Cisco PVDM2-12DM, PVDM2-24DM, and
PVDM2-36DM Digital Modem Packet Voice Data
Modules
First Published: June 19, 2006
Last Updated: July 11, 2008
The Cisco digital modem packet voice data modules (Cisco PVDMs), type 2 (Cisco PVDM2s), are
high-density PVDMs containing 12, 24, or 36 digital modems. These modems provide direct digital
connection to Integrated Services Digital Network (ISDN) Primary Rate Interface (PRI) channels, to
Basic Rate Interface (BRI) channels, and to channel associated signaling (CAS) digital trunk lines. The
PVDM2s are installed in Cisco 2800 series and Cisco 3800 series integrated services routers.
Contents
Finding Feature Information in This Module
Your Cisco IOS software release may not support all of the features documented in this module. To reach
links to specific feature documentation in this module and to see a list of the releases in which each feature is
supported, use the “Feature Information for Digital Modem PVDM2s” section on page 47.
Finding Support Information for Platforms and Cisco IOS Software Images
Use Cisco Feature Navigator to find information about platform support and Cisco IOS and software image
support. To access Cisco Feature Navigator, go to <http://www.cisco.com/go/cfn>
is not required.
• Prerequisites for Cisco Digital Modem PVDM2s, page 2
• Restrictions for Cisco Digital Modem PVDM2s, page 3
• Information About Cisco Digital Modem PVDM2s, page 4
• How to Configure Digital Modem PVDM2s, page 4
• Configuration Examples for Digital Modem PVDM2s, page 22
• Additional References, page 25
. An account on Cisco.com
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Prerequisites for Cisco Digital Modem PVDM2s
• Command Reference, page 26
• Feature Information for Digital Modem PVDM2s, page 47
Prerequisites for Cisco Digital Modem PVDM2s
Supported Platforms
The following Cisco integrated services routers are supported for the digital modem PVDM2s:
• Cisco 2811
• Cisco 2821
• Cisco 2851
• Cisco 3825
• Cisco 3845
Network Interfaces
LAN connections are provided through your router’s Fast Ethernet or Gigabit Ethernet ports.
For information on how to configure the LAN interfaces on your router, see the Configuring Fast
Ethernet and Gigabit Ethernet Interfaces section of Basic Software Configuration Using the Cisco IOS
Command-Line Interface.
WAN connections are provided through Cisco network modules and interface cards. The digital modem
PVDM2s are supported with the following:
• Network modules (supported in Cisco IOS Releases 12.4(9)T and later):
–
–
• Interface cards (supported in Cisco IOS Releases 12.4(11)XW and later):
–
–
–
For information on how to install Cisco network modules, see theCisco Network Module Hardware
Installation Guide.
For information on how to install Cisco interface cards, see the Cisco Interface Card Hardware
Installation Guide.
NM-1CE1T1-PRI
NM-2CE1T1-PRI
HWIC-1CE1T1-PRI
HWIC-2CE1T1-PRI
VIC2-2BRI-NT/TE
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
2
Page 3
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
PVDM2 Installation
Install the digital modem PVDM2s in the PVDM chassis slots on your router’s motherboard.
• To install PVDM2s in Cisco 2800 series routers, see Installing and Upgrading Internal Modules in
Cisco 2800 Series Routers.
• To install PVDM2s in Cisco 3800 series routers, see Installing and Upgrading Internal Modules in
Cisco 3800 Series Routers.
Basic Information for Configurations
Make sure that you have the following information:
• Channel-group information and time-slot mapping
• ISDN PRI/BRI configuration parameters
• T1 or E1 information, such as line code and framing type
Restrictions for Cisco Digital Modem PVDM2s
Restrictions for Cisco Digital Modem PVDM2s
The following restrictions apply to the Cisco digital modem PVDM2s:
• Digital modem PVDM2s can be inserted only into PVDM2 slots on the motherboards of Cisco
routers. Initially, these routers are the Cisco 2800 series and Cisco 3800 series integrated services
routers named in the “Supported Platforms” section on page 2.
• Initial bootup time to download CSM V12 firmware to the digital modem PVDM2s may be two to
four minutes due to architectural limitations.
• Digital modem PVDM2s are supported over ISDN BRI in Cisco IOS Releases 12.4(11)XW and later.
• There is no voice support.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
3
Page 4
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Information About Cisco Digital Modem PVDM2s
Information About Cisco Digital Modem PVDM2s
This section provides information about digital modem PVDM2s.
• PVDM Line Numbering on Cisco Integrated Services Routers, page 4
• Mixing Digital Modem PVDM2s with Voice PVDMs, page 4
PVDM Line Numbering on Cisco Integrated Services Routers
This section describes the PVDM line numbering scheme for Cisco integrated services routers. Table 1
shows the line numbering scheme for digital modem PVDM2s installed in Cisco 2800 series and
3800 series routers.
Table 1PVDM Line Numbering on Cisco Integrated Services Routers
PlatformPVDM 0PVDM 1PVDM 2PVDM 3
Cisco 2811322386N/AN/A
Cisco 2821,
Cisco 2851
Cisco 3825322386450514
Cisco 3845450514578642
322386450N/A
Table 1 gives the line number assigned to the first modem in the PVDM. The remaining modems are
assigned successively increasing line numbers. Some examples are:
• A PVDM2-12DM module is installed in the PVDM 0 slot of a Cisco 2811 router. The 12 modems
on the module are assigned line numbers 322 to 333.
• A PVDM2-24DM module is installed in the PVDM 1 slot of a Cisco 3825 router. The 24 modems
on the module are assigned line numbers 386 to 409.
• A PVDM2-36DM module is installed in the PVDM3 slot of a Cisco 3845 router. The 36 modems
on the module are assigned line numbers 642 to 677.
Mixing Digital Modem PVDM2s with Voice PVDMs
There are no restrictions on the mixing of digital modem PVDM2s with Cisco voice PVDMs within the
supported platforms.
How to Configure Digital Modem PVDM2s
Complete the following tasks to configure the digital modem PVDM2s.
• Tasks Common to All Configurations, page 5
• Configuration Using NM-xCE1T1-PRI Network Modules, page 15
• Configuration Using HWIC-xCE1T1-PRI, page 19
• Configuration Using VIC2-2BRI-NT/TE, page 20
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
4
Page 5
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Tasks Common to All Configurations
Complete the following tasks for all configurations of digital modem PVDM2s.
• Configuring the Loopback Interface, page 5 (required)
• Configuring the Modem Country Code, page 6 (required)
• Configuring Modem Lines for Dial-In and Dial-Out, page 6 (required)
• Configuring the Default IP Pool Information, page 8 (required)
• Creating Group Asynchronous Interfaces, page 8 (required)
• Configuring the Dialer Interface, page 10 (required)
• Configuring Modem Pooling, page 11 (optional)
• Configuring Modem Recovery, page 12 (optional)
• Loading Modem Firmware, page 13 (optional)
Configuring the Loopback Interface
How to Configure Digital Modem PVDM2s
SUMMARY STEPS
DETAILED STEPS
Command or ActionPurpose
Step 1
interface Loopback number
Example:
Router(config)# loopback 0
Step 2
ip address ip-address ip-address mask
Example:
Router(config-if)# ip address 127.0.0.1
255.255.0.0
The loopback 0 interface is the interface that dial-in users access when dialing in to the network. Usually,
all dial-in users are assigned to a single IP subnet. This subnet can be identified with the loopback 0
interface, a logical interface whose network number can be borrowed by each asynchronous dial-in
interface.
To configure the loopback 0 interface, perform the following tasks, beginning in global configuration mode:
1. interface Loopback number
2. ip address ip-address ip-address mask
Selects the loopback 0 interface.
Assigns an IP address and subnet mask to the loopback 0
interface.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
5
Page 6
How to Configure Digital Modem PVDM2s
Configuring the Modem Country Code
To configure the modem country code for a bank of V12 modems, use the modem country v12
command in global configuration mode.
SUMMARY STEPS
1. modem country v12 country
DETAILED STEPS
Command or ActionPurpose
Step 1
modem country v12 country
Example:
Router(config)# modem country v12 t1-default
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Configures the modem country code for the bank of V12
modems in your digital modem PVDM2s.
Default for T1 connections is t1-default.
Default for E1 connections is e1-default.
Configuring Modem Lines for Dial-In and Dial-Out
The following tasks configure modem lines for dial-in and dial-out.
