the installation manual for the outdoor unit.)
• Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from televisions and radio receivers. This is to prevent image interference and noise in those electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if 1 meter is kept.)
50mm or more
50mm or more

4. INDOOR UNIT INSTALLATION

As for the parts to be used for installation work, be sure to use the provided accessories and specified parts designated by our company.
Fixing procedure
• Fix the indoor unit by using embedded bolt, etc. to prevent falling down of the vertically-long shaped unit.
1. Detach the air intake grille.
Remove the screws (R & L, total 2) locking the grille stopper. Then, (1) lean the grille forward you, and (2) lift upward and out.
M4 × 12
Screw
Air intake grille
Front panel
(2)
(1)
Grille stopper
English 5
2. In case of normal installation site.
Loosen the fixed screw and remove the bracket for installation (1) tentatively attached to the top panel. Fix the bracket with the attached screws (12) to the top panel as shown in the figure. Then fix the indoor unit to the wall surface with wood screws (field supply).
Fixing screw
Screw (12)
Bracket for installation (1)
(attached)
Bracket for installation (1)
(attached)
330
2-7 × 15 slot (For locking with
wood screw: field supply)
18
3. In the case of earthquake endurance installation site.
Perform the fixing procedure above and also fix the bottom frame. Fix the indoor unit to the floor with anchor bolts (to be locally procured) using fixing holes (×4) on the bottom frame.
Use the locations indicated on the installation pattern (9) (part of packing material).
4 - φ14 hole, Depth: 30
(For locking with bolt)
260
130
57
(79)
144
(202)
Front
Fixing hole (× 4)
Bottom frame
• Dimensions in ( ) for 100 - 125 models
• Unit [mm]

5. REFRIGERANT PIPING WORK

For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.〉 〈Execute heat insulation work completely on both sides of the gas piping and the liquid piping.
Otherwise, a water leakage can result sometimes.
(When using a heat pump, the temperature of the gas piping can reach up to approximately 120°C, so use insulation which is sufficiently resistant.)
Also, in cases where the temperature and humidity of the refrigerant piping sections might exceed 30°C or RH80%, reinforce the refrigerant insulation. (20mm or thicker) Condensation may form on the surface of the insulating material.
Before refrigerant piping work, check which type of refrigerant is used. Proper operation is not possible if the types of refrigerant are not the same.
6 English