Chauvet DJ EVE E-100Z Users Manual

Page 1
User Manual V3
Page 2
TABLE OF CONTENTS
TABLE OF CONTENTS
1. Before You Begin ....................................................................... 1
What Is Included ........................................................................................... 1
Unpacking Instructions.................................................................................. 1
Claims ................................................................................................................ 1
Text Conventions .......................................................................................... 1
Symbols ........................................................................................................ 1
Disclaimer ..................................................................................................... 1
Product at a Glance ...................................................................................... 2
Safety Notes.................................................................................................. 2
2. Introduction ................................................................................ 3
Product Overview.......................................................................................... 3
Product Dimensions ...................................................................................... 4
3. Setup ........................................................................................... 5
AC Power...................................................................................................... 5
Fuse Replacement ............................................................................................. 5
Power Linking..................................................................................................... 5
Mounting ....................................................................................................... 6
Orientation.......................................................................................................... 6
Rigging ............................................................................................................... 6
4. Operation .................................................................................... 7
Control Panel Operation................................................................................ 7
Menu Map ..................................................................................................... 7
Configuration (DMX) ..................................................................................... 7
Starting Address................................................................................................. 7
D-Fi USB Connectivity .................................................................................. 7
Configuration (D-Fi USB) ................................................................................... 8
D-Fi USB DIP Switch Channels............................................................................... 8
DMX Channel Assignments and Values ....................................................... 9
3-CH................................................................................................................... 9
1-CH................................................................................................................... 9
Configuration (Standalone) ........................................................................... 9
Dimmer............................................................................................................... 9
Strobe................................................................................................................. 9
Dimmer Speed Mode ......................................................................................... 9
Fan Mode ........................................................................................................... 9
5. Maintenance................................................................................ 11
6. Technical Specifications ........................................................... 12
Returns............................................................................................ 13
Contact Us ...................................................................................... 14
EVE E-100Z V3 User Manual Rev. 2
Page 3
BEFORE YOU BEGIN

1. BEFORE YOU BEGIN

What Is Included

EVE E-100Z V3
Gel Frame
Framing Shutters
Glass Gobo Holder

Unpacking Instructions

Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.

Claims

If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Text Conventions

CONVENTION MEANING
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
<ENTER> A key to be pressed on the product’s control panel
ON A value to be entered or selected
Steel Gobo Holder
Seetronic Powerkon Power Cord
Warranty Card
Quick Reference Guide

Symbols

SYMBOL MEANING
Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.

Disclaimer

Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com
The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.
© Copyright 2018 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, D-Fi USB, and EVE E-100Z V3 are registered trademarks or trademarks of
Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
.
EVE E-100Z V3 User Manual Rev. 2
Page 1 of 14
Page 4

Product at a Glance

BEFORE YOU BEGIN
Use on Dimmer
Outdoor Use
Sound-Active
DMX
Master/Slave

Safety Notes

Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect the product from the power source before cleaning or replacing the fuse.
Avoid direct eye exposure to the light source while the product is on.
Make sure the power cord is not crimped or damaged.
Never disconnect the product from power cord by pulling or tugging on the cord.
If mounting the product overhead, always secure to a fastening device using a safety cable.
Make sure there are no flammable materials close to the product when operating.
Do not touch the product’s housing when operating because it may be very hot.
Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product.
The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose the product to rain or moisture.
Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the product’s housing are blocked.
Never connect the product to a dimmer.
Make sure to replace the fuse with another of the same type and rating.
Never carry the product from the power cord or any moving part. Always use the hanging/ mounting bracket.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair the product. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  
 
Auto Programs
Auto-ranging Power Supply
Replaceable Fuse
User-Serviceable
 
Page 2 of 14
Keep this User Manual for future use. If you sell the product to someone else, be sure that they also receive this document.
EVE E-100Z V3 User Manual Rev. 2
Page 5
INTRODUCTION
Focus Knob
Zoom Knob
DMX
In/Out
Fuse Holder
Power In
Gel Frame
Framing Shutter x4
Menu Buttons
Power Out
LED Display
Gel Frame Holder
D-Fi USB Port
Gobo Holder Thumbscrew
Safety
Loop

2. INTRODUCTION

Product Overview

WARNING! DO NOT plug anything other than a D-Fi USB into the USB port. Doing so may cause damage to the product.
EVE E-100Z V3 User Manual Rev. 2
Page 3 of 14
Page 6