• Configuring Modems for Dial-In, page 6 (required)
• Configuring Modems for Dial-Out, page 7 (required)
Configuring Modems for Dial-In
Beginning in global configuration mode, follow these steps to configure modem lines for dial-in.
SUMMARY STEPS
1. line start-range end-range
2. modem inout
3. transport input all
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
6
Page 7
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
DETAILED STEPS
Command or ActionPurpose
Step 1
line start-range end-range
Selects the modem lines for dial-in and switch to the line
configuration mode.
Example:
Router(config)# line 334 345
Step 2
modem inout
Configures the line for both incoming and outgoing calls.
Example:
Router(config-line)# modem inout
Step 3
transport input all
Selects the protocol used to connect to the router. all selects
all protocols.
Example:
Router(config-line)# transport input all
How to Configure Digital Modem PVDM2s
Configuring Modems for Dial-Out
To configure the modem lines for dial-out, perform the following tasks, beginning in global configuration
mode:
SUMMARY STEPS
1. line start-range end-range
2. rotary number
3. transport input telnet
4. modem inout
DETAILED STEPS
Command or ActionPurpose
Step 1
line start-range end-range
Example:
Router(config)# line 322 333
Step 2
rotary number
Selects the modem lines for dial-out and switch to the line
configuration mode.
Sets the router to use previously-defined rotary group.
Example:
Router(config-line)# rotary 1
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
7
Page 8
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
How to Configure Digital Modem PVDM2s
Command or ActionPurpose
Step 3
transport input telnet
Example:
Router(config-line)# transport input telnet
Step 4
modem inout
Example:
Router(config-line)# modem inout
Configuring the Default IP Pool Information
You need to set a range of IP addresses in the default IP pool. These IP addresses are used for dial-in users.
To set the range of addresses, perform the following task in global configuration mode:
SUMMARY STEPS
1. ip pool local default low-ip-address [high-ip-address]
2. ip default gateway number
3. ip classless
Configures the router to accept inbound Telnet connections.
Configures the line for both incoming and outgoing calls.
DETAILED STEPS
Command or ActionPurpose
Step 1
ip pool local default low-ip-address
[high-ip-address]
Example:
Router(config)# ip pool local default
172.16.0.1 172.16.0.36
Step 2
ip default gateway number
Example:
Router(config)# ip default gateway 101
Step 3
ip classless
Example:
Router(config)# ip classless
Creating Group Asynchronous Interfaces
A group asynchronous interface is a parent interface that applies protocol characteristics to specified,
associated asynchronous interfaces. After you create a group asynchronous interface, all associated
asynchronous interfaces (called members) can be configured through it. Group asynchronous interfaces
can speed configuration time and help you maintain interface configuration consistency.
Beginning in global configuration mode, follow these steps to configure a group asynchronous interface.
Sets the range of addresses in the default IP pool to be
assigned to inbound callers.
Defines a default gateway (router) when IP routing is
disabled.
Forwards packets destined for a subnet of a network that has
no network default route.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
8
Page 9
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
SUMMARY STEPS
1. interface group-async number
2. ip unnumbered Loopback number
3. encapsulation ppp
4. dialer in-band
5. async mode interactive | dedicated
6. peer default ip address pool name
7. no cdp enable
8. group-range start-range end-range
DETAILED STEPS
Command or ActionPurpose
Step 1
interface group-async number
Creates a group asynchronous interface.
How to Configure Digital Modem PVDM2s
Step 2
Step 3
Step 4
Step 5
Step 6
Example:
Router(config)#interface group-async 1
ip unnumbered Loopback number
Example:
Router(config-if)#ip unnumbered Loopback 0
encapsulation ppp
Example:
Router(config-if)#encapsulation ppp
dialer in-band
Example:
Router(config-if)# dialer in-band
async mode interactive | dedicated
Example:
Router(config-if)#async mode interactive
peer default ip address pool name
Example:
Router(config-if)#peer default ip address pool
name
Enables IP processing on the loopback interface without
assigning an explicit IP address to the interface.
Sets the Point-to-Point Protocol (PPP) as the encapsulation
method used by this interface.
Specifies that dial-on-demand routing (DDR) be supported.
interactive enables SLIP and PPP EXEC commands on this
interface. dedicated disables SLIP and PPP EXEC
commands, and sets the encapsulation to what is configured
for the interface.
Specifies an IP address from the defined IP address pool to
be returned to a remote peer connecting to this interface.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
9
Page 10
How to Configure Digital Modem PVDM2s
Command or ActionPurpose
Step 7
no cdp enable
Example:
Router(config-if)#no cdp enable
Step 8
group-range start-range end-range
Example:
Router(config-if)#group-range 0/322 0/345
Configuring the Dialer Interface
The dialer interface is the parent interface that holds the central protocol characteristics for the dialer-rotary
group. To configure the dialer interface, perform the following tasks, beginning in global configuration mode:
SUMMARY STEPS
1. interface Dialer number
2. ip unnumbered Loopback number
3. no ip mroute-cache
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Disables Cisco Discovery Protocol on this interface.
Associates one or more interfaces to the group interface so
that all associated interfaces can be configured through the
group interface.
DETAILED STEPS
Command or ActionPurpose
Step 1
interface Dialer number
Example:
Router(config)# interface dialer 101
Step 2
ip unnumbered Loopback number
Example:
Router(config-if)# ip unnumbered loopback 0
Step 3
no ip mroute-cache
4. encapsulation ppp
5. peer default ip address pool name
6. dialer in-band
7. dialer-group number
8. no fair-queue
9. no cdp enable
Defines a dialer rotary group leader.
Enables IP processing on the loopback interface without
assigning an explicit IP address to the interface.
Disables IP multicast fast switching.
Example:
Router(config-if)# no ip mroute cache
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
10
Page 11
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Command or ActionPurpose
Step 4
encapsulation ppp
Sets the PPP as the encapsulation method used by this
interface.
Example:
Router(config-if)# encapsulation ppp
Step 5
peer default ip address pool name
Specifies an IP address from the defined IP address pool to
be returned to a remote peer connecting to this interface.
Example:
Router(config-if)#
Step 6
dialer in-band
Specifies that dial-on-demand routing (DDR) be supported.
Example:
Router(config-if)# dialer in-band
Step 7
dialer-group number
Assigns this interface to the rotary dialer group.
Example:
Router(config-if)# dialer-group 1
Step 8
no fair-queue
Disables fair weighted queuing for this interface.
How to Configure Digital Modem PVDM2s
Example:
Router(config-if)# no fair-queue
Step 9
no cdp enable
Example:
Router(config-if)# no cdp enable
Configuring Modem Pooling
Modems may be pooled so that specific ranges of the available modems are assigned to the various called
numbers handled by your system.
NoteAny modem not assigned to a defined modem pool is assigned to the default modem pool.
Restrictions
If you are using modem pooling in a CAS configuration, the following restrictions apply:
• There must be at least one modem in the default modem pool for the modem pooling feature to work
for CAS calls. This is because every time a CAS call is made, a modem in the default pool is used
to collect the digits of the called number. Once the digits are collected, the call is forwarded to the
appropriate modem pool. One of the modems in that pool will be allocated for the call, and the
modem in the default pool will then be released. If there are no available modems in the default pool,
the call will not go through.
• Whenever signaling type e&m-fgb is specified in the ds0-group command, it is necessary to
configure dtmf dnis as part of the signaling type.
Router(config)# ds0-group 1 timeslots 1-24 type e&m-fgb dtmf dnis
Disables Cisco Discovery Protocol on this interface.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
11
Page 12
How to Configure Digital Modem PVDM2s
When dtmf dnis is part of the ds0-group command, functions in CSM V12 firmware collect the
digits of the called number and match them to the called number in the appropriate modem pool,
putting the call through. If dtmf dnis is not part of the ds0-group command, these functions are
never activated and no called number match is made, resulting in a default pool modem being used
instead of a modem from the correct pool. The call will not go through in such a case.
SUMMARY STEPS
1. modem-pool name
2. pool-range modem1-modemN
3. called-number number max-conn number
DETAILED STEPS
Command or ActionPurpose
Step 1
modem-pool name
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Assigns a name to the modem pool.
Example:
Router(config)# modem-pool tito
Step 2
Step 3
pool-range modem1-modemN
Example:
Router(config)# pool-range 386-388
called-numbernumber max-connnumber
Example:
Router(config)# called-number 5557528 max-conn 3
Configuring Modem Recovery
The modem recovery feature is present to detect bad modems and mark them, saving the user from the
task of doing this manually. If there are spare modems in the platform, this process could prevent callers
from getting dead air or busy signals.
