when the rear-panel Mode Switch is set to the
“Bridge” position.
Ready Indicator: Green LED, one per channel,
illuminates when the channel is initialized and
ready to produce audio output. Indicator is off
when PIP puts the amplifier in standby mode via
the control system.
Signal Indicators: Three green LEDs per channel indicate the amplifier’s input and output
signal levels.
Signal: input signal is above –40 dBu.
–20 dB: amplifier output is 20 dB below clipping.
–10 dB: amplifier output is 10 dB below clipping.
Clip Indicator: Red LED, one per channel,
illuminates when the channel’s output signal
reaches the onset of audible clipping. The Clip
Indicator also will illuminate during Thermal
Level Control (TLC) limiting or when the input
compressor/limiter is protecting the amplifier
from input overload.
Thermal Indicator: Red LED, one per channel,
illuminates when the channel has shut down,
or is very near shutting down, due to thermal
stress or overload.
Fault Indicator: Red LED, one per channel,
flashes when the amplifier output channel has
stopped operating.
Data Indicator: Yellow LED indicates control
data activity (if the amplifier is equipped with
an IQ-PIP2 module, and connected to a control
system).
Power Indicator: Blue LED indicates amplifier
has been turned on and AC power is available.
The LED will flash when the AC line voltage is
15% above or 25% below the nominal rated
value.
inlet. Voltage is indicated above IEC inlet.
Reset Switch: Resets the circuit breaker that
protects the power supply.
Speaker Connectors: One four-pole touch-proof
terminal strip. Accepts up to 10 AWG terminal
forks.
Input Connectors: Balanced 2-pin terminal block
connector, one per channel, on the standard
PIP2-BBY module.
Channel Level Control: One 21-position
detented rotary attenuator per channel, ranging
from minus infinity (–70 dB) to 0 dB gain.
Mode Switch: Two-position switch is used to
select the amplifier’s mode of operation: Dual or
Bridge-Mono.
Highpass Filter: One 3-position switch per
channel selects between OFF, 35Hz and 70Hz
3rd-order filters.
“Y” Input Switch: When set to ON, this switch
parallels the input signals of the two channels
for use when the input signal is mono. Also can
be used to daisy-chain the signal to another
amplifier.
Ventilation Grille: Front-to-rear forced airflow.
Options
PIP2 modules, including the PIP-Lite, PIP-USP3,
and PIP-USP3/CN.
Protection Systems
Thermal Level Control (TLC): If an amplifier
channel starts to overheat, the TLC circuit will
engage the input compressor. By compressing
the input, the amplifier will not generate as much
heat and will have a chance to cool down.
Junction Temperature Simulation (JTS): In the
CTs 600/1200, if excess power is demanded,
JTS circuitry limits the drive level of the output
devices to a safe range, preventing damage.
Fault: The amplifier will light the Fault LED if the
amplifier output stage stops operating.
AC Under-/Over-Voltage Protection: If the AC
line voltage drops below 25% or rises above
15% of the nominal operating voltage of the
amplifier, the amplifier’s power supply turns
off and the blue Power LED flashes. The amplifier will turn back on when the AC line voltage
returns to safe operating levels.
Circuit Breaker: This breaker protects the amplifier from excessive AC current draw.
DC Output Servo: The output servo circuit
protects your drivers by eliminating DC offset,
even in the presence of very large asymmetrical
signals.
In-rush Limiting: A soft-start circuit in the
power supply minimizes the amplifier’s current
draw during power-on.
Variable-speed Fan: Two continuously variable
speed fans direct the airflow through the amplifier for cooling.
Regulatory Certifications
Other Applications
rown’s CTs Series amplifiers provide exceptional performance, flexibility and value for installed
C
sound applications. CTs Series amplifiers feature independent selection of high and low impedance
operation for a specific channel, plus power levels and features that were carefully chosen to match
the requirements of fixed install design. Easy integration with HiQnet™ and CobraNet™ allows CTs
amplifiers to deliver a comprehensive lineup of monitoring and control features along with digital audio
transport for an award-winning digital audio solution.
9/07 136317-2B
INSTALLED SOUND
Page 6
AMPLIFIERS INSTALLED SOUND
CTs Multi-Channel Series: The New Standard
CTs 4200, CTs 8200
Flexibility
FEATURES
• High power density: Four-channel model in a 2U chassis,
eight-channel model in a 3U chassis.
• New Crown Switching Power Supply for lighter weight.
• Selectable “Constant-Voltage” or low-impedance (4/8 ohm)
operation per channel-pair.
• 100V direct outputs.
• New “FIT” (Fault Isolation Topology) circuitry isolates fault
conditions without affecting neighboring channels.
AC Line Voltage and Frequency Configurations
Available (±10%):120V/60 Hz, 220/230/240V/50
Hz.
Power Draw at Idle (120VAC mains, all channels
in 4/8 ohm mode): 58W.
Power Draw at Idle (120VAC mains, all channels
in 70V mode): 77W.
Cooling: Continuously variable speed forced air,
front-to-back airflow.
Dimensions (Width, Height, Depth):
CTs 4200: 19 in. (48.3 cm) W x 3.5 in. (8.9 cm)
H x 16.25 in. (41.3 cm) D.
CTs 8200: 19 in. (48.3 cm) W x 5.25 in. (13.3
cm) H x 16.25 in. (41.3 cm) D.
Weight (Net, Shipping):
CTs 4200: 27 lb 8 oz (12.5 kg),
32 lb (14.5 kg)
CTs 8200: 36 lb 6 oz (16.5 kg),
47 lb (21.3 kg).
Front Panel Controls and Indicators
Bridge Mode Indicator: Yellow LED, one per
channel pair, illuminates when the channel pair’s
Mode Switch is set to the “Bridge” position. If Mode
switch is changed while amplifier is powered up,
Bridge LED will flash, indicating that the amplifier
must be powered off and on to reset the Mode.
Ready Indicator: Green LED, one per channel,
illuminates when the channel is initialized and ready
to produce audio output.
rown’s CTs Multi-Channel Series offers wide flexibility for a wide range of installed sound applica-
C
tions. CTs Multi-Channel Series amplifiers offer independent selection of high- and low-impedance
operation for each channel pair, making these amps ideal for multi-zone installations.
Signal Indicator: Green LED, one per channel,
illuminates to indicate the presence of analog input
signals above –40 dBu.
Clip Indicator: Red LED, one per channel, illuminates when the THD of the channel’s output signal
rises to a level typically considered as the onset of
audible clipping. The Clip Indicator also will illuminate during Thermal Level Control (TLC) or input
overload.
Thermal Indicator: Red LED, one per channel,
flashes when a state of thermal stress or overload
has caused the channel to shut down. If the power
supply goes into thermal overload, all channel LEDs
will flash.
Fault Indicator: Red LED, one per channel, flashes
when a fault condition has occurred in the channel.
Ventilation Grille: Front-to-rear forced airflow.
Data Indicator: Yellow LED indicates IQ Loop data
activity (if the amplifier is equipped with an IQ-MC
module, and connected to an IQ Loop).
Power Indicator: Blue LED indicates amplifier has
been turned on and AC power is available. Indicator also flashes if the amplifier shuts off due to an
under-/over-voltage condition on the AC mains.
Power Switch: Amplifier is on when the switch is in
the IN position.
Back Panel Controls and Connectors
AC Power Cord Connector: IEC inlet, type 320;
100/120VAC units: 15A;
220/230/240VAC units: 10A.
Voltage is indicated above IEC inlet.
Output Connectors: One four-pole terminal strip
for every two channels with touch-proof cover.
Accepts up to 10 AWG terminal forks.
Accessory Panel: CTs 4200 accepts an optional
VCA-MC4A module. CTs 8200 accepts an optional
VCA-MC8 module.
Channel Level Controls: One 21-position detented
rotary potentiometer per channel, ranging from
infinity (–70 dB) to 0 dB attenuation.
Input Connectors: Removable Phoenix-style barrier
connectors for balanced input. Also can be used as
a CobraNet input or a backup for CobraNet.
Mode Switch: Used on each consecutive pair of
channels, this four-position switch is used to select
the amplifier’s mode of operation: Dual 8/4 ohms,
Dual 70V, Bridge-Mono 16/8 ohms, and BridgeMono 100V.
T-170V: This is an autoformer that allows 100V
output from the amplifier, and allows other amplifiers without direct constant voltage output to be
easily integrated into distributed systems.
TP-170V: This is a rack-mountable panel with four
autoformers as described above.
Protection Systems
Thermal Level Control (TLC): If an amplifier channel starts to overheat, the TLC circuit will engage
that channel’s input compressor. By compressing the input, the amplifier will not generate as
much heat and will have a chance to cool down.
The degree of compression is proportional to the
amount of overheating. If the channel becomes too
hot for safe operation even after full TLC limiting,
the channel will shut off, and the Thermal Indicator
for that channel will flash brightly to alert the user
that a state of thermal stress or overload has cause
the channel to shut down.
FIT (Fault Isolation Topology): Isolates faults within
affected channels.
Fault: If an amplifier channel requires service, the
corresponding Fault indicator will illuminate to alert
the user of this condition. If this occurs, return the
amplifier to the Crown factory or to an authorized
Crown service center.
High-Pass Filter: A fixed 35-Hz (70-Hz in CTs 4200)
high-pass filter per channel pair is automatically
inserted when the mode switch is set to either of
the constant-voltage settings. The high-pass filter
corner frequency in the CTs 8200 can be set to 70
Hz, or bypassed, with a service option.
AC Under-/Over-Voltage Protection: If the AC
line voltage varies out of an acceptable range, the
amplifier’s power supply turns off and the blue
Power LED flashes. The amplifier will turn back on
when the AC line voltage returns to safe operating
levels.
Models
100VAC
(CTs 8200 only)
120 VAC units108VAC132VAC
220V/230V/240V
units
Power Fuse: A fuse protects the amplifier from
excessive AC current draw.
Inrush Limiting: A soft-start circuit in the power
supply minimizes the amplifier’s current draw
during power-on.
Variable-speed Fan: Continuously variable speed
fan directs the airflow through the amplifier for
cooling.
Regulatory Certifications
Under-Voltage
Limit
90VAC110VAC
198VAC264VAC
Over-Voltage
Limit
Other Applications
8/07 136318-1K
INSTALLED SOUND
Page 8
AMPLIFIERS
CTs Multi-Channel Series: With CobraNet
CTs 4200USP/CN, CTs 8200USP/CN
INSTALLED SOUND
TM
CobraNet
Capable
FEATURES (input module)
• 100 Mbps Ethernet single-plug solution for CobraNet audio,
and HiQnet™ control and monitoring.
• Analog audio inputs allow CobraNet network audio input,
CobraNet audio backup, or a hardwire emergency override
of CobraNet audio.
• 24 bit digital to analog conversion with 32 bit, floating point
DSP processing.
*Maximum average power in watts at 1kHz at 0.1% THD.
†Constant Voltage full-bandwidth power ratings support 100 Hz to 20 kHz due to automatic high-pass filters.
(for amplifier specifications, see the CTs MultiChannel Series pages)
Connectors:
AUX Connector
Configurable for AUX input, AUX output and
Listen Bus. Listen Bus is also supported
through CobraNet.
Network Connector
The dual RJ45 CobraNet connectors allow
a Primary & Secondary connection to the
100Mb Ethernet network. Should the Primary
connection lose link activity with the network,
the input module will automatically switch to
the Secondary connection to ensure uninterrupted audio and control. The indicators on
the RJ45 connectors display network information concerning the Ethernet and CobraNet
connections.
Indicators:
Preset Indicator
Signals the number of the current preset, if
active, by flashing a series of flashes equal to
the current preset number.
IQ Data Indicator
Flashes when the module receives a valid
command that is addressed to the CTs 4200
USP/CN and CTs 8200USP/CN.
Switches:
Reset/Preset Switch
Used to change presets, restore settings to
factory default or restore all the presets to
the factory defaults. During operation of the
switch, the Data indicator flashes as an aid to
the user. Accessible with a straightened paper
clip through the rear panel, the switch selects
the next user preset if pressed for less than
2 seconds, resets the module to preset “0” if
pressed for more than 2 seconds.
General:
Memory Backup: Non-volatile FLASH memories for backup of run-time parameters, presets, and program storage.
Communications: 100Mb Fast Ethernet conforming to IEEE 802.3.
Overall Audio Performance:
DSP Processing: Two processors, 32 bit,
Floating Point, 724 µs latency.
D/A and A/D Conversion: 24 bit.
Latency:
DSP processing: 1 ms or 1000 µs.
Digital-to-analog conversion: 250 µs.
Analog-to-digital conversion: 250 µs.
Amplifier: 100 µs.
Total: 1.6 ms or 1000 µs.
Dynamic Range: 103 dB typical (A-weighted,
20Hz–20kHz, audio sourced from muted
CobraNet channel).
Distortion: < 0.1% THD+N, 20Hz–20kHz.
Frequency Response: ± 0.5 dB, 20Hz–20kHz.
Input/Output Monitor Accuracy: Typically ±1dB.
Maximum Input Level: + 20 dBu.
Regulatory Certifications
Other Applications
CTs 8200USP/CN Back Panel (note USP/CN CobraNet™ module at top left)
he Crown®CTs 4200USP/CN and CTs 8200USP/CN power amplifiers have an integrated 3rd genera-
T
tion, DSP-based input module. It connects the amplifier to a 100 Mbps Ethernet network allowing it
to be remotely controlled and monitored via System Architect™ software. In addition, the input module
allows the transport of real-time digital audio via CobraNet™ over the same Ethernet network. The
amplifiers connect to a HiQnet™ audio control/monitor network using standard 100 Mbps Ethernet
hardware (switches, Network Interface Cards, and cables). CobraNet™ audio is available over the same
100 Mbps Ethernet network, providing a simple-to-install, single-plug solution for audio distribution,
control, and monitoring.
2/08
139279-2
INSTALLED SOUND
Page 10
AMPLIFIERS INSTALLED SOUND
CDi Series: 2/4/8 Ohm, 70V/100V per channel
CDi 1000, CDi 2000, CDi 4000, CDi 6000
Versatility
FEATURES
• Onboard digital signal processing includes crossovers,
EQ filters, delay, and output limiting.
• Computer connectivity via USB allows fast setup and
configuration with HiQnet™.
*Maximum average power in watts at 1 kHz at 0.5% THD. **With 1% THD. ‡100Vp
Page 11
SPECIFICATIONS
Performance
Output Power: See power charts below.
