![](/html/a5/a522/a522ff447e4c3a5dbb5b184c08d0330a09f8b98225a725525ab205ab18403062/bg1.png)
CATEYE ADVENTURE
CYCLOCOMPUTER CC-AT200W
0678
ENG
SENSOR
ZONE
5
4
5 mm
5 mm
U.S. Pat. Nos. 5236759/6957926 Pat./Design Pat. Pending Copyright© 2009 CATEYE Co., Ltd.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are
not expressly approved by CatEye Co., Ltd. May void the user ’s authority to operate the equipment.
WARNING / CAUTION
Do not concentrate on the computer while riding. Ride safely!•
Install the magnet, sensor, and bracket securely. Check these periodically.•
If a child swallows a battery, consult a doctor immediately.•
Do not leave the computer in direct sunlight for a long period of time.•
Do not disassemble the computer.•
Do not drop the computer to avoid malfunction or damage.•
When using the computer installed on the bracket, change the • MODE by pressing on the four
dots below the screen, or by pressing on the SSE simultaneously, to start or stop the timer.
Pressing hard on other areas may result in malfunction or damage to the computer.
Be sure to tighten the dial of the FlexTight bracket by hand. Tightening it strongly using a •
tool, etc. may damage the screw thread.
Before using the computer, please thoroughly read this manual and keep
it for future reference.
Preparing the computer
Opera tion of butt ons when the com puter is
Battery case cover
Pressure sensor
km/h mph
: Speed unit
: Wheel size icon
: Sensor signal reception icon
When using the computer for the first time or resetting to the factory
default setting, format according to the following procedure.
Format (initialize)
1
1. Press and hold the MENU button.
2. Press the AC button.
3. Release the AC button.
4. Release the MENU button.
Select the speed and temperature unit
2
When MODE and SSE are pressed simultaneously, “Speed unit” or “Temperature unit” can be
selected. Select “km/h” or “mph” for the speed
unit, and “°C” or “°F” for the temperature unit.
Press MENU to register.
Switch the screen (By
pressing simultaneously)
Enter the tire circumference
3
Enter the tire circumference of your bicycle in mm.
Refer to the tire circumference reference table.*
In crea se
the value
Set the sensor ID
4
Hold the computer body close to the sensor (20
- 70cm), and press and hold the RESET button on the sensor with a sharp object. Sensor
will ran domly generate an ID number for the
computer body to receive, and displays on the
screen. If successfully synchronized, screen will
automatically move on to Clock setting screen.
When setting the sensor ID, place the sensor at least 20 cm (approxi-*
mately 8 inches) away from the computer. Press and hold the RESET
button, the sensor will send the ID when releasing the button.
The computer is on standby for 5 minutes while setting the sensor ID. It dis-*
plays “ERROR”, and cancels the ID when no ID signal is received during the
standby, or you press MODE and SSE simultaneously. Screen will move on to
clock setting. Without the ID, speed cannot be detected and displayed. Be sure
to set the sensor ID according to “Sensor ID setting” on the menu screen.
Original ID is saved if you cancel the ID.*
Start the ID setting (By pressing & holding)
Set the clock
5
When MODE and SSE are pressed simultaneously, “Displayed time”, “Hour”, and “Minute”
will appear, in this order.
Switch the screen
or move digits
(By pressing
simultaneously)
Measure wheel circumference (L) of your bike
To get the most accurate calibration do a wheel roll out. With the valve stem
perpendicular to the ground, mark the pavement at the valve stem. With the
riders weight on the bike, roll the wheel one tire revolution in a straight line
and mark the ground when the valve stem is perpendicular to the ground
again. Measure the distance in millimeters. This is the most accurate wheel
calibration number.
Unit
selection
Move digits (By pressing simultaneously)
24h ↔ 12h,
or increase
the value
mounted on the bracket
Press only the computer
body.
Cancel the ID or
reset (By pressing
simultaneously)
AC
Register
the setting
Register
the setting
Register
the setting
(Finish)
MENU
Move to Clock
Setting when no
ID has been set
Press the SSE butt on wit h
the computer body together.
SSE bu tton by i tself does
not function.
