OPERATION MANUAL
Split system air conditioners
FFQ25B9V1B
FFQ35B9V1B
FFQ50B9V1B
FFQ60B9V1B
FFQ25B9V1B
FFQ35B9V1B
FFQ50B9V1B
FFQ60B9V1B
Split system air conditioners
Operation manual
CONTENTS Page
What to do before operation ..............................................................1
Important information regarding the refrigerant used ........................ 1
Safety considerations ........................................................................ 1
Names and functions of parts............................................................ 1
Operation range................................................................................. 2
Installation site................................................................................... 2
Name and function of each switch and display
on the remote controller..................................................................... 2
Operation procedure.......................................................................... 2
Optimum operation ............................................................................2
Not a malfunction of the air conditioner .............................................3
Troubleshooting .................................................................................4
Maintenance ......................................................................................4
The original instructions are written in English. All other languages
are translations of the original instructions.
THANK YOU FOR PURCHASING THIS DAIKIN AIR
CONDITIONER. CAREFULLY READ THIS OPERATION
MANUAL BEFORE USING THE AIR CONDITIONER. IT
WILL TELL YOU HOW TO USE THE UNIT PROPERLY
AND HELP YOU IF ANY TROUBLE OCCURS. AFTER
READING THE MANUAL, FILE IT AWAY FOR FUTURE
REFERENCE.
WHAT TO DO BEFORE OPERATION (See figure 1)
This operation manual is for the following systems with standard
control. Before initiating operation, contact your Daikin dealer for the
operation manual that corresponds to your system.
NOTE
If your installation has a customized control system, ask your Daikin
dealer for the operation that corresponds to your system.
These units can be controlled by a remote controller.
Refer to the manual of the remote controller for more
information.
A Pair system
B Multi system
1 Unit with remote controller
IMPORTANT INFORMATION REGARDING THE
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Refrigerant type: R410A
(1)
value: 1975
GWP
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
SAFETY CONSIDERATIONS
■ Never let the indoor unit and the remote controller get
wet.
It may cause an electric shock or a fire.
■ Never use flammable spray such as hair spray,
lacquer or paint near the unit.
It may cause a fire.
■ Never replace a fuse with that of a wrong ampere
rating or other wires when the fuse blows out.
Use of wire or copper wire may cause the unit to
break down or cause a fire.
■ This appliance is not intended for use by persons,
including children, with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.
■ Never touch the air outlet or the horizontal blades
while the swing flap is in operation.
Fingers may become caught or the unit may break down.
■ Never insert objects such as sticks into the air inlet or
outlet. It is dangerous for an object to touch the fan
when it is turning at high speed.
■ Never remove the fan guard of the outdoor unit.
The rotating fan at high speed without the guard is
very dangerous.
■ Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.
■ Heat pump type
This system provides cooling, heating, automatic, and fan
operation modes.
■ Straight cooling type
This system provides cooling, and fan operation modes.
FFQ25~60B9V1B
Split system air conditioners
4PW70943-1 – 08.2011
NAMES AND FUNCTIONS OF PARTS (See figure 2)
1 Indoor unit
2 Discharged air
3 Inlet air
4 Remote controller
5 Connection electric wire
6 Refrigerant piping
7 Drain pipe
8 Outdoor unit
9 Ground wire
Wire to ground outdoor unit to prevent electrical shocks.
Operation manual
1
OPERATION RANGE
If operating outside the following conditions, safety devices may
activate, rendering the air conditioner inoperable or may cause the
indoor unit to sweat.
The setting temperature range of the remote controller is 16°C~32°C.
°
C
RS50-60
RKS25-35-50-60
RXS25-35-50-60
3MKS50
4MKS58-75-90
3MXS52
4MXS68-80
RZQ(G)71-100-125-140
RZQS(G)71-100-125-140
RXS25-35 °C DB 10~30
RXS50-60 °C DB 10~30
3MXS52
4MXS68-80
RZQ(G)71-100-125-140
RZQS(G)71-100-125-140
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB 10~30
°C DB 10~27
°C DB 10~27
21~32
14~23
21~32
14~23
18~35
12~28
18~35
14~28
°
C
≤80%
≤80% –10~46
≤80% –15~50
≤80% –5~46
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
(DB=dry bulb, WB=wet bulb, =cooling, =heating, =indoor,
°
=outdoor, =temperature, =humidity)
(*) For Australian models: –5~46°C
C
°
C
–10~46
°
C
–10~24
–15~20
–14~24
–15~18
–10~21
–15~15.5
–13~21
–20~15.5
–9~21
–10~15.5
(*)
OPERATION PROCEDURE
■ If a function that is not available is selected, the
message NOT AVAILABLE will appear.
■ Operating procedure varies with heat pump type and
straight cooling type. Contact your Daikin dealer to
confirm your system type.
■ To protect the unit, turn on the main power switch
6 hours before operation.
■ If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.
NOTE
Precautions for group control system or two remote
controller control system
This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.
■ Group control system
■ Tw o remote controller control system
NOTE
Set the temperature within the ranges mentioned
under "Operation range" on page 2.
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
Tw o remote controllers control one indoor unit (In case of group
control system, one group of indoor units). The unit is
individually operated.
Contact your Daikin dealer in case of changing the
combination or setting of group control and two remote
controller control systems.
INSTALLATION SITE
■ Never place anything under the indoor unit that you
don't want to get wet.
The unit may sweat when the humidity is over 80% or
when the drain outlet is clogged.
■ Never place other heating equipment directly beneath
the indoor unit. Subject to deformation caused by
heat.
■ Do not place TV, radio, stereo, etc. within 1 meter from
the indoor unit and remote controller.
Doing so may cause interference in the picture or
sound.
■ Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.
NAME AND FUNCTION OF EACH SWITCH AND
DISPLAY ON THE REMOTE CONTROLLER
Refer to the operation manual delivered with the remote
controller.
OPTIMUM OPERATION
Observe the following precautions to ensure the system operates
properly.
■ Adjust the air outlet properly and avoid direct air flow to room
inhabitants.
■ Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
■ Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
■ Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and decrease the effect of
cooling and heating.
■ Never place objects near the air inlet and the air outlet of the
unit. It may retard effectiveness or cause operation to stop.
■ Tu rn off the main power supply switch when not using for long
periods of time. Electricity is consumed as long as the switch is
on. Turn off the main power supply switch in order to save
energy. Turn on the main power supply switch 6 hours before
restarting operation in order to ensure smooth operation. (Refer
to "Maintenance" on page 4.)
■ When the display shows " " (TIME TO CLEAN AIR
FILTER), have a qualified service person to clean the filters.
(Refer to "Maintenance" on page 4.)
Operation manual
2
FFQ25~60B9V1B
Split system air conditioners
4PW70943-1 – 08.2011