Voltage Gain at 1kHz:
CDi 1000: 30.5 dB
CDi 2000: 32.9 dB
CDi 4000: 34.2 dB
CDi 6000: 37.1 dB
Frequency Response: +0/–1 dB from 20 Hz to
20 kHz at 1 watt into 4 ohms.
Load Impedance: Safe with all types of loads.
Rated for 2 to 8 ohms in Stereo mode, 4 to 16
ohms in Bridge-Mono mode.
Sensitivity: 1.4V.
Signal to Noise Ratio (below rated 8-ohm
power at 1 kHz): 100 dB (A weighted).
Damping Factor: Better than 500 from 20 Hz to
400 Hz.
Crosstalk: > 70 dB below rated power, 20 Hz to
1 kHz.
Input Stage: Input is electronically balanced and
employs precision 1% resistors.
Input Impedance (nominal): 20 k ohms, balanced; 10 k ohms, unbalanced.
Maximum Input Signal: +22 dBu typical.
AC Line Voltage and Frequency Configurations
Available: 100V, 120V, 220-240V,
50/60 Hz.
AC Line Current:
CDi 1000: 6.8A
CDi 2000: 8.3A
CDi 4000: 10.5A
At Idle: Draws no more than 38 watts.
CDi 6000: 15.3A
At Idle: Draws no more than 180 watts.
Operating Temperature: 0° C to 40° C at 95%
relative humidity (non-condensing).
Output EQ: 8 parametric filters per channel with
adjustable Q, ±15 dB boost/cut. This 8-filter EQ
section can NOT be bypassed. Filters are enabled
individually.
Delay: Up to 50 msec total delay per channel.
Output Limiter: Prevents clipping and protects
loudspeakers. Choice of –3, –6, or –12 dB
threshold per channel.
Presets: 20 presets. 19 are user-definable
Front Panel Controls and Indicators
Level: Detented rotary level control, one per
channel.
Power Switch: On/off switch applies AC power
to the amplifier.
Sel/Prev/Next Buttons: Three buttons near the
LCD screen are used to access menu items and
front panel lockout.
LCD Screen: Backlit liquid crystal display shows
speaker presets and signal processing.
Signal Indicator: Green LED, one per channel,
illuminates when a very low-level signal is present at input.
–10 Indicator: Green LED flashes when output
signal exceeds –10 dB below clip.
–20 Indicator: Green LED flashes when output
signal level exceeds –20 dB below clip.
Ready Indicator: Green LED, one per channel,
illuminates when the amplifier is ready to produce audio.
Clip Indicator: Red LED, one per channel, turns
on at the threshold of audible distortion.
Temp Indicator: Red LED, one per channel,
illuminates under excessive temperature
conditions.
Power Indicator: Blue LED illuminates when the
amplifier has been turned on and has power.
Output Connectors: 4-position barrier strip with
connectors for dual louspeakers or bridge-mono
loudspeaker. Dual connectors work with 2-8
ohm or 70V/100V loads. Bridge-mono connectors work with 4-8 ohm or 140V loads.
HiQnet USB Connector: Type B, connects to a
USB port on a PC.
Protection
CDi-Series amplifiers are protected against
shorted, open or mismatched loads; overloaded power supplies; excessive temperature; chain destruction phenomena; excessive
output current, and input overload damage.
They also protect loudspeakers from input/
output DC, large or dangerous DC offsets and
turn-on/turn-off transients.
Included Accessories
Non-touch cover
Locking level-control knobs.
Construction
Chassis: Steel.
Cooling: Proportional speed fan with front-to-
rear airflow.
Dimensions: EIA Standard 19-in. rack mount
width (EIA RS-310-B), 3.5 in. (8.9 cm) high and
12.25 in. (31.11 cm) deep behind mounting
surface. CDi 6000 is 16.2 in. (41.15 cm) deep.
Input EQ: 6 parametric filters per channel with
adjustable Q, ±15 dB boost/cut. Also adjustable
high and low shelving filters. This 8-filter EQ
section can be bypassed.
Crossover Filters: Highpass and lowpass per
channel. Butterworth 6/12/18/24 dB per octave and
Linkwitz-Riley 24/48 dB per octave. Also includes
±15 dB bandpass gain and polarity control.
he CDi Series of Crown® amplifiers are professional tools designed and built for installed sound
T
applications. The series includes four models which are identical except for output power: CDi
1000, CDi 2000, CDi 4000 and CDi 6000. All are rugged and lightweight, and offer unmatched value
in their class. CDi-Series amplifiers feature an LCD screen with DSP speaker presets. Other features
include a switch-mode universal power supply, useful function indicators, proportional-speed fanassisted cooling, removable Phoenix-style inputs, barrier strip outputs for low-Z or 70V/140V loads,
short-circuit protection and more.
Rear Panel Controls and Connectors
AC Line Connector:
CDi 1K, 2K, 4K: NEMA 5-15P (15A).
CDi 6000: NEMA 6-10P (20A)
IEC C20 (20A).
Input Connector: Two 3-pin removable
Phoenix-type connectors each accept a
balanced line-level input signal.
Note: All measurements apply to all models of CDi
Series amplifiers in stereo mode with 8-ohm loads and
an input sensitivity of 26 dB gain, 1 kHz at rated power
unless other otherwise specified. Specifications for
units supplied outside the U.S.A. may vary slightly at
different AC voltages and frequencies.
5/09 139648-4
INSTALLED SOUND
Page 12
AMPLIFIERS
DSi Series: 2, 4, 8 ohm
DSi 1000, DSi 2000, DSi 4000, DSi 6000
INSTALLED SOUND
One-touch
Performance
FEATURES
• Intuitive front-panel LCD screen, automatic presets for popular
JBL speaker systems for quick, easy configuration.
• Onboard digital signal processing includes crossovers, EQ filters,
delay, and output limiting.
• Computer connectivity via USB allows fast setup and configuration with HiQnet™.
Maximum average power in watts at 1 kHz at 0.5% THD. *With 1% THD. †Not rated for 100V versions.
Page 13
SPECIFICATIONS
Performance
Voltage Gain at 1kHz:
DSi 1000: 30.5 dB
DSi 2000: 32.9 dB
DSi 4000: 34.2 dB
DSi 6000: 37.1 dB
Frequency Response: +0/–1 dB from 20 Hz
to 20 kHz at 1 watt into 4 ohms.
Load Impedance: Safe with all types of loads.
Rated for 2 to 8 ohms in Stereo mode, 4 to
16 ohms in Bridge-Mono mode. DSi 1000
A1 (100V version) is rated for 4 to 8 ohms in
Stereo mode, 8 to 16 ohms in Bridge-Mono
mode.
Signal to Noise Ratio (below rated 8-ohm
power at 1 kHz):
100 dB (A weighted).
Damping Factor: Better than 500 from 20 Hz
to 400 Hz.
Crosstalk: > 70 dB below rated power, 20 Hz
to 1 kHz, A-weighted.
Input Stage: Input is electronically balanced
and employs precision 1% resistors.
Input Impedance (nominal): 20 k ohms,
balanced; 10 k ohms, unbalanced.
AC Line Voltage and Frequency
Configurations Available: 100V, 120V, 220-
240V, 50/60 Hz.
AC Line Current:
CDi 1000: 6.8A
CDi 2000: 8.3A
CDi 4000: 10.5A
At Idle: Draws no more than 38 watts.
CDi 6000: 15.3A
At Idle: Draws no more than 180 watts.
Operating Temperature: 0° C to 40° C at
95% relative humidity (non-condensing).
DSP Section
Input EQ: 6 parametric filters per channel
with adjustable Q, ±15 dB boost/cut. Also
adjustable high and low shelving filters. This
8-filter EQ section can be bypassed.
Crossover Filters: Highpass and lowpass
per channel. Butterworth 6/12/18/24 dB per
octave, Linkwitz-Riley 24/48 dB per octave.
Also includes ±15 dB bandpass gain and
polarity control.
Output EQ: 8 parametric filters per channel
with adjustable Q, ±15 dB boost/cut. This
8-filter EQ section can NOT be bypassed.
Filters are enabled individually.
Output Limiter: Prevents clipping and
protects loudspeakers. Choice of –3, –6, or
–12 dB threshold per channel.
Delay: Up to 50 msec total delay per channel.
Presets: 20 presets. One is “DSP OFF.”
Fifteen are factory-set for JBL Cinema
systems. Four are user-definable.
Front Panel Controls and Indicators
Level: Detented rotary level control, one per
channel.
Power Switch: On/off switch applies AC
power to the amplifier.
Sel/Prev/Next Buttons: Three buttons near
the LCD screen are used to access menu
items and front panel lockout.
LCD Screen: Backlit liquid crystal display
shows speaker presets and signal processing.
Signal Indicator: Green LED, one per
channel, illuminates when a very low-level
signal is present at input.
–10 Indicator: Green LED flashes when
output signal exceeds –10 dB below clip.
–20 Indicator: Green LED flashes when
output signal level exceeds –20 dB below clip.
Ready Indicator: Green LED, one per
channel, illuminates when the amplifier is
ready to produce audio.
Clip Indicator: Red LED, one per channel,
turns on at the threshold of audible distortion.
Temp Indicator: Red LED, one per channel,
illuminates under excessive temperature
conditions.
Power Indicator: Blue LED illuminates when
the amplifier has been turned on and has
power.
Rear Panel Controls and Connectors
AC Line Connector:
DSi 1K, 2K, 4K: NEMA 5-15P (15A).
DSi 6000: NEMA 6-10P (20A)
IEC C20 (20A).
Input Connector: Two 3-pin removable
Phoenix-type connectors each accept a
balanced line-level input signal.
Output Connectors: 4-position barrier strip
with connectors for dual louspeakers or
bridge-mono loudspeaker.
HiQnet USB Connector: Type B, connects to a
HiQnet network.
HD-15 Connector: For cinema I/O
compatibility with DSi-8M System Monitor.
See Figure 1.
Protection
DSi-Series amplifiers are protected against
shorted, open or mismatched loads;
overloaded power supplies; excessive
temperature; chain destruction phenomena;
excessive output current, and input overload
damage. They also protect loudspeakers
from input/output DC, large or dangerous DC
offsets and turn-on/turn-off transients
Construction
Chassis: Steel.
Cooling: Proportional speed fan with front-to-
rear airflow.
Dimensions: EIA Standard 19-in. rack mount
width (EIA RS-310-B), 3.5 in. (8.9 cm)
high and 12.25 in. (31.11 cm) deep behind
mounting surface. DSi 6000 is 16.2 in. (41.15
cm) deep.
Note: All measurements apply to all models of CDi
Series amplifiers in stereo mode with 8-ohm loads and
an input sensitivity of 26 dB gain, 1 kHz at rated power
unless other otherwise specified. Specifications for
units supplied outside the U.S.A. may vary slightly at
different AC voltages and frequencies.
ngineered from the ground up for unmatched quality and performance, the Crown® DSi
E
Series of power amplifiers offers four models of 500W, 800W, 1200W and 2100W per
channel at 4 ohms. Onboard digital signal processing includes crossovers, EQ filters, delay
and output limiting. Rear panel HD-15 connector provides easy input/output connectivity
between DSi amplifiers and the new DSi-8M System Monitor. At the touch of a button,
Crown’s DSi cinema amplifiers deliver perfectly matched performance with each awardwinning JBL ScreenArray system, making this the ultimate cinema solution.
Operating Temperature/Humidity: 0° C to 40°
C at 95% relative humidity (non-condensing).
Storage Temperature: –20° C to 85° C.
Front Panel Controls and Indicators
Power Switch: Pushbutton on-off switch.
The power switch does not affect the 24V DC
auxiliary power input.
Input Volume Controls: Microphone/line, four
in 14M, eight in 28M. Detented potentiometers
with knobs.
Tone Controls: Bass and Treble non-detented
potentiometers on each input channel. Bass
±10 dB at 100 Hz, Treble ±10 dB at 10 kHz.
Power Indicator: Blue LED indicates power on.
Input Signal Presence Indicator: Green LED,
one for each input channel, illuminates when
input signal exceeds –24 dBu (line) or –70 dBu
(mic).
Output Signal Presence Indicator: Green LED,
one for each output channel, illuminates when
output signal level exceeds 100 mV.
Clip Indicators: Red LED, one per output
channel. Illuminates at threshold of audible
distortion.
Output Volume Controls: One per output channel. Detented potentiometer with knob.
Back Panel Controls and Connectors
Fuse: Protects the power supply.
AC Power Inlet: Detachable IEC.
Auxiliary Power Input: 2-position terminal strip
for 24 VDC (±10%) backup power. Accepts up
to 10 AWG terminal forks.
Mixer Config Switch: A DIP switch with two
functions:
1. Assigns an input as the priority input for
each output, thereby temporarily muting the
remaining inputs. Muting is activated by contact
closure.
2. Global enable switch for phantom power.
Does not affect RCA inputs. Default position
is off.
Priority Connector: 3-pin Phoenix-type connector allows Input 1 or Input 5 (28M only) to mute
other input signals by contact closure.
Input Routing Switch (28M only): DIP switches
that assign each input signal to each output.
Two switches per input.
Line Out Connector: One 3-pin balanced Phoenix-type connector per output channel. Level
controlled by master volume control.
Input Connectors:
Mic/Line Connector: 3-pin Phoenix-type, balanced, one per input channel.
Dual RCA Input Connector: For stereo music
signals, unbalanced, summed together, two
connectors per input channel.
The tone generator has been omitted. Call
Crown Tech Support if you have a tone generator question.
Mic/line Switch: Selects mic-level or line-level
signals. One switch for each balanced input
Included Accessories
Power cord
Detachable rack ears
Phoenix-type connectors
Spade lugs
Dimensions
EIA Standard 19-inch (48.3-cm) rack mount
width (EIA RS-310-B) with rack ears, 1.7-inch
(4.3-cm) height and 10.7-inch (27.18-cm) depth
behind the mounting surface.
Weight
Net Weight:
14M: 8.7 lb (3.9 kg)
28M: 8.7 lb (3.9 kg)
Shipping Weight:
14M: 14 lb (6.4 kg)
28M: 14 lb (6.4 kg)
Regulatory Certifications
he Crown® 14M and 28M are high-value mixers for commercial and industrial audio. The mixers
T
are part of Crown’s Commercial Audio Series, which also includes mixer-amplifiers and power
amplifiers. These low-cost units provide all necessary features in a simple building-block format. Some
applications include schools, hospitals, factories, restaurant/retail, houses of worship, fitness facilities,
A/V boardrooms, correctional facilities, and small offices. Typical uses are paging, background music,
security and evacuation instructions. Input routing allows each input to be assigned to any output. You
can add more mixers for more inputs, or add more power amps (or mixer-amps) to handle more zones.
