10/100/1000 MBPS INTELLIGENT REDUNDANT RING
GIGABIT SWITCH WITH OPTIONAL POE+
v1.4 August 17, 2015
The ComNet CNGE2+2SMS[POE][HO] is a four port intelligent switch with light
management functionality. It provides two 10/100/1000Base-T(X) copper ports and
two 100/1000Base-FX SFP ports. The CNGE2+2SMS[POE][HO] provides exclusive
functionality for easy field deployment including DIP switch based operation of
RSTP for creating redundant network topologies as well as preventing network video
flooding of multicast traffic when used in a linear or star topology. Ports 1 and 2 can
optionally supply up to thirty (30) watts of power per port based on the IEEE 802.3at
standard. An optional High Output (HO) version is also available that can supply up
to sixty (60) watts of PoE from ports 1 and 2. This product is fully compatible with the
ComNet exclusive Copperline SFP modules for operation over extended distance UTP
or Coax cable.
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Contents
Regulatory Compliance Statement 3
Warranty 3
Disclaimer 3
Safety Indications 3
Overview 4
Introduction 4
Software Features 4
Hardware Features 4
Hardware Overview 5
Side Panels 5
Indicating LEDs 7
Cables 8
Ethernet Cables 8
10/100/1000BASE-T(X) Pin A ssignments 8
SFP 10
Console Cable 10
DIP Switches 11
WEB Management 15
Configuration by Web Browser 15
About Web-based Management 15
Basic Settings 18
Command Line Interface Management 28
About CLI Management 28
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 2
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Regulatory Compliance Statement
Product(s) associated with this publication complies/comply with all applicable regulations. Please
refer to the Technical Specifications section for more details.
Warranty
ComNet warrants that all ComNet products are free from defects in material and workmanship
for a specified warranty period from the invoice date for the life of the installation. ComNet will
repair or replace products found by ComNet to be defective within this warranty period, with
shipment expenses apportioned by ComNet and the distributor. This warranty does not cover
product modifications or repairs done by persons other than ComNet-approved personnel, and
this warranty does not apply to ComNet products that are misused, abused, improperly installed,
or damaged by accidents.
Please refer to the Technical Specifications section for the actual warranty period(s) of the
product(s) associated with this publication.
Disclaimer
Information in this publication is intended to be accurate. ComNet shall not be responsible for its
use or infringements on third-parties as a result of its use. There may occasionally be unintentional
errors on this publication. ComNet reserves the right to revise the contents of this publication
without notice.
Safety Indications
» The equipment can only be accessed by trained ComNet service personnel.
» This equipment should be installed in secured location.
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 3
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Overview
Introduction
The CNGE2+2SMS is a light managed, hardened Ethernet switch that contains many features.
The switch will work under a wide variety of temperature, dirty and humid conditions. It can be
managed through WEB, USB Console or other third-party SNMP software. With the easy to use
and intuitive web and CLI interfaces, the switch can be easily monitored by a utility called eVision,
which is part of the ComNet eConsole software suite.
eConsole is network management software that is very effective. With easy to use and intuitive
interface, you can easily monitor the status of the switches.
Software Features
» Supports SNMPv1/v2c
» Event notification by SNMP trap and Relay Output (Relay Output for PoE models only)
» Web-based USB Console CLI configuration
» Enable/disable ports
» LLDP (Link Layer Discovery Protocol) support (802.1AB)
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Hardware Overview
Side Panels
The following table describes the ports that are on the sides of the CNGE2+2SMS.
PortDescription
10/100/10 00Base-T(X)
RJ-45 Ethernet ports
SFP Ports2 × 100/1000Base-X SFP
USB ConsoleUse the included mini USB cable to manage the switch.
2 × 10/100/1000Base-T(X) RJ-45 fast Ethernet ports support
auto-negotiation.
Default Settings:
Speed: auto
Duplex: auto
Flow control: disable
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 5
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
1
5
6
234
8
7
CNGE2+2SMS
1. Model name
2. LED for PWR1. When the PWR1 UP, the green LED will be light on
3. LED for PWR2. When the PWR2 UP, the green LED will be light on.
4. LED for STATUS, the green LED will be light on if initialization passed, red for fail.
5. Configuration switches (refer to the switch matrix configuration table on Page 11).
6. 10/100/1000 Base-T(X) Ethernet ports (RJ-45)
7. 100/1000Base-X SFP ports
8. SFP Port Link/Activity LEDs
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 6
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Indicating LEDs
LEDColorStatusDescription
PWR1GreenOnDC power module 1 activated
PWR2GreenOnDC power module 2 activated
STATUSGreenOnInitialization passed
RedOnFailed
10/100/1000Base-T(X) Ethernet ports
LNK /ACTGreenOnPort link up.