The modem recovery feature uses two CLI commands. The modem recovery threshold command sets
the number of consecutive failures that a modem must experience before the recovery process is
performed. The modem recovery action command defines the action taken on the failed modem. The
recovery action will either be “disable”, where the IOS will mark the modem bad, or will be “none”,
where nothing will happen to the modem and the threshold counter will be reset.
A modem failure is defined as any time that the CSM assigns a call to a modem, but that modem does
not reach steady state. The call would be classed as a “no answer” or as a trainup failure.
Specifies the range of modem numbers assigned to
the modem pool.
If the modem pool consists of a single modem, the
modem number of that modem is entered by itself, as
in pool-range 386, for example.
Specifies a called number assigned to the modem
pool. The variable max-conn specifies the
maximum number of simultaneous calls that may be
connected to the called number.
To configure modem recovery, enter the following commands in global configuration mode.
SUMMARY STEPS
1. modem recovery threshold failed-calls
2. modem recovery action {disable | none}
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
12
Page 13
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
DETAILED STEPS
Command or ActionPurpose
Step 1
modem recovery threshold failed-calls
Specifies the number of consecutive failure that
must occur on a modem before modem recovery
action takes place.
The range is 0 to 1000. The default value is 30.
Specifies the action to be taken on a modem when its
Step 2
Example:
Router(config)# modem recovery threshold 10
modem recovery action {disable | none}
modem recovery threshold is reached. disable will
cause the IOS to mark the modem as bad and remove
it from service. none will reset the threshold counter
Example:
Router(config)# modem action recovery disable
for the modem, but will do nothing else. The modem
stays in service.
Example
The following configuration will result in a modem being marked bad by the IOS after 8 consecutive
failures.
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Enters router configuration mode.
Loads a different version of CSM V12 firmware into the
digital modem PVDM2s.
• slot-number specifies the chassis slot that contains the
PVDM modules with CSM V12 digital modems. In ISR
routers, slot 0, the router’s motherboard, is the chassis
slot for all digital modem PVDM2s.
• ifsfilename specifies the Cisco IOS file system (IFS)
filename of the CSM V12 firmware to be loaded into
the modem.
Exits global configuration mode.
Example:
Router(config)# exit
Verification of Firmware Loading
Use the show modem version command to verify that the new firmware version has been downloaded
to the modems. In the example shown here, the router has a PVDM2-24DM module with 24 digital
modems (channel numbers 386 to 409). Version 3.07 of the firmware is replaced with version 3.08.
Version 3.08 is stored in the file flash:V3_08.axf in the router’s flash memory.
Before the download takes place, the show modem version command shows the following:
Router>configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#modem firmware slot 0 location flash:V3_08.axf
This command will disconnect any active calls.
Proceed with firmware upgrade? [confirm]
Modem Slot 0: Started firmware download.
Modem 0/386 - 0/409 ...
Modem Slot 0: Completed firmware download
Router(config)#exit
Router#
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
14
Page 15
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
After the download takes place, the show modem version command shows the following:
To configure NM-CE1T1 network modules for PRI operation or CAS operation, perform the following
procedures.
• Configuring the T1/E1 Network Module, page 15 (required)
• Configuring ISDN Digital Modem Calls (PRI), page 16 (optional)
• Configuring Digital Trunk Calls (CAS), page 18 (optional)
How to Configure Digital Modem PVDM2s
Configuring the T1/E1 Network Module
The first step in configuring a digital modem interface is to configure the channelized T1 or E1 network
module. The Cisco NM-1CE1T1-PRI network module has one port; The Cisco NM-2CE1T1-PRI network
module has two ports. If the network module installed in your router has two ports, you need to do the
following procedure on both ports.
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Specifies the network module type in the named slot.
Allows the ports on a specified network module to use the
network clock for timing.
Specifies the clocking configuration for the selected port.
Allows configuration of the selected T1 or E1 controller.
Example:
Router(config-if)# controller t1 1/0
Step 5
framing {sf | esf | crc4 | no crc4}
Example:
Router(config-if)# framing esf
Step 6
linecode {ami | b8zs | hdb3}
Example:
Router(config-if)# linecode b8zs
Configuring ISDN Digital Modem Calls (PRI)
Perform the following procedures to complete the configuration of digital modem PVDM2s for ISDN
digital data calls.
• Configuring the ISDN Switch Type and PRI Group, page 17 (required)
• Configuring the ISDN D-Channel Serial Interface, page 17 (required)
Specifies frame type for a T1 or E1 connection.
• sf selects super frame type for T1.
• esf selects extended super frame type for T1.
• crc4 selects crc4 frame type for E1.
• no crc4 selects no crc4 frame type for E1.
Selects the linecode type for a T1 or E1 connection.
• ami specifies ami linecode type. Valid for T1 and E1.
Default value for T1.
• b8zs specifies b8zs linecode type. Valid for T1 only.
• hdb3 specifies linecode type hdb3. Default value for
E1.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
16
Page 17
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Configuring the ISDN Switch Type and PRI Group
Perform the following steps to properly connect with the ISDN central office and to define the group of
timeslots used.
SUMMARY STEPS
1. isdn switch-type switch-type
2. pri-group timeslots timeslot-range
DETAILED STEPS
Command or ActionPurpose
Step 1
isdn switch-type switch-type
Specifies the central office switch type on the ISDN
interface.
See the Cisco IOS Release 12.4 Master Commands List for
a complete listing of supported signaling methods.
Specifies an ISDN PRI group on a channelized T1 or E1
Step 2
Example:
Router(config)# isdn switch-type primary-qsig
pri-group timeslotstimeslot-range
controller.
timeslot-range specifies the time slots that are included in
Example:
Router(config)# pri-group timeslots 1-24
the PRI group. For T1 ports, time slots range from 1 to 24.
For E1 ports, time slots range from 1 to 31.
How to Configure Digital Modem PVDM2s
Configuring the ISDN D-Channel Serial Interface
When you configure ISDN PRI on a channelized E1 or channelized T1 controller, you create a
corresponding D-channel serial interface used to carry signaling messages for that PRI group. For E1
modules, channel 15 is the D-channel. For T1 modules, channel 23 is the D-channel. You must configure
this signaling interface in order to receive incoming and modem calls.
The PRI network modules and interface cards for your router can have either one or two ports; therefore
you might have multiple D-channels to configure.
To configure the ISDN D-channel serial interface for E1 or T1 controllers, perform the following tasks,
beginning in global configuration mode:
SUMMARY STEPS
1. interface Serial slot/port:channel
2. no ip address
3. encapsulation ppp
4. isdn incoming-voice modem
5. no fair-queue
6. no cdp enable
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
17
Page 18
How to Configure Digital Modem PVDM2s
DETAILED STEPS
Command or ActionPurpose
Step 1
interface Serial slot/port:channel
Example:
Router(config)# interface Serial 1/0:23
Step 2
no ip address
Example:
Router(config-if)# no ip address
Step 3
encapsulation ppp
Example:
Router(config-if)# encapsulation ppp
Step 4
isdn incoming-voice modem
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Specifies the D-channel of the first PRI line and switch to
the interface configuration mode.
• For E1 controllers, channel = 15
• For T1 controllers, channel = 23
Disables IP processing on this interface.
Sets the Point-to-Point Protocol (PPP) as the encapsulation
method used by this interface.
Configures all incoming voice calls to go to the modems.
Example:
Router(config-if)# isdn incoming-voice modem
Step 5
no fair-queue
Example:
Router(config-if)# no fair-queue
Step 6
no cdp enable
Example:
Router(config-if)# no cdp enable
Configuring Digital Trunk Calls (CAS)
Perform the following step to complete the configuration of digital modem PVDM2s for CAS digital
trunk calls.
SUMMARY STEPS
1. ds0-group group-number timeslots list type type
Disables fair weighted queuing for this interface.
Disables Cisco Discovery Protocol on this interface.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
18
Page 19
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
DETAILED STEPS
Command or ActionPurpose
Step 1
ds0-group group-number timeslots list type type
Specifies the DS0 time slots that make up a port.
list specifies the time slots that are included in the DS0
group. For T1 ports, time slots range from 1 to 24. For E1
ports, time slots range from 1 to 31.
Example:
Router(config)# ds0-group 1 timeslots 1-24 type
e&m-immediate-start
Refer to Cisco IOS Release 12.4 Master Commands List for
a complete listing of supported signaling methods.
