Crown CTS-600 Brochure

AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz. Typical line impedance used. Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5. Data based on all channels driven.
CTs 600
Load
1/8th Power Pink Noise 8 Ohms/Ch.
Typical of program material 16 Ohms Bridge just at clip. 4 Ohms/Ch.
8 Ohms Bridge 2 Ohms/Ch. 4 Ohms Bridge 70V/Ch. 300x2 140V Bridge 600
1/3rd Power Pink Noise 8 Ohms/Ch.
Typical of program material 16 Ohms Bridge with severe clipping. 4 Ohms/Ch.
8 Ohms Bridge 2 Ohms/Ch. 4 Ohms Bridge 70V/Ch. 300x2 140V Bridge 600
Rated
Power
300x2 600 300x2 600 150x2 300
300x2 600 300x2 600 150x2 300
Line Current
120VAC
5.8
7.4
7.0
4.2
8.6
11.3
10.8
6.5
Line Current
230VAC
2.9
3.7
3.5
2.1
4.3
5.6
5.4
3.3
watts in
Watts
watts out dissapated
Thermal Dissipation
Btu/hr kcal/hr
60 0 60 205 52
461
631
583
336
716
968
964
527
78
78
38
75
200
204
102
207
383
554
545
261
516
764
862
320
1307
1890
1859
892
1760
2608
2942
1091
330
477
469
225
444
657
742
275
Loading...