Cobra CPP 7500 User Manual

0 (0)
Cobra CPP 7500 User Manual

CPP 7500

User Manual

Portable Power - Anytime, Anywhere!

Thank for purchasing the Cobra CPP 7500 JumPackjump starter portable PowerPack. Before using this product, please read these instructions carefully to learn about the features and capabilities of the JumPack and how you can get the best out of it.

Note: Please charge your CPP 7500 JumPack completely prior to using it for the rst time.

©2014 Cobra Electronics Corp. Part No. 480-936-P Printed in China Version D

IMPORTANT SAFETY INSTRUCTIONS

Charge the JumPack fully prior to use.

WARNING: Keep the unit clear of re and water.

WARNING: Shock Hazard. Keep away from children. Do not insert foreign objects into the jumper cables port/jack, the USB output port, or the DC input jack. Do not expose this product to water, rain, snow, condensation, or spray. Do not open the JumPack to replace the internal battery. No user replaceable parts are inside the JumPack.

WARNING: Explosion Hazard. Do not use this product where there are ammable fumes or gases, such as in the bilge of a gasoline-powered boat, or near propane tanks. Do not use this product in an enclosure containing automotive-type lead-acid batteries.

The jump start cable clamps must be connected positive to positive (red clip to battery (+)) and negative to negative (black clip to battery (-)). A reverse polarity connection (positive to negative) may cause damage to the JumPack and/or create a sparking/explosion hazard.

WARNING: Fire Hazard

Do not crush or puncture the JumPack. Never allow the jump start cables’ red and black clamps’ metal contacts to touch each other or another common metal conductor. This could cause damage to the unit and/or create a re hazard. Always disconnect the jump start cables from the JumPack after each use and store separately. The jump start feature is designed for short term operation only.

Turn the ignition key for no more than 3 seconds at a time. Operating the jump start feature for more than 3 seconds may cause damage to the unit. Allow the JumPack to cool down for at

least 1 minute after each jump start attempt.

.1.

Caution: Operating temperature

Do not expose the JumPack to temperatures over +113° F (+45° C) or under -14° F (-10° C). Using the JumPack at high or low temperatures may reduce the internal battery capacity and shorten the battery life.

Note: In extreme cold weather conditions, please bring the JumPack indoors for best results.

Precautions when working with batteries WARNING: Explosion and re hazard

1.Follow all instructions published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed.

2.Make sure the area around the battery is well-ventilated.

3.Never smoke or allow a spark or ame in the vicinity of the engine or batteries.

4.Be careful not to drop a metal object on the battery or allow a metal tool to simultaneously touch the positive and negative cable ends or battery terminals.

5.Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. Batteries produce a short-circuit current high enough to weld a ring or other similar objects to metal, causing a severe burn.

6. If you need to remove a battery, always remove the negative terminal from the battery rst. Make sure all accessories are off so you don’t cause an arc.

7.Someone should be within range of your voice, or close enough to come to your aid when you work near batteries.

8.Have plenty of fresh water, soap and a supply of baking soda on hand in the area of the batteries in case of contact with battery acid. Baking soda neutralizes lead acid battery electrolyte.

9.The JumPack is supplied with a rechargeable Li-Cobalt battery.

This battery is self-contained and not consumer replaceable. Battery must be disposed of properly when it no longer holds a charge. Proper

charging practices will increase the life of the batteries.For information on battery recycling call toll free 800-822-8837.

.2.

Product:

Battery Status Indicator LEDs

 

Jumper cable with clamps

 

Jump Starter Cable Input

Power/Flashlight/Battery

Capacity Button

 

LED Flashlight/Strobe

14V DC Charge Input

Light/ S.O.S Light

USB 5V/2.1 Amp Output

 

Home adaptor Car adaptor

Operation:

Recharging the JumPack:

The CPP 7500 JumPack can be recharged with the supplied 120V AC wall charger connected to an AC home outlet or with the supplied 13.8V DC vehicle charger.

When the CPP 7500 is charging; the LEDs will show the current battery life. The last LED that is lit will blink to show that the JumPack is charging. When the JumPack is fully charged the LEDs will turn off automatically.

For best battery performance the JumPack should be fully recharged every 3 months.

.3.

Check Battery Capacity:

To check the battery capacity of the JumPack press the Power/Flashlight button on the top of the unit with no device connected. The blue LEDs will show the remaining battery capacity:

Battery Status Indicator LEDs

1LED on: 10%-40% charge

2LEDs on: 40%-65% charge

3LEDs on: 65%-85% charge

4LEDs on: 85%-100% charge

Note: When charging a device the number of lit LEDs may decrease while the JumPack is in use. The battery capacity indicator cannot accurately measure the capacity during rapid charging. To con rm the real battery capacity, disconnect the

device being charged and press the power/ ashlight/capacity button.

.4.

Loading...