CCAT2W-090526
Click
Tire circumference
reference table
ETRTO Tire size
47-203 12x1.75 935
54-203 12x1.95 940
40-254 14x1.50 1020
47-254 14x1.75 1055
40-305 16x1.50 1185
47-305 16x1.75 1195
54-305 16x2.00 1245
28-349 16x1-1/8 1290
37-349 16x1-3/8 1300
32-369
40-355 18x1.50 1340
47-355 18x1.75 1350
32-406 20x1.25 1450
35-406 20x1.35 1460
40-406 20x1.50 1490
47-406 20x1.75 1515
50-406 20x1.95 1565
28-451 20x1-1/8 1545
37-451 20x1-3/8 1615
37-501 22x1-3/8 1770
40-501 22x1-1/2 1785
47-507 24x1.75 1890
50-507 24x2.00 1925
54-507 24x2.125 1965
25-520 24x1(520)1753
28-540 24x1-1/8 1795
32-540 24x1-1/4 1905
25-559 26x1(559)1913
32-559 26x1.25 1950
37-559 26x1.40 2005
40-559 26x1.50 2010
47-559 26x1.75 2023
50-559 26x1.95 2050
54-559 26x2.10 2068
57-559 26x2.125 2070
58-559 26x2.35 2083
75-559 26x3.00 2170
28-590 26x1-1/8 1970
37-590 26x1-3/8 2068
37-584 26x1-1/2 2100
20-571 650x20C 1938
23-571 650x23C 1944
25-571
40-590 650x38A 2125
40-584 650x38B 2105
25-630 27x1(630)2145
28-630 27x1-1/8 2155
32-630 27x1-1/4 2161
37-630 27x1-3/8 2169
18-622 700x18C 2070
19-622 700x19C 2080
20-622 700x20C 2086
23-622 700x23C 2096
25-622 700x25C 2105
28-622 700x28C 2136
30-622 700x30C 2146
32-622 700x32C 2155
35-622 700x35C 2168
38-622 700x38C 2180
40-622 700x40C 2200
42-622 700x42C 2224
44-622 700x44C 2235
45-622 700x45C 2242
47-622 700x47C 2268
54-622 29x2.1 2288
60-622 29x2.3 2326
17x1-1/4
(
)
369
24x3/4
Tubuler
650C Tubuler
26x7/8
650x25C
26x1(571
700C
Tubuler
L (mm
1340
1785
1920
1952
)
2130
3
When cleaning the computer, bracket and sensor, do not use thinners, benzene, or alcohol. •
A temperature sensor is built in the computer. If the sensor is heated by direct sunlight or •
body heat, it may not indicate the temperature correctly.
The altitude data with this unit is for reference only; accordingly, do not use this unit as a •
measuring device for professional use.
Dispose of used batteries according to local regulations.•
LCD screen may be distorted when viewed through polarized sunglass lenses.•
Wireless Sensor
In order to prevent any interference with the sensor signal, the transmission range is designed
to be 20 to 70 cm, in addition to use of the ID code. (This receiving range is only a reference.)
Please note the following points.
To use this unit, the sensor ID has to be set.•
Two different IDs, • ID1 and ID2, can be registered to this unit, which are identified automatically.
The computer cannot receive when the distance between the sensor and computer is too long. •
Temperature drop and battery drain may worsen the receiving sensitivity even if they are within
the transmission range.
Interference may occur, resulting in incorrect data, if the computer is:
Near a TV, PC, radio, motor, or in a car or train.•
Close to a railroad crossing, railway tracks, TV stations and/or radar base.•
Using with other wireless devices, or some particular battery lights.•
How to restart
After changing the battery, or when the computer displays an error, restart the computer according to the following procedure.
Press the 1. AC button on the back of the computer.
Set the clock. Refer to “Preparing the computer 5”.2.
The stored sea level altitude, home altitude, speed unit, wheel size, sensor ID, countdown dis-*
tance, selected wheel, AT setting, total distance and total altitude gain will not be changed after
pressing the AC button.
How to install the unit on your bicycle
Bracket band
1
Bracket
2
Nut
3
Sensor
4
Magnet
5
Sensor rubber pad
6
Bracket rubber pad
)
7
Nylon ties (x2)
8
Install the sensor and magnet
The di stanc e from
A
the computer to the
sensor is w it hi n the
transmission range.
Max
70 cm
1
Install the sensor
Install the sensor to the front fork as high as possible.*
3
Attach the bracket to the stem or handlebar
The magnet passes
B C
through the sensor zone.
Right front fork (inside)
The magnet may b e installed anywhe re on the spoke if the *
above installation conditions are satisfied.
Right front fork
Pull securely
When attaching the bracket to the stem
Sensor zone
Stem
The clearance between
the sensor and magnet is 5 mm or less.
2
Install the magnet
Spoke on the right
To the sensor zone
Caution:
Round off the cut edge
of the bracket band to
prevent injury.
When attaching the bracket to the handlebar
On account of the receiving sensitivity, attach the *
bracket so that the computer is kept horizontal.
4
Remove/install the computer
After installation, check that the speed is displayed on the computer when gently turning the *
front wheel. When it is not displayed, check the positions of A , B , and C .
