DCC601A51 intelligent Tab Controller
Installation manual
Contents page
1. About this document.................................................................. 1
1.1. Target audience ................................................................ 1
1.2. Documentation set............................................................ 1
2. General safety precautions........................................................ 1
2.1. General............................................................................. 1
2.2. Installation site.................................................................. 1
2.3. Electrical ........................................................................... 1
3. Contents of the kit and optional equipment ............................... 2
3.1. Contents of the kit............................................................. 2
3.2. Optional equipment .......................................................... 2
4. System overview ....................................................................... 2
4.1. The Daikin intelligent Tab Controller solution ................... 2
4.2. The intelligent Tab Controller kit ....................................... 2
4.3. Compatible (Daikin) equipment ........................................ 2
4.4. Additional components in the intelligent
Tab Controller solution...................................................... 3
5. Before installation ...................................................................... 4
5.1. Necessary equipment....................................................... 4
5.2. Determining installation place........................................... 4
5.3. The location of terminals and switches............................. 4
6. Installation of the intelligent Tab Controller hardware................ 6
7. Electric wiring ............................................................................ 6
7.1. Connecting to other equipment ........................................ 6
7.2. Connecting the power supply to all modules .................... 7
7.3. Connecting the LAN cable................................................ 8
8. Technical specifications............................................................. 8
8.1. Environmental conditions ................................................. 8
8.2. Electrical cabinet .............................................................. 8
8.3. Power consumption specifications ................................... 8
8.4. Other intelligent Tab Controller specifications .................. 8
8.5. Wiring requirements ......................................................... 9
9. Commissioning the intelligent Tab Controller setup................... 9
10. Disposal requirements............................................................... 9
11. Copyright and trademarks ......................................................... 9
2. General safety precautions
Please read these general safety precautions carefully before
installing the intelligent Tab Controller kit.
After completing the installation, make sure the power supply and
intelligent Tab Controller modules operate properly during the startup
operation.
2.1. General
If you are not sure how to install or operate the modules, contact your
dealer.
NOTICE
Improper installation or attachment of equipment or
accessories could result in electric shock, short-circuit,
leaks, fire or other damage to the equipment. Only use
accessories, optional equipment and spare parts made or
approved by Daikin.
WARNING
Make sure installation, testing and applied materials
comply with the applicable legislation (on top of the
instructions described in the Daikin documentation).
CAUTION
Wear adequate personal protective equipment (protective
gloves, safety glasses,…) when installing, maintaining or
servicing the system.
WARNING
Tear apart and throw away plastic packaging bags so that
nobody, especially children, can play with them. Possible
risk: suffocation.
1. About this document
1.1. Target audience
Authorised installers
1.2. Documentation set
This document is part of a documentation set. The complete set
consists of:
Installation manual:
Installation instructions
Format: Paper (supplied in the kit)
Installer reference guide:
Preparation of the installation, technical specifications,
reference data,...
Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2.2. Installation site
Do NOT install the equipment in a potentially explosive atmosphere.
2.3. Electrical
DANGER: RISK OF ELECTROCUTION
Turn OFF all power supply before connecting
electrical wiring or touching electrical parts.
Disconnect the power supply for more than 1 minute,
and measure the voltage at the terminals of main
circuit capacitors or electrical components before
servicing. The voltage must be less than 50 V DC
before you can touch electrical components. For the
location of the terminals, see the wiring diagram.
Do NOT touch electrical components with wet hands.
Do NOT leave the equipment unattended when the
service cover is removed.
WARNING
A main switch or other means for disconnection, having a
contact separation in all poles providing full disconnection
under overvoltage category III condition, shall be installed
in the fixed wiring.
Installation manual
1
intelligent Tab Controller
4P414342-1B – 2015.10
DCC601A51
WARNING
Only use copper wires.
Make sure the field wiring complies with the
applicable legislation.
All field wiring must be performed in accordance with
the wiring diagram supplied with the product.
Make sure to install earth wiring. Do NOT earth the
unit to a utility pipe, surge absorber, or telephone
earth. Incomplete earth may cause electrical shock.
Make sure to use a dedicated power circuit. NEVER
use a power supply shared by another appliance.
Make sure to install the required fuses or circuit
breakers.
Make sure to install an earth leakage protector.
Failure to do so may cause electric shock or fire.
Install the wires at least 1 meter away from televisions or radios to
prevent interference. Depending on the radio waves, a distance of
1 meter may not be sufficient.
WARNING
After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
cabinet is securely connected.
Make sure all covers are closed before starting up the
units.
3. Contents of the kit and optional
equipment
3.1. Contents of the kit
3.2. Optional equipment
The following optional equipment is available:
Equipment Typ e Material nr.
Daikin-supplied router ASUS 4G-N12 4G-N12
Daikin-supplied tablet ASUS ZenPad Z380C Z380C
For more information on this optional equipment, refer to
"4.4. Additional components in the intelligent Tab Controller solution"
on page 3.