Other features include priority muting and phantom power.
12/07 138119-1D
COMMERCIAL AUDIO
Page 18
COMMERCIAL AUDIO AMPLIFIERS
180A, 280A, 1160A
Power Zone
FEATURES
• Ideal for commercial and industrial use.
• Balanced Phoenix-type line inputs; touch-proofed screw-terminal
speaker outputs.
• Advanced protection system includes output current limiting,
DC protection, circuit breaker/fuse, and thermal protection.
Operating Temperature/Humidity: 0° C to 40°
C at 95% relative humidity (non-condensing).
Storage Temperature: –20° C to 85° C.
Front Panel Controls and Indicators
Power Switch: Pushbutton on-off switch.
The power switch does not affect the 24V DC
auxiliary power input.
Power Indicator: Blue LED indicates power on.
Output Signal Presence Indicator: Green LED,
one for each output channel, illuminates when
output signal level exceeds 100 mV (45 dB
below full power) from the 4-ohm tap.
Clip Indicators: Red LED, one per output
channel. Illuminates at threshold of audible
distortion.
Master Volume Controls: One per output channel. Detented potentiometer with knob.
Tone Controls: Bass and Treble non-detented
potentiometers on each channel. Bass ±10 dB
at 100 Hz, Treble ±10 dB at 10 kHz.
Back Panel Controls and Connectors
Reset Switch: Resets the circuit breaker that
protects the power supply. 220/230/240V units
have a fuse instead.
AC Power Inlet: Detachable IEC.
Auxiliary Power Input: 2-position terminal strip
for 24 VDC (±10%) backup power. Accepts up
to 14 AWG terminal forks.
Amplifier Outputs Connectors: One per
channel, 4-position terminal strip with COM
(Common), 4 ohms, 70V and 100V terminals.
Accepts up to 10 AWG terminal forks. Nontouch cover included.
Output VCA Connector: One for every two channels, 4-pin Phoenix-type connector for two VCA
control lines of +10 VDC and ground. Compatible with Crown 1-VCAP and 4-VCAP modules.
Line Out Connector: One 3-pin balanced Phoenix-type connector per output channel. Post
master, pre-VCA. Level controlled by master
volume control.
Amp Input Connector:
3-pin Phoenix-type, high-impedance balanced,
one per amplifer channel.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
thermal cutout.
DC-Fault Load Protection: Included.
Included Accessories
Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs
Optional Accessories
1-VCAP remote volume control for one channel.
4-VCAP remote volume control for four chan-
nels.
Dimensions
EIA Standard 19-inch (48.3-cm) rack mount
width (EIA RS-310-B) with rack ears, 3.5-inch
(8.9-cm) height and 12.2-inch (31.0-cm) depth
behind the mounting surface (not including nontouch cover). 4.1 inches (10.5 cm) high including feet. 13.9 inches (35.2 cm) deep from front
of knobs to back of non-touch cover.
Weight
Net Weight:
180A: 21.0 lb (9.5 kg)
280A: 25.3 lb (11.5 kg)
1160A: 25.3 lb (11.5 kg)
Shipping Weight:
180A: 26.0 lb (11.8 kg)
280A: 30.3 lb (13.7 kg)
1160A: 30.3 lb (13.7 kg)
Regulatory Certifications
he Crown®180A, 280A and 1160A are high-value amplifiers for commercial and industrial audio.
T
They provide 4-ohm and constant-voltage outputs (70V and 100V). The amps are part of Crown’s
Commercial Audio Series, which also includes mixers and mixer-amps. These low-cost units provide
all necessary features in a simple building-block format.
9/07 138118-2A
COMMERCIAL AUDIO
Page 20
COMMERCIAL AUDIO AMPLIFIERS
660A
6-Channel
FEATURES
• 6 inputs; 6 amplifier output channels.
• Balanced Phoenix-type line inputs; touch-proof screw-terminal speaker
outputs.
• Advanced protection system includes output current limiting,
DC protection, circuit breaker/fuse, and thermal protection.
• Ideal for commercial and industrial use.
POWER OUTPUT*
Model 4-ohm 70V/100V Inputs System Zones
660A 60W 60W 6 Six-zone
*Minimum guaranteed power in watts at 1 kHz with 0.5% THD.
Page 21
SPECIFICATIONS
Frequency Reponse (at 1 watt from 4-ohm
tap): 100 Hz to 19 kHz +/- 1 dB.
Frequency Response (at line out): 20 Hz to 20
kHz +/- 1 dB.
Signal to Noise Ratio (ref. to rated power,
master volume at minimum): 85 dB.
one for each output channel, illuminates when
output signal level exceeds 100 mV (45 dB
below full power) from the 4-ohm tap.
Clip Indicators: Red LED, one per output
channel. Illuminates at threshold of audible
distortion.
Volume Controls: One per output channel.
Detented potentiometer with knob.
Tone Controls: Bass and Treble non-detented
potentiometers on each channel. Bass ±10 dB
at 100 Hz, Treble ±10 dB at 10 kHz.
Back Panel Controls and Connectors
Reset Switch: Resets the circuit breaker that
protects the power supply. 220/230/240V units
have a fuse instead.
Input Connectors: Detachable 3-pin Phoenixtype, high-impedance balanced, one per channel.
AC Power Inlet: Detachable IEC.
Amplifier Outputs Connectors: One per
channel, 4-position terminal strip with COM
(Common), 4 ohms, 70V and 100V terminals
for channels 1-4 and one 4-position terminal
strip (4 ohms, + and – for each channel) for
channels 5 and 6. Accepts up to 10 AWG terminal forks. Non-touch cover included.
VCA Connector: Each pair of channels has a 4pin Phoenix-type connector for two VCA control
lines of +10 VDC and ground. Compatible with
Crown 1-VCAP and 4-VCAP modules.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
thermal cutout.
DC-Fault Load Protection: Included.
Turn On/Turn Off: No thumps or pops.
Included Accessories
Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs
Optional Accessories
1-VCAP remote volume control for one channel.
4-VCAP remote volume control for four channels.
Dimensions
EIA Standard 19-inch (48.3-cm) rack mount
width (EIA RS-310-B) with rack ears, 3.5-inch
(8.9-cm) height and 12.2-inch (31.0-cm) depth
behind the mounting surface (not including nontouch cover). 4.1 inches (10.5 cm) high including feet. 13.9 inches (35.2 cm) deep from front
of knobs to back of non-touch cover.
Weight
Net Weight:
30.3 lb (13.7 kg)
Shipping Weight:
35.3 lb (16.0 kg)
Regulatory Certifications
he Crown® 660A is a very flexible, high-value six-channel amplifier for commercial and industrial
T
audio. It provides 4-ohm and constant-voltage outputs (70V and 100V) on channels 1 through 4,
and 4-ohm outputs on channels 5 and 6. The 660A is a part of Crown’s Commercial Audio Series, which
also includes mixers and mixer-amps. These low-cost units provide all necessary features in a simple
building-block format.
*Minimum guaranteed power in watts at 1 kHz with 0.5% THD.
Page 23
C
rown’s Commercial Audio mixer/amplifiers deliver legendary Crown quality to the commercial audio
industry. These high-value mixer-amplifiers provide both 4-ohm and constant-voltage outputs (70V
restaurant/retail, houses of worship, fitness facilities, A/V boardrooms, correctional facilities, and small
SPECIFICATIONS
Performance
Frequency Reponse (at 1 watt from 4-ohm
tap): 70 Hz to 19 kHz ± 1 dB.
Frequency Response (at line out): 20 Hz to 20
kHz ± 1 dB.
Power Bandwidth (at 4-ohm tap, 2 dB below
maxium 1 kHz power): 50 Hz to 20 kHz with
< 0.5% THD
Signal to Noise Ratio (ref. to rated power,
master volume at minimum): 85 dB.
DC Output Offset: < ±5 mV.
THD: Less than 0.5% at rated power at 1 kHz.
Input Sensitivity (for full output at maximum
gain):
Balanced mic inputs: 3 mV.
Balanced line inputs: 800 mV.
RCA connectors: 400 mV.
Operating Temperature/Humidy: 0° C to 40° C
at 95% relative humidity (non-condensing).
Storage Temperature: –20° C to 85° C.
Front Panel Controls and Indicators
Power Switch: Pushbutton on-off switch.
The power switch does not affect the 24V DC
auxiliary power input.
Input Volume Controls: Microphone/line,
four in 180MA and 1160MA, eight in 280MA.
Detented potentiometers with knobs.
Tone Controls: Bass and Treble non-detented
recessed potentiometers on each input channel. Bass ±10 dB at 100 Hz, Treble ±10 dB at
10 kHz.
Power Indicator: Blue LED indicates power on.
Input Signal Presence Indicator: Green LED,
one for each input channel, illuminates when
input signal exceeds –24 dBu (line) or –70 dBu
(mic).
Output Signal Presence Indicator: Green LED,
one for each output channel, illuminates when
output signal level exceeds 100 mV (45 dB
below full power) from the 4-ohm tap. Does
not respond to signals from the AMP INPUT
connector.
Clip Indicators: Red LED, one per output channel. Illuminates at threshold of audible distortion. Does not respond to signals from the AMP
INPUT connector.
Output Volume Controls: One per output channel. Detented potentiometer with knob.
Back Panel Controls and Connectors
Reset Switch: Resets the circuit breaker that
protects the power supply. 220/230/240V units
have a fuse instead.
AC Power Inlet: Detachable IEC.
Auxiliary Power Input: 2-position terminal strip
for 24 VDC (±10%) backup power. Accepts up
to 14 AWG terminal forks.
Amplifier Outputs Connectors: One per
channel, 4-position terminal strip with COM
(Common), 4 ohms, 70V and 100V terminals.
Accepts up to 14 AWG terminal forks. Nontouch cover included.
Output VCA Connector: 4-pin Phoenix-type
connector for two VCA control lines of +10 VDC
and ground. Compatible with Crown 1-VCAP
and 4-VCAP modules.
Amp Config Switch: A DIP switch with two
functions:
1. Assigns an input as the priority input for
each output, thereby temporarily muting the
remaining inputs. Muting is activated by contact
closure.
2. Global enable switch for phantom power.
Does not affect RCA inputs. Default position
is off.
Priority Connector: 3-pin Phoenix-type connector allows Input 1 or Input 5 (280MA only) to
mute other input signals by contact closure.
Input Routing Switch (280MA only): DIP
switches that assign each input signal to each
output. Two switches per input.
Line Out Connector: One 3-pin balanced Phoenix-type connector per output channel. Post
master, pre-VCA. Level controlled by master
volume control.
The tone generator has been omitted. Call
Crown Tech Support if you have a tone generator question.
Input Connectors:
Mic/Line Connector: 3-pin Phoenix-type, balanced, one per input channel.
Dual RCA Input Connector: For stereo music
signals, unbalanced, summed together, two
connectors per input channel.
Amp Input Connector: 3-pin Phoenix-type,
high-impedance balanced, one per amplifer
channel. Used to link an additional mixer to
the mixer-amplifier. Can be used to connect an
external processor.
Mic/line Switch: Selects mic-level or line-level
signals. One switch for each balanced input.
Link In/Out Switch: Slide switch, one per channel. With the Link Switch IN, any signal applied
to the Amp Input connector will be mixed with
the input signal(s). With the Link Switch OUT,
only the signal from the Amp Input Connector
will appear at the amplifier output.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs
Optional Accessories
1-VCAP remote volume control for one channel.
4-VCAP remote volume control for four channels.
Dimensions
EIA Standard 19-inch (48.3-cm) rack mount
width (EIA RS-310-B) with rack ears, 3.5-inch
(8.9-cm) height and 12.2-inch (31.0-cm) depth
behind the mounting surface (not including nontouch cover). 4.1 inches (10.5 cm) high including feet. 13.9 inches (35.2 cm) deep from front
of knobs to back of non-touch cover.
Weight
Net Weight:
180MA: 21.0 lbs. (9.5 kg).
280MA: 25.3 lbs. (11.5 kg)
1160MA: 25.3 lbs. (11.5 kg)
Shipping Weight:
180MA: 26.0 lbs. (11.8 kg)
280MA: 30.3 lbs. (13.8 kg)
1160MA: 30.3 lbs. (13.8 kg)
Regulatory Certifications
and 100V) for use in a wide range of commercial applications including schools, hospitals, factories,
offices. Easily configured for a range of uses such as paging, background music, security, and evacuation instructions, Crown’s Commercial Audio units are the smart choice for commercial sound.
12/07 137964-2B
COMMERCIAL AUDIO
Page 24
COMMERCIAL AUDIO MIXER-AMPLIFIERS
135MA, 160MA
Practical
FEATURES
• 3 inputs and one 35W amplifier output channel in 135MA.
• 4 inputs and one 60W amplifier output channel in 160MA.
• Ideal for paging, background music, and music-on-hold.
*Minimum guaranteed power in watts at 1 kHz with 0.5% THD.
Page 25
C
rown’s Commercial Audio mixer/amplifiers deliver legendary Crown quality to the commercial audio
industry. These high-value mixer-amplifiers provide both 8-ohm and constant-voltage outputs (70V
restaurant/retail, houses of worship, fitness facilities, A/V boardrooms, correctional facilities, and small
SPECIFICATIONS
Performance
Frequency Response (at 1 watt from line out):
50 Hz to 20 kHz ± 1 dB.
19 Hz to 34 kHz +0, –3 dB.
Signal to Noise Ratio (ref. to rated power,
master volume at minimum):
0.8V, Ch. 1 volume at minimum, other channel
volumes at maximum).
Line Output Level (nominal): 1V into 10
kilohms.
Phantom Power: 15 VDC.
AC Line Voltages Available:
Universal Power Supply. Line voltage tolerance
+15%, –20%.
Operating Temperature/Humidity: 0° C to 40°
C at 95% relative humidity (non-condensing).
Storage Temperature: –20° C to 85° C.
Front Panel Controls and Indicators
Power Switch: Pushbutton on-off switch.
Input Volume Controls: Four controls, one per
input. Detented potentiometers with knobs.
