Cobra CPI M400, CPI 400 M Operating Instructions Manual

A1
English
Our Thanks To You
Introduction
Thank you for purchasing the CobraMarine™CPI M400 Power Inverter. Properly used, this product will give you many years of reliable service.
How Your CobraMarine™Power Inverter Works
The CobraMarine™ Power Inverter is an electronic product that has been designed and built to take low voltage DC (Direct Current) power from your boat, RV or automobile by simply connecting the power inverter to the cigarette lighter socket (or connecting directly to other low voltage power supplies) and CONVERT it to standard 115 volt AC (Alternating Current) power like the current you have in your home. This conversion process thereby allows you to use many of your household appliances and electronic products in automobiles, RVs, boats, tractors, trucks and virtually anywhere else.
Customer Assistance
Should you encounter any problems with this product, or not understand its many features, please refer to this owner’s manual. If you require further assistance after reading this manual, Cobra
®
Electronics offers the following customer assistance services:
For Assistance In the U.S.A.
Automated Help Desk English only. 24 hours a day, 7 days a week 773-889-3087 (phone).
Customer Assistance Operators English and Spanish. 8:00 a.m. to 6:00 p.m. CT, Monday through Friday (except holidays) 773-889-3087 (phone).
Questions English and Spanish. Faxes can be received at 773-622-2269 (fax).
Technical Assistance English only. www.cobra.com (on-line: Frequently Asked Questions). English and Spanish. productinfo@cobra.com (e-mail).
For Assistance Outside the U.S.A.
Contact Your Local Dealer
Operating Instructions
Nothing Comes Close To A Cobra
®
English
400 WATT MARINE POWER INVERTER
CPI M400
Printed in China
Part No. 480-075-P
©2003 Cobra®Electronics Corporation
6500 West Cortland Street
Chicago, Illinois 60707 USA
www.cobra.com
Customer Assistance
A2
English
A3
English
Introduction
Our Thanks to You . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A1
Customer Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A1
Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Quick Evaluation Before Installation . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ground Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operation
Turning Your Inverter On or Off . . . . . . . . . . . . . . . . . . . . . . . . . . 13
GFCI Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Power and Protection Indicators . . . . . . . . . . . . . . . . . . . . . . . . . 15
Operating Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Customer Assistance
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Product Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Accessories and Order Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Controls/Indicators and Product Features
Introduction
Table of Contents
Introduction
Features
• GFCI Outlet with Two AC Receptacles
• Conformal Coating*
• Tinned Wiring*
• Automatic Thermal Protection/Shutdown
• Reverse Polarity Protection
• Low Battery Alarm
• Low Battery Shutdown
Positive Battery
Cable Terminal
(Red)
Cooling Fan
Negative Battery
Cable Terminal
(Black)
Ground Terminal
On/Off Power
Switch
Status Indicator
GFCI Outlet
Reset Button (Red)
Status Indicator
Test Button (Black)
* To help resist corrosion
Fuses
1
Nothing comes close to a Cobra
®
Important Safety Information
Before installing and using your CobraMarine™Power Inverter, please read these general precautions and warnings.
Caution and Warning Statements
To make the most of this inverter, it must be installed and used properly. Please read the installation and operating instructions carefully before installing and using it. Special attention must be paid to the CAUTION and WARNING statements in the manual.
CAUTION Statements specify conditions which could cause damage to the unit or other equipment.
WARNING Statements identify conditions that could result in personal injury or loss of life.
General Precautions
1. Never install the inverter in a boat’s engine compartment where gas and battery
fumes are present.
2. Do not operate the inverter if it has been dropped or damaged in any way.
3. Do not open the inverter; it contains no user-serviceable parts. Attempting to service unit could cause electrical shock.
NOTE Internal components remain charged after all power is disconnected.
4. Do not expose the inverter to rain, snow, bilge water or spray.
5. Do not obstruct the ventilation openings.
6. Do not install the inverter in zero-clearance compartment.
CAUTION This inverter should be used in negative ground applications only.
Important Safety Information
Introduction
Continued...
Plug In Directly
3
Nothing comes close to a Cobra
®
2
English
WARNING Power inverters contain components that may produce arcs or sparks. To prevent fire or explosion, do not install the inverter in areas or compartments containing batteries or flammable materials or in locations that require ignition-protected equipment.
WARNING To reduce the risk of fire, do not cover or obstruct the ventilation openings. Do not install inverter in zero-clearance compartment.