Configuration Using HWIC-xCE1T1-PRI
To configure T1/E1HWICs for PRI operation, perform the following tasks:
To configure VIC2-2BRI VICs for BRI operation, perform the following steps.
SUMMARY STEPS
1. configure terminal
2. isdn switch-type {basic-net3 | basic-qsig}
3. interface bri <slot/port>
4. no ip address
5. end
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
20
Page 21
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
DETAILED STEPS
CommandPurpose
Step 1
configure terminal
Enters the global configuration mode.
Example:
router# configure terminal
Step 2
isdn switch-type {basic-net3 | basic-qsig}
Specifies the ISDN switch type.
Example:
router(config)# isdn switch-type basic-net3
Step 3
interface bri <slot/port>
Changes to interface configuration mode for a given
port in a designated slot.
Example:
router(config)# interface bri 0/0
Step 4
no ip address
Specifies that there is no IP address for this interface.
How to Configure Digital Modem PVDM2s
Step 5
Example:
router(config-if)# no ip address
end
Example:
router(config-if)# end
Exits configuration mode.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
21
Page 22
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Configuration Examples for Digital Modem PVDM2s
Configuration Examples for Digital Modem PVDM2s
This section provides the following configuration examples:
• Configuring a T1 Controller for CAS Digital Trunk Calls: Example, page 22
• Configuring a T1 Controller for ISDN Digital Modem Calls: Example, page 23
Configuring a T1 Controller for CAS Digital Trunk Calls: Example
The following example shows the T1 CAS configuration for a PVDM2-36DM module in PVDM slot 0
of a Cisco 2851 router.
version 12.4
service timestamps debug datetime msec
service timestamps log datetime msec
no service password-encryption
!
card type t1 1
!
no aaa new-model
!
resource policy
!
network-clock-participate slot 1
network-clock-select 1 T1 1/0
!
modem country v12 t1-default
!
ip cef
!
no ip domain lookup
!
controller T1 1/0
framing esf
linecode b8zs
ds0-group 1 timeslots 1-24 type e&m-immediate-start
!
controller T1 1/1
framing esf
linecode b8zs
!
interface Loopback0
ip address 10.0.0.1 255.255.255.255
!
interface GigabitEthernet0/0
no ip address
duplex auto
speed auto
!
interface GigabitEthernet0/1
no ip address
duplex auto
speed auto
!
interface Dialer101
ip address 10.101.0.1 255.255.0.0
encapsulation ppp
dialer pool 1
dialer idle-timeout 2147483
dialer string 101
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
22
Page 23
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
dialer-group 1
no cdp enable
no ppp authentication
!
interface Group-Async1
no ip address
encapsulation ppp
load-interval 30
dialer in-band
dialer pool-member 1
async mode dedicated
no peer default ip address
no ppp authentication
group-range 0/322 0/357
!
no ip http server
!
dialer-list 1 protocol ip permit
!
control-plane
!
line con 0
exec-timeout 0 0
line aux 0
exec-timeout 0 0
line 0/322 0/357
modem InOut
transport input all
line vty 0 4
password *****
login
!
scheduler allocate 20000 1000
!
end
Configuration Examples for Digital Modem PVDM2s
Configuring a T1 Controller for ISDN Digital Modem Calls: Example
The following example shows the T1 PRI (ISDN) configuration for a PVDM2-36DM module in PVDM
slot 0 of a Cisco 2851 router.
version 12.4
service timestamps debug datetime msec
service timestamps log datetime msec
no service password-encryption
card type t1 1
!
no aaa new-model
!
resource policy
!
network-clock-participate slot 1
network-clock-select 1 T1 1/0
!
modem country v12 t1-default
!
ip cef
!
no ip domain lookup
!
isdn switch-type primary-qsig
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
23
Page 24
Configuration Examples for Digital Modem PVDM2s
!
controller T1 1/0
framing esf
linecode b8zs
pri-group timeslots 1-24
!
controller T1 1/1
framing esf
linecode b8zs
!
interface Loopback0
ip address 10.0.0.1 255.255.255.255
!
interface GigabitEthernet0/0
no ip address
duplex auto
speed auto
!
interface GigabitEthernet0/1
no ip address
duplex auto
speed auto
!
interface Serial1/0:23
no ip address
encapsulation ppp
isdn switch-type primary-qsig
isdn incoming-voice modem
no cdp enable
!
interface Dialer101
ip address 10.101.0.1 255.255.0.0
encapsulation ppp
dialer pool 1
dialer idle-timeout 2147483
dialer string 101
dialer-group 1
no cdp enable
no ppp authentication
!
interface Group-Async1
no ip address
encapsulation ppp
load-interval 30
dialer in-band
dialer pool-member 1
async mode dedicated
no peer default ip address
no ppp authentication
group-range 0/322 0/357
!
no ip http server
!
dialer-list 1 protocol ip permit
!
control-plane
!
line con 0
exec-timeout 0 0
line aux 0
exec-timeout 0 0
line 0/322 0/357
modem InOut
transport input all
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
24
Page 25
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
line vty 0 4
password *****
login
!
scheduler allocate 20000 1000
!
end
Additional References
The following sections provide references related to digital modem PVDM2s.
Related Documents
Related TopicDocument Title
Installation instructions for PVDMs in Cisco 2800
series routers
Installation instructions for PVDMs in Cisco 3800
series routers
Modem Pooling - PRIDNIS and Modem Pooling with a PRI Line
Modem Pooling - CASDNIS and Modem Pooling Using a CAS T1 Line
Installing and Upgrading Internal Modules in Cisco 2800 Series
Routers
Installing and Upgrading Internal Components in Cisco 3800 Series
Routers
Additional References
Standards
StandardTitle
No new or modified standards are supported by this
feature, and support for existing standards has not been
modified by this feature.
—
MIBs
MIBMIBs Link
No new or modified MIBs are supported by this
feature, and support for existing MIBs has not been
modified by this feature.
To locate and download MIBs for selected platforms, Cisco IOS
releases, and feature sets, use Cisco MIB Locator found at the
following URL:
http://www.cisco.com/go/mibs
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
25
Page 26
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Command Reference
RFCs
RFCTitle
No new or modified RFCs are supported by this
feature, and support for existing RFCs has not been
modified by this feature.
—
Technical Assistance
DescriptionLink
The Cisco Technical Support & Documentation
website contains thousands of pages of searchable
technical content, including links to products,
technologies, solutions, technical tips, and tools.
Registered Cisco.com users can log in from this page to
access even more content.
http://www.cisco.com/techsupport
Command Reference
This section documents new commands only.
New Commands
• debug pvdm2dm
• modem country v12
• show modem configuration (pvdm2)
• show modem log (pvdm2)
• show modem operational-status (pvdm2)
• show modem version (pvdm2)
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
26
Page 27
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
debug pvdm2dm
To view contents of packets flowing through PVDMII-xxDM digital modem devices, use the debug
pvdm2dm command in privileged EXEC mode. To disable debug activity, use the no form of this
Usage GuidelinesTo debug the contents of modem packets for a specific modem, use the following command:
• debug pvdm2dm packetmodem<slot>/<port>
By removing the specific modem number at the end, one can enable packet debugging for all the modems
available on the router:
• debug pvdm2dm packetmodem
The following command enables packet debugging for all packets flowing through a particular
PVDMII-xxDM device:
• debug pvdm2dm packetpvdm<slot>/<pvdm slot>
The following command enables debugging of packets flowing through any PVDMII-xxDM device:
• debug pvdm2dm packetpvdm
The following command enables debugging of packets flowing through any PVDMII-xxDM device and
any PVDMII-xxDM-based modem channel:
• debug pvdm2dm packet
To see what debug flags are set, and to view the contents of debugged packets, use the show debugging
command.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
27
Page 28
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
debug pvdm2dm
ExamplesThe following example sets debugging for a specific modem. The following show debugging command
displays the debug flag that is set, and gives a typical printout for one debugged packet:
Router# debug pvdm2dm packet modem 0/322
Router# show debugging
PVDM2 DM:
Modem 0/322 packet debugging is on
Router#
May 24 17:35:16.318: pvdm2_dm_tx_dsp_pak_common: bay 0, dsp 0 May 24 17:35:16.318:
pvdm2_dm_dump_pak_hex: pak: 43E1F6FC size 8 May 24 17:35:16.318: 00 08 00 00 00 1C 00 00
May 24 17:35:16.322:
The following example sets debugging for all PVDMII-xxDM modems available on the router.
