ANALOGUE THERMOSTAT 230 V
EKWCTRAN1V3 |
1 |
2 |
The thermostat can be used in heating and cooling
systems. If you want to block the cooling function, connect the lower left contacts to each other in de energized state.
|
Setback temperature |
|
The reduction of 2 K can be activated to by |
|
2 K L/L1, e. g. by an external timer. |
1x |
2x |
|
1. Switch off the voltage supply.
2. Remove the wiring.
3. Take off the thermostat and dispose of it properly.
The EKWCTRAN1V3 is intended for regulating the room temperature by setting the desired target temperature for the activation of actuators in heating/cooling operation. Every other use is considered not intended; the manufacturer cannot be held liable for unintented use.
¾¾ The electrical installation must be performed according to the current national VDE regulations as well as according to the regulations of your local electric power utility company, by an authorised and trained electrician, and in a de-energized state.
¾¾ Only an authorised electrician may open the device. It may only be opened in de-energized state.
¾¾ Only use the device if it is in perfect state.
¾¾ Ensure that children do not play with this device. Children must be monitored if necessary.
https://qr.daikin.eu?N=EKWCTRAN1V3
|
Installation position |
± 30 cm |
External heat |
sources will impact |
|
<![if ! IE]> <![endif]>cm |
the thermostat’s |
performance. |
|
<![if ! IE]> <![endif]>± 150 |
|
1 |
|
2a |
3,5 mm |
3 |
|
|
* |
|
|
2b |
60 mm |
4 |
|
CO |
|
|
|||
|
|
|
|
µC |
* Protective cover |
|
|
|
Mount the thermostat directly on the wall or on a flush-type box. Make the electric connection as shown in figure 3.
Target value regulator
Set the target temperature by rotating the target value regulator
1 |
|
|
|
2 |
Target value calibration |
|
|
|
1. Remove the target value |
||
|
|
|
|
|
|
|
|
|
|
|
regulator. |
|
|
|
|
|
2. Set the target value |
|
|
|
|
|
correction: An alignment |
|
|
|
|
|
to the room temperature |
|
|
|
|
|
is possible between |
|
|
|
|
|
-2 K ... +2 K. |
3 |
|
|
15 |
4 |
|
25 |
|
|
|
|
|
28 |
|
|
|
10 |
|
- |
|
|
|
|
|
2K |
- |
0 |
+2K |
|
|
|
1 |
+1 |
|
|
|
1 |
|
|
2x |
2 |
Optional – Limiting the |
|
|
|
temperature range |
||
|
|
|
|
|
|
|
|
|
|
|
Insert and set the limiters |
|
|
|
|
|
for minimum and maximum |
|
|
|
|
|
temperature. |
1
|
|
Technical data |
|
Operating voltage: |
230 V ±10 %, 50 Hz |
Fuse 230 V: |
T2AH |
Switching elem. 230 V: |
Relay |
Switching power 230 V: |
2 A resist. load |
Rated current w/o valve drives: |
230 V: ≤2 mA |
Max current draw allowed |
|
with connected valve drives: |
230 V: 1.8 A |
Temperature setting range: |
10 °C - 28 °C |
Target value calibration: |
±2 K |
Reduction temperature: |
2 K |
Temperature measurement: |
0 - 40 °C |
Measuring accuracy: |
±0.5 K |
Ambient temperature: |
0 - 50 °C |
Storage temp. range: |
-25 to +75 °C |
Admissible amb. humidity: |
80%, not condensing |
Temp. for ball pressure test: |
Terminals: 100 °C |
|
Plastic enclosure: 75 °C |
CE conformity according to: |
EN 60730 |
Protect. class 230 V: |
II |
Protection degree: |
IP 20 |
Rated impulse voltage: |
1500 V |
Pollution degree: |
2 |
Type action: |
Type 1 / Type 1.C |
Weight: |
90 g |
Dimensions (W x H x D): |
86 x 86 x 29 mm |
Antifreeze function: From +6 °C in heating mode, inactive in cooling mode.
Only thermostats with heating/cooling function:
Valve protection function: Once every 14 days for 6 minutes after the last activation
This symbol means that electrical and electronic products may
NOT be mixed with unsorted household waste. Units must be treated at a specialized treatment facility for reuse, recycling and recovery.
By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health.
For more information, contact your installer or local authority.
<![if ! IE]><![endif]>Copyright 2019 Daikin
2 |
4P560991-1 2019.01 |