Daikin FTS20JEV1K, RS20JEV1K, FTS25JEV1K, RS25JEV1K Installation manuals

INSTALLATION MANUAL
R410A SPLIT SERIES
MODELS FTS20JEV1K RS20JEV1K
FTS25JEV1K RS25JEV1K
Installation Manual
R410A Split Series
English
Part No.: R08019036975
Indoor Unit
THE MARK SHOWS PIPING DIRECTION
REAR REAR
TOP VIEW
OUTLINE AND DIMENSIONS
A
English
RIGHTLEFT
Original Instruction
C
NAME PLATE
BOTTOM BOTTOM
LOUVER
FRONT GRILLE FIXED SCREWS (INSIDE)
FRONT VIEW
Recommended mounting plate retention spots (7 spots in all)
D
F
SIGNAL RECEIVER
SIDE VIEW
INDOOR UNIT ON/OFF SWITCH
ROOM TEMPERATURE THERMISTOR (INSIDE)
E
B
TERMINAL BLOCK WITH EARTH TERMINAL
All dimensions are in mm
F
B
Through the wall hole Ø 65mm
G
HJ
Liquid pipe end Gas pipe end
L
M
A
K
G
I
Drain hose position
INSTALLATION PLATE FTS20/25JEV1K
All dimensions are in mm
Dimension
Model
ABCDE FGHI J KLM
FTS20/25JEV1K 1065 310 228 190 173 61 40 45 48 91 219 580 45
1
Outdoor Unit
KLL
P
A
O
QR
B
D
N
M
CN
FE
All dimensions are in mm
C
GH
ST
IJ
Dimension
Model
ABCDEFGH I JKLMNO
RS20JEV1K 855 628 328 508 181 44 93 149 101 113 603 126 164 17 49
RS25JEV1K 855 730 328 520 182 44 93 149 101 113 603 126 164 17 34
Dimension
Model
PQRS T
RS20JEV1K 32 3 237375
RS25JEV1K 32 3 237375
2
INSTALLATION MANUAL
This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirement. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
SAFETY PRECAUTIONS
! WARNING ! CAUTION
Installation and maintenance should be performed by
qualified persons who are familiar with local code and regulation, and experienced with this type of appliance. All field wiring must be installed in accordance with the
national wiring regulation. Ensure that the rated voltage of the unit corresponds to that
of the name plate before commencing wiring work according to the wiring diagram. The unit must be GROUNDED to prevent possible hazard
due to insulation failure. All electrical wiring must not touch the water piping or any
moving parts of the fan motors. Confirm that the unit has been switched OFF before
installing or servicing the unit. Risk of electric shock, can cause injury or death. Disconnect
all remain electric power supplies before servicing. DO NOT pull out the power cord when the power is ON.
This may cause serious electrical shocks which may result in the fire hazards. Keep the indoor and outdoor units, power cable and
transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}.
Please take note of the following important points when installing.
Do not install the unit where leakage of flammable
gas may occur.
If gas leaks and accumulates around the unit, it may
cause fire ignition.
Ensure that drainage piping is connected properly.
This unit is factory pre-charged. Overcharge will
If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.
Do not overcharge the unit.
cause over-current or damage to the compressor.
Ensure that the unit’s panel is closed after service or installation.
Un
secured panels will cause the unit to operate noi
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position to prevent the nuisance tripping of the unit. If this is not done, the unit’s
fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
Do not install the units at or near doorway. Do not operate any heating apparatus too close to the air conditioner unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction. When the unit is used in kitchen, keep flour away from going into suction of the unit. This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage fluctuates greatly. Do not install the units at area like hot spring or oil refinery plant where sulphide gas exists. Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively. IMPORTANT : DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM. Don’t use joined and twisted wires for incoming power supply. The equipment is not intended for use in a potentially explosive atmosphere.
sily.
English
Disposal requirement
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
NOTICE
3
INSTALLATION DIAGRAM
Indoor unit
Titanium apatite photocatalytic air-purifying fi lter
Front panel
50mm or more from walls (on both sides)
Air fi lter
Titanium apatite photocatalytic air-purifying fi lter (2)
Filter frame
Tab
M4 x 12L
Air fi lter
Outdoor Unit
30mm or more from ceiling
Opening service lid
Service lid is opening/
Opening method
Service lid
closing type.
1) Remove the service lid screws.
2) Pull out the service lid diagonally down in the direction of the arrow.
3) Pull down.
Caulk pipe hole gap with putty.
250mm from wall
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.
Wrap the insulation pipe with the nishing tape from bottom to top.
INSTALLATION OF THE OUTDOOR UNIT
The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air fl ow. Please follow the installation clearances shown in the fi gure. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (please refer operating range).
Installation clearances
Dimension
Minimum Distance, mm (in)
Note: If there is any obstacle higher than 2m, or if there is any
obstruction at the upper part of the unit, please allow more space than the fi gure indicated in the above table.
ABCD
300
(11.8)
1000
(39.4)
300
(11.8)
500
(19.7)
A
Obstacle
Return air
CD
Obstacle
Return air
B
Obstacle
Discharge air
Obstacle
Service access
4