Router# debug pvdm2dm packet
Router# show debugging
PVDM2 DM:
Modem 0/322 packet debugging is on
Modem 0/323 packet debugging is on
Modem 0/324 packet debugging is on
.
.
.
Modem 0/355 packet debugging is on
Modem 0/356 packet debugging is on
Modem 0/357 packet debugging is on
Router#
The following example sets debugging for a particular PVDMII-xxDM device.
Router# debug pvdm2dm packet pvdm 0/0
Router# show debugging
PVDM2 DM:
PVDM2 0/0 packet debugging is on
Router#
The following example sets debugging for all PVDMII-xxDM devices in the router.
Router# debug pvdm2dm packet pvdm
Router# show debugging
PVDM2 DM:
PVDM2 0/0 packet debugging is on
PVDM2 0/1 packet debugging is on
PVDM2 0/2 packet debugging is on
Router#
In all of these examples, the output describing the debugged packets is similar to that of the first example,
except that the packet contents will vary.
Related CommandsCommandDescription
show debuggingDisplays information about the type of debugging enabled for your router.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
28
Page 29
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
modem country v12
To configure the modem country code for a bank of V12 modems, use the modem country v12
command in global configuration mode. To remove a country code from service, use the no form of this
command.
modem country v12 country
no modem country v12 country
modem country v12
Syntax Description
countryCountry name. See Usage Guidelines for a list of the supported country names.
Command DefaultCommand is disabled.
Command ModesGlobal configuration
Command History
ReleaseModification
12.4(9)TThis command was introduced.
Usage GuidelinesThe supported codes for the country argument are as follows:
• australia
• austria
• belgium
• china
• cyprus
• czech-republic (Czech/Slovak Republic)
• denmark
• e1-default (Default E1, a-law)
• finland
• france
• germany
• hong-kong
• india
• ireland
• israel
• italy
• japan
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
29
Page 30
modem country v12
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
• malaysia
• netherlands
• new-zealand
• norway
• poland
• portugal
• russia
• singapore
• south-africa
• spain
• sweden
• switzerland
• t1-default (Defaults T1, u-law)
• taiwan
• thailand
• turkey
• united-kingdom
• usa
ExamplesThe following example sets the V12 modems for operation in Sweden:
modem country v12 sweden
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
30
Page 31
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
show modem configuration (pvdm2)
To display the current modem configuration for digital modems on PVDM2-xxDM devices, use the
show modem configuration command in privileged EXEC mode.
show modem configuration [slot/modem number]
show modem configuration (pvdm2)
Syntax Description
slot/modem number(Optional) Slot and modem number. If this number is not specified, statistics
for all connected modems are displayed. You must type in the forward slash
(/).
Command ModesPrivileged EXEC
Command History
ReleaseModification
12.4(11)XWThis command was introduced.
ExamplesThe following is sample output from the show modem configuration command for a V12 modem. A
specific modem, 0/322, is designated.
Router# show modem configuration 0/322
Modem (0/322) Configuration Status:
S-Reg Value Meaning
-------|-------|-------------------------------------------- S00 = 0 Auto Answer disabled
S01 = 0 Ring Counter is 0
S02 = 43 escape character is 0x2B or '+'
S03 = 13 carriage return character is 0xD
S04 = 10 line feed character is 0xA
S05 = 8 backspace character is 0x8
S06 = 2 pause 2 seconds before blind dialing
S07 = 70 wait up to 70 seconds for carrier after dialing
S08 = 2 comma adds 2 second dial delay
S09 = 6 0.6 second Carrier detect response time
S10 = 14 1.4 second delay for hangup after carrier loss
S11 = 95 0.095 second DTMF Tone Duration
S11 = 50 Escape Prompt Delay (in .02s)
S14 = 138 Command echo enabled (E1), Send result codes (Q0),
Result codes is verbose (V1), Tone (T), Originate,
S16 = 0 Local analog loopback disabled
Local digital loopback disabled
Remote digital loopback not in progress RDL not requested
RDL with self test disabled
Local analog loopback with self test disabled
S18 = 0 Test Timer = 0x0, test will not terminate if zero
S21 = 52 Set by &J0 command but ignored otherwise,
CTS always on (&R1), DTR behavior &D2 selected,
RLSD (DCD) behavior &C1 selected,
DSR behavior &S0 selected Long space disconnect Y0,
S22 = 119 Speaker/Results 0x77 not supported
S23 = 54 RDL not allowed (&T5), DTE Rate 2400 bps,
Assumed DTE parity none, Guard tone none (&G0),
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
31
Page 32
show modem configuration (pvdm2)
S24 = 0 0 second Sleep Inactivity Timer
S25 = 5 Delay 5 (sec for async; 0.01 sec otherwise) to ignore DTR
S26 = 1 Delay 0.01 seconds RTS to CTS Delay
S27 = 73 Sync./Async. selection &Q5 Dial up line (&L0),
Internal clock (&X0), Bell mode (B1),
S28 = 0 39%-61% make/break ratio at 10 pulses per second (&P0)
S29 = 70 Flash Dial Modifier Time is 700 ms
S30 = 0 No Disconnect Inactivity Timer
S31 = 6 Single line connect message controlled by S95, Wn and Vn
Auto line speed detection enabled(N1)
Error correction progress messages full reporting (W1)
S32 = 17 XON character is 0x11
S33 = 19 XOFF character is 0x13
S36 = 7 Attempt MNP connection, if fails, Normal mode
S37 = 0 Attempt automode connection
S38 = 20 20 seconds Delay Before Forced Hang Up
S39 = 3 RTS/CTS (&K3)
S40 = 88 Disable extended services(-K0)
Break Handling (\Kn) not supported
NMP block size 128 chars (\A1)
S41 = 139 Compression selection is MNP 5 and V.42 bis
Retrain and fallback/fall forward disabled
S46 = 138 Execute error correction protocol with compression
S48 = 7 V.42 negotiation enabled
S82 = 128 Break Handling Options/LAPM Break Control = 0x80
S82 = 21
S91 = 13 -13 dBm Transmit Level in analog modulations
S92 = 13 -13 dBm Transmit Level for the fax mode
S95 = 0 CONNECT result code indicates DTE speed
Not append/ARQ to CONNECT 'rate' in error-correction
Disable CARRIER 'rate' result code
Disable PROTOCOL 'identifier' result code
Disable COMPRESSION 'type' result code
S200 = 223 Enable K56Plus
S202 = 2 K56Plus protocol follows the setting of ATNn
Enables V.90 digital pad compensation
Disable Display Tx and Rx HNDSHK states
No automatic CX802xx/CX803xx status response
K56flex Tx level is -12 dBm V90 Tx level is -12 dBm
Disable V.42 selective reject
S210 = 13 2400,2800,3000,3200,3429 V.34 asymmetric rates enabled
S220 = 11 Duration of Answer Tone is 0xB (in units of 450ms)
S221 = 50 500 ms Duration of Billing Delay
S222 = 0
S223 = 23 -12 dBm V.90 PCM Transmit Level
S224 = 0 Digital detect timer (100ms per unit)
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Table 2 describes the S register fields shown in the display.
Table 2show modem configuration Field Descriptions for V12 Modems
S RegisterFieldDescription
S00Rings to Auto-Answer0 to 255. Default is 0.
S01Ring Counter0 to 255. Default is 0.
S02Escape CharacterDefault is 43.
S03Carriage Return CharacterDefault is 13.
S04Line Feed CharacterDefault is 10.
S05Backspace CharacterDefault is 8.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
32
Page 33
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Table 2show modem configuration Field Descriptions for V12 Modems (continued)
S RegisterFieldDescription
S06Wait Time Before Blind Dialing 2 to 255 seconds. Default/minimum is 2.
S07Wait Time for Carrier, Silence,
1 to 255 seconds. Default is 50.
or Dial Tone
S08Pause Time for Dial Delay0 to 255 seconds. Default is 2.
S09Carrier Detect Response Time1to 255 in 100 ms increments. Default is 6
(0.6 seconds).
S10Lost Carrier to Hangup Delay1 to 255 in 100 ms increments. Default is 14
(1.4 seconds).
S11DTMF Tone DurationReturns OK. Default is 95 (0.095 seconds).
S12Escape Prompt Delay (EPD)Returns OK. Default is 50 (1.00 seconds).
