Carrier ASPBS1CCA016, ASPBA1CCA016 User Manual

Home Standby - 16kW
Air-Cooled Gas Engine Generator Sets
Continuous Standby Power Rating — 16kW 60Hz
Models: ASPBS1CCA016 (Steel)
ASPBA1CCA016 (Aluminum)
INCLUDES:
Automatic
• Electronic Governor
• Pre-wired External Connection Box
• Flexible Fuel Line
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• UL 2200 Listed to U.S. and Canadian Standards
Ultra Quiet Mode
Low Speed Exercise
59 dB(A) at 23 feet
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of CARRIER’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose CARRIER with the confidence that these systems will provide superior performance.
TEST CRITERIA:
>
PROTOTYPE TESTED
>
SYSTEM TORSIONAL TESTED
>
NEMA MG1-22 EVALUATION
>
MOTOR STARTING ABILITY
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on all models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.
SINGLE SOURCE SERVICE RESPONSE from Carrier’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a CARRIER SYSTEM.
CARRIER TRANSFER SWITCHES. Long life and reliability are synonymous with CARRIER. One reason for this confidence is that the CARRIER product line includes its own transfer systems and controls for total system compatibility.
FEATURES
HOME STANDBY SPECIFICATIONS
Home Standby - 16kW
ENGINE
•Durable OHVI Design
•”Spiny-lok” cast iron cylinder walls
•Electronic ignition, spark advance and compression release
•Full pressure lubrication system
•Low oil pressure shutdown system
•High temperature shutdown
•Revolving field
•Skewed stator
•Displaced phase excitation
•Automatic voltage regulation
•UL 2200 Listed
•Fully Automatic
•Remote Mounting
•UL Listed
•Manual/Auto/Off switch
•Utility voltage sensing
•Utility interrupt delay
•Engine warm-up
•Engine cool-down
•Seven day exerciser
•Timed Trickle Battery charger
•Main Line Circuit Breaker
•Weather protective enclosure
•Enclosed critical grade muffler
•Small, compact, attractive
•Pre-wired External Connection Box
•1’ Flexible Fuel Line
•Composite Mounting Pad
•Pre-wired conduits
•UL Listed wire nuts
Maximizes engine “breathing” for increased fuel efficiency. Cylinder walls run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines.
Rigid construction and added durability provide long engine life.
These features combine to assure smooth, quick starting every time.
Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life.
Superior shutdown protection prevents catastrophic engine damage due to low oil.
Prevents damage due to overheating.
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Produces a smooth output waveform for compatibility with electronic equipment.
Maximizes motor starting capability. Provides more surge capability than brushless generator designs.
Regulates the output voltage to ±2% prevents damaging voltage spikes.
For your safety
Transfers your vital electrical loads to the energized source of power.
Mounts near your existing distribution panel for simple, low cost installation.
For your safety
Selects the operating mode.
Constantly monitors utility voltage, setpoints 60% dropout, 70% pick-up, of standard voltage.
Prevents nuisance start-ups of the engine, set point approximately 10 seconds.
Ensures engine is ready to assume the load, setpoint approximately 10 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages.
Maintains battery amperage to insure starting.
Protects generator from overload.
Ensures protection against mother nature. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Aluminum enclosure available - (Model 05244)
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Makes for an easy, eye appealing installation.
Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide.
GENERATOR
TRANSFER
SWITCH
INSTALLATION
SYSTEM
MICROPROCESSOR CONTROL
UNIT
Loading...