Tone Controls: Bass and Treble non-detented
recessed potentiometers under master output
volume control. Bass ±10 dB at 100 Hz, Treble
±10 dB at 10 kHz.
Power Indicator: Blue LED indicates power on.
Input Signal Presence Indicators: Green LED,
one above each channel's input attenuator,
illuminates when input signal exceeds –40 dBu.
Input Signal Clip Indicators: Green LED, one
above each channel's input attenuator, flashes
brightly at threshold of audible distortion.
Output Signal Presence Indicator: Green LED
above master output volume control illuminates
when any input signal exceeds –40 dBu.
Output Signal Clip Indicators: Red LED above
master output volume control flashes brightly at
threshold of audible distortion.
Master Output Volume Control: Detented
potentiometer with knob.
Back Panel Controls, Connectors and
Indicators
AC Power Inlet: Detachable IEC accepts US or
Euro style power cords.
Amplifier Output Connector: 4-position terminal barrier block with COM (Common), 8 ohms,
70V and 100V terminals. Accepts up to 10 AWG
terminal forks. Non-touch cover included.
Preamp Line Out Connector: 3-pin balanced
Phoenix-type for connection to external amplifiers. Level independent of master volume
control.
Input Connector 1: 5-terminal Phoenix connector. 3 terminals for balanced signal, 2 terminals
for priority contact closure, which mutes other
channels when DIP switch 3 is on.
Telephone (MOH) Output Connector: 4-terminal
Phoenix connector (2 terminals for 1W output
to 8-ohm speaker, 2 terminals for 600-ohm
output to PBX music-on-hold port).
MOH Level Control: Trim pot adjusts level for
Music-On-Hold output from Telephone (MOH)
Output Connector.
Amp Configuration DIP Switch: DIP switch
selection for multiple functions.
1. On: Sets CH1 to Mic Input. Off: Sets CH1 to
Line Input.
2. On: Sets CH1 to Normal mode (no priority).
3. On: CH1 priority contact closure mutes other
channels.
4. On: CH1 VOX mutes other channels by sensing signal through Input 1.
5. On: Routes CH1 to MOH output.
6. On: Routes CH2 to MOH output.
7. On: Routes CH3 to MOH output.
8. On: 15V phantom power.
VOX Threshold: Trim pot controls how loud
the voice on CH1 must be before muting other
channels. Can be set for no muting.
Cooling
Convection cooled.
Protection
Included protection mechanisms are current
limiting, over-temperature thermal cutout, and
DC-fault load protection. The unit is protected
against turn-on/turn-off thumps.
Included Accessories
Power cord
Non-touch cover for output connectors
Phoenix-type connectors
Optional Accessories
Part no. IST 600-ohm Isolation Transformer for
Telephone Output or Input 1.
Part no. RM1 single rack mount kit for mounting a single MA unit in a rack.
Part no. RM2 double rack mount kit for mounting two MA units side-by-side in a rack.
Part no. S-Cover 10-pack of security knobs.
Dimensions
Width: Half rack width (9.5 in. or 24.1 cm).
Height (front panel): 3.5 in. (8.9 cm).
Height (including feet): 4.1 in. (10.5 cm).
Depth (front panel to back panel): 12.2 in. (31.0
cm).
Depth (front of knobs to back panel): 13.9 in.
(35.2 cm).
Weight
Net Weight:
135MA: 8 lb 2 oz (3.7 kg).
160MA: 9 lb 7 oz (4.3 kg).
Shipping Weight:
135MA: 10 lb 16 oz (4.9 kg).
160MA: 12 lb 4 oz (5.6 kg).
Regulatory Certifications
and 100V) for use in a wide range of commercial applications including schools, hospitals, factories,
offices. Easily configured for a range of uses such as paging, background music, security, and evacuation instructions, Crown’s Commercial Audio units are the smart choice for commercial sound.
2/08 140498-1
COMMERCIAL AUDIO
Page 26
COMMERCIAL AUDIO MIXER-AMPLIFIERS
140MPA
Music & Paging
FEATURES
• 4 inputs (each with a volume control), one 40W amplifier
output channel.
• Ideal for paging, background music, and music-on-hold.
MOH 1W Phoenix Connector: 3-pin Phoenix
connector for 1W output.
MOH 1V RCA Connector: Two mono RCA connectors for 1V output (in parallel with 600-ohm
connections so they are isolated).
Balanced Input Connector: Detachable 3-pin
Phoenix style connector for balanced line-level
signals, one each for input channels 2-4.
Balanced Input Connector: Detachable 3-pin
Phoenix style connector for balanced mic-level
line-level signals, for input channel 1.
Tel Connector: Transformer-isolated 600-ohm
input, summed into Input 1 for paging from a
telephone system.
Dual RCA Input Connector: For stereo music
signals, unbalanced, summed together, two
connectors per input channel.
Amp Input Connector: 3-pin Phoenix-type,
high-impedance balanced. Used to link an
additional mixer to the mixer-amplifier. Can be
used to connect an external processor.
Mic/line Switch: Selects mic-level or line-level
signal for Input 1.
Phantom Power Switch: Turns phantom power
on or off for Input 1.
VOX Threshold: Trim pot controls how loud the
voice must be before ducking occurs. Can be
set for no ducking.
Link In/Out Switch: Slide switch. When set to
IN, any signal applied to the Amp Input connector will be mixed with the input signal(s). When
set to OUT, only the signal from the Amp Input
Connector will appear at the amplifier output.
Priority Connector: 3-pin Phoenix-type connector for push-to-talk mic contact closure. Input
1 is the priority input for the amplified output,
so Input 1 ducks the other inputs. Threshold of
activation depends on input voltage. Ducking
does not affect MOH outputs.
Active Indicator: Illuminates when VOX ducking
is active.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
thermal cutout.
DC-Fault Load Protection: Included.
Turn On/Turn Off: No thumps or pops.
Included Accessories
Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs
Optional Accessories
1-VCAP remote volume control
Dimensions
Width (without rack ears): 17.3 in. (43.8 cm).
Width (with rack ears): EIA Standard 19 in. W
(EIA RS-310-B).
Height (front panel): 3.5 in. (8.9 cm).
Height (including feet): 4.1 in. (10.5 cm).
Depth (front panel to back panel): 12.2 in. (31.0
cm).
Depth (front of knobs to back of non-touch
cover): 13.9 in. (35.2 cm).
Weight
Net Weight:
17 lb (7.7 kg).
Shipping Weight:
22 lb (9.98 kg).
Regulatory Certifications
1/06139430-1
he Crown® 140MPA is a high-value mixer-amplifier for commercial audio. It provides 4-ohm and
T
constant-voltage outputs (25V and 70V). Typical uses are paging, background music, and musicon-hold. The unit provides 4 inputs (each with a volume control) and a 40W amplifier output. Other
features include priority ducking, phantom power, and capability for remote volume control. Multiple
units can be linked.
COMMERCIAL AUDIO
Page 28
COMMERCIAL AUDIO XM TUNER-MIXER-AMPLIFIERS
180MAx Pack (180MAx tuner-mixer-amplifier also available separately)
XM Enabled
FEATURES
• Programmable XM tuner with XM channel data display.
• Independent bass and treble controls for each input.
XM Tuner Scroll Knob: Lets you scroll through
channels and select them.
XM Tuner Display: LCD screen displays XM
channel data (channel number, channel name,
artist name, song title), 16 station presets and
signal strength.
Power Indicator: Blue LED indicates power on.
Input Signal Presence Indicator: Green LED
illuminates when input signal exceeds –24 dBu
(line) or –70 dBu (mic).
Output Signal Presence Indicator: Green LED,
illuminates when output signal level exceeds
100 mV (45 dB below full power) from the
4-ohm tap.
Clip Indicator: Red LED on output illuminates at
threshold of audible distortion.
Output Volume Control: Detented potentiometer
with knob.
Back Panel Controls, Connectors and
Indicators
Reset Switch: Resets the circuit breaker that
protects the power supply.
MOH 1V Level Control: Trim pot adjusts level
for Music-On-Hold 1V output.
MOH 1W Level Control: Trim pot adjusts level
for Music-On-hold 1W output.
MOH Signal Presence Indicator: Flashes when
MOH signal is present.
MOH Source Switch: Switches between Input 3
or XM, and routes the source to MOH 1V Line
Out and MOH 1W connectors.
MOH 1W Select Switch: Feeds 1W MOH signal
either to amplifier output or internal speaker.
MOH 1V Line Output RCA Connectors: Two
RCA connectors (mono) for 1-volt output (in
parallel with 600-ohm connectors, so they are
isolated).
MOH 1W Line Output Connector: 3-pin Phoenix
connector provides Music-On-Hold signal of
approximately 1 watt.
MOH 1V Line Output Phoenix Connector: 3-pin
Phoenix connector, 600-ohm transformer-isolated output, provides Music-On-Hold signal of
approximately 1 volt.
Phantom Power Switch: Turns phantom power
on or off for Input 1.
Mic/line Switch: Selects mic-level or line-level
signal for Input 1.
Link In/Out Switch: Slide switch. When set to
IN, any signal applied to the Amp Input connector will be mixed with the input signal(s); when
set to OUT, only the signal from the Amp Input
Connector will appear at the amplifier output.
Amplifier Output Connectors: 4-position
terminal strip with COM (Common), 4 ohms,
25V and 70V terminals. Accepts up to 10 AWG
crimp-on terminal forks. Non-touch cover
included.
XM Radio Stereo Line Out Connector: Dual
RCA jacks for stereo music out from XM Radio
tuner.
Preamp Line Out Connector: 3-pin balanced
Phoenix-type connector. Post master, pre-VCA.
Level controlled by master volume control.
Output VCA Connector: 3-pin Phoenix-type
connector for two VCA control lines of +10 VDC
and ground. Compatible with Crown 1-VCAP
module.
Priority Connector: 3-pin Phoenix-type connector for push-to-talk mic switch. Contact closure
activatges ducking. Ducking does not affect
Music-On-Hold outputs or XM stereo line out.
Active Indicator: LED illuminates when VOX
ducking is active.
VOX Threshold: Trim pot adjusts how loud the
voice must be before ducking occurs. Can be set
for no ducking.
Priority Release Control: Trim pot adjusts
release time of VOX ducking.
Line Input Connectors (Inputs 2 and 3 only):
3-pin Phoenix-type, balanced.
Dual RCA Input Connector: For stereo music
signals, unbalanced, summed together, two
connectors per input for inputs 1, 2 and 3.
TEL Input Connector: Transformer-isolated
600-ohm input, summed into Input 1 for paging
from a telephone system.
Amp Input Connector: 3-pin Phoenix-type,
high-impedance balanced. Used to link an
additional mixer to the mixer-amplifier. Can be
used to connect an external processor.
AC Power Inlet: Detachable IEC.
XM Radio Antenna Input: Connects to the XM
antenna cable.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
Power cord
Detachable rack ears
Screws for rack ears
Non-touch cover for output connectors
Phoenix-type connectors
Spade lugs
XM antenna
Remote control
Optional Accessories
1-VCAP remote volume control.
Dimensions
Width (without rack ears): 17.3 in. (43.8 cm).
Width (with rack ears): EIA Standard 19 in. W
(EIA RS-310-B).
Height (front panel): 3.5 in. (8.9 cm).
Height (including feet): 4.1 in. (10.5 cm).
Depth (front panel to back panel): 12.2 in. (31.0
cm).
Depth (front of knobs to back of non-touch
cover): 13.9 in. (35.2 cm).
Weight
Net Weight:
20 lb (9.07 kg).
Shipping Weight:
25lb (11.34 kg)
Regulatory Certifications
1/06 139495-1A
he Crown® 180MAx Pack is the first tuner-mixer-amplifier and loudspeaker system designed for
T
commercial use. It is designed for easy installation. Applications include restaurants, retail stores,
coffee shops and other commercial establishments. The system includes the Crown 180MAx tunermixer-amplifier (also available separately), four JBL® Control® 1ST 2-way loudspeakers with built-in
70V transformers, XM antenna and a wireless remote control. Built into the 180MAx is an XM Radio
tuner that receives satellite radio stations with digital sound quality. The unit also accepts signals from
line, telephone, or microphone (phantom power included). Other features include bass and treble
controls, and priority ducking.
COMMERCIAL AUDIO
Page 30
Page 31
PORTABLE PA
XTi Series
XLS Series
Page 32
AMPLIFIERSPORTABLE PA
XTi Series: World Class
XTi 1000, XTi 2000, XTi 4000, XTi 6000
World-Class
FEATURES
• Computer connectivity via USB allows fast setup and configuration
with HiQnet™.
• Integrated speaker presets with LCD front panel display.
• Extremely versatile, handling a wide range of speaker impedances
and outputs.
• Switch-mode universal power supply.
• Speaker presets for Crossover Frequencies, EQ, Limiting, and Delay.
• All products fill 2U rack spaces and set a new standard in
lightweight amps.
• Speakon® and binding post outputs, XLR inputs and loop-thrus.
XTi 1000: 30.5 dB
XTi 2000: 32.9 dB
XTi 4000: 34.2 dB
XTi 6000: 37.1 dB
Frequency Response: +0/–1 dB from 20 Hz
to 20 kHz at 1 watt into 4 ohms.
Load Impedance: Safe with all types of loads.
Rated for 2 to 8 ohms in Stereo mode, 4 to
16 ohms in Bridge-Mono mode. The XTi 1000
A1 (100V version) is rated for 4 to 8 ohms
Stereo, 8 to 16 ohms Bridge Mono.
Sensitivity: 1.4V
Signal to Noise Ratio (below rated 1 kHz
power at 8 ohms): XTi 1K, 2K, 4K: 100 dB (A
weighted). XTi 6K: 103 dB (A weighted).
Damping Factor: Better than 500 from 20 Hz
to 400 Hz.
Crosstalk: > 70 dB below rated power, 20 Hz
to 1 kHz.
Input Stage: Input is electronically balanced
and employs precision 1% resistors.
Input Impedance (nominal): 20 k ohms, bal-
anced;10 k ohms, unbalanced.
Maximum Input Signal: +22 dBu typical.
AC Line Voltage and Frequency Configura-
tions Available: 100V, 120V, 220-240V
50/60 Hz.
AC Line Current (120VAC amplifier playing
1/8 power pink noise into 4 ohms per ch):
XTi 1000: 6.8A, XTi 2000: 8.3A, XTi 4000:
10.5A; at idle draws no more than 38 watts.