S14General Bit Mapped Options
Status
S16General Bit Mapped Test
Sets/resets command echo, quiet mode, result codes,
tone/pulse, originate/answer.
Status of analog and digital loopback tests.
Options Status
S18Test TimerLength of test before returning to command mode.
0 to 255 seconds. Default is 0.
S21V24/General Bit Mapped
Status of behavior of CTS, DTR, DCD, and DSR.
Options Status
S22Speaker/Results Options StatusNot supported.
S23General Bit Mapped Options
Status of RDL, DTE rate, DTE parity, and guard tone.
Status
S24Sleep Inactivity Timer0 to 255 seconds. Default is 0 (no sleep).
S25Delay to DTR0 to 255 in 10 ms increments (or full seconds for
synchronous modes). Default is 5.
S26RTS to CTS Delay0 to 255 in 10 ms increments. Default is 1.
S27Bit Mapped Options StatusSync/async selection, leased line control, clock select,
CCITT/Bell mode select.
S28Bit Mapped Options StatusPulse dialing make/break ratio. Default is 39 - 61% at
10 pulses/second.
S29Flash Dial Modifier Time0 to 255 in 10 ms increments. Default is 70
(0.7 seconds).
S30Disconnect Inactivity Timer0 to 255 in 10 second increments (0 to 2550 seconds).
Default is 0 (disabled).
S31Bit Mapped Options StatusSingle line connect message, auto line speed detect,
error correction progress message.
S32XON CharacterDefault is 0x11.
S33XOFF CharacterDefault is 0x17.
S36LAPM Failure ControlIndicates activity on a LAPM failure.
S37Desired Line Connection SpeedDefault is 0 (automode connection).
S38Delay Brfore Forced Hangup0 to 255 seconds. Default is 20.
show modem configuration (pvdm2)
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
33
Page 34
show modem configuration (pvdm2)
Table 2show modem configuration Field Descriptions for V12 Modems (continued)
S RegisterFieldDescription
S39Flow Control Bit Mapped
S40General Bit Mapped Options
S41General Bit Mapped Options
S46Error Correction ProtocolDefault is 138 (execute protocol with compression).
S48V42 NegotiationDefault is 7 (negotiate).
S82Break Handling OptionsLAPM Break Control.
S86Call Failure Reason CodeDefault is 21 (clear previous reason value).
S91PSTN Transmit Attenuation
S92Fax Transmit Attenuation Level 10 to 15 (-10 to -15 dBm transmit level). Default is 10
S95Extended Result CodesIndicates overriding of Wn command options.
S200Disable K56Plus ProtocolDefault is 223 (enables).
S202CSM Bit Mapped Control
S210Symbol Rate LimitV34 symbol rate limit, symmetric or asymmetric.
S220Duration of Answer ToneCommand is in units of 450 ms. Default is 11
S221Duration of Billing Delay0 to 255 in 10 ms increments. Default is 50 (500 ms).
S222General Purpose RegisterStatus of Lucent negotiation with V.8bis.
S223V.90 PCM Transmit Level
S224Digital Detect TimerAutodetects incoming call from ISDN V110/V120 or
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Options Sta’tus
Status
Status
Level in Analog Modulations
Register
Adjust
Status of flow control.
MNP extended services, block size, and break
handling.
Compression selection, auto retrain, fallback/fall
forward.
0 to 20 (0 to -20 dBm transmit level). Default is 10
(-10 dBm).
(-10 dBm).
Controls K56flex/V90 Tx level and automatic
CX802xx/CX803xx status response.
(4950 ms).
0 to -16 dBm. Default is 23 (-12 dBm).
analog modem. 0 to 100 in 100 ms increments. Default
is 0.
Related Commands
CommandDescription
show modem log (pvdm2)Displays the modem history event status performed on a
show modem operational-status
(pvdm2)
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
34
manageable modem or group of modems.
Displays the current modem operational status for V12 digital
modems on PVDM2-xxDM devices.
Page 35
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
show modem log (pvdm2)
To display the modem history event status performed on a manageable modem on a PVDM2-xxDM
device, use the show modem log command in privileged EXEC mode.
show modem log slot/modem number
show modem log (pvdm2)
Syntax Description
slot/modem number(Optional) Slot and modem number. If this number is not specified, statistics
for all connected modems are displayed. (Include the forward slash (/) when
entering this variable.)
Command ModesPrivileged EXEC
Command History
ReleaseModification
12.4(11)XWThis command was introduced.
ExamplesThe following is sample output from the show modem log command issued on a Cisco PVDMII-xxDM
device with V12 digital modems. A specific modem, 0/323, is designated.
Router# show modem log 0/323
Modem 0/322 V12: Event Log contains 72 Events:
00:15:31.116 CSM: Incoming call from Unknown to 223
00:15:31.116 CSM: event-ISDN_CALL New State-IC_MODEM_RESERVED
CSM: status-1 dchan-0/3 bchan-0
00:15:31.068 Cmd: PCMENCODE
00:15:31.068 Cmd: CMDDAT Config Change ATS
5B 0D DF 17
00:15:31.068 CSM: event-ISDN_CONNECTED New State-WAIT_FOR_CARRIER
00:15:31.036 CSM: event-CSM_EVENT_MODEM_SETUP New State-WAIT_FOR_CARRIER
00:15:31.036 Ntf: PCMENCODE
00:15:31.032 Ntf: CMDDAT Config Acknowledge ATS
Pass Pass
00:15:31.032 Ntf: CMDREQ
00:15:31.012 Cmd: LINECON
00:15:31.012 Ntf: ANSDET
00:15:14.092 Cmd: CMDDAT Statistic--Data Transfer Information
00:15:14.092 CSM: event-MODEM_CONNECTED New State-CONNECTED_STATE
00:15:14.092 Ntf: CHANCON
00:15:14.088 Ntf: CMDDAT Statistic--Data Transfer Information
Error correction 77 LAP-M
Data compression 68 V44
Modulation type 206 V.34
receive speed 16 33600
transmit speed 16 33600
error correction frames sent 0
error correction frames rcvd 0
characters transmitted 0
characters received 0
synchronous frames sent 0
synchronous frames rcvd 0
bad synchronous frames rcvd 0
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
35
Page 36
show modem log (pvdm2)
reject frames sent 0
reject frames rcvd 0
total retransmissions 0
00:13:24.380 Ntf: CMDDAT Statistic--Data Transfer Information
Error correction 77 LAP-M
Data compression 68 V44
Modulation type 206 V.34
receive speed 16 33600
transmit speed 16 33600
error correction frames sent 7
error correction frames rcvd 12
characters transmitted 218
characters received 487
synchronous frames sent 7
synchronous frames rcvd 12
bad synchronous frames rcvd 0
reject frames sent 0
reject frames rcvd 0
total retransmissions 0
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
00:13:44.996 Ntf: CMDREQ
00:13:44.996 Cmd: CMDDAT Statistic--Call Summary Information
00:13:44.992 Ntf: CMDDAT Statistic--Call Summary Information
Disconnect reason 21 Clears previous disconnect reason
Retrain/rate renegotiate reason 0 None
Connection time (hours) 0
Connection time (minutes) 1
Connection time (seconds) 53
Initial receive speed 16 33600
Initial transmit speed 16 33600
Maximum receive speed 16 33600
Maximum transmit speed 16 33600
Minimum receive speed 16 33600
Minimum transmit speed 16 33600
Max retransmit for one frame 1
Total retransmit during connect 0
Minimum EQM 17
Maximum EQM 24
Negative EQMs 0
Minimum SNR 27 31 dB
Maximum SNR 27 31 dB
Retrains requested locally 0
Retrains requested remotely 0
Rate renegotiation req locally 0
Rate renegotiation req remotely 0
00:13:47.140 Ntf: CMDREQ
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
36
Page 37
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
00:13:45.436 Cmd: CMDDAT Statistic--DSP Information
00:13:45.432 Ntf: CMDDAT Statistic--DSP Information
Raw AGC value 94
Last EQM 20
Transmit symbol rate 5 3429
Receive symbol rate 5 3429
Transmit carrier frequency 0 1959 (low)
Receive carrier frequency 0 1959 (low)
Minimum AGC reading 94
Maximum AGC reading 94
Transmit level 13
Remote req tx level reduction 2
SNR 27 31 dB
Transmit non-linear encoding 1 On
Receive non-linear encoding 1 On
Transmit precoding 1 On
Receive precoding 1 On
Transmit shaping 16
Receive shaping 16
Trellis mapping 0 16-state