4. System overview
4.1. The Daikin intelligent Tab Controller solution
The Daikin intelligent Tab Controller solution allows an end-user to
control and manage a wide range of Daikin HVAC equipment from a
tablet app and web browser interface.
The intelligent Tab Controller solution is available in one of the two
following function modes (i.e., operation modes):
Stand-alone mode: A local function mode where you can
control your local environment from anywhere within your local
area network. This is done via the intelligent Tab Controller app
on the Daikin-supplied tablet.
Cloud-connect mode: A cloud-based function mode where you
can control multiple environments from anywhere in the world.
This is done via a browser application by accessing the cloud at:
http://cloud.daikineurope.com. Note that the cloud can also be
accessed using a browser running on the Daikin-supplied tablet.
In cloud-based function mode, local control via the intelligent
Tab Controller app is still possible, but the provided feature set
will be restricted.
Based on the following accessory list, check that all parts and
accessories for the intelligent Tab Controller are included in the kit. If
there is any missing or defective part, contact the Daikin dealer
where you purchased this product.
a
c
--
++
b
d
e
L
N
a CPU module (1×)
b I/O module (1×)
c WAGO power supply unit (1×)
d USB cable (1×)
e Installation manual (this manual) (1×)
4.2. The intelligent Tab Controller kit
In order to set up the intelligent Tab Controller solution in your
environment, you have been given the Daikin intelligent Tab
Controller kit. This kit provides a central controller and links the
supported Daikin equipment to a local Ethernet network and the
cloud. The kit consists of the following components:
a WAGO power supply unit (PSU)
the CPU module
the I/O module
For a typical setup of the intelligent Tab Controller kit, refer to
"Schematic setup of the intelligent Tab Controller" on page 3. Before
installing the intelligent Tab Controller kit modules, draw up an
efficient plan of work, using this schematic and the actual
environment it needs to be installed in.
4.3. Compatible (Daikin) equipment
Currently, the intelligent Tab Controller solution can connect to Daikin
units that provide a DIII-NET communication interface. The
connection of Daikin equipment that uses other communication
interfaces might be supported in future upgrades. For an up-to-date
list of which equipment can be controlled using the intelligent Tab
Controller, refer to the following site:
http://www.daikineurope.com/support-and-manuals/productinformation/.
NOTICE
The intelligent Tab Controller cannot be used in
combination with other centralised controllers, like the iTM.
In addition, a number of terminals are available on the I/O module to
connect digital inputs. The digital input on the first terminal is
hardwired as a forced stop contact input. The remaining digital inputs
can each be configured as either a normal-open or normal-closed
contact input, or as a pulse input.
DCC601A51
intelligent Tab Controller
4P414342-1B – 2015.10
Installation manual
2
NOTICE
USB
230 V AC
RJ-45
F1, F2
P1, P2
F1, F2 P1, P2 F1, F2 P1, P2
F1, F2 F1, F2
http://cloud.daikineurope.com
DIII-NET
POWER I/O IF
CPU IF
LAN
F1/F2
Di1 - Di4
de f
iiih
j
k
24 V DC c
b
g
a
ll
++
--
L
N
When the forced stop contact input is closed, a stop signal
is sent to all connected devices. There is no hard
guarantee that all devices are actually stopped and remain
stopped during the time the forced stop contact input is
active.
4.4. Additional components in the intelligent Tab
Controller solution
The following optional equipment is available as part of the intelligent
Tab Controller solution. Its requirements depend on your local
environment and needs. Contact your dealer for more information.
Schematic setup of the intelligent Tab Controller
Daikin-supplied router (ASUS 4G-N12)
An optional Daikin-supplied router can be used to create a WiFicapable LAN. This might be necessary if the intelligent Tab Controller
modules cannot be connected to the locally-available LAN, or if the
locally-available LAN does not provide WiFi for access by the Daikinsupplied tablet.
In addition, the router has mobile 4G capabilities, which can be used
to provide connection to the cloud in case an internet connection is
not available using a locally-available LAN. Note that for a mobile
internet connection, a SIM card is required, which is not supplied with
the router.
Daikin-supplied tablet (ASUS ZenPad 8.0 Z380C)
A Daikin-supplied tablet has to be used for running the intelligent Tab
Controller app if you choose the local function mode.
The intelligent Tab Controller app can be installed from Google Play.
a WAGO power supply unit
b CPU module
c I/O module
d Optional Daikin-supplied tablet
e Computer with connection to the cloud
f Cloud
g LAN gateway (optional Daikin-supplied router)
h Outdoor unit connected to DIII-NET
i Indoor unit connected to DIII-NET
j Forced stop contact input
k Digital inputs (can be configured as contact inputs or pulse
inputs)
l Remocon
Installation manual
3
intelligent Tab Controller
4P414342-1B – 2015.10
DCC601A51