Product Dimensions

16.9 in
430 mm
24 in
611 mm
7.2 in
183 mm
INTRODUCTION
Page 4 of 14
EVE E-100Z V3 User Manual Rev. 2
Page 7
SETUP
1st Product
2
nd
Product
3
rd
Product
Additional
Products
Power
Source

3. SETUP

AC Power

The EVE E-100Z V3 an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non­use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement

1. Disconnect the product from power.
2. Using a flat-head screwdriver, loosen the fuse holder and pull straight out.
3. Remove the blown fuse from the holder.
4. Replace with a fuse of the exact same type and rating.
5. Insert the fuse holder back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse.

Power Linking

The product provides power linking via the Edison outlet located in the back of the product. Please see the diagram below for further explanation.
Power Linking Diagram
You can power link up to 9 EVE E-100Z V3 products on 120 VAC or up to 16 EVE E-100Z V3 products on 230 VAC.
EVE E-100Z V3 User Manual Rev. 2
Page 5 of 14
Page 8
SETUP
Mounting Bracket
Safety Cable
(such as CH-05 from
Chauvet)
Mounting Clamp
(such as CLP-15 or CLP-15N
from Chauvet)
Bracket
Adjustment Knob

Mounting

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.

Orientation

The EVE E-100Z V3 may be mounted in any position; however, make sure adequate ventilation is provided around the product.

Rigging

Before deciding on a location, always make sure there is easy access to the product for maintenance and programming purposes.
Make sure adequate ventilation is provided around the product.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight. (see the Technical Specifications
When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
When power linking multiple products, mount the products close enough for power linking cables to reach.
The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs.
Mounting Diagram
)
Page 6 of 14
EVE E-100Z V3 User Manual Rev. 2
Page 9
OPERATION

4. OPERATION

Control Panel Operation

To access the control panel functions, use the four buttons located underneath the display. Please refer to the Product Overview
BUTTON FUNCTION
<MENU> Press to find an operation mode or to back out of the current menu option
<UP> Press to scroll up the list of options or to find a higher value
<DOWN> Press to scroll down the list of options or to find a lower value
<ENTER> Press to activate a menu option or a selected value

Menu Map

MODE PROGRAMMING LEVELS DESCRIPTION
DMX Mode
Dimmer U--
Dimmer
Speed Mode
Fan FAN
to see the button locations on the control panel.
1-CH 3-CH
dIM
d 1–512 Selects DMX personality and starting address
d000–255 Dimmer level S000–255 Strobe speed
OFF dIM1 dIM2 dIM3
AUTO Fan speed according to product temperature
ON Fan always on
Dimmer speed settings, off, fast, medium, or slow

Configuration (DMX)

The EVE E-100Z V3 works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website http://www.chauvetlighting.com/downloads/
DMX_Primer_rev05_WO.pdf.

Starting Address

When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s channels.
The EVE E-100Z V3 uses up to 3 DMX channels, which defines the highest configurable address as 510. If you are not familiar with the DMX protocol, download the DMX Primer from www.chauvetdj.com To select the starting address, do the following:
1. Press <MENU> repeatedly until 1-CH or 3-CH shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select the starting address, from d 1–512.
4. Press <ENTER>.
.

D-Fi USB Connectivity

The PN is able to become a D-Fi wireless receiver/transmitter with the use of the D-Fi USB from Chauvet DJ. Simply set the product's DMX Personality and DMX Address, set the DIP switch D-Fi receiving/
transmitting channel, then plug it into the D-Fi USB port.
WARNING! DO NOT plug anything other than a D-Fi USB into the USB port. Doing so may cause damage to the product.
Once plugged in, the D-Fi USB will take over the product. Wired DMX and manual display control / menu buttons will be unavailable until you unplug the D-Fi USB. The priority levels are:
1. D-Fi USB
2. Wired DMX
3. Manual Digital Display/Menu Buttons
EVE E-100Z V3 User Manual Rev. 2
Page 7 of 14
Page 10

Configuration (D-Fi USB)

1. Set the DMX Personality and DMX address on the EVE E-100Z V3.
2. Use the Chart provided to set BOTH:
the Channel, and then
The Receiving or Transmitting option
NOTE: DIP Switch 5
D-Fi USB DIP Switch Channels
is for Transmitting OR Receiving, please choose carefully.
OPERATION
Page 8 of 14
EVE E-100Z V3 User Manual Rev. 2
Page 11
OPERATION