Transmit pre-emphasis index 0
Raw round trip delay 424
EQM sum low 0
EQM sum medium 0
EQM sum high 0
00:14:17.392 Ntf: CMDDAT Statistic--Digital Impairments
Ditital pad detected 0
RBS pattern 0
Rate drop due to RBS 255
V.90 minimum distance (high) 0
V.90 minimum distance (low) 0
Raw V.90 digital pad val (high) 255
Raw V.90 digital pad val (low) 255
00:14:17.392 Ntf: CMDREQ
00:14:17.392 Cmd: CMDDAT Statistic--V.8bis(proprietary flex) Information
00:14:17.388 Ntf: CMDDAT Statistic--V.8bis(proprietary flex) Information
Negotiation status 74 RLSD on
K56flex/K56Plus negotiation failed
V.90 negotiation not tried
V.90/K56flex negotiation failed
Non-standard V.8bis Octet 13 148 K56flex (generic)
Non-standard V.8bis Octet 14 129 Conexant Conexant-based
Non-standard V.8bis Octet 15 131 K56flex capable, Last byte,
Non-standard V.8bis Octet 16 66 flex version 0x2, Not prototype,
Server, Not last byte,
Non-standard V.8bis Octet 17 0 Not last byte,
Conexant data pump revision 0x0
Non-standard V.8bis Octet 18 0 u-law, x-law not forced,
Not last byte,
Conexant controller revision 0x0
00:14:18.884 Ntf: CMDREQ
00:12:09.636 Cmd: CMDDAT Statistic--Data Transfer Information
00:12:09.632 Ntf: CMDDAT Statistic--Data Transfer Information
Error correction 77 LAP-M
Data compression 68 V44
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
37
Page 38
show modem log (pvdm2)
Modulation type 206 V.34
receive speed 16 33600
transmit speed 16 33600
error correction frames sent 7
error correction frames rcvd 12
characters transmitted 218
characters received 487
synchronous frames sent 7
synchronous frames rcvd 12
bad synchronous frames rcvd 0
reject frames sent 0
reject frames rcvd 0
total retransmissions 0
00:12:10.664 Ntf: CMDREQ
00:12:35.372 Cmd: CMDDAT Statistic--Call Summary Information
00:12:35.368 Ntf: CMDDAT Statistic--Call Summary Information
Disconnect reason 21 Clears previous disconnect reason
Retrain/rate renegotiate reason 0 None
Connection time (hours) 0
Connection time (minutes) 4
Connection time (seconds) 5
Initial receive speed 16 33600
Initial transmit speed 16 33600
Maximum receive speed 16 33600
Maximum transmit speed 16 33600
Minimum receive speed 16 33600
Minimum transmit speed 16 33600
Max retransmit for one frame 1
Total retransmit during connect 0
Minimum EQM 17
Maximum EQM 25
Negative EQMs 0
Minimum SNR 27 31 dB
Maximum SNR 27 31 dB
Retrains requested locally 0
Retrains requested remotely 0
Rate renegotiation req locally 0
Rate renegotiation req remotely 0
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
38
00:12:36.400 Ntf: CMDREQ
00:12:35.596 Cmd: CMDDAT Statistic--DSP Information
00:13:01.796 Ntf: CMDDAT Statistic--DSP Information
Raw AGC value 94
Last EQM 19
Transmit symbol rate 5 3429
Receive symbol rate 5 3429
Transmit carrier frequency 0 1959 (low)
Receive carrier frequency 0 1959 (low)
Minimum AGC reading 94
Maximum AGC reading 94
Transmit level 13
Remote req tx level reduction 2
SNR 27 31 dB
Transmit non-linear encoding 1 On
Receive non-linear encoding 1 On
Transmit precoding 1 On
Receive precoding 1 On
Transmit shaping 16
Receive shaping 16
Trellis mapping 0 16-state
Transmit pre-emphasis index 0
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
Page 39
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Raw round trip delay 424
EQM sum low 0
EQM sum medium 0
EQM sum high 0
00:13:01.788 Ntf: CMDDAT Statistic--Digital Impairments
Ditital pad detected 0
RBS pattern 0
Rate drop due to RBS 255
V.90 minimum distance (high) 0
V.90 minimum distance (low) 0
Raw V.90 digital pad val (high) 255
Raw V.90 digital pad val (low) 255
00:13:02.784 Ntf: CMDREQ
00:13:01.748 Cmd: CMDDAT Statistic--V.8bis(proprietary flex) Information
00:13:01.744 Ntf: CMDDAT Statistic--V.8bis(proprietary flex) Information
Negotiation status 74 RLSD on
K56flex/K56Plus negotiation failed
V.90 negotiation not tried
V.90/K56flex negotiation failed
Non-standard V.8bis Octet 13 148 K56flex (generic)
Non-standard V.8bis Octet 14 129 Conexant Conexant-based
Non-standard V.8bis Octet 15 131 K56flex capable, Last byte,
Non-standard V.8bis Octet 16 66 flex version 0x2, Not prototype,
Server, Not last byte,
Non-standard V.8bis Octet 17 0 Not last byte,
Conexant data pump revision 0x0
Non-standard V.8bis Octet 18 0 u-law, x-law not forced,
Not last byte,
Conexant controller revision 0x0
show modem log (pvdm2)
00:13:02.776 Ntf: CMDREQ
00:06:19.580 Cmd: CMDDAT Statistic--Data Transfer Information
00:06:21.296 Ntf: CMDDAT Statistic--Data Transfer Information
Error correction 77 LAP-M
Data compression 68 V44
Modulation type 206 V.34
receive speed 16 33600
transmit speed 16 33600
error correction frames sent 7
error correction frames rcvd 12
characters transmitted 218
characters received 487
synchronous frames sent 7
synchronous frames rcvd 12
bad synchronous frames rcvd 0
reject frames sent 0
reject frames rcvd 0
total retransmissions 0
00:06:21.300 Ntf: CMDREQ
00:06:21.300 Cmd: CMDDAT Statistic--Call Summary Information
00:06:21.296 Ntf: CMDDAT Statistic--Call Summary Information
Disconnect reason 21 Clears previous disconnect reason
Retrain/rate renegotiate reason 0 None
Connection time (hours) 0
Connection time (minutes) 10
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
39
Page 40
show modem log (pvdm2)
Connection time (seconds) 51
Initial receive speed 16 33600
Initial transmit speed 16 33600
Maximum receive speed 16 33600
Maximum transmit speed 16 33600
Minimum receive speed 16 33600
Minimum transmit speed 16 33600
Max retransmit for one frame 1
Total retransmit during connect 0
Minimum EQM 17
Maximum EQM 25
Negative EQMs 0
Minimum SNR 27 31 dB
Maximum SNR 27 31 dB
Retrains requested locally 0
Retrains requested remotely 0
Rate renegotiation req locally 0
Rate renegotiation req remotely 0
00:07:22.856 Ntf: CMDREQ
00:07:21.828 Cmd: CMDDAT Statistic--DSP Information
00:07:21.824 Ntf: CMDDAT Statistic--DSP Information
Raw AGC value 94
Last EQM 21
Transmit symbol rate 5 3429
Receive symbol rate 5 3429
Transmit carrier frequency 0 1959 (low)
Receive carrier frequency 0 1959 (low)
Minimum AGC reading 94
Maximum AGC reading 94
Transmit level 13
Remote req tx level reduction 2
SNR 27 31 dB
Transmit non-linear encoding 1 On
Receive non-linear encoding 1 On
Transmit precoding 1 On
Receive precoding 1 On
Transmit shaping 16
Receive shaping 16
Trellis mapping 0 16-state
Transmit pre-emphasis index 0
Raw round trip delay 424
EQM sum low 0
EQM sum medium 0
EQM sum high 0
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
00:07:22.176 Ntf: CMDDAT Statistic--Digital Impairments
Ditital pad detected 0
RBS pattern 0
Rate drop due to RBS 255
V.90 minimum distance (high) 0
V.90 minimum distance (low) 0
Raw V.90 digital pad val (high) 255
Raw V.90 digital pad val (low) 255
00:07:22.176 Ntf: CMDREQ
00:07:23.208 Cmd: CMDDAT Statistic--V.8bis(proprietary flex) Information
00:07:24.824 Ntf: CMDDAT Statistic--V.8bis(proprietary flex) Information
Negotiation status 74 RLSD on
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
40
Page 41
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
K56flex/K56Plus negotiation failed
V.90 negotiation not tried
V.90/K56flex negotiation failed
Non-standard V.8bis Octet 13 148 K56flex (generic)
Non-standard V.8bis Octet 14 129 Conexant Conexant-based
Non-standard V.8bis Octet 15 131 K56flex capable, Last byte,
Non-standard V.8bis Octet 16 66 flex version 0x2, Not prototype,
Server, Not last byte,
Non-standard V.8bis Octet 17 0 Not last byte,
Conexant data pump revision 0x0
Non-standard V.8bis Octet 18 0 u-law, x-law not forced,
Not last byte,
Conexant controller revision 0x0
00:07:25.856 Ntf: CMDREQ
Router#
Table 3 describes the major fields shown in the display.