XTi 6000: 15.3A; at idle draws no more than
180 watts.
Operating Temperature: 0° C to 40° C at
95% relative humidity (non-condensing).
DSP Section
Input EQ: 6 parametric filters per channel with
adjustable Q, ±15 dB boost/cut. Also adjustable high and low shelving filters. This 8-filter
EQ section can be bypassed.
Crossover Filters: Highpass and lowpass
per channel. Butterworth 6/12/18/24 dB per
octave. Linkwitz-Riley 24/48 dB per octave.
Also includes ±15 dB bandpass gain and
polarity control.
Delay: For signal alignment of driver; 50 mS
total delay.
Subharmonic Synthesizer: Takes the lowfrequency content of the input signal and
“synthesizes” a new signal that is the same
as the input signal but one octave lower. The
new synthesized signal is then mixed with the
original signal to create the effect.
Output Limiter: Prevents clipping.
Presets: 20 presets, 19 of which are user-
definable.
Front Panel Controls and Indicators
Level: Detented rotary level control, one per
channel.
Power Switch: On/off switch applies AC
power to the amplifier.
Sel/Prev/Next Buttons: Three buttons near
the LCD screen are used to access menu
items and front panel lockout.
Signal Indicator: Green LED, one per channel, illuminates when a very low-level signal
is present at input. May be used for troubleshooting cable runs.
–10 Indicator: Green LED flashes when
output signal exceeds –10 dB below clip.
–20 Indicator: Green LED flashes when
output signal level exceeds –20 dB below clip.
Ready Indicator: Green LED, one per channel, illuminates when the amplifier is ready to
produce audio.
Clip Indicator: Red LED, one per channel,
turns on at the threshold of audible distortion.
Temp Indicator: Red LED, one per channel,
illuminates under excessive temperature
conditions.
Power Indicator: Blue LED illuminates when
the amplifier has been turned on and has
power.
Rear Panel Controls and Connectors
AC Line Connector:
XTi 1K, 2K, 4K: NEMA 5-15P (15A).
XTi 6K: NEMA 6-20P (20A)
IEC C20 (20A)
Input Connector: XLR, one per channel.
Link/Out Connector: Loop-thru signal from
input connector for linking to another amplifier, one per channel.
Output Connectors: Two Neutrik® Speakon
NL4MP (mates with NL4FC) output connectors. Channel-1 Speakon® is wired with Ch. 1
and Ch. 2 outputs for use with optional single
4-conductor cable. Two binding post outputs
(in parallel with Speakon® connectors).
HiQnet USB Connector: Type B, connects to a
HiQnet network.
®
Protection
XTi-Series amplifiers are protected against
shorted, open or mismatched loads; overloaded power supplies; excessive temperature; chain destruction phenomena; excessive
output current, input overload damage; and
high-frequency blowups. They also protect
loudspeakers from input/output DC, large or
dangerous DC offsets and turn-on/turn-off
transients.
Construction
Chassis: Steel.
Cooling: Proportional speed fan with front-to-
rear airflow.
Dimensions: EIA Standard 19-in. rack mount
width (EIA RS-310-B), 3.5 in. (8.9 cm)
high and 12.25 in. (31.11 cm) deep behind
mounting surface. XTi 6000 is 16.2 in. (41.15
cm) deep.
he XTi Series of Crown® amplifiers are professional tools designed and built for portable PA applica-
T
tions. The series includes four models which are similar except for output power: XTi 1000, 2000,
4000 and 6000. All are rugged and lightweight, and offer unmatched value in their class. XTi-Series
amplifiers feature an LCD screen with speaker presets for crossover frequencies, EQ, limiting, delay,
and a subharmonic synthesizer. Other features include a switch-mode universal power supply, useful
function indicators, proportional-speed fan-assisted cooling, XLR inputs, Speakon® and binding-post
outputs, short-circuit protection and more.
12/08 139472-3
P O R TA BL E P A
Page 34
AMPLIFIERSPORTABLE PA
XLS-III Series: Performance and Flexibility
XLS1000, XLS1500, XLS2000, XLS2500
Innovation
FEATURES
• High Performance, Lightweight Class-D amplifier – weighs
less than 11 lbs.
• Integrated PureBand™ Crossover system ensures seamless
transitions from low to high frequency drivers.
• Integrated PeakX™ Limiters provide maximum output while
protecting your speakers.
• XLR, 1/4", RCA Inputs ensure compatibility with any source.
• 1/4" Inputs can be used as loop-thrus to distribute signal to
additional amplifiers.
Crossover (CH1=LPF, CH2=HPF),
Low Pass (both channels LPF),
High Pass (both channels HPF),
Bridge (LPF or HPF).
TM
Peak
Limiters: Channel independent clip
X
limiter designed to provide maximum output
while protecting your loudspeakers.
Indicators
Signal Presence Indicators: Two green LEDs,
one for each channel, illuminate when the
channel’s input signal exceeds –40 dBu.
–10 Indicator: Green LED flashes when
output signal exceeds –10 dB below clip.
–20 Indicator: Green LED flashes when
output signal level exceeds –20 dB below clip.
Clip Indicators: Two red LEDs, one for each
channel, illuminate when the channel’s output
is being overdriven.
Thermal Indicator: Two red LEDs, one
for each channel, illuminate when thermal
compression begins.
Input/Output
Input Connectors: XLR (one per channel),
1/4 inch (one per channel), and RCA (one per
channel). The 1/4 inch inputs can be used
as loop-thrus to distribute signal to multiple
amplifiers.
Output Connectors: Two 4-Pole Speakon
Output Connectors accept 2-pole or 4-pole
®
Speakon
connector is wired for both channels so it can
be used for bridge-mono wiring or for stereo
wiring of two speakers to a single Speakon
connector.
One pair of back-panel binding posts per
channel; accepts banana plugs or bare wire.
(European models do not accept banana plugs.)
connectors. The top Speakon
®
Protection
XLS Series amplifiers provide extensive
protection and diagnostic capabilities,
including output current limiting, DC
protection, circuit breaker, and thermal
protection.
Construction
Ventilation: Flow-through ventilation from
front to back.
Cooling: Internal heat sinks with forced-air
cooling for rapid, uniform heat dissipation.
Air Volume Requirements
(per minute per unit): 80.15 ft³ (2.27 m³).
XLS1000: 8.6 lb (3.9 kg)
XLS1500: 8.6 lb (3.9 kg)
XLS2000: 10.75 lb (4.9 kg)
XLS2500: 10.75 lb (4.9 kg)
Shipping Weight:
XLS1000: 13.6 lb (6.2 kg)
XLS1500: 13.6 lb (6.2 kg)
XLS2000: 15.75 lb (7.1 kg)
XLS2500: 15.75 lb (7.1 kg)
Regulatory Certifications
Other Applications
ake command of center stage with Crown's new XLS amplifiers. The high-
T
performance class-D amplifier combined with its integrated PureBand™ Crossover
System deliver unmatched performance and sound; while its multiple inputs let
you plug in anything you want. PeakX™ Limiters effortlessly protect your speaker
investment, and at 11 pounds moving from show to show is nearly effortless.
Powerful, flexible, portable, and reliable – RUN THE SHOW with a power amplifier
designed to play hard all night long.
P O R TA BL E P A
Page 36
AMPLIFIERSPORTABLE PA
XLS Series: Affordable and Reliable
XLS 5000
Evolution
FEATURES
• Housed in a rugged, all-steel 3U chassis.
• Efficient forced-air fan prevents excessive thermal buildup.
• Electronically balanced XLR inputs; touchproof binding
post and Speakon outputs.
• Precision detented level controls, power switch, and four
LEDs, which indicate clip for each channel, power and fault
conditions.
Mode Switch: Back-panel switch selects Dual
or Bridge-Mono mode.
Indicators
Signal Presence Indicators: Two green LEDs,
one for each channel, illuminate when the
channel’s input signal exceeds –40 dBu.
Clip Indicators: Two red LEDs, one for each
channel, illuminate when the channel’s output
is being overdriven.
Power Indicator: Blue LED indicates
amplifier has been turned on and AC power
is available.
Fault Indicator: Two red LEDs, one for each
channel, illuminate when amplifier is in
protect mode. Also illuminates briefly during
normal power-up when amplifier is first
switched on.
Input/Output
Input Connectors: One per channel;
back-panel three-pin female XLR input
connectors.
Output Connectors: Two 4-Pole Speakon
Output Connectors accept 2-pole or 4-pole
®
Speakon
connector is wired for both channels so it can
be used for bridge-mono wiring or for stereo
wiring of two speakers to a single Speakon
connector.
One pair of back-panel binding posts per
channel; accepts banana plugs or bare wire.
(European models do not accept banana
plugs.)
connectors. The top Speakon
®
Protection
Provides extensive protection and diagnostic
capabilities, including output current limiting,
DC protection, circuit breaker, and thermal
protection.
Construction
Ventilation: Flow-through ventilation from
front to back.
Cooling: Internal heat sinks with forced-air
cooling for rapid, uniform heat dissipation.
Air Volume Requirements
(per minute per unit): 80.15 ft³ (2.27 m³).
Dimensions: EIA Standard 19-inch (48.3-cm)
rack mount width (EIA RS-310-B), 5.25-inch
(13.3-cm) height and 15.5-inch (39.5-cm)
depth.
Weight
Net Weight: 62.0 lb (27.7 kg)
Shipping Weight: 74.0 lb (33.6 kg)
Regulatory Certifications
Other Applications
he XLS 5000 power amplifier from Crown represents a new
era in affordable, quality power amplification. It incorporates
T
the best of tried-and-true design principles and innovative
features, all in a rugged, light-weight 3U chassis.
3/08 139436-3B
P O R TA BL E P A
Page 38
Page 39
TOURING
I-Tech HD Series
Macro-Tech i Series
Page 40
AMPLIFIERSTOURING
I-Tech Series: Excellence Without Compromise
I-T4000, I-T6000, I-T8000
Raising the Bar–Again
FEATURES
• BSS OMNIDRIVEHD™ DSP processing with IIR and linear phase FIR filters.
• Global Power Supply designed to deliver maximum power no matter where your
schedule takes you. Universal AC input accepts100-240VAC, 50/60 Hz (±15%).
• High power density, up to 9000 watts in a 2U chassis.
• Highest output voltage in the industry (200V peak) provides clean transient peaks.
• 5th-generation patented Class I (BCA®) circuitry.
• Front-panel USB connector transfers presets to/from a USB drive to the
amp’s DSP.
• True Ethernet backbone–fast, reliable and scalable.
POWER OUTPUT*
20 mS BURST 2-ohm Dual 2-ohm Dual 4-ohm Dual 8-ohm Dual 4-ohm 8-ohm
Model 2-ohm Dual (per ch.)
Common Mode Rejection (CMR) (20 Hz to 1
kHz): > 70 dB typical.
Latency (analog, digital inputs): 1.13 mS analog,
1.81 mS digital (96 kHz).
A/D, D/A Converters: 24-bit 192 kHz Cirrus
Logic.
Digital Input: AES/EBU, 24-bit, 32-96 kHz.
Onboard sample-rate converter.
Network: Onboard TCP/IQ and HiQnet, compatible with standard 100 Mb Ethernet hardware.
DSP: 24-bit conversion with 32-bit, floatingpoint DSP processing. World-class IIR and
linear phase FIR filters. Has 64 assignable filters
with 9 different filter types. Includes all-pass
filters, over 2 seconds of delay available per
channel, and dual uncorrelated-noise and sinewave generators.
Load Impedance: (Note: Safe with all types of
loads) Stereo: 1/2/4/8/16 ohms. Bridge Mono:
2/4/8 ohms.
Input Sensitivity (referenced to 8 ohm rated
output): Adjustable in 0.1V steps from 1.4V to
7.75V.
Required AC Mains: Universal AC input, 100240VAC, 50/60 Hz (±15%). Maximum AC mains
voltage 277VAC.
AC Line Connector: Five cordsets supplied with
amplifier (USA, UK, European, Australia, India).
Front Panel Indicators, Controls and
Connectors
Indicators: Bridge mode, Ready, Signal level,
Clip, Thermal error, Fault, Network data, Power,
AC mains.
LCD Control Screen and Controls: These let
the user adjust the amplifier’s attenuation and
muting, configure the amp, set up and view
error monitoring (such as temperature and load
supervision), set IP and HiQnet addresses from
the front panel, and recall DSP presets. The
presets allow the user to quickly reconfigure the
amp for various applications.
Level Controls (Encoders): Speed-sensitive
rotary encoders, 0.5 dB steps, range 0 to –100
dB. These two knobs affect the Channel-1 and
Channel-2 output levels. They also select Menu
items and adjust parameter values that are
displayed on the LCD Control Screen.
Power Switch: Push-on/push-off switch with
built-in green AC mains present indicator.
USB 2.0 Connector: Accepts a USB drive to
transfer presets from the drive to the amplifier
DSP, and vice versa.
Back Panel Connectors, Controls,
and Indicators
Connectors: Balanced XLR analog inputs, balanced analog XLR loop-thru outputs, AES/EBU
digital input, AES/EBU digital loop-thru output,
4-Pole Speakon output connectors, binding
post output connectors, power cord, EtherCon
Ethernet connector for networking via HiQnet or
CobraNet.
Reset Switch/Circuit Breaker: If the current
draw of the amplifier exceeds safe limits, this
breaker automatically disconnects the power
supply from the AC mains. The switch resets the
circuit breaker.
Preset Indicator: LED flashes to signal the
number of the current preset if active. LED is
green if the preset values have not been changed
once loaded. LED is yellow if the preset values
have been changed since they were loaded.
Dimensions: 19 in. (48.3 cm) W x 3.5 in. (8.9
cm) H x 16.2 in. (41.1 cm) D.
Weight: 28 lbs (12.7 kg) net, 36 lbs (16.3 kg)
shipping.
Included Accessories: Rear rack ears, rack
screws, operation manual, power cords, foam
air filter.
Regulatory Certifications
Other Applications
rown continues the tradition of excellence and innovation with the Crown® I-Tech HD Series,
C
delivering unmatched versatility, power and performance for touring sound applications. Featuring
onboard high-definition BSS OMNIDRIVEHD™ DSP with 24-bit, 192 kHz Cirrus Logic SHARC A/D and
D/A converters, the I-Tech HD Series also offers a new software interface that provides easier systemlevel changes, and includes a configuration wizard. Providing up to 9 kW continuous power in a 2U rack
space and delivering the highest output voltage in the industry, the I-Tech HD Series outperforms all the
competition, even our own.
