Cisco Catalyst 2960-L Series, Catalyst WS-C2960L-8TS-LL, Catalyst WS-C2960L-8PS-LL, Catalyst WS-C2960L-16TS-LL, Catalyst WS-C2960L-16PS-LL Hardware Installation Manual

Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide

First Published: 2016-09-30
Americas Headquarters
Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Contents

CONTENTS
PREFACE
CHAPTER 1
Preface ix
Document Conventions ix
Related Documentation x
Obtaining Documentation and Submitting a Service Request xi
Product Overview 1
Switch Models 1
Front Panel 2
PoE Ports 3
10/100/1000 Ports 4
Console Ports 4
SFP Module Slots 5
LEDs 5
System LED 6
Port LEDs and Modes 7
PoE LED 8
Console LEDs 8
CHAPTER 2
ii
Port LEDs 8
Rear Panel 9
Internal Power Supply 10
Security Slot 10
Network Configurations 11
Switch Installation 13
Safety Warnings 13
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
Box Contents 16
Tools and Equipment 17
Installation Guidelines 17
Verifying Switch Operation 18
Mounting the Switch 18
Mounting on a Desk or Shelf Without Mounting Screws 18
On a Desk, Shelf, or Wall (with Mounting Screws) 19
Desk- or Shelf-Mounting 19
Under a Desk- or Shelf-Mounting 20
Wall-Mounting 21
With a Mounting Tray 23
Mounting Tray with Screws 23
Mounting Tray with a Magnet 25
Contents
CHAPTER 3
In a Rack 27
On a DIN Rail 29
Attaching the DIN-Mount Tray to the Switch 29
Mounting the Switch on a DIN Rail 30
Removing the Switch from a DIN Rail 31
Installing the Power Cord Retainer (Optional) 32
Installing the Cable Guard (Optional) 35
Installing SFP Modules 38
Installing an SFP Module 38
Removing an SFP Module 39
10/100/1000 PoE and PoE+Port Connections 40
10/100/1000 Port Connections 41
Auto-MDIX Connections 41
Troubleshooting 43
Diagnosing Problems 43
Switch POST Results 43
Switch LEDs 43
Switch Connections 43
Bad or Damaged Cable 43
Ethernet and Fiber-Optic Cables 44
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
iii
Contents
Link Status 44
10/100/1000 Port Connections 44
10/100/1000 PoE+ Port Connections 44
SFP Module 45
Interface Settings 45
Ping End Device 45
Spanning Tree Loops 45
Switch Performance 46
Speed, Duplex, and Autonegotiation 46
Autonegotiation and Network Interface Cards 46
Cabling Distance 46
Finding the Switch Serial Number 46
APPENDIX A
APPENDIX B
APPENDIX C
Technical Specifications 49
Physical Specifications 49
Environmental Specifications 50
Power Requirements 50
PoE Power Consumption 51
Connector and Cable Specifications 53
Connector Specifications 53
10/100/1000 Ports (Including PoE) 53
SFP Module Connectors 53
Cables and Adapters 54
SFP Module Cables 54
Cable Pinouts 55
Console Port Adapter Pinouts 56
Configuring the Switch 59
Configuring the Switch Using the Configuration Setup Wizard 59
Quick Setup: Accessing the Configuration Setup Wizard 59
Completing the Configuration Setup Wizard 61
Configuring the Switch Using the CLI 61
Accessing the CLI Through the Console Port 61
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
iv
Connecting the RJ-45 Console Port 62
Connecting the USB Console Port 62
Installing the Cisco Microsoft Windows USB Device Driver 63
Installing the Cisco Microsoft Windows XP USB Driver 63
Installing the Cisco Microsoft Windows 2000 USB Driver 64
Installing the Cisco Microsoft Windows 7 USB Driver 65
Uninstalling the Cisco Microsoft Windows USB Driver 65
Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver 65
Uninstalling the Cisco Microsoft Windows 7 USB Driver 66
Contents
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
v
Contents
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
vi
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright©1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED "AS IS" WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.
All printed copies and duplicate soft copies of this document are considered uncontrolled. See the current online version for the latest version.
Cisco has more than 200 offices worldwide. Addresses and phone numbers are listed on the Cisco website at www.cisco.com/go/offices.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com
go trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any
other company. (1721R)
©
Cisco Systems, Inc. All rights reserved.