BlinkingData transmitted.
1000 Mbps indicatorAmberOnPort speed is 1000 Mbps
SFP
LNK /ACTGreenOnPort link up.
BlinkingData transmitted.
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 7
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
Cables
Ethernet Cables
The CNGE2+2SMS switches have standard Ethernet ports. According to the link type, the switches
use CAT 3, 4, 5, & 5e UTP cables to connect to any other network device (PCs, servers, switches,
routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications
CableTypeMax. LengthConnector
10BASE-TCat. 3, 4, 5 100ΩUTP 100m (328ft)RJ-45
100BA SE-TXCat. 5 100Ω UTPUTP 100m (328ft)RJ-45
1000BASE-TXCat. 5/Cat. 5e 100Ω UTPUTP 100m (328ft)RJ-45
10/100/1000BASE-T(X) Pin Assignments
With 100BASE-T(X)/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3 and 6
are used for receiving data.
10/100 Base-T RJ-45 Pin Assignments
Pin Number Assignment
1TD+
2TD-
3RD+
4Not used
5Not used
6RD-
7Not used
8Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 8
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
1000 Base-T RJ-45 Pin Assignments
Pin Number Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_ DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
The CNGE2+2SMS switches support auto MDI/MDI-X operation. You can use a straight-through
cable to connect PC to switch. The following table below shows the 10/100BASE-T(X) MDI and
MDI-X port pin-outs:
10/100 Base-T MDI/MDI-X pin assignments
Pin NumberMDI port MDI-X port
1TD+ (transmit)RD+ (receive)
2TD- (transmit)RD- (receive)
3RD+ (receive)TD+ (transmit)
4Not usedNot used
5Not usedNot used
6RD- (receive)TD- (transmit)
7Not usedNot used
8Not usedNot used
1000 Base-T MDI/MDI-X pin assignments
Pin NumberMDI port MDI-X port
1BI_DA+BI_DB+
2BI_DA-BI_DB-
3BI_DB+BI _ DA+
TECH SUPPORT: 1.888.678.9427
4BI_ DC+BI_DD+
5BI_DC-BI_DD-
6BI_DB-BI_DA-
7BI_DD+BI _DC+
8BI_DD-BI_DC-
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 9
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
SFP
The Switch has fiber optic ports that utilize SFP connectors. ComNet offers a wide selection of SFP
modules that offer different fiber type, connector type and distances. Please remember that the
TX port of Switch A should be connected to the RX port of Switch B.
Switch A Fiber Cord Switch B
Console Cable
Each CNGE2+2SMS switch can have the initial network settings configured by the management
console port. You can connect them to a PC with USB Ports using the supplied USB to USB Mini B
male plug cable.
USB to USB Mini B Cable
TECH SUPPORT: 1.888.678.9427
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 10
INSTALLATION AND OPERATION MANUAL CNGE2+2SMS[POE][HO]
DIP Switches
The CNGE2+2SMS’s dip switches configure switch features. The DIP Switches are numbered from
left to right when viewing the side of the Switch with the backplate on the bottom and the power
connections on the left. If “Web Management Enable” is selected in the management software
under System Settings, the DIP switch settings will be overridden by any settings made in the
browser interface.
DIP Switch
PositionDescription
1 RSTP enable (down = disabled, up enabled)
2 Port SMS Mux
3 Dual Media Converter
4 Redundant SFP mode
5Reserved for Future Use
6SFP Port 3 speed. Up: 1000M/Down: 100M
7SFP Port 4 speed. Up: 1000M/Down: 100M
Switch Function Listing
The switch functions may be set individually or may be combined in the following order to perform
enhanced functions above the individual operation. The table below describes the operation of the
switch functions. This same table is also available in the help menu of the system webpage.
Summary of the switch configurations (in order of switch priority)
RSTP
(Switch 1)
ONOFFOFFOFFRSTPAll ring configurations
OFFONOFFOFFSMS
OFFONOFFON
SMS MUX
(Switch 2)
DUAL MC
(Switch 3)
R SFP
(Switch 4)
Resulting ModeComment
Port4 is uplink (traffic from
ports 1-3 is sent only to port 4)
SMS with
Redundant SFP
Fiber fail over
with Port1 and Port2 isolation
OFFOFFONOFF
OFFOFFONON
OFFOFFOFFONRedundant SFP
TECH SUPPORT: 1.888.678.9427
Dual Media
Converter
Dual Media
Converter w/
Redundant SFP
Port1->Port3; Port2->Port4
Port1->Port3; Port2->Port4
(with fiber fail over)
Fiber fail over
Port 4 is primary port
INS_CNGE2+2SMS_REV–
02/19/13 PAGE 11