12/08 141259-1
T O U R I N G
Page 42
AMPLIFIERSTOURING
Macro-Tech i Series: The Legend Continues
Macro-Tech i Series
The Legend Continues
FEATURES
• The Macro-Tech® i Series continues the Crown®Macro-Tech legacy of
unparalleled sonic accuracy and detail, putting sound quality above all else
• Patented, cutting-edge Class-I circuitry gets more power out of an amplifier
with less waste
• Rugged construction ensures that all Macro-Techs are built to withstand
years of abuse on the road
• Global Power Supply — designed to deliver maximum power no matter
what country you work in
• Built-in load, line voltage, input and output monitoring
• Standard Ethernet networking via System Architect® lets system operators
monitor and control the amplifier from any location
POWER OUTPUT*
20 mS BURST 2-ohm Dual 2-ohm Dual 4-ohm Dual 8-ohm Dual 4-ohm 8-ohm
Model 2-ohm Dual (per ch.)
Input Sensitivity (referenced to 8 ohm rated
output): 1.4V, 32 dB gain, and 26 dB gain.
Voltage Gain (referenced to 8 ohm rated
output):
MA-5000i: 37.1 dB to 22.2 dB
MA-9000i: 37.9 dB to 23.0 dB
MA-12000i: 39.3 dB to 24.5 dB
Required AC Mains: Universal AC input, 100240VAC, 50/60 Hz (±10%). Maximum AC mains
voltage 264VAC.
AC Line Connector: Five cordsets supplied with
amplifier (USA, UK, European, Australia, India).
Front Panel Controls and Indicators
Bridge Mode Indicator: Amber LED illuminates
when the amplifier is set to Bridge-Mono mode.
Ready Indicator: Green LED, one per channel.
On (bright): Ready.
On (dim): Onset of compression.
Off: Thermal failure.
Signal Indicators: One green LED per channel.
Solid green: Input signal is above –40 dBu.
Bright green: Channel’s output signal has
reached the onset of audible clipping.
Power Indicator: Blue LED indicates amplifier
has been turned on and AC power is available.
The LED will flash when the AC line voltage is
10% above or below the nominal rated value.
Data Indicator: Yellow LED on front panel
indicates network data activity. Data indicator
flashes only when the amplifier is polled for
data, or is polled to see whether it is online
Power Switch: Push-on/push-off switch with
built-in green AC mains present indicator.
Volume Control LED Ring: A ring of green LEDs
around each volume control show the position
of the control. Entire ring flashes when channel
is muted. Can be converted to be a level meter.
Back Panel Controls, Indicators and
Connectors
Power Cord Connector: Detachable 20 amp IEC
inlet. Cord locks with suppliled cord retention
clip. Voltage range is indicated above IEC inlet.
Reset Switch/Circuit Breaker: If the current
draw of the amplifier exceeds safe limits, this
breaker automatically disconnects the power
supply from the AC mains. The switch resets
the circuit breaker.
Output Connectors: Two high-current, 50A
Neutrik® Speakon® NL4MLP (mates with
NL4FC or NL4), one per channel. Ch 1
Speakon® is wired with Ch 1 and Ch 2 outputs
for use with single 4-conductor cable. Two pairs
of high-current, 60A color-coded 5-way binding
posts (for banana plugs, spade lugs or bare
wire).
Analog Input Connectors: A 3-pin female XLR
connector for each channel.
Analog Loop Thru Connectors: Two male XLR
passive analog loop through.
Mode Switch/Indicator: Sets amplifier to
Stereo, Bridge, or Input Y mode. OFF=Stereo,
YEL=Bridge, GRN=Y.
Network Connectors: Two Neutrik
connector accepts RJ-45 type connectors for
HiQnet™ networking. Next to each connector is
a yellow LINK ACT indicator that shows network
activity, and a green 100Mb indicator that shows
a 100Mb network connection.
Data Indicator: Yellow LED on back panel
indicates network data activity. Data indicator
flashes only when the amplifier is polled for
data, or is polled to see whether it is online.
®
Ethercon
Preset Indicator: Green/yellow LED flashes to
signal the number of the current preset. LED is
green if current preset is active, or is yellow if
current preset is modified.
Input Sensitivity Switch: Three-position switch
providing 1.4V, 32 dB, and 26 dB settings for
both channels.
Firmware/Software
Firmware can be updated at www.crownaudio.
com > Support > Downloads.
Software features: Same as PIP-Lite module
(except no Listen Bus): User Presets, Clip Event
Monitor, Input Signal Level Monitor, Output
Signal Level Monitor, Thermal Headroom Level
Monitor, Power/Standby Control, Signal Mute,
Polarity Inverter, Input Signal Fader, Dynamic
Gain Monitors (Ghost Faders), Amplifier
Information, User and Channel Labels, Amplifier
Mode, Amplifier Output Mode, Line Voltage
Monitor, Error Reporting, Auto Standby, Input
Signal Compressor/Limiter, Peak Voltage
Limiter, Average Power Limiter, Clip Eliminator,
Thermal Limiter, Limiter Tie, Load Supervision.
Front Panel: Cast aluminum with integrated
handles.
Dimensions: 19 in. (48.3 cm) W x 3.5 in. (8.9
cm) H x 16.2 in. (41.1 cm) D.
Weight: 28 lbs (12.7 kg) net, 36 lbs (16.3 kg)
shipping.
Protection: Amplifier is protected against
reactive loads, faults and shorts. If one channel
experiences a catastrophic failure, the entire
amplifier will shut down.
Included Accessories: Rear rack ears, rack
screws, operation manual, power cords, foam
air filter.
Regulatory Certifications
Other Applications
4/08 140535-2
he Crown Macro-Tech i Series amplifiers continue the Macro-Tech legacy of unparalleled sonic accu-
T
racy and detail, putting sound quality above all else. Their patented, cutting-edge Class-I circuitry gets
more power out of an amplifier with less waste. Each model features a Global Power Supply designed
to deliver maximum power in any country. The i Series offers studio-quality analog signal processing
with built-in load, line voltage, input and output monitoring. Standard Ethernet networking via System
Architect provides integrated monitoring and control to give system operators access to the system from
any location.
T O U R I N G
Page 44
Page 45
RECORDING &
BROADCAST
D Series
Page 46
AMPLIFIERS RECORDING & BROADCAST
D Series: Long-Term Favorites
D-45, D-75A
Tried & True
FEATURES
• Powerful AB+B class circuitry yields maximum efficiency
with minimum crossover “notch” distortion.
• IOC® (Input/Output Comparator) alerts of any distortion that
exceeds 0.05% to provide proof of distortion-free performance.
• Ultra-low harmonic and intermodulation distortion result
in the best dynamic transfer function in the industry.
• Very low noise and wide dynamic range exceed the
audio specifications for digital compact discs (CDs).
• Convection cooling system dissipates heat through the heat
sinks and chassis for optimal cooling and maintenance-free
operation.
*Maximum average power in watts at 0.1% THD, 1 kHz.
Page 47
SPECIFICATIONS
Performance
Frequency Response: ±0.1 dB from 20 Hz to
20 kHz at 1watt.
Phase Response: +10 to –15 degrees from
20 Hz to 20 kHz at 1 watt.
Signal-to-Noise: 106 dB from 20 Hz to 20
kHz at full bandwidth FTC power.
Total Harmonic Distortion (THD): Less
than 0.001% at full bandwidth FTC power
from 20 Hz to 400 Hz increasing linearly to
0.05% at 20 kHz.
Intermodulation Distortion (IMD): (60 Hz
and 7 kHz 4:1) Less than 0.01% from 0.25
watts to full bandwidth FTC power, and less
than 0.05% from 0.01 to 0.25 watts.
Crosstalk: Greater than 100 dB below full
bandwidth FTC power from 100 Hz to 1 kHz
decreasing linearly to 80 dB at 20 kHz.
Damping Factor: Greater than 400 from DC
to 400 Hz.
Controlled Slew Rate: 6 volts per ms. (Slew
rates are limited to useful levels for ultrasonic/RF protection.)
Voltage Gain:
At the maximum level setting, 8-ohm load,
0.775V input sensititivity.
D-45: 18.3:1 ±3% or 25.2 dB ±0.3 dB.
D-75A: 23:1 ±3% or 27.3 dB ±0.3 dB.
Load Impedance: Safe with all types of loads.
Rated for 4 to 16 ohms in dual mode, and 8
to 16 ohms in bridge-mono mode.
AC Line Voltage and Frequency Configurations Available: 100, 120, 220 and 240VAC
(±10%), 50 to 400 Hz for international units
(depending on the transformer configuration).
North American 120VAC, 60 Hz units are not
convertible and can only be used at the specified voltage and frequency. All units draw 15
watts or less when idle. Maximum AC power
consumption is 150 watts.
Controls
Power: A two-position front panel rotary
on/off switch.
Level: An independent 31-position detented
front panel level control for each channel.
Dual/Mono: The dual/mono jumper is
located inside the amplifier.
Ground Lift: To prevent ground loops, the
chassis and signal grounds are separated
(or “lifted”) by a permanent impedance
installed between them. There is no control
for this feature.
Indicators
Signal Presence: The green front panel
indicator for each channel flashes synchronously with the channel’s output signal to
indicate its presence.
Input/Output Comparator: The red Input/
Output Comparator (IOC) indicator for each
channel flashes if any type of distortion
reaches 0.05%.
Input/Output
Input Connector: A balanced 3-pin female
Neutrik® combination XLR and ¼-inch
(6.35-mm) phone connector for each channel.
Input Impedance: Nominally 20 k ohms, balanced. Nominally 10 k ohms, unbalanced.
Input Sensitivity: Configurable for 26 dB gain
or 0.775 volt sensitivity.
Output Connector: Barrier block terminals
and stereo headphone jack. The headphone
output is unpadded, and in parallel with the
main amplifier outputs.
Output Impedance: Less than 15 milliohms in
series with less than 3 microhenries.
DC Output Offset: 10 millivolts or less.
Output Signal
Dual: Unbalanced, two channel.
Bridge-Mono: Balanced, single channel.
Channel 1 controls are active; channel 2
controls should be turned down.
Protection
Input: The inputs have series resistance that
provides input overload protection. Controlled
slew rate voltage amplifiers protect against
radio frequencies. The AC line is fused to
protect against excessive current draw.
Output: Instantaneous limiting protection for
short circuits, open circuits and mismatched
loads.
Turn-On: Minimum thumps. Power-up is
instantaneous with no program delay.
Construction
Durable black finish on aluminum front panel
with gray suede Lexan insert. Aluminum
chassis provides maximum heat conduction
and minimum weight.
Dimensions: 19-inch (48.3 cm) rack mount
width, 1.75 inches (4.5 cm) high, 8.5 inches
(21.6 cm) deep behind the mounting surface,
and a 0.625-inch (1.6-cm) protrusion in front
of the mounting surface.
Net Weight:
D-45: 8 lb, 11 oz (3.9 kg)
D-75A: 9 lb, 7 oz (4.3 kg).
Shipping Weight:
D-45: 10 lb, 9 oz (4.8 kg)
D-75A: 11 lb, 4 oz (5.1 kg).
Cooling: The amplifier is totally convection
cooled. The entire aluminum chassis acts as
a conductor to dissipate heat. The covers and
front panel extrusion also act as heat sinks.
Much of the unit’s heat is conducted through
the extruded front panel. This design is used
so that front panel contact with the equipment
rack will also dissipate heat.
Regulatory Certifications
Other Applications
he D-45 and D-75A are long-term standards. They are perfect for moderate power applications
T
such as recording or broadcast studio near-field monitoring, video suite audio monitoring, a
recording/broadcast headphone amp or a small paging system. Convection cooled, the highly reliable D Series is protected against shorted, open, mismatched or low-impedance loads.
8/06 136711-1C
RECORDING & BROADCAST
Page 48
Page 49
CINEMA
DSi Series
CTs 2-Channel Series
CTs Multi-Channel Series
Page 50
AMPLIFIERSCINEMA
DSi Series: 2/4/8 Ohm
DSi 1000, DSi 2000, DSi 4000, DSi 6000
One-Touch
Performance
FEATURES
• Intuitive front-panel LCD screen, automatic presets for popular JBL cinema
speaker systems for quick, easy configuration.
• Onboard digital signal processing includes crossovers, EQ filters, delay, and
output limiting.
• Computer connectivity via USB allows fast setup and configuration with
HiQnet™ System Architect® software.
• Rear-panel HD-15 connector provides easy input/output connectivity
between DSi amplifiers and new DSi-8M System Monitor.
Maximum average power in watts at 1 kHz at 0.5% THD. *With 1% THD. †Not rated for 100V versions.
Page 51
SPECIFICATIONS
Performance
Voltage Gain at 1kHz:
DSi 1000: 30.5 dB
DSi 2000: 32.9 dB
DSi 4000: 34.2 dB
DSi 6000: 37.1 dB
Frequency Response: +0/–1 dB from 20 Hz
to 20 kHz at 1 watt into 4 ohms.
Load Impedance: Safe with all types of loads.
Rated for 2 to 8 ohms in Stereo mode, 4 to
16 ohms in Bridge-Mono mode. DSi 1000
A1 (100V version) is rated for 4 to 8 ohms in
Stereo mode, 8 to 16 ohms in Bridge-Mono
mode.
Signal to Noise Ratio (below rated 8-ohm
power at 1 kHz):
100 dB (A weighted).
Damping Factor: Better than 500 from 20 Hz
to 400 Hz.
Crosstalk: > 70 dB below rated power, 20 Hz
to 1 kHz, A-weighted.
Input Stage: Input is electronically balanced
and employs precision 1% resistors.
Input Impedance (nominal): 20 k ohms,
balanced; 10 k ohms, unbalanced.
AC Line Voltage and Frequency
Configurations Available: 100V, 120V, 220-
240V, 50/60 Hz.
AC Line Current:
CDi 1000: 6.8A
CDi 2000: 8.3A
CDi 4000: 10.5A
At Idle: Draws no more than 38 watts.
CDi 6000: 15.3A
At Idle: Draws no more than 180 watts.
Operating Temperature: 0° C to 40° C at
95% relative humidity (non-condensing).
DSP Section
Input EQ: 6 parametric filters per channel
with adjustable Q, ±15 dB boost/cut. Also
adjustable high and low shelving filters. This
8-filter EQ section can be bypassed.