While supporting it by hand,
Click
push it out as if lifting the front up
Handlebar
For wing type handlebar or oversized stem, *
bracket can be mounted using the Bracket
Holder and nylon ties. (Option)
Cut
1
![](/html/a5/a522/a522ff447e4c3a5dbb5b184c08d0330a09f8b98225a725525ab205ab18403062/bg2.png)
Operating the computer [Measuring screen]
Starting/Stopping measurement
You can select the Auto mode (automatic measuring) or manual mode. During measurement,
km/h or mph flashes. The maximum speed and
total distance are updated regardless of starting/stopping measurement.
Auto mode (•
Measurements start automatically when the
bicycle is in motion.
Manual mode•
Wh en the comp uter is mou nte d on the
bracket, start/stop measuring by pressing
the MODE and SSE buttons simultaneously.
For switching between Auto and Manual mode, refer *
to “Auto mode setting” on the menu screen.
Switching computer function
on)
: Pace arrow
Indic ates wh ether t he curr ent spe ed is
faster (
speed.
: Auto mode icon
: Low battery indicator of the computer
Pressing the MODE changes the middle/bottom row display.
Current speed
0.0(4.0) – 105.9 km/h
[0.0(3.0) – 65.0 mph]
Selected mode at
the middle display
Selected mode at
the bottom
) or slower ( ) than the average
Measuring screen
Middle display
Temperature
-20 – 60 ˚C
[-4 – 140 ˚F]
Sea Level Altitude
-500 – 9000 m
[-1640 – 29600 ft]
Slope (%)
-99% – +99%
*1
Ascending
0 – 999999 m [ft]
0 – 99999
/ 100 – 99999 x 1000 m [ft]
With the computer installed on the bracket, press on the four raised dots on the face of the computer.*1
If *2 Tm exceeds approximately 27 hours or Dst exceeds 9999.99 km, .E (Error) is displayed as the
average speed. Reset data.
Altitude
Total Altitude
Gain
0:00 – 23:59 or 1:00 – 12:59
0:00’00” – 99:59’59”
0.00 – 9999.99 km [mile]
0.00 – 9999.99 km [mile]
0.0 – 105.9 km/h [0.0 – 65.0 mph]
0.0(4.0) – 105.9 km/h [0.0(3.0) – 65.0 mph]
9999.90 – 0.00 km [mile]
Shortcut to countdown distance setting. Valid while
the computer is receiving no signal from sensor.
0.0 – 9999.9 / 10000 – 999999 km [mile]
Resetting data
While displaying any data other than Dst-2, pressing and holding the MODE and SSE
simultaneously resets the measurement data to 0. While displaying Dst-2, pressing and
holding the MODE and SSE simultaneously resets only Dst-2 to 0. In both cases, the
total distance and total altitude gain are not reset.
Power-saving mode
If the computer has not received a signal for 10 minutes, power-saving mode will activate and
only the clock will be displayed. When the computer receives a sensor signal again, the measuring screen reappears. If 60 minutes’ inactivity elapses, power-saving mode will change to
SLEEP mode. Pressing the MODE in SLEEP mode brings up the measuring screen.
Altitude measurement
This unit detects the change in atmospheric pressure and temperature using a pressure sensor
built in the computer, and converts it to the altitude using the relation between the altitude and
pressure of ISO 2533 (Standard atmosphere), which was developed based on the international
standard atmosphere specified by the International Civil Aviation Organization (ICAO). Accordingly, the measurements tend to change, even at the same point, according to the atmospheric
pressure due to the weather condition. Furthermore, the measurements may change more
than 30 m from the early morning to the evening even under a stabilized weather condition.
The measurements may be incorrect in the following place or environment.
When the atmospheric pressure and temperature change significantly due to a rapid •
weather change.
In the place where the atmospheric pressure is regulated, such as inside an airplane.•
The altitude data may change temporarily when the temperature changes rapidly by get-•
ting out of a room, etc. It may return to a correct value after a while.
Altitude measurement
This unit has four altitude-related functions and temperature function.
Sea level altitude
Slope ......................
Ascending altitude
Total altitude gain
.... The current sea level altitude is displayed.
For effective use of the sea level altitude, refer to “Sea level altitude correction”.*
Measures slope in percent unit, where 45 degree angle being 100%.
It is updated every 3 seconds, calculating from several times of the change in *
altitude and the trip distance. Slope update may be delayed. Abnormal data may
also be temporarily displayed when speed quickly changes or during low-speed.
...
Accumulation of ascent from the reset point to the current point is displayed.
...The total altitude gain is displayed.
Bottom display
Clock
Tm
Elapsed Time
Dst
Trip Distance
Dst 2
Trip Distance-2
Av
Average Speed
Mx
Maximum Speed
Countdown
Distance
Odo
Total Distance
Shortcut A
(By pressing
& holding)
Shortcut to sea level
alt itude cor recti on.