DMX Channel Assignments and Values

3-CH

CHANNEL FUNCTION VALUE PERCENT/SETTING
1 Dimmer 000 255 0–100%
000
2Strobe
3 Dimmer Speed Mode
010 No function
011
255 Strobe (slow to fast)
000
051 Dimmer speed set from display
052
101 Dimmer speed mode Off
102
152 Dimmer speed mode 1 - fast
153
203 Dimmer speed mode 2 - medium
204
255 Dimmer speed mode 3 - slow

1-CH

CHANNEL FUNCTION VALUE PERCENT/SETTING
1 Dimmer 000 255 0–100%

Configuration (Standalone)

Set the product in one of the standalone modes to control without a DMX controller.
Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.

Dimmer

To set the dimmer level on the EVE E-100Z V3, follow the instructions below:
1. Press <MENU> repeatedly until U-- shows on the display.
2. Press <ENTER>. Repeat until d000–255 shows on the display.
3. Use <UP> or <DOWN> to increase or decrease the dimmer value.
4. Press <ENTER> to save the value.
5. Press <MENU> to exit the mode.

Strobe

To set the strobe speed on the EVE E-100Z V3, do the following:
1. Press <MENU> repeatedly until U-- shows on the display.
2. Press <ENTER>. Repeat until S000–255 shows on the display.
3. Use <UP> or <DOWN> to increase or decrease the strobe speed.
4. Press <ENTER> to save the value.
5. Press <MENU> to exit the mode.

Dimmer Speed Mode

To set the dimmer speed mode of the EVE E-100Z V3, follow the instructions below:
1. Press <MENU> repeatedly until dIM shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select the dimmer speed mode, from OFF, dIM1 (fast), dIM2 (medium), or dIM3 (slow).
4. Press <ENTER>.

Fan Mode

To set the fan mode of the EVE E-100Z V3, do the following:
1. Press <MENU> repeatedly until FAN shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select the fan mode, from AUTO (the fan speed will be set by the product temperature) or ON (the fan will always be on).
4. Press <ENTER>.
EVE E-100Z V3 User Manual Rev. 2
Page 9 of 14
Page 12
OPERATION

Master/Slave Mode (Wired)

The Master/Slave mode allows a single EVE E-100Z V3 product (the “master”) to control the actions of one or more EVE E-100Z V3 products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in Stand-Alone, while the slave products will be set to operate in Slave mode. Once set and connected, the slave products will operate in unison with the master product.
Configure the products as indicated below.
Slave products:
1. Press <MENU> repeatedly until 1-CH or 3-CH shows on the display.
2. Press <ENTER> to accept.
3. Set the DMX address to d 1.
4. Connect the DMX input of the first slave product to the DMX output of the master product.
5. Connect the DMX input of the subsequent slave products to the DMX output of the previous slave product.
6. Finish setting and connecting all the slave products.
Master product:
1. Set the master product to operate in Stand-Alone mode.
2. Make the master product the first product in the DMX daisy chain.
Configure all the slave products before connecting the master to the daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master.
Do not connect more than 31 slaves to the master.

Master/Slave Mode (D-Fi USB)

The D-Fi USB allows a single EVE E-100Z V3 product (the “master”) to control the actions of one or more EVE E-100Z V3 products (the “slaves”) without the need of a DMX controller or DMX cables. The master (transmitter) product will be set to operate in Stand-Alone mode, while the slave (receiver) products will be set to operate in Slave mode. Once set and connected, the slave products will operate in unison with the master product.
Configure the products as indicated below.
Slave products:
1. Press <MENU> repeatedly until 1-CH or 3-CH shows on the display.
2. Press <ENTER> to accept.
3. Set the DMX address to d 1.
4. Set the D-Fi USB to receive on a specific channel, 1–16.
5. Plug in the D-Fi USB.
6. Finish setting and connecting all the slave products.
Master product:
1. Set the master product to operate in Stand-Alone mode.
2. Set the D-Fi USB to transmit on the D-Fi channel the slaves are receiving on.
3. Plug in the D-Fi USB.
All products must be set to the same DMX personality, DMX address, and D-Fi channel.
Configure all the slave products before configuring the master to transmit.
Never connect a DMX controller to a D-Fi channel configured for Master/Slave operation because the controller may interfere with the signals from the master.
Page 10 of 14
EVE E-100Z V3 User Manual Rev. 2
Page 13
MAINTENANCE