Warning: Wash Hands After Handling Power Cord
The power cord on this product contains lead, a chemical known in the state of California to cause birth defects or other reproductive harm.
Caution: Rechargeable Appliances
Certain chargers for small nickel cadmium batteries can be damaged if connected to the CobraMarine™M400 Power Inverter. Two (2) particular types of equipment are prone to this problem:
1. Small battery-operated appliances such as flashlights, razors, and night lights that can be plugged directly into an AC receptacle to recharge.
2. Certain battery chargers for battery packs used in hand power tools. These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals.
This problem does not occur with the vast majority of battery-operated equipment. Most use a separate charger or transformer that is plugged into the AC receptacle and produces a low voltage output. If the label on the AC adapter or charger states that it produces a low voltage AC or DC output (less than 30 volts), the inverter will have no problem powering the adapter safely.
CobraMarine
M400 Output Waveform
The output waveform is referred to as “square wave” or “modified sine wave.” It is a stepped waveform designed to have characteristics similar to the sine wave shape of utility power. A waveform of this nature is suitable for most AC loads (including linear and switching power suppliers used in electronic equipment, transformers and motors). Some very sensitive electronic equipment may not operate satisfactorily on “square wave” or “modified sine wave.”
Ground Fault Circuit Interrupter (GFCI) Outlet
Test the GFCI periodically to make sure it is operating properly (see page 14 for details).
Important Safety Information
Introduction
Important Safety Information
Introduction
Dangerous Voltages
5
Nothing comes close to a Cobra
®
4
English
Quick Evaluation Before Installation
This section provides you with basic information about the inverter and how to check its performance before installation.
Be Sure to Have on Hand:
A 12 volt DC power source (such as a vehicle battery).
The power source must provide between 11 and 15 volts DC and be able to supply enough current to run the test load. As a rough guide, divide the wattage of the test load by 10 to get the current (in amperes) the power source must deliver.
The provided 2 foot cigarette lighter cable.
Only use the cable provided with your inverter. The cigarette lighter cable is suitable for operating the inverter at loads up to 150 watts. Connect by securely inserting the plug into the cigarette lighter socket
CAUTION Do not use the cigarette lighter cable for loads higher than 150 watts. When connecting loads larger than 150 watts, please connect the inverter directly to the battery.
A test load that can be plugged into the AC
receptacle on the inverter for short term testing at a low power level.
Quick Evaluation Before Installation
Introduction
Quick Evaluation Before Installation
Introduction
To Check Your Inverter’s Performance Before Installation:
1. Turn the inverter Off (see page 13 for details). If the power source is a DC power supply, switch it Off as well.
2. Connect cables to Power Input Terminals (see page 8 for details).
3. Connect cable to Power Source (see page 8 for details).
4. Check to make sure all connections are secure.
5. Turn the inverter On. If the power source is a DC power supply, switch it On first.
6. Plug in the test load.
The inverter should supply power to the load. If the inverter is not working properly, refer to the Troubleshooting Guide on page 17 or Power and Protection Indicators section on page 15.
7. Test the GFCI Outlet (see page 14 for details).
Test Load
On/Off Switch to Off
Connect Terminals
Connect Power Source
On/Off Switch to On
Connect Test Load
Test GFCI Outlet
Power Supply
Cables
Mounting
Installation
6
English
7
Nothing comes close to a Cobra
®
Installation Requirements
The inverter must be installed in an area that meets all of the following requirements:
A. Dry
Do not place in an area where water can drip or splash on the inverter.
B. Cool
Ambient air temperature should be between 30°F and 105°F (0°C and 40°C). The cooler the better.
C. Ventilate
Allow at least 1 inch (3 cm) of clearance around the inverter for proper airflow. Make sure that ventilation openings on the ends of the unit are not obstructed.
CAUTION To avoid fire, do not cover or obstruct ventilation openings. Do not install inverter in a zero-clearance compartment. Overheating may result.
CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery.
WARNING This unit contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment.
Mounting
To Mount Your Inverter:
1. Place the inverter on a flat surface with the mounting bracket against the mounting surface.
2. Mount to secure surface using mounting hardware that is corrosion resistant (not included).
The inverter can be mounted horizontally or vertically.