Preface

Document Conventions , on page ix
Related Documentation, on page x
Obtaining Documentation and Submitting a Service Request, on page xi

Document Conventions

This document uses the following conventions:
DescriptionConvention
^ or Ctrl
Italic font
...
|
[x | y]
{x | y}
Both the ^ symbol and Ctrl represent the Control (Ctrl) key on a keyboard. For example, the key combination ^D or Ctrl-D means that you hold down the Control key while you press the D key. (Keys are indicated in capital letters but are not case sensitive.)
Commands and keywords and user-entered text appear in bold font.bold font
Document titles, new or emphasized terms, and arguments for which you supply values are in italic font.
Terminal sessions and information the system displays appear in courier font.Courier font
Bold Courier font indicates text that the user must enter.Bold Courier font
Elements in square brackets are optional.[x]
An ellipsis (three consecutive nonbolded periods without spaces) after a syntax element indicates that the element can be repeated.
A vertical line, called a pipe, indicates a choice within a set of keywords or arguments.
Optional alternative keywords are grouped in brackets and separated by vertical bars.
Required alternative keywords are grouped in braces and separated by vertical bars.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
ix

Related Documentation

Preface
DescriptionConvention
[x {y | z}]
Nested set of square brackets or braces indicate optional or required choices within optional or required elements. Braces and a vertical bar within square brackets indicate a required choice within an optional element.
string
A nonquoted set of characters. Do not use quotation marks around the string or the string will include the quotation marks.
Nonprinting characters such as passwords are in angle brackets.< >
Default responses to system prompts are in square brackets.[ ]
!, #
An exclamation point (!) or a pound sign (#) at the beginning of a line of code indicates a comment line.
Reader Alert Conventions
This document may use the following conventions for reader alerts:
Note
Means reader take note. Notes contain helpful suggestions or references to material not covered in the manual.
Tip
Means the following information will help you solve a problem.
Caution
Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.
Timesaver
Warning
Means the described action saves time. You can save time by performing the action described in the paragraph.
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071
SAVE THESE INSTRUCTIONS
Related Documentation
• Cisco SFP modules documentation, including compatibility matrixes, located at:
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
x
Preface

Obtaining Documentation and Submitting a Service Request

http://www.cisco.com/en/US/products/hw/modules/ps5455/tsd_products_support_series_home.html
• Cisco Validated Designs documents at this URL:
http://www.cisco.com/go/designzone
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/c/en/us/td/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
xi
Obtaining Documentation and Submitting a Service Request
Preface
xii
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
CHAPTER 1

Product Overview

The Cisco Catalyst 2960-L Series switches are fixed-configuration, Gigabit Ethernet switches that provide entry-level enterprise-class Layer 2 access for branch offices, conventional workspace, and out-of-wiring closet applications.
Cisco Catalyst 2960-L Series switches provide support for the following features:
• 8 or 16 Gigabit Ethernet ports with line-rate forwarding performance
• Two Gigabit Small Form-Factor Pluggable (SFP) uplinks
• Power over Ethernet Plus (PoE+) support with up to 370W of PoE budget and Persistent PoE
• Fanless operation with operational temperature up to 45°C for deployment outside the wiring closet
• Reduced power consumption and advanced energy management
• RJ-45 and USB Mini-Type B console ports
• USB Type A port supports file system
Switch Models, on page 1
Front Panel, on page 2
Rear Panel, on page 9
Network Configurations, on page 11

Switch Models

Table 1: Cisco Catalyst 2960-L 8-Port and 16-Port Switch Models and Description
Switch Model
DescriptionSoftware
Image
Lan LiteWS-C2960L-8TS-LL
Lan LiteWS-C2960L-8PS-LL
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
8 10/100/1000 Ethernet ports; 2 1-Gigabit small form-factor pluggable (SFP) module uplink slots.
8 10/100/1000 Power over Ethernet plus (PoE+) ports (PoE budget of 67W); 2 1-Gigabit small form-factor pluggable (SFP) module uplink slots.
1

Front Panel

Product Overview
Front Panel
Switch Model
Image
Lan LiteWS-C2960L-16TS-LL
Lan LiteWS-C2960L-16PS-LL
This section describes the front panel components of a 8-port and 16-port Cisco Catalyst 2960-L switch.
• 8 or 16 downlink Ethernet ports of one of these types:
• 10/100/1000
• 10/100/1000 PoE+
• 2 SFP module ports
• RJ-45 console port
• USB mini-Type B (console) port
DescriptionSoftware
16 10/100/1000 Ethernet ports; 2 1-Gigabit small form-factor pluggable (SFP) module uplink slots.
16 10/100/1000 Power over Ethernet plus (PoE+) ports (PoE budget of 120W); 2 1-Gigabit small form-factor pluggable (SFP) module uplink slots.
• USB Type A port
• LEDs
Figure 1: Front Panel of an 8-Port Cisco Catalyst 2960-L PoE Switch
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
2
Product Overview
Note
The yellow color marking around the ports indicates that the switch is a PoE switch.