Table 3show modem log Field Descriptions for V12 Modems
FieldDescription
CSMPVDM2-xxDM internal state machine commands.
CmdCommands sent from Cisco IOS software to V12 modems.
NtfNotifications sent from V12 modems to Cisco IOS software.
show modem log (pvdm2)
Related Commands
CommandDescription
show modem configuration
(pvdm2)
show modem operational-status
(pvdm2)
Displays the current modem configuration for V12 digital modems
on PVDM2-xxDM devices.
Displays the current modem operational status for V12 digital
modems on PVDM2-xxDM devices.
show modemcapDisplays the values set for the current modem and lists the modems
for which the router has entries.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
41
Page 42
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
show modem operational-status (pvdm2)
show modem operational-status (pvdm2)
To display performance statistics for individual digital modems on PVDM2-xxDM devices, use the
show modem operational-status command in privileged EXEC mode.
show modem operational-status [slot/port]
Syntax Description
slot/modem number(Optional) Location of the slot and modem number. If these numbers are not
specified, statistics for all connected modems are displayed. You must include
the slash mark.
Command ModesPrivileged EXEC
Command History
ReleaseModification
12.4(11)XWThis command was introduced.
ExamplesThe following example shows details for a V12 digital modem on a PVDMII-xxDM device. A specific
modem, 0/322, is designated.
Router# show modem operational-status 0/322
Modem (0/322) Operational Status:
Error correction 77 LAP-M
Data compression 68 V44
Modulation type 206 V.34
receive speed 16 33600
transmit speed 16 33600
error correction frames sent 7
error correction frames rcvd 12
characters transmitted 218
characters received 487
synchronous frames sent 7
synchronous frames rcvd 12
bad synchronous frames rcvd 0
reject frames sent 0
reject frames rcvd 0
total retransmissions 0
Disconnect reason 21 Clears previous disconnect reason
Retrain/rate renegotiate reason 0 None
Connection time (hours) 0
Connection time (minutes) 19
Connection time (seconds) 15
Initial receive speed 16 33600
Initial transmit speed 16 33600
Maximum receive speed 16 33600
Maximum transmit speed 16 33600
Minimum receive speed 16 33600
Minimum transmit speed 16 33600
Max retransmit for one frame 1
Total retransmit during connect 0
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
42
Page 43
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Minimum EQM 17
Maximum EQM 26
Negative EQMs 0
Minimum SNR 27 31 dB
Maximum SNR 27 31 dB
Retrains requested locally 0
Retrains requested remotely 0
Rate renegotiation req locally 0
Rate renegotiation req remotely 0
Raw AGC value 94
Last EQM 21
Transmit symbol rate 5 3429
Receive symbol rate 5 3429
Transmit carrier frequency 0 1959 (low)
Receive carrier frequency 0 1959 (low)
Minimum AGC reading 94
Maximum AGC reading 94
Transmit level 13
Remote req tx level reduction 2
SNR 27 31 dB
Transmit non-linear encoding 1 On
Receive non-linear encoding 1 On
Transmit precoding 1 On
Receive precoding 1 On
Transmit shaping 16
Receive shaping 16
Trellis mapping 0 16-state
Transmit pre-emphasis index 0
Raw round trip delay 424
EQM sum low 0
EQM sum medium 0
EQM sum high 0
show modem operational-status (pvdm2)
Related Commands
Ditital pad detected 0
RBS pattern 0
Rate drop due to RBS 255
V.90 minimum distance (high) 0
V.90 minimum distance (low) 0
Raw V.90 digital pad val (high) 255
Raw V.90 digital pad val (low) 255
Negotiation status 74 RLSD on
K56flex/K56Plus negotiation failed
V.90 negotiation not tried
V.90/K56flex negotiation failed
Non-standard V.8bis Octet 13 148 K56flex (generic)
Non-standard V.8bis Octet 14 129 Conexant Conexant-based
Non-standard V.8bis Octet 15 131 K56flex capable, Last byte,
Non-standard V.8bis Octet 16 66 flex version 0x2, Not prototype,
Server, Not last byte,
Non-standard V.8bis Octet 17 0 Not last byte,
Conexant data pump revision 0x0
Non-standard V.8bis Octet 18 0 u-law, x-law not forced,
Not last byte,
Conexant controller revision 0x0
Router#
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
43
Page 44
show modem operational-status (pvdm2)
CommandDescription
show modem configuration
(pvdm2)
show modem log (pvdm2)Displays the modem history event status performed on a manageable
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Displays the current modem configuration for digital V12 modems
on PVDM2-xxDM devices.
modem or group of modems.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
44
Page 45
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
show modem version (pvdm2)
To display version information about the modem firmware, controller, and boot code, use the show
modem version command in Privileged EXEC mode.
show modem version
Syntax DescriptionThis command has no arguments or keywords.
Command ModesPrivileged EXEC
show modem version (pvdm2)
Command History
ReleaseModification
12.4(11)XWThis command was introduced.
Usage GuidelinesThis command is useful for verifying the version of modem firmware running on the system before or
after a modem firmware upgrade. If there is a “-/-” in the DSP REV field, you cannot use the spe
configuration commands for firmware download on that modem.
ExamplesThe following example displays modem version information about PVDM2-xxDM digital modems. This
example specifically shows information about a Cisco 2821 router with three PVDM2-36DMs,
high-density pvdms holding 36 digital modems each.
Table 4 describes the significant fields shown in the displays of the show modem version command.
Table 4show modem version Field Descriptions
FieldDescription
PVDMPVDM slot number where PVDM2-xxDM is present.
HW VersionHardware revision number of PVDM2-xxDM.
FPGA VersionFPGA version loaded in the PVDM2-xxDM.
NiOSThe version number of the NiOS core soft processor in
Modem Slot and port number for the specified modem.
PCI ClassidPCI class id of the CSM V12 chipset present in PVDM2-xxDM.
Bootrom RevBootrom revision number of PVDM2-xxDM.
Diag ResultInternal diagnostics result.
FirmwareCSM V12 Firmware version
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
PVDM2-xxDM.
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
46
Page 47
Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
Feature Information for Digital Modem PVDM2s
Feature Information for Digital Modem PVDM2s
Table 5 lists the release history for this feature.
Not all commands may be available in your Cisco IOS software release. For release information about a
specific command, see the command reference documentation.
Use Cisco Feature Navigator to find information about platform support and software image support.
Cisco Feature Navigator enables you to determine which Cisco IOS and Catalyst OS software images
support a specific software release, feature set, or platform. To access Cisco Feature Navigator, go to
http://www.cisco.com/go/cfn. An account on Cisco.com is not required.
NoteTable 5 lists only the Cisco IOS software release that introduced support for a given feature in a given
Cisco IOS software release train. Unless noted otherwise, subsequent releases of that Cisco IOS
software release train also support that feature.
Table 5Feature Information for Digital Modem PVDM2s
Feature NameReleasesFeature Information
PVDM2-12DM, PVDM2-24DM,
PVDM2-36DM
Digital Modem Support and Modem Resource
Pooling
12.4(9)TThis feature consists of digital modems in a PVDM2
package. Three models are available with different numbers
of modems in the package: 12 modems, 24 modems, and 36
modems.
12.4(11)XW
12.4(20)T
Provides support on certain HWIC and VIC interface cards.
Provides modem pooling and modem recovery features.
The following section provides information about HWIC
and VIC support:
• Network Interfaces, page 2
The following section provides information about the
modem pooling feature:
• Configuring Modem Pooling, page 11
The following section provides information about the
modem recovery feature:
• Configuring Modem Recovery, page 12
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
47
Page 48
Feature Information for Digital Modem PVDM2s
CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is
a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco
Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS,
iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networkers,
Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient,
and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (0711R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and
figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and
coincidental.