The Carrier Transicold model 69NT40--561--001 to 199
series units are of lightweight aluminum frame
construction, designed to fit in the front of a container
and serve as the container’s front wall.
They are one piece, self--contained, all electric units,
which include cooling and heating systems to provide
precise temperature control.
The units are supplied with a complete charge of
refrigerant R--134a and compressor lubricating oil, and
are ready for operation upon installation. Forklift
pockets are provided for unit installation and removal.
The base unit operates on nominal 380/460 volt,
3--phase, 50/60 hertz (Hz) power. An optional
autotransformer may be fitted to allow operation on
nominal 190/230, 3--phase, 50/60 Hz power. Power for
the control system is provided by a transformer which
steps the supply power down to 18 and 24 volts, single
phase.
The controller is a Carrier Transicold Micro--Link 3
microprocessor.Thecontrollerwilloperate
automatically to select cooling, holding or heating as
required to maintain the desired set point temperature
within very close limits. The unit may also be equipped
with an electronic temperature recorder.
The controller has a keypad and display for viewing or
changing operating parameters. The display is also
equipped with lights to indicate various modes of
operation.
2CONFIGURATION IDENTIFICATION
Unit identification information is provided on a plate
located to the left of the receiver or water--cooled
condenser, on the back wall of the condenser section.
The plate provides the unit model number, the unit serial
number and the unit parts identification number (PID).
Themodelnumberidentifiestheoverallunit
configuration,whilethePIDnumberprovides
information on specific optional equipment, factory
provisioned to allow for field installation of optional
equipment and differences in detailed parts.
3FEATURE DESCRIPTIONS
3.1Control Box
Units are equipped with either an aluminum or
composite material box, and may be fitted with a
lockable door.
3.2Temperature Readout
The unit is fitted with suction and discharge temperature
sensors. The sensor readings may be viewed on the
controller display.
3.3Pressure Readout
The unit is fitted with evaporator and discharge
transducers. The transducer readings may be viewed
on the controller display.
3.4Compressor
The unit is fitted with a scroll compressor equipped with
suction and discharge service connections.
3.5Condenser Coil
The unit is fitted with a four--row condenser coil using
7mm tubing.
3.6Evaporator
Evaporator section is equipped with an electronic
expansion valve (EEV).
3.7Evaporator Fan Operation
Units are equipped with three-- phase evaporator fan
motors. Opening of an evaporator fan internal protector
will shut down the unit.
3.8Plate Set
Each unit is equipped with a tethered set of wiring
schematics and wiring diagram plates. The plate sets
are ordered using a seven