PoE Ports

System LEDs5Mode button1
8 10/100/1000 PoE+ ports6USB Type A port2
SFP module slots7RJ-45 Console Port3
4
USB mini-Type B (console) port
Figure 2: Front Panel of a 16-Port Cisco Catalyst 2960-L PoE Switch
PoE Ports
System LEDs5Mode button1
6USB Type A port2
16 10/100/1000 PoE+ ports
SFP module slots7RJ-45 Console Port3
4
USB mini-Type B (console) port
The ports provide PoE support for devices compliant with IEEE 802.3af and IEEE 802.3at and also provide PoE support for Cisco IP Phones and Cisco Aironet Access Points. The PoE switch ports are Power Source equipment (PSE) and Power Device (PD) capable and source power to PD devices connected to the downlink ports. A switch can source POE power of up to 30.8W per port.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
3

10/100/1000 Ports

Depending on the switch model and the number of PoE ports, the maximum switch power output varies between 91.66 W to 150.11 W. On a per-port basis, you can control whether or not a port automatically provides power when an IP phone or an access point is connected.
The PoE ports use RJ-45 connectors with Ethernet pinouts. The 10BASE-T, 100BASE-TX, 1000BASE-T traffic requires Category 5 or Category 5e twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable.
10/100/1000 Ports
The 10/100/1000 ports use RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 10BASE-T, 100BASE-TX, 1000BASE-T traffic requires Category 5 or Category 5e twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable.

Console Ports

The console ports connect the switch to a PC running Microsoft Windows or to a terminal server.
• RJ-45 console port (EIA/TIA-232). The RJ-45 console port connection uses an RJ-45-to-DB-9 female
Product Overview
cable.
• USB mini-Type B console port (5-pin connector).
If you use the USB mini-Type B console port, the Cisco Windows USB device driver must be installed on any PC connected to the console port (for operation with Microsoft Windows). Mac OS X or Linux do not require special drivers.
The 4-pin mini-Type B connector resembles the 5-pin mini-Type B connectors. They are not compatible. Use only the 5-pin mini-Type B.
This illustration shows a 5-pin mini-Type B USB port.
Figure 3: USB Mini-Type B Port
With the Cisco Windows USB device driver, you can connect and disconnect the USB cable from the console port without affecting Windows HyperTerminal operations.
The console output always goes to both the RJ-45 and the USB console connectors, but the console input is active on only one of the console connectors at any one time. The USB console takes precedence over the RJ-45 console. When a cable is connected into the USB console port, the RJ-45 console port becomes inactive. Conversely, when the USB cable is disconnected from the USB console port, the RJ-45 port becomes active.
You can use the command-line interface (CLI) to configure an inactivity timeout which reactivates the RJ-45 console if the USB console has been activated and no input activity has occurred on the USB console for a specified time.
After the USB console deactivates due to inactivity, you cannot use the CLI to reactivate it. Disconnect and reconnect the USB cable to reactivate the USB console. For information on using the CLI to configure the USB console interface, see the software guide.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
4
Product Overview

SFP Module Slots

The switch has two 1G SFP module slots. The SFP modules provide copper or fiber-optic connections to other devices. These transceiver modules are field replaceable, and provide the uplink interfaces when installed in an SFP module slot. The SFP modules have LC connectors for fiber-optic connections or RJ-45 connectors for copper connections. The SFP slots support only SFP modules.
For Cisco SFP modules documentation, including compatibility matrixes, refer to this URL:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
Table 2: Port mapping for Cisco Catalyst 2960-L 24-Port Switch models
SFP Module Slots
10-GigabitEthernet ports1-GigabitEthernet ports
TenGigabitEthernet0/1GigabitEthernet0/25
TenGigabitEthernet0/2GigabitEthernet0/26
TenGigabitEthernet0/3GigabitEthernet0/27
TenGigabitEthernet0/4GigabitEthernet0/28