5. MAINTENANCE

Product Maintenance

Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1. Unplug the product from power.
2. Wait until the product is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6. Softly drag any dirt or grime to the outside of the transparent surface.
7. Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
EVE E-100Z V3 User Manual Rev. 2
Page 11 of 14
Page 14
TECHNICAL SPECIFICATIONS

6. TECHNICAL SPECIFICATIONS

Dimensions and Weight
LENGTH WIDTH HEIGHT WEIGHT
24 in (611 mm) 7.2 in (183 mm) 16.9 in (430 mm) 12.6 lb (5.7 kg)
Note: Dimensions in inches rounded to the nearest decimal digit. Power
POWER SUPPLY TYPE RANGE VOLTAGE SELECTION
Switching (internal) 100 to 240 VAC, 50/60 Hz Auto-ranging
PARAMETER 120 V, 60 HZ 230 V, 50 HZ
Consumption 106 W 103 W
Operating Current 0.9 A 0.5 A
Power linking current (products) 13.6 A (9 products) 13.6 A (16 products)
Fuse T 2 A, 250 V T 2 A, 250 V
POWER I/O U.S./WORLDWIDE UK/EUROPE
Power input connector Seetronic Powerkon Seetronic Powerkon
Power output connector Seetronic Powerkon Seetronic Powerkon
Power Cord plug Edison (U.S.) Local Plug
Light Source
TYPE COLOR QUANTITY POWER CURRENT LIFESPAN
LED Warm white 1 100 W 2.3 A 50,000 hours
Photometrics
PARAMETER VALUE
Strobe Rate 0 to 30 Hz
Zoom Angle 14° to 30° Illuminance @ 2 m (14°) 15,100 lux Illuminance @ 5 m (14°) 3,238 lux Illuminance @ 2 m (30°) 3,800 lux Illuminance @ 5 m (30°) 829 lux
Thermal
MAXIMUM EXTERNAL TEMPERATURE COOLING SYSTEM
104 °F (40 °C) Fan-assisted convection
DMX
I/O CONNECTOR CHANNEL RANGE
3-pin XLR 1 or 3
Ordering
PRODUCT NAME ITEM CODE UPC NUMBER
EVE E-100Z V3 03051188 781462215361
Page 12 of 14
EVE E-100Z V3 User Manual Rev. 2
Page 15

RETURNS

RETURNS
In case you need to get support or return a product:
If you are located in the U.S., contact Chauvet World Headquarters.
If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
If you are located in Benelux, contact Chauvet Europe BVBA.
If you are located in France, contact Chauvet France.
If you are located in Germany, contact Chauvet Germany.
If you are located in Mexico, contact Chauvet Mexico.
If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local distributor. See www.chauvetdj.com Germany, or Mexico.
If you are located outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico, contact your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetdj.com
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return.
To submit a service request online, go to www.chauvetdj.com/service-request Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet
will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.
for distributors outside the U.S., UK, Ireland, Benelux, France,
for contact details.
.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Before sending the product, clearly write the following information on a piece of paper and place it inside the box:
Your name
Your address
Your phone number
•RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned product(s).
EVE E-100Z V3 User Manual Rev. 2
Page 13 of 14
Page 16

CONTACT US

General Information Technical Support
World Headquarters
UK
Benelux
France
Germany
Mexico
Address: Av. de las Partidas 34 - 3B
Lerma, Edo. de México, CP 52000
CONTACT US
Address: 5200 NW 108th Ave. Voice: (844) 393-7575
Sunrise, FL 33351 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetdj.com
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetdj.eu
NG16 6NT
Voice: + 44 (0) 17 73 511115
Fax : +44 (0) 1773 511110
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetdj.eu
Voice: +32 9 388 93 97
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetdj.eu
Voice: +33 1 78 85 33 59
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany Website: www.chauvetdj.eu
Voice: +49 421 62 60 20
(Entrance by Calle 2)
Zona Industrial Lerma Website: www.chauvetdj.mx
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record. Fol­low the instructions to request support or to return a product. Visit our website for contact details.
Page 14 of 14
EVE E-100Z V3 User Manual Rev. 2
Loading...