Valid while the computer is receiving no
signal from sensor.
*2
Shortcut B
(By pressing
& holding)
Temperature ...........The current temperature is displayed.
The altitude measurement is updated every 3 seconds during measurement (when counting the *
elapsed time), but not updated when measurement stops.
Caution:
When Auto mode is Off, elapsed time counts even if the bicycle is not in motion.
After measurement, be sure to press MODE and SSE simultaneously to stop measuring.
It is updated when the measurement screen is displayed (while measuring: *
every 3 seconds, while not riding: every 20 seconds).
Sea level altitude correction
This unit determines the altitude by converting the change in atmospheric pressure and temperature; therefore, it may cause deviation from the actual sea level altitude. It is recommended
to correct the sea level altitude just before measurement, using either the following methods.
• ADJUST (sea level altitude correction): Enter the altitude at the current point.
Enter the actual value at the point where the sea level altitude is known,
such as along the seashore, or at a sign on the mountain, etc.
Press and hold * MODE and SSE simultaneously on the setting screen to reset the corrected value to the default (a value according to ISO2533).
• HOME (home altitude setting): Preset a specific sea level altitude.
Preset the sea level altitude at your home in advance. Move to the HOME screen,
and then return to the measuring screen by pressing MENU or the relevant shortcut. Then, the sea level altitude changes to the preset value. You can start with the
correct sea level altitude by setting home altitude before stating from your home.
The sea level altitude is corrected on the menu screen “Sea level altitude correction”. Move to the sea *
level altitude correction screen by pressing MENU or the relevant shortcut from the measuring screen.
Countdown distance
Once the target trip distance is set, the unit displays the countdown distance to the target,
and notifies at arrival. When the unit reaches the target distance, the countdown distance
appears and the value flashes. The screen returns to the original display in 5 seconds.
The target distance is set on the menu screen “Countdown distance setting”. Move to the countdown *
distance setting screen by pressing MENU, MODE, or the relevant shortcut from the measuring screen.
Changing the computer settings [Menu screen]
Pressing MENU on the measuring screen moves to the menu screen for setup change. Once inside the menu screen, press the MODE button to scroll through setup items. Press MODE+SSE to
enter the edit screens. Change cannot be done if there is an incoming signal and timer is active.
: When using a shortcut, the sea level altitude correction screen or the countdown distance setting
Shortcut
screen is not displayed as shown in the figure below. It moves directly to the edit screen.
Sea level altitude correction
Countdown distance setting
Wheel selection
Wheel size entry
Sensor ID setting
Auto mode setting
Clock setting
Menu
screen
Speed/temperature unit selection
Set ting chan ge
(by pressing
simultaneously)
After changing, be sure to press * MENU to register the setting.
If the setting screen is not touched for a minute, the measur-*
ing screen appears without data changes.
Sea level altitude correction
Shortcut A
: MODE (By pressing & holding) → Back to the previous measuring screen
...................................Select ADJUST (sea level altitude correction) or HOME (home altitude
setting) by pressing MODE. When MODE and SSE are pressed simultaneously,“+/- selection” or “Move digit” can be selected, and pressing
MODE increases the +/- selection or the value. Enter the desired altitude.
For details, refer to “Sea level altitude correction”.*
Countdown distance setting
Shortcut B
: MODE (By pressing & holding) → Back to the previous measuring screen
................................Pressing MODE increases the value and pressing MODE and SSE
Wheel selection .....Toggle between the specified wheel size (tire circumference)
Wheel size entry ....
Auto mode setting
simultaneously moves to the next digit.
and
. Use this function if the computer is to be shared between
two bicycles. Pressing MODE toggles between
Pressing MODE increases the value and pressing MODE and SSE
simultaneously moves to the next digit. To enter the wheel size
display
using “Wheel selection”.
...Press MODE to select ON or OFF.
Clock setting ...........Operate as described in “Preparing the computer 5”.
Total distance manual entry
................................Before re-initializing the computer, note the total distance. This
Sensor ID setting ....Pressing MODE changes to ID1 or ID2, and pressing MODE and
Speed/temperature unit selection
................................Operate as described in “Preparing the computer 2”.
reading will later allow you to enter the total distance manually.
Pressing MODE increases the value and pressing MODE and SSE
simultaneously moves to the next digit.
SSE simultaneously moves to ID setting. Set the ID as described
in “Preparing the computer 4”.
ID2* is used when the computer is shared with the second sensor installed
to another bicycle. The computer will identify ID1 and ID2 automatically
after waking up from Power-saving mode.
Total distance manual entry
and .
,
2