Instructions
Before beginning this modification or attempting any maintenance, remove the electrical power and air source from the machine; also, bleed off any stored compressed air by exhausting through the air blast foot valve.
1. Air Unit - Locate hole on back of chassis as shown.
Electric Unit - Drill a 0.221 diameter hole 2-inches
below the ground screw as shown.
Air Unit -Locate Hole Back Of Chassis
Electric Unit
-Drill Hole 2" Below Ground Screw
Bracket Placement
Air Unit
Operation & Maintenance
The separator is equipped with an automatic drain and
should not normally need draining.
The separator has a replaceable filter element that should be changed when it becomes dirty. The element can be accessed by rotating the bowl to the left 45° and pulling down.
Service Parts
Part No. Description
85608058 Filter Bowl
85608057 Filter Element
85000749 Bracket
8106301 Screw
8184256 Elbow Fitting
Bracket Placement
Electric Unit
2. Attach bracket to chassis using screw provided.
3. Install elbow fittings to separator with the hose
barbs pointing down.
4. Remove clamp and fitting from unit inlet hose.
5. Slide new clamp on to hose, slide hose over hose
barb fitting on the right side of separator. Install clamp.
6. Repeat step 5 with the air supply hose, attaching it
to the left side of separator.
7. Place separator assembly into bracket.
8. Electric - Canadian Units Only - Apply supplied
decals (2) on air tank to replace the original decals that are now covered by the separator bracket.
9. Re-connect power sources and check for air leaks.
Correct as needed.
85608056 00 06/12 1 of 1 © Copyright 2012 Hennessy Industries and COATS All Rights Reserved