Installation Requirements
Installation
Mounting Brackets
Mounting Hardware
Installation
Connecting Cables
Installation
9
Nothing comes close to a Cobra
®
3. Connect cable to your vehicle’s cigarette lighter socket.
NOTE If the inverter is to be used at levels above 150 watts for extended periods of time, a direct connection to the battery is recommended. Do not use the cigarette cord for loads higher than 150 watts. Please contact your local dealer or customer assistance for the proper cord for direct to battery connections.
8
English
Connecting Cables
Power wire and wiring are very important to the performance of the inverter. Because the inverter has a low voltage, high current input, low resistance wiring is essential between the battery and inverter. This is so it can deliver the maximum amount of energy to the load. Only use the cables provided with your power inverter.
To Connect the Cables Between the Inverter and the Battery:
1. Turn the On/Off Switch on the inverter to the Off position. If the power source is a DC power supply, switch it Off as well.
2. Connect cable to the Power Input Terminals on right side panel of the inverter. The red terminal is positive (+) and the black terminal is negative (-). Insert the ends of the cables onto the terminals and tighten the screws to clamp the cables safely.
Connecting Cables
Turn On/Off Switch to Off
Continued...
Connect Cables
Connect Power Source
11
Nothing comes close to a Cobra
®
Power Consumption
For each piece of equipment you will be operating from the inverter, you must determine the battery’s reserve capacity (how long the battery can deliver a specific amount of current — in automotive batteries, usually 25 amperes) or ampere-hour capacity (a measure of how many amperes a battery can deliver for a specified length of time).
Example – Reserve capacity: a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged.
Example – Ampere-hour capacity: a battery with an ampere-hour capacity of 100 ampere-hours can deliver 5 amperes for 20 hours before it is completely discharged.
To Determine the Battery Ampere-Hour Capacity You Require:
1. Determine how many watts each piece of equipment consumes. This can normally be found on the product label. If only the current draw is given, multiply the current draw by 115 to get the watt consumption.
2. Estimate the time (in hours) that each piece of equipment will be running between battery charging cycles.
3. Calculate the total watt-hours of energy consumption (power x operating time) using the average power consumption and the total estimated running time (in hours).
Power x Operating Time = Watt-Hours.
4. Divide the watt-hours by ten (10) to determine how many power supply’s (12 volt) ampere-hours will be consumed.
10
English
CAUTION Reverse polarity connections (positive to negative) will blow internal fuses in the inverter and may permanently damage the unit. Such damage is not covered by the warranty.
CAUTION Remove any jewelry (watch, ring, etc.). Be careful not to short circuit the battery with any metallic object (wrench, etc.).
WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter. Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection.
Installation
Connecting Cables
Installation
Power Consumption
300 Watts x 15 minutes = 75 Watt-Hours
115 Watts x 3 hours = 345 Watt-Hours
Blender
TV/VCR (up to 25")
100 Watts x 2 hours = 200 Watt-Hours
Laptop
13
Nothing comes close to a Cobra
®
Turning Your Inverter On or Off
Be sure to have your power inverter properly installed before attempting to turn the unit On (see “Installation” page 6).
To Turn the Power Inverter On:
1. If a DC power supply is being used as the power source, switch it On.
2. On the left side panel, switch the On/Off Switch to On.
The inverter is now ready to deliver AC power to your loads. If several loads are to be operated by the inverter, turn them On separately, after the inverter has been turned On. This will ensure that the inverter does not have to deliver the starting currents required for all the loads at once.
To Turn the Power Inverter Off:
1. On the left side panel, switch the On/Off Switch to Off.
NOTE The On/Off Switch turns the control circuit in the inverter On and Off.
It does not disconnect power from the inverter. When the switch is in the Off position, the inverter draws no current
from battery. When it’s in the On position, but no power is being supplied to the load, the inverter draws less than 500 milliamperes from the battery. This is low current draw. It would take more than a week to discharge a 100 ampere-hour battery at this rate depending on the age of the battery.
12
English
Ground Wiring
There is a screw on the rear panel for Chassis Ground. This is to connect the chassis of the inverter to ground.
The Chassis Ground Screw must be connected to a grounding point, which will vary depending on where the unit is installed. Use a #8 AWG copper wire (preferably with green/yellow insulation) to connect the chassis ground screw to the grounding point.
In a Vehicle: Connect the Chassis Ground to the chassis of the vehicle.
In a Boat: Connect to the Boat Grounding System.
In a Fixed Location:
Connect the Chassis Ground Screw to earth ground by connecting to a ground rod (a metal rod pounded into the earth) or other proper service entrance ground.
