Classe Audio CAP-151 Service manual

Classé Audio Inc.
Date: Model Number:
August 22, 2007
CAP-151 Service manual
Classé Audio, Inc. 5070 François Cusson Lachine, Québec Canada H8T1B3, www.classeaudio.com
PRO-SVR_LEGACY Page 1 of 14
Table of Contents
Introduction 3 Important Notes on Servicing 3 Ordering Replacement Parts 3 Block Diagrams 4 Start up Procedure 5 Protection Modes and Indicators 6 Troubleshooting Guide 7 Output Transistors Testing and Replacement 8 Calibrations and Adjustments 9 Parts List 10 Updates 11 Fuses 12 Voltage Change 13 IR Interface Information 14 Schematics 15
The contents of this document as well as the files associated with it contain confidential information that is proprietary to Classé Audio Incorporated and are intended solely for the purpose of servicing product. No part of its contents may be used, copied, disclosed, or conveyed to any party in any manner whatsoever without prior written permission from Classé Audio Incorporated.
PRO-SVR_LEGACY Page 2 of 14
Introduction
Please read this manual carefully before commencing servicing! Only qualified and authorized personnel should attempt to service this product.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions.
Classé has a global product support network. For product assistance or to order replacement parts please contact your nearest service center always quoting the unit serial number.
North America Phone: (978) 664-2870 E-mail: classe@bwgroupusa.com
Europe Phone: 44 (0) 1903 221 700 E-mail: classe@bwgroup.com
Asia Phone: (852) 2790 8903 E-mail: classe@bwgroup.hk
Rest of the World Phone: (514) 636-6384 E-mail: cservice@classeaudio.com
Important Notes on Servicing
1. ALWAYS observe ESD precautions when handling electronic modules or PCBAs.
2. NEVER exchange boards with a different revision number, unless authorized by Classé.
3. ALWAYS use Classé original replacement parts. The use of generic parts may void the warranty of
the unit.
Ordering Replacement Parts
There may be a delay in processing incomplete requests. Please be sure to include all required information. Remember to quote the serial number of the unit on all replacement part orders and the Classé order number when returning defective parts for credit.
PRO-SVR_LEGACY Page 3 of 14
Block diagrams
PRO-SVR_LEGACY Page 4 of 14
Start Up Procedure
When receiving a unit, an assiduous visual inspection must be performed. Do not connect the unit without analysing the symptoms reported by the customer and the results of the inspection.
Using the troubleshooting guide, find the problem and proceed to the repair. Once this step is done, follow these steps, known as the start-up procedure, to ensure that everything in the unit is in working condition.
1. Proceed with a post repair visual inspection. Take the time to check if every wire is reconnected
properly, every screw is bolted on, no soldering and/or metal residues lying in the unit, every fuse has been replaced, etc.
2. Turn the bias trimpots, counter clockwise until a click is heard.
3. Since there is no soft-start sequence of the CAP-151, it is impossible to use a bypass to perform a slow
start up.
4. Connect Main supply, and turn on the unit.
5. If one or more supply are not within specifications, return to the troubleshooting guide.
6. If every supply is within specifications, report to calibration and adjusments to adjust bias and DC
offset. Note that bias can be adjusted to 20mV, and the following tests can be performed before the unit is send to the burn-in bench for a 24 hours warm-up.
7. Connect the unit to a load, and to a source using single ended inputs.
8. Perform a test with a 200Hz, a 2kHz and a 20kHz tone, both sinus wave and square wave. Check the
output with a oscilloscope, on 4 ohms and 8 ohms loads. Take special cares about oscillation and phase correlation between channels.
9. Connect the unit to a small speaker, and short the input. Check for any noise.
10. Put the unit on a burn-in bench, and let it sit for 24 hours, then readjust bias. Let the unit on the burn-
in bench for another 72 hours.
11. Redo steps 7 to 11 before shipping to the customer.
PRO-SVR_LEGACY Page 5 of 14
Protection Modes and Indicators
The front LED display shows the status of the amplifier. When starting up normally, the CAP-151 will show a countdown from 20 to 0. However, there is no protection on the CAP-151. The CAP-151 is equipped with four rail protection fuses. In the event that one or more of these fuses would blow, the technician will first need to identify and cure the cause of failure (please report to troubleshooting guide). When the cause has been identified, disconnect the unit from the system including the AC power. Remove the top cover and look for damaged or burned components. If no other components than the fuses appear to be damaged, the technician can then replace the broken fuses with the same value and rating (please report to fuses section). The rail fuses are located on the main board. When replacing fuses, please make sure that the fuse holder are holding the fuses very tightly. A loose fuse holder can translate into distortion on top of the signal.
PRO-SVR_LEGACY Page 6 of 14
Troubleshooting Guide
Symptom Possible cause
Unit won’t turn on Check connections;
Smoked and/or burned components
Blown fuses Check for short between fuse and ground;
No output Check connexions;
Unit turn into protection Check for smoked and/or burned components;
Excessive buzz and/or hum Check electrical lines;
Oscillation Check source;
Intermittent signal Check connections;
Check fuses; Check soft-start circuit; Check relays; Check power supply circuits (positive rail, negative rail, Mosfet supply). Check for short between components and ground; Check output transistors; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply).
Check power supply circuits (positive rail, negative rail, Mosfet supply).
Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply); Check output transistors.
Check power supply circuits (positive rail, negative rail, Mosfet supply); Check source and load; Check protection circuit; Check sensor wires between sensor PCB and control PCB; Check outputs transistors and Mosfet drivers.
Check for a ground loop in the system.
Check capacitors on main board; Check 4.7 resistor.
Replace shield wires.
PRO-SVR_LEGACY Page 7 of 14
Output Transistors Testing and Replacement
PLEASE NOTE THAT THESE TESTS ARE ONLY EFFECTIVE ON BIPOLAR TRANSISTORS. DO NOT PERFORM THESE TESTS ON MOSFET DEVICES, AS THEY ARE LIKELY TO BECOME SHORT DURING THE TEST.
You should check all pin combinaisons, as there is a chance that only one side of the transistor is short. When replacing outputs transistors, the technician should first disconnect both outputs and main board to check if the blown outputs were caused by a faulty component on the amplifier’s base. Blown output transistors should be replaced by kits, not individually. These kits contains matched transistors for both rails of one channel. When replacing blown output transistors, you must also replace positive and negative Mosfet drivers and bias transistor. Carefully inspect 4.7 resistor and 10 soft start resistor, and replace if necessary. Replace any burnt component or board.
Pins : 1 Base 2 Collector 3 Emitter
You should have these results, if the transistor is good.
2SC3264 (NPN)
Positive lead Negative lead Result
B C Conductive B E Conductive C B Infinite C E Infinite E B Infinite E C Infinite
2SA1295 (PNP)
Positive lead Negative lead Result
B C Infinite B E Infinite C B Conductive C E Infinite E B Conductive E C Infinite
PRO-SVR_LEGACY Page 8 of 14