LEDs

Table 3: Port mapping for Cisco Catalyst 2960-L 48-Port Switch models
10-GigabitEthernet ports1-GigabitEthernet ports
TenGigabitEthernet0/1GigabitEthernet0/49
TenGigabitEthernet0/2GigabitEthernet0/50
TenGigabitEthernet0/3GigabitEthernet0/51
TenGigabitEthernet0/4GigabitEthernet0/52
Note
If you insert a 10G SFP+ in to a 1G SFP module slot and vice versa, you need to clear the existing configuration by running the default-interface <interface-number> command on the mapped ports. For more information about the command, refer to the Software Configuration Guide.
You can use the switch system and port LEDs to monitor switch activity and performance.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
5
System LED
Product Overview
Figure 4: Switch LEDs
System LED
1
Only on switch models that support PoE.
Amber
4SYST LED (system)1
PoE LED
1
Console LED5STAT LED (status)2
Port LEDs6SPEED LED3
System StatusColor
System is not powered on.Off
System is operating normally.Green
System is receiving power but is not operating properly.
POST is in progress.Blinking Green
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
6
Product Overview
Port LEDs and Modes
The port and module slots each has a port LED. As a group or individually, the LEDs display information about the switch and about the individual ports.
Table 4: Port Mode LEDs
Port LEDs and Modes
DescriptionPort ModeLED
The port status. This is the default mode.Port statusSTAT
Port speedSPEED
The port operating speed: 10, 100, or 1000 Mb/s.
The PoE status.PoE port powerPoE
To select or change a mode, press the Mode button until the desired mode is highlighted. When you change port modes, the meanings of the port LED colors also change.
Table 5: Meanings of LED Colors in Different Modes
DescriptionColorPort ModeLED
No link or port is administratively shut down.OffPort statusSTAT
Link is present.Green
Activity. Port is sending or receiving data.Blinking green
Alternating green amber
Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment errors are monitored for link faults.
Amber
Port is blocked by Spanning Tree Protocol (STP) and is not forwarding data. After a port is reconfigured, the port LED is amber for up to 30 seconds as STP searches for loops.
Port is blocked by STP and is not sending data.Blinking amber
Port speedSPEED
Green
Port is operating at 10 Mb/s.Off
Port is operating at 100 Mb/s.
2
Port is operating at 1000 Mb/s.Blinking green
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
7
PoE LED
Product Overview
DescriptionColorPort ModeLED
PoE LED
PoE
2
Even if the PoE mode is not selected, the LED shows PoE problems when they are detected. The PoE LED is only on the switches that support PoE.
PoE port power
Applies only to RJ-45 ports.
Off
Green
Alternating green amber
DescriptionColor
PoE mode is not selected.Off
PoE mode is selected. Ports are functioning correctly.Green
PoE is off. If the powered device is receiving power from an AC power source, the PoE port LED is off even if the powered device is connected to the switch port.
PoE is on. The port LED is green only when the switch port is providing power.
PoE is denied because providing power to the powered device will exceed the switch power capacity.
PoE for the port is disabled. By default, PoE is enabled.Amber
PoE is off due to a fault.Blinking Amber
Console LEDs
Port LEDs
Blinking amber
The console LEDs show which console port is in use.
If you connect a cable to a console port, the switch automatically uses that port for console communication. If you connect two console cables, the USB-mini console port has priority.
RJ-45 ports and SFP-module slots have port LEDs. These LEDs, as a group or individually, provide information about the switch and about the individual ports.
• PoE mode is not selected
• At least one of the 10/100 or 10/100/100 PoE ports has been denied power
• At least one of the ports has a PoE fault
DescriptionColorLED
USB-mini console port is active.GreenUSB-mini console port
Off
Port is not active.
RJ-45 console port is active.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
8
Product Overview

Rear Panel

DescriptionLED Color
No link or port was administratively shut down.Off
Link present but is not sending or receiving data.Green
Rear Panel
Blinking green
Alternating green-amber
Activity. Port is sending or receiving data.
Note
Link fault. Error frames can affect connectivity, and errors such as excessive collisions, CRC errors, and alignment and jabber errors are monitored for link faults.
Note
Amber
Port is blocked by Spanning Tree Protocol (STP) and is not forwarding data. After a port is reconfigured, the port LED is amber for up to 30 seconds as STP searches for loops.
Note
• A security slot
• An AC power connector
• A loop (for the optional power cord retainer)
Currently this is not supported for SFP ports.
Currently this is not supported for SFP ports.
Currently this is not supported for SFP ports.
• Heat sink fins (PoE models only)
Figure 5: Rear Panel of a Non-PoE Switch
An AC power connector2
3Security Slot1
A loop (for the optional power cord retainer)
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
9

Internal Power Supply

Product Overview
Figure 6: Rear Panel of a PoE Switch
Internal Power Supply
All the switches are powered through their internal power supplies. The internal power supply is an autoranging unit that supports input voltages between 100 and 240 VAC (max of 90V to 264V). The AC frequency range of the power supply is 50Hz~60Hz. Plug the AC power cord into the AC power connector and into an AC power outlet.

Security Slot

The switches have security slots on the rear panel. You can install an optional cable lock, such as the type that is used to secure a laptop computer, to secure the switch.
3Security Slot1
A loop (for the optional power cord retainer)
Heat sink fins4An AC power connector2
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
10
Product Overview

Network Configurations

Figure 7: Switch Rear Panel
Network Configurations
See the switch software configuration guide for network configuration concepts and examples of using the switch to create dedicated network segments and interconnecting the segments through Fast Ethernet and Gigabit Ethernet connections.
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
11
Network Configurations
Product Overview
Cisco Catalyst 2960-L Series 8-Port and 16-Port Switch Hardware Installation Guide
12
Loading...
+ 56 hidden pages