Installation
Ground Wiring
Chassis Ground
Power On or Off
Operation
On/Off Switch to On
On/Off Switch to Off
15
Nothing comes close to a Cobra
®
If the lamp remains On, or if the Reset Button does not pop out, the unit is defective. Return the inverter to the place of purchase for replacement or service.
4. On the GFCI Outlet, push the Reset Button to return to regular operation.
Power and Protection Indicators
The Power and Protection Indicators include a green/red light and alarm.
Green Light
Power On:
The green light should remain On steady.
Red Light and/or Alarm
Current Overload:
The red light will turn On momentarily, then the inverter will shutdown. The inverter must be turned Off then back On to reset.
Voltage Overload:
The red light will blink and the inverter will shutdown. The inverter must be turned Off then back On to reset.
Temperature Overload:
The red light will turn On momentarily, then the inverter will shutdown. The inverter must be turned Off then back On to reset.
NOTE A momentary sound of the internal alarm and/or flash of the red light is normal at start up.
14
English
Ground Fault Circuit Interrupter (GFCI) Outlet
The AC outlet on your CobraMarine™Power Inverter is a Ground Fault Circuit Interrupter (GFCI). This protects you against hazardous electrical shock that could be caused by dampness, faulty mechanism, worn cables, water spray, etc.
Test the GFCI periodically to make sure it is operating properly.
To Test the GFCI Outlet:
1. Turn the inverter On (see page 13 for details).
2. Plug a test lamp into the outlet.
3. On the GFCI Outlet, press the Test Button.
The Reset Button should pop out and power to the lamp should turn Off.
GFCI Outlet
Power and Protection Indicators
Operation
Test Load
Test Button
Reset Button
On/Off Switch to On
Operation
17
Nothing comes close to a Cobra
®
16
English
Operating Limits
Power Output
The inverter can deliver 400 watts for about 60 minutes. The inverter must cool for 15 minutes before it can resume operation at 400 watts. Note: The wattage rating applies to resistive loads.
The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other motor-operated equipment require very high surge currents to start. The inverter may not be able to start some of these motors even though their rated current draw is within the inverter’s limits. The inverter will normally start single phase induction motors rated at
1
2 HP or less.
Input Voltage
The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 10.5V+/-0.3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below 9.5V+/-0.3V. This protects the battery from being over-discharged. The inverter must be turned Off then back On to reset.
The inverter will also shut down if the input voltage exceeds 15.75V+/-0.75V. This protects the inverter against excessive input voltage. Although the inverter has protection against over-voltage, it may still be damaged if the input voltage was to exceed 16 volts.
Operation
Operating Limits
Troubleshooting Guide
Operation
Troubleshooting Guide
Problem/Symptom
Low output voltage
No output voltage
No output voltage after prolonged use
No output voltage, “Protect” indicator lighted
No output voltage
No power to inverter
Low battery alarm on all the time
Possible Causes
Overload
Low input voltage
Thermal shutdown
High input voltage
Short circuit
Blown fuse
Poor DC wiring
Poor battery condition
Solution
Reduce the load.
Recharge battery. Check connections and cable.
Allow inverter to cool Off.
Reduce load, continuous operation input current required.
Improve ventilation; Make sure ventilation openings in the inverter are not obstructed.
Reduce ambient temperature.
Make sure the inverter is connected to 12V battery.
Check regulation of charging system.
Check load for proper operation.
Replace fuse.
Check connections.
Make sure battery is fully charged.
19
Nothing comes close to a Cobra
®
Limited 1-Year Warranty
For Products Purchased In the U.S.A.
Cobra
®
Electronics Corporation warrants that its CobraMarine™Power Inverter, and the component parts thereof, will be free of defects in workmanship and materials for a period of one (1) year from the date of first consumer purchase. This warranty may be enforced by the first consumer purchaser, provided that the product is utilized within the U.S.A.
Cobra®will, without charge, repair or replace, at its option, defective power inverters, products or component parts upon delivery to the Cobra®Factory Service department, accompanied by proof of the date of first consumer purchase, such as a duplicated copy of a sales receipt.
You must pay any initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra®’s expense, if the product is repaired or replaced under warranty. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.
Exclusions: This limited warranty does not apply: 1) To any product damaged by accident;
2) In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs; 3) If the serial number has been altered, defaced, or removed; 4) If the owner of the product resides outside the U.S.A.
All implied warranties, including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty. Cobra®shall not be liable for any incidental, consequential or other damages; including, without limitation, to damages resulting from loss of use or cost of installation.
Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.
For Products Purchased Outside the U.S.A.
Please contact your local dealer for warranty information.
18
English
Specifications
Continuous output power (1 hour) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400w
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800w
Peak efficiency (12V –
1
2 load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load) . . . . . . . . . . . . . . . . . . . . . . . . . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
Input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0°C – 40°C
(32°F – 104°F)
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C – 85°C
(-40°F – 185°F)
Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overload, short-circuit, overtemp,
reverse polarity, under/over voltage
Notes
All protection must be reset.
To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V.
To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases.
The unit is completely insulated in input and output for added safety.
Specifications
Operation
Warranty
Warranty
21
Nothing comes close to a Cobra
®
4. Pack power inverter securely to prevent damage in transit. If possible, use the original packing material.
5. Ship prepaid and insured by way of a traceable carrier such as United Parcel Service (UPS) or First Class Mail to avoid loss in transit to:
Cobra®Factory Service Cobra®Electronics Corporation 6500 West Cortland Street Chicago, Illinois 60707 USA.
6. If the power inverter is in warranty, upon receipt of your power inverter, it will either be repaired or exchanged depending on the model. Please allow approximately 3 – 4 weeks before contacting Cobra
®
for status. If the power inverter is out of warranty, a letter will automatically be sent informing you of the repair charge or replacement charge.
If you have any questions, please call 773-889-3087 for assistance.
20
English
Maintenance
Very little maintenance is required to keep the inverter operating properly. The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals. Be sure vents and fans are free of dust or debris.
Product Service
If you have any questions about operation or installing your new CobraMarine
product, or if you are missing parts…
Please call Cobra®first! DO NOT RETURN THIS PRODUCT TO THE STORE! See customer assistance on page A1.
If your product should require factory service, please call Cobra®first before sending your power inverter. This will ensure the fastest turn-around time on your repair. You may be asked to send your power inverter to the Cobra®factory.
It will be necessary to furnish the following to have the product serviced and returned.
1. For Warranty Repair include some form of proof-of-purchase, such as a mechanical reproduction or carbon copy of a sales receipt. If you send the original receipt, it cannot be returned.
2. Send the entire product.
3. Enclose a description of what is happening with the power inverter. Include a typed or clearly printed name and address of where the power inverter is to be returned.
Maintenance and Product Service Product Service
Customer AssistanceCustomer Assistance
22
English
Accessories and Order Form
Customer Assistance
Optional Accessories
You can find quality Cobra®products and accessories at your local Cobra®dealer, or in the U.S.A., you can order directly from Cobra®.
Ordering From U.S.A.
Call 773-889-3087 for pricing or visit www.cobra.com.
For credit card orders, complete and return this order form to fax number 773-622-2269. Or call 773-889-3087 (Press 1 from the main menu) 8:00 a.m. to 6:00 p.m. CT, Monday through Friday.
Make check or money order payable to: Cobra®Electronics, Attn: Accessories Dept. 6500 West Cortland Street, Chicago, IL 60707 USA
To order online, please visit our website: www.cobra.com
The Cobra
®
line of quality products includes:
CB Radios microTALK
®
Radios Radar/Laser Detectors Safety Alert
®
Traffic
Warning Systems Accessories GPS (Global
Positioning System) HighGear
Accessories
Name
Address (No P.O. Boxes)
City State/Province Zip Country
Telephone
Credit Card Number Type: ❒ Visa Mastercard Discover Exp. Date
Customer Signature
Item # U.S.Cost Each Qty Amount
U.S. Subtotal
(Tax if Applicable)
Shipping/Handling
Total
Amount Shipping/Handling*
$10.00 or less . . . . . $3.00
$10.01-$25.00 . . . . . $5.50
$25.01-$50.00 . . . . . $7.50
$50.01-$90.00 . . . . $10.50
$90.01-$130.00 . . . $13.50 $130.01-$200.00 . . $16.50
$200.01 plus . . . . 10% off
. . . . . . . . . . . . . . purchase
Tax Table
Ohio, Wisconsin add 5% Indiana, Michigan add 6%
California add 7.25% Illinois add 8.75%
*For AK, HI and PR add
additional $26.95 for FedEx Next Day or $10.95 for FedEx 2nd Day. Excludes weekend and holiday shipments.
Please allow 2-3 weeks for delivery in the U.S. Prices subject to change without notice.
Loading...