Daikin FDM20JEVLK, RD20JEVLK, FDM25JEVLK, RD25JEVLK, FDM30JEVLK Installation manuals

...
INSTALLATION MANUAL
R22 SPLIT SERIES
MODELS FDM20JEVLK RD20JEVLK
Installation Manual
R22 Split Series
English
FDYM40JEVLK RYD40JEVLK FDYM50JEVLK RYD50JETLK FDYM60JEVLK RYD60JETLK
IM-CCC/E-0311(0)-DAIKIN (SASO)
Part No.: R08019036182
Indoor Unit
OUTLINE AND DIMENSIONS
All dimensions are in mm
I J
K
L
Model
H
Dimension
B
D C
O
E
A
MN G
F
ABCDE FGHI J KLMNO
FD(Y)M20JEVLK 31 1041 1002 962 10 1065 72 261 411 351 225 211 232 213 114
FD(Y)M25JEVLK 31 1176 1137 1097 10 1200 72 261 411 351 225 211 232 213 114
English
Original Instruction
Indoor Unit
Dimension
Model FD(Y)M30JEVLK
FD(Y)M40JEVLK
K
J
I
H
B
A
DE
C
G
F
P
All dimensions are in mm
L
M
N
O
AB C D E FG H I J K LMNOP
40 292 1295 232 213 70 128 1228 1185 284 1262 460 420 241 12 230
1-1
Indoor Unit
All dimensions are in mm
J
Model
Dimension
EE
AAK
B
C
D
L
MN
K
G
H
I
F
ABCDE FGHI JKLMN
FD(Y)M50JEVLK 359 1369 1326 1287 594 384 541 256 173 306 256 161 248 220 FD(Y)M60JEVLK 359 1569 1526 1487 694 378 541 256 173 306 356 161 248 220
Outdoor Unit
Model
Dimension
L
O
PBQ
ABCDE FGHI J KLMNOPQRS T
KL
M
A
D
All dimensions are in mm
N
TN
C
F
E
S
R
HG
IJ
R(Y)D20JEVLK 855 628 328 508 181 44 93 149 101 113 603 126 164 15 49 3 23 73 75 362 R(Y)D25JEVLK 855 730 328 520 182 44 93 149 101 113 603 126 164 15 34 3 23 73 75 362 R(Y)D30JEVLK 855 730 328 513 182 44 93 149 101 113 603 126 164 15 47 3 23 73 75 362
1-2
Outdoor Unit
All dimensions are in mm
Dimension
Model R(Y)D40JEVLK
R(Y)D50JETLK R(Y)D60JETLK
N
K
D
B
F
E
A
M
P
L
T
R
G
S
U
Q
C
H
J
AB C D E FGH J K LMN PQ R S TU
1030 852 428 410 412 827 72 196 91 488 448 142 141 83 23 49 26 28 80
English
1-3
INSTALLATION MANUAL
This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirements. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
SAFETY PRECAUTIONS
! WARNING ! CAUTION
• Installation and maintenance should be performed by qualiÀ ed persons who are familiar with local code and regulation, and experienced with this type of appliance.
• All À eld wiring must be installed in accordance with the national wiring regulation.
• Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
• The unit must be GROUNDED to prevent possible hazard due to insulation failure.
• All electrical wiring must not touch the refrigerant piping, or any moving parts of the fan motors.
• ConÀ rm that the unit has been switched OFF before installing or servicing the unit.
• Disconnect from the main power supply before servicing the air conditioner unit.
• DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in À re hazards.
• Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. (Depending on the type and source of the electrical waves, static may be heard even when more than 1m away).
Please take note of the following important points when installing.
Do not install the unit where leakage of Á ammable gas may occur.
If gas leaks and accumulates around the unit, it may
cause À re ignition.
Ensure that drainage piping is connected properly.
If the drainage piping is not connected properly, it may
cause water leakage which will dampen the furniture.
Do not overcharge the unit.
This unit is factory pre-charged. Overcharge will cause over-current or damage to the
compressor.
Ensure that the unit·s panel is closed after service or
installation.
Unsecured panels will cause the unit to operate
noisily.
Sharp edges and coil surfaces are potential locations
which may cause injury hazards.
Avoid from being in contact with these places.
Before turning off the power supply, set the remote controller·s ON/OFF switch to the “OFF” position to prevent the nuisance tripping of the unit. If this is not
done, the unit·s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
Do not install the units at or near doorway.
Do not operate any heating apparatus too close to the
air conditioner unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction.
When the unit is used in kitchen, keep Á our away from going into suction of the unit.
This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage Á uctuates greatly.
Do not install the units at area like hot spring or oil reÀ nery plant where sulphide gas exists.
Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
IMPORTANT: DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.
Don·t use joined and twisted wires for incoming power supply.
The equipment is not intended for use in a potentially explosive atmosphere.
Disposal requirements
NOTICE
Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualiÀ ed installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information. Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
1-4
IMPORTANT & SEQUENCE AS FOLLOW:
For model FD(Y)M20JEVLK & FD(Y)M25JEVLK:
2) Left Cushion
4) Indoor Unit
1) Carton Box
UNPACKING
1) After take off the bands, lift the unit out from the carton box
2) Remove the right and left cushion.
English
3) Right Cushion
For model FD(Y)M30JEVLK & FD(Y)M40JEVLK:
1) Carton Box
3) Indoor Unit
2) Top Carton
UNPACKING
1) After take off the bands, lift the carton box
2) Remove the top cushion.
3) Lift the unit and remove the bottom carton.
4) Bottom Carton
1-5
For model FR(Y)M50JEVLK & FD(Y)M60JEVLK:
1) Carton Box
2) Top Cushion
3) Indoor Unit
4) Packing bottom
UNPACKING
1) After take off the bands, lift the carton box
2) Remove the top cushion.
3) Lift the unit and remove the bottom carton.
For model R(Y)D20JEVLK, R(Y)D25JEVLK, R(Y)D30JEVLK, R(Y)D40JEVLK, R(Y)D50JETLK & R(Y)D60JETLK:
1. After take off the bands, pull out the carton box from the top side of the unit.
* This product is not designed for re-packing. In case of re-packing, contact to Daikin Dealer.
1-6
INSTALLATION DIAGRAM
Indoor unit
Hanger
Supply Duct
Air Intake
Drain Piping
English
Return Duct
Wrap the insulated pipe with the À nishing tape from bottom to top
Thermal Insulation
Air Intake
Air Discharge
Outdoor unit
1-7
Loading...