Crossover Filters: Highpass and lowpass
per channel. Butterworth 6/12/18/24 dB per
octave, Linkwitz-Riley 24/48 dB per octave.
Also includes ±15 dB bandpass gain and
polarity control.
Output EQ: 8 parametric filters per channel
with adjustable Q, ±15 dB boost/cut. This
8-filter EQ section can NOT be bypassed.
Filters are enabled individually.
Output Limiter: Prevents clipping and
protects loudspeakers. Choice of –3, –6, or
–12 dB threshold per channel.
Delay: Up to 50 msec total delay per channel.
Presets: 20 presets. One is “DSP OFF.”
Fifteen are factory-set for JBL Cinema
systems. Four are user-definable.
Front Panel Controls and Indicators
Level: Detented rotary level control, one per
channel.
Power Switch: On/off switch applies AC
power to the amplifier.
Sel/Prev/Next Buttons: Three buttons near
the LCD screen are used to access menu
items and front panel lockout.
LCD Screen: Backlit liquid crystal display
shows speaker presets and signal processing.
Signal Indicator: Green LED, one per
channel, illuminates when a very low-level
signal is present at input.
–10 Indicator: Green LED flashes when
output signal exceeds –10 dB below clip.
–20 Indicator: Green LED flashes when
output signal level exceeds –20 dB below clip.
Ready Indicator: Green LED, one per
channel, illuminates when the amplifier is
ready to produce audio.
Clip Indicator: Red LED, one per channel,
turns on at the threshold of audible distortion.
Temp Indicator: Red LED, one per channel,
illuminates under excessive temperature
conditions.
Power Indicator: Blue LED illuminates when
the amplifier has been turned on and has
power.
Rear Panel Controls and Connectors
AC Line Connector:
DSi 1K, 2K, 4K: NEMA 5-15P (15A).
DSi 6000: NEMA 6-10P (20A)
IEC C20 (20A).
Input Connector: Two 3-pin removable
Phoenix-type connectors each accept a
balanced line-level input signal.
Output Connectors: 4-position barrier strip
with connectors for dual louspeakers or
bridge-mono loudspeaker.
HiQnet USB Connector: Type B, connects to a
HiQnet network.
HD-15 Connector: For cinema I/O
compatibility with DSi-8M System Monitor.
See Figure 1.
Protection
DSi-Series amplifiers are protected against
shorted, open or mismatched loads;
overloaded power supplies; excessive
temperature; chain destruction phenomena;
excessive output current, and input overload
damage. They also protect loudspeakers
from input/output DC, large or dangerous DC
offsets and turn-on/turn-off transients
Construction
Chassis: Steel.
Cooling: Proportional speed fan with front-to-
rear airflow.
Dimensions: EIA Standard 19-in. rack mount
width (EIA RS-310-B), 3.5 in. (8.9 cm)
high and 12.25 in. (31.11 cm) deep behind
mounting surface. DSi 6000 is 16.2 in. (41.15
cm) deep.
Note: All measurements apply to all models of CDi
Series amplifiers in stereo mode with 8-ohm loads and
an input sensitivity of 26 dB gain, 1 kHz at rated power
unless other otherwise specified. Specifications for
units supplied outside the U.S.A. may vary slightly at
different AC voltages and frequencies.
3/09 139622-3
he Crown® DSi Series of power amplifiers provides onboard digital signal processing
T
including crossovers, EQ filters, delay and output limiting. A rear panel HD-15 connector provides easy input/output connectivity between DSi amplifiers and the new DSi-8M
System Monitor. The intuitive front panel LCD screen guides installers through a setup process—featuring presets for the industry-standard JBL cinema loudspeaker systems—to make
configuration quick and easy. At the touch of a button, Crown’s DSi cinema amplifiers deliver
perfectly matched performance with each award-winning JBL ScreenArray
this the ultimate cinema solution.
®
system, making
C I N E M A
Page 52
AMPLIFIERSCINEMA
DSi-8M: Convenient Monitoring
DSi-8M
Performance
Monitor
FEATURES
• Compact 2-rack unit.
• 8 channels for monitoring processor or amplifier inputs.
• All inputs and outputs are balanced to interface with new cinema processors.
• No level jumps when switching between processor and amplifiers.
• 25-pin D-sub connectors, plus removable terminal blocks and HD-15 for
quick, hassle-free connections.
• Designed to work with bi-amplified sound systems to monitor the high- and
low-frequency outputs from the left, center and right channels.
Page 53
SPECIFICATIONS
Performance
Input Impedance (processor inputs): 10 kilohms.
Input Impedance (Processor Inputs): 10 k
ohms.
Input Impedance (Power Amplifiers Inputs):
> 50 k ohms.
Power Requirements: 100-240V , 50-60
Hz, 32 watts.
Front Panel Controls and Indicators
Channel Select Buttons and LEDs: Eight
pushbutton switches, one for each input
channel. Pressing a button monitors the
signal from that channel, and lights the corresponding LED. Any combination of eight
channels can be selected.
Volume Control: Rotary potentiometer with
knob controls the volume of the internal or
external speaker. Has no effect on the VU
Bargraph Meter display.
Processor/Amplifier Selector Switch and
LEDs: Pushbutton switch with corresponding
LEDs selects inputs from cinema procesor or
power amplfiers for monitoring.
VU Bargraph Meter: 12-segment meter
displays input level of selected channels from
–40 VU to +3 VU. May be calibrated by the
rear-panel trim adjustment. Operates independently of the Volume Control.
Test Jack: 1/4" phone jack lets the user monitor the audio output of the DSi-8M. Inserting a mono or stereo 1/4" phone plug here
disables the internal speaker and routes the
audio output to the Test Jack.
Internal Speaker: For convenenient monitoring at the monitor panel.
Power Switch and Power LED: Rocker switch
turns power on or off. LED illuminates when
power is on.
Rear Panel Controls and Connectors
IEC AC Power Receptacle: Connects to an
IEC AC power cord.
Input Connector 1: 10-pin Phoenix terminal
block connects to the power amplifier speaker
outputs for the Left Surround, Right Surround, Back Surround Left, Back Surround
Right and Subwoofer channels. This connector lets you monitor the output of amplifiers
that do not include HD-15 connector options.
Input Connector 2: 10-pin Phoenix terminal
block connects to the power amplifier speaker
output for the Left High, Left Low, Center
High, Center Low, Right High and Right Low
channels. This connector lets you monitor the
output of amplifiers that do not include HD-15
connector options.
Amplifier Level Control: Trimpot adjusts
the level of the input signals from the power
amplifiers.
Processor Level: Trimpot adjusts the level of
the input signals from the processor.
Outputs to Power Amplifier Inputs: The six
HD-15 connectors in this section connect
to DSi amplifiers for both input and output
signals. The HD-15 connectors have two
functions:
1. Connect DSi 8M outputs to DSi amplifier
inputs.
2. Connect DSi amplifier outputs to DSi 8M
inputs for monitoring.
Using VGA cables, the HD-15 connectors can
be connected to Crown DSi power amplifier
HD-15 connectors as described below.
HD-15 Connector 1: For cinema I/O compatibility. Connects to Ls/Rs amplifier.
HD-15 Connector 2: Connects to Bsl/Bsr
amplifier.
HD-15 Connector 3: Connects to Rl/Rh
amplifier.
HD-15 Connector 4: Connects to Sw amplifier.
HD-15 Connector 5: Connects to Ll/Lh
amplifier.
HD-15 Connector 6: Connects to Cl/Ch
amplifier.
Optional Input Connector: 25-pin D-sub
connector connects to the EX output of the
processor.
Bargraph Level: Trimpot adjusts the sensitivity of the front-panel VU Bargraph Meter.
Main Input Connector: 25-pin D-sub connector connects to the main outputs of the
processor.
“EX” Selector Switch: 8-position DIP switch.
Turn on switches 1-4 if system is without EX.
Turn on switches 5-8 if system is with EX.
This routes the correct Ls/Rs inputs to the
DSi-8M circuitry.
Construction
Chassis: Steel.
Dimensions: EIA Standard 19-inch rack
mount width (EIA RS-310-B), 3.5 inches (8.9
cm) high and 9.625 inches (24.4 cm) deep
behind front mounting surface.
Net Weight:
10 lb 2 oz (4.63 kg).
Shipping Weight:
16 lb (7.26 kg).
Regulatory Certifications
he Crown® DSi-8M is a projection booth monitor designed to work with bi-amplified cinema
T
systems using the Crown DSi Series amplifiers. All controls necessary for daily operation of
the DSi-8M are easily accessible on the front panel. 8-channel monitoring allows you to monitor either the processor or the power amplifier’s outputs: L, C, R, Ls, Rs, Bsl, Bsr, and Sub in
any combination. Input levels from the processor and power amplifier can be adjusted independently. There are no huge level jumps when switching between processor and power amplifiers.
The bargraph display can be calibrated to the reference level for your theater. The projectionist
can see auditorium levels instantly.
5/07 139623-2
C I N E M A
Page 54
AMPLIFIERSCINEMA
Other Cinema Products
CTs 2-Channel
FEATURES
• High power density. All two channel models in a
2U chassis.
• New Crown Switching Power Supply for lighter
weight.
• Selectable “Constant-Voltage” or low-impedance
operation per channel.
*Maximum average power in watts at rated THD, 20 Hz - 20 kHz.
rown Cinema Systems employ quality Crown professional amplifiers along with optional amplifier
C
accessories for the best in cinema sound. Crown’s Digital B-Chain system, which provides the first alldigital cinema solution, employs Crown’s CTs Series amplifiers, IQ Networking amplifier modules,
and Crown’s DBC®Network Bridge for the first all-digital cinema solution.
Page 55
AMPLIFIERSCINEMA
Other Cinema Products
CTs Multi-Channel
FEATURES
• High power density: Four-channel model in a 2U
chassis, eight-channel model in a 3U chassis.
• New Crown Switching Power Supply for lighter
weight.
• Selectable “Constant-Voltage” or low-impedance (4/8
ohm) operation per channel-pair.
• 100V direct outputs.
• New “FIT” (Fault Isolation Topology) circuitry isolates
fault conditions without affecting neighboring
channels.
• Accept VCA-MC accessory modules.
POWER OUTPUT*
All channels driven All channel pairs driven
Models 4-ohm Dual 8-ohm Dual 70V Dual 8-ohm Bridge
*Maximum average power in watts at 1kHz at 0.1% THD.
**Constant Voltage full-bandwidth power ratings support 100 Hz to 20 kHz due to automatic
high-pass filters.
Digital Circus, Raleigh, North Carolina, USA.
Note: For more information about the products featured in this section, please refer to the following Crown
sections: CTs 2-Channel, CTs Multi-Channel, XLS Series.
C I N E M A
Page 56
Page 57
NETWORKED PRODUCTS
& ACCESSORIES
PIPs
Accessories
Page 58
NETWORKED PRODUCTSPIPS
TCP / IQ
ANALOG AUDIO INPUTS
PIP LITE
SmartAmp Automation for Networked Audio
he Crown PIP LITE is a PIP (Programmable Input Processor) input
T
module for PIP2 compatible amplifiers. The PIP-LITE connects to an
audio control network via 100 Mb Ethernet. The audio path in the PIP LITE
is processed totally in the analog domain. The SmartAmp™ feature set offers
a range of automation functions which provide greater control over amplifier
operation and helps to save both time and money.
FEATURES
• A Programmable Input
Processor with system
networking capabilities
(connects via 100 Mb
Ethernet).
• Remote control and monitoring
of PIP2-compatible Crown
amplifiers as well as some
PIP1 -compatible amplifiers.*
• Can be connected to the same
network used to transmit
CobraNet™ audio.
• AUX connector configurable
for AUX input, AUX output, or
Listen Bus.
PIP USP3/CN
SmartAmp Automation for TCP/IQ
he Crown PIP-USP3/CN is a 3rd generation DSP-based PIP™
T
(Programmable Input Processor) input module for PIP2 compatible
amplifiers.* It connects the amplifier to a 100 Mb Ethernet network allowing it to be remotely controlled and monitored. In addition, the USP3/CN
allows the transport of real-time digital audio via CobraNet™ over the same
Ethernet network.
The USP3/CN connects to the audio control/monitor network using standard
100 Mb Ethernet hardware (switches, Network Interface Cards, and cables).
CobraNet™ audio is available over the same 100 Mb Ethernet network, providing a simple to install, single plug solution for audio distribution, control,
and monitoring.
The USP3/CN’s SHARC DSP processor gives the user an enormous amount
of digital signal processing. Audio routing, faders, meters, polarity & mute,
input compressors, filters, delays, multimode output limiters, error reporting, and load monitoring are all available. A built-in noise generator and sinewave generator provide noise masking and test capabilities. The enhanced
AUX port capability allows the user to interface with the amplifier to provide
external manual control and monitoring.
FEATURES
• 100 Mb Ethernet single-plug
solution for both CobraNet™
audio and networked control
and monitoring.
• Analog audio inputs allow
audio input to the CobraNet™
network, CobraNet™ audio
redundancy, or a hardwire
emergency override of
CobraNet™ audio.
• Listen Bus amplifier output
monitor via CobraNet™.
• 24 bit digital to analog
conversion with 32 bit, floating
point DSP processing.
• 64 assignable filters with 9
different filter types including
all-pass filters.
• Over 2 seconds of delay
available per channel.
• Input compressors and output
limiters for each channel.
• Dual, uncorrelated noise
generators for noise masking.
• Sine-wave generator.
• Load supervision.
• Full error reporting.
• Firmware upgrades via the
network.
• 10 user selectable presets.
• Reliable FLASH memory
backup of all parameters.
Page 59
PIP USP4
he Crown® PIP-USP4 is a 4th generation DSP-based PIPTM (Programmable
T
Input Processor) input module for CTs Series two channel amplifiers. The
USP4 connects to an Ethernet network allowing it to be remotely controlled
and monitored via System Architect. In addition, the USP4 allows the
transport of real-time digital audio via AES3, CobraNetTM or Ethernet AVB.
The USP4 is a HiQnetTM series component and connects to the audio control/
monitor network using 100Mb* Ethernet hardware (switches, Network
Interface Cards, and cables). The CobraNet or Ethernet AVB audio signal
is available over the same 100Mb* Ethernet network, providing a simple to
install, single plug solution for audio distribution, control, and monitoring.
The USP4’s OMNIDRIVEHD
amount of digital signal processing. LevelMAXTM limiters, proprietary
FIR and IIR filters, audio routing, faders, meters, polarity & mute,
compressors, delays, error reporting and load monitoring are all available.
Built in noise and sine-wave generator provide noise masking and test
capabilities. The enhanced AUX port allows users to interface with the
USP4 to provide additional external control and monitoring.
Offering crisp clear sound and the widest dynamic range possible, the PIPUSP4 provides unprecedented power and flexibility in one compact—and
very affordable—module.
The USP4 can be installed in any CTs two channel amplifier. The USP4
is available in either CobraNet or Ethernet AVB versions for digital audio
transport; with both modules still having integrated AES3 transport.
The USP4 requires Harman Pro System Architect software. The System
Architect software is available at hiqnet.harmanpro.com.
TM
processor gives the user an enormous
FEATURES
• Ultra smooth processing by onboard high-definition
BSS OMNIDRIVEHD DSP with 24-bit,192 kHz Cirrus
Logic SHARC A/D and D/A converters and true 96 kHz
processing
• World-class FIR and IIR filters
• LevelMAX™ peak, RMS and transducer thermal voltage
power limiters combine for a smooth and accurate
response, better sound, and higher usable SPL
• 100Mb Ethernet single-plug solution for CobraNetTM
audio, Ethernet AVB audio, and HiQnetTM control and
monitoring
• Auto Standby for increased energy efficiency
• Multiple Input Options Include: Analog, CobraNetTM or
Ethernet AVB, and AES3 Digital Audio
• Digital Audio On/Off Ramp allows users to send pre
or post processed analog signal out of the module to
adjacent amplifiers
• Amplifier output monitor using the Foldback control
through either CobraNetTM or Ethernet AVB network
• SLM (Sweep Load Monitoring) with system-level
diagnostics
• 64 assignable filters with 9 different filter types including
all-pass filters
• Over 4 seconds of delay available per channel
• Input compressors for each channel
• Full error reporting
• Firmware upgrades via the network
• 50 user selectable presets
• Reliable FLASH memory backup of all parameters
• Ambient Leveler senses the ambient sound level of a
room via the connected loudspeakers
• Over 2 seconds of delay available per channel.
• Input compressors and output limiters for each channel.
• Dual, uncorrelated noise generators for noise masking.
• Sine-wave generator.
• Load supervision.
• Full error reporting.
• Firmware upgrades via the network.
• 10 user selectable presets.
• Reliable FLASH memory backup of all parameters.
N E T W O R K E D P R O D U C T S
Page 60
ACCESSORIES & APPLICATIONS ACCESSORIES
Accessories
VCA-MC4A & VCA-MC8
FEATURES
• Independent remote level control for each channel.
1-VCAP & 4-VCAP
FEATURES
• 1-VCAP provides remote volume control for one
or more CTs amplifier channels.
• Fits into a 1-gang electrical box.
• 4-VCAP provides remote volume control for
four or more CTs amplifier channels.
• Fits into a 2-gang electrical box.
Wall-Mount Controllers
Crown VCAP panels are wall-mounted panels
with potentiometers that provide remote control
of the volume of Crown CTs amplifier channels
via a VCA-MC4 or VCA-MC8 module installed in
the amplifier. Two models are available: 1-VCAP
and 4-VCAP.
1-VCAP: Used in conjunction with a VCA-MC
module, this is a 1-gang panel with one potentiometer that provides remote volume control
for one or more CTs amplifier channels. The
potentiometer on the panel is wired directly
to the VCA connectors on the VCA-MC.
4-VCAP: This is a 2-gang panel with four potentiometers that provide remote volume control
for four or more CTs amplifier channels. The
potentiometers on the panel are wired directly
to the VCA connectors on the VCA-MC.
• 4-pin removable Phoenix-style barrier connectors provide the +10VDC control voltage,
ground, and control lines for two amplifier
channels.
• Optional wall-mount level control panels for use
with VCA modules: 1-VCAP and 4-VCAP.
Remote Level Control
The Crown VCA-MC4A and VCA-MC8 are optional
level-control modules for the Crown CTs multi-channel power amplifiers. The VCA-MC4A is for the CTs
4200, and the VCA-MC8 is for the CTs 8200.
A VCA-MC module provides independent remote
level control for each channel. 4-pin removable
Phoenix-style barrier connectors provide the
+10VDC control voltage, ground, and control lines
for two amplifier channels. Thus, the 4-channel
CTs 4200 uses two connectors; the 8-channel CTs
8200 uses four connectors. Crown CTs 4200 and
8200 amplifiers can be supplied with a VCA-MC
module already factory-installed, or your choice of
MC modules can be easily added to the amplifier
by any authorized Crown Service Center.
Choosing the Right Module
To order accessory modules for your amplifier, please
refer to the model tag (located on the back panel of the
amplifier) for your amplifier’s specific model number.
Then refer to the information below to select the correct
accessory for your requirements.
CTs4200: VCA-MC4 or IQ-MC4
CTs 4200A: VCA-MC4A or IQ-MC4A
CTs 8200 or CTs 8200A: VCA-MC8 or IQ-MC8
Regulatory Certifications
For all CTs Multi-Channel Amp Accessories:
T-170V Constant-Voltage
Transformer
The Crown T-170V is a single
autoformer that provides impedance matching between an amplifier output and “constant voltage”
loudspeakers. It allows amplifiers
without direct 70V or 100V out-
put capability to drive distributed speaker systems
designed to operate at those voltages.
2 INPUTS: COM
3 INPUTS: COM
1 INPUTS: COM
OUTPUTS: COM 70V
70V50V40V
70V50V40V
OUTPUTS: COM 70V
100V
100V
OUTPUTS: COM 70V
4 INPUTS: COM
70V50V40V
70V50V40V
100V
OUTPUTS: COM 70V
100V
TP–170V
TP-170V Constant-Voltage
Transformer Panel
The Crown® TP-170V is a rack-mountable panel
with four autoformers to provide impedance matching between amplifier outputs and “constant voltage” loudspeakers. This unit allows amplifiers without direct 70V or 100V output capability to drive
distributed speaker systems designed to operate
at those voltages. The TP-170V is constructed of
sturdy steel, and hinged on one side to allow easy
access to the inside connections.
Page 61
ACCESSORIES & APPLICATIONS ACCESSORIES
Accessories
cya
(cover your amp)
P.I.P.-CLP
The P.I.P.-C.L.P. is designed to detect and prevent overload. The same error
detecting circuit that is used to signal the IOC indicator is used to activate this
error-driven compressor. It is not a typical signal-driven compressor but a
circuit to prevent an overload. It can yield up to 13 dB of additional signal safety
margin without noticeable program change.
3PLUS3 3+3 Extended Warranty
Crown’s No-Fault, 3+3 Extended Warranty pack-
age extends the terms of your original full warranty for an additional three years, thus covering
years four through six. Available for Crown
amplifiers only.
Commercial Audio Accessories
RM1 Rack-Mounting Kit
The Crown RM1 is a single-unit rack-mounting kit.
It is designed to be used with Commercial Audio
models 135MA and 160MA mixer-amplifiers.
IST Isolation Transformer
The Crown IST is a 600-ohm to 600-ohm isolation
transformer used for telephone connectivity. It is
designed to be used with Commercial Audio models
135MA and 160MA mixer-amplifiers.
RM2 Rack-Mounting Kit
The Crown RM2 is a dual-unit rack-mounting kit.
It is designed to be used with Commercial Audio
models 135MA and 160MA mixer-amplifiers.
S-COVER Security Cover Bulk Pack
The Crown S-COVER is a 10-pack of security cov-
ers. It is designed to be used with Commercial Audio
models 135MA and 160MA mixer-amplifiers.
Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER
of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product
is free of defects in materials and workmanship. We further warrant the new Crown product regardless of the reason for failure, except as excluded in this Warranty
Warranty is only valid within the country in which the product is purchased.
ITEMS EXCLUDED FROM THIS CROWN WARRANTY
This Crown Warranty is in effect only for failure of a new Crown product which occurred within the Warranty Period. It does not cover any product which
has been damaged because of any intentional misuse, accident, negligence, or loss which is covered under any of your insurance contracts. This Crown
Warranty also does not extend to the new Crown product if the serial number has been defaced, altered, or removed.
WHAT THE WARRANTOR WILL DO
We will remedy any defect, regardless of the reason for failure (except as excluded), by repair, replacement, or refund. We may not elect refund unless you
agree, or unless we are unable to provide replacement, and repair is not practical or cannot be timely made. If a refund is elected, then you must make the
defective or malfunctioning product available to us free and clear of all liens or other encumbrances. The refund will be equal to the actual purchase price,
not including interest, insurance, closing costs, and other finance charges less a reasonable depreciation on the product from the date of original purchase.
Warranty work can only be performed at our authorized service centers or at the factory. Warranty work for some products can only be performed at
our factory. We will remedy the defect and ship the product from the service center or our factory within a reasonable time after receipt of the defective
product at our authorized service center or our factory. All expenses in remedying the defect, including surface shipping costs in the United States, will
be borne by us. (You must bear the expense of shipping the product between any foreign country and the port of entry in the United States including the
return shipment, and all taxes, duties, and other customs fees for such foreign shipments.)
HOW TO OBTAIN WARRANTY SERVICE
You must notify us of your need for warranty service within the warranty period. All components must be shipped in a factory pack, which, if needed, may be
obtained from us free of charge. Corrective action will be taken within a reasonable time of the date of receipt of the defective product by us or our authorized service
center. If the repairs made by us or our authorized service center are not satisfactory, notify us or our authorized service center immediately.
DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES
YOU ARE NOT ENTITLED TO RECOVER FROM US ANY INCIDENTAL DAMAGES RESULTING FROM ANY DEFECT IN THE NEW CROWN PRODUCT. THIS INCLUDES
ANY DAMAGE TO ANOTHER PRODUCT OR PRODUCTS RESULTING FROM SUCH A DEFECT. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
WARRANTY ALTERATIONS
No person has the authority to enlarge, amend, or modify this Crown Warranty. This Crown Warranty is not extended by the length of time which you are
deprived of the use of the new Crown product. Repairs and replacement parts provided under the terms of this Crown Warranty shall carry only the unexpired portion of this Crown Warranty.
DESIGN CHANGES
We reserve the right to change the design of any product from time to time without notice and with no obligation to make corresponding changes in products previously manufactured.
LEGAL REMEDIES OF PURCHASER
THIS CROWN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. No action to
enforce this Crown Warranty shall be commenced after expiration of the warranty period.
THIS STATEMENT OF WARRANTY SUPERSEDES ANY OTHERS CONTAINED IN THIS MANUAL FOR CROWN PRODUCTS. 9/07
Page 68
Crown Amplifier Warranty
WORLDWIDE EXCEPT USA & CANADA
SUMMARY OF WARRANTY
Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER
of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship, and we further warrant the new Crown product regardless of the reason for failure, except as excluded in this
Warranty.
Warranty is only valid within the country in which the product is purchased.
1 Note: If your unit bears the name “Amcron,” please substitute it for the name “Crown” in this warranty.
ITEMS EXCLUDED FROM THIS CROWN WARRANTY
This Crown Warranty is in effect only for failure of a new Crown product which occurred within the Warranty Period. It does not cover any product which has been
damaged because of any intentional misuse, accident, negligence, or loss which is covered under any of your insurance contracts. This Crown Warranty also does
not extend to the new Crown product if the serial number has been defaced, altered, or removed.
WHAT THE WARRANTOR WILL DO
We will remedy any defect, regardless of the reason for failure (except as excluded), by repair, replacement, or refund. We may not elect refund unless you
agree, or unless we are unable to provide replacement, and repair is not practical or cannot be timely made. If a refund is elected, then you must make the
defective or malfunctioning product available to us free and clear of all liens or other encumbrances. The refund will be equal to the actual purchase price,
not including interest, insurance, closing costs, and other finance charges less a reasonable depreciation on the product from the date of original purchase.
Warranty work can only be performed at our authorized service centers. We will remedy the defect and ship the product from the service center within a
reasonable time after receipt of the defective product at our authorized service center.
HOW TO OBTAIN WARRANTY SERVICE
You must notify your local Crown importer of your need for warranty service within the warranty period. All components must be shipped in the original box.
Corrective action will be taken within a reasonable time of the date of receipt of the defective product by our authorized service center. If the repairs made by our
authorized service center are not satisfactory, notify our authorized service center immediately.
DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES
YOU ARE NOT ENTITLED TO RECOVER FROM US ANY INCIDENTAL DAMAGES RESULTING FROM ANY DEFECT IN THE NEW CROWN PRODUCT. THIS INCLUDES
ANY DAMAGE TO ANOTHER PRODUCT OR PRODUCTS RESULTING FROM SUCH A DEFECT.
WARRANTY ALTERATIONS
No person has the authority to enlarge, amend, or modify this Crown Warranty. This Crown Warranty is not extended by the length of time which you are
deprived of the use of the new Crown product. Repairs and replacement parts provided under the terms of this Crown Warranty shall carry only the unexpired portion of this Crown Warranty.
DESIGN CHANGES
We reserve the right to change the design of any product from time to time without notice and with no obligation to make corresponding changes in products previously manufactured.
LEGAL REMEDIES OF PURCHASER
No action to enforce this Crown Warranty shall be commenced after expiration of the warranty period.
THIS STATEMENT OF WARRANTY SUPERSEDES ANY OTHERS CONTAINED IN THIS MANUAL FOR CROWN PRODUCTS. 9/07
TRADEMARKS NOTICE: Crown, Crown Audio, Amcron, BCA, IQ, Differoid, DBC, IOC, IQ System, Macro-Tech, ODEP, P.I.P., and VZ are registered trademarks; Digital
B-Chain, Grounded Bridge, Power-Tech, PIP, PIP2, TCP/IQ, IQwic, SmartAmp, IQ2 and XTi are trademarks of Crown International.
Neutrik, Speakon, Windows, Dolby, DTS, HiQnet, CobraNet, ScreenArray, dbx, System Architect, Phoenix and JBL are used for information only and are the property of
their respective companies.
Crown Audio, Inc. reserves the right to make changes in specifications, software, or products without prior notice. Crown Audio, Inc. also assumes no responsibility for any error in type or print reproduction of the features or specifications in this literature. The information provided in this manual was deemed accurate as of
the publication date. However, updates to this information may have occurred. To obtain the latest version of this manual, please visit the Crown website at www.
crownaudio.com.
Some models may be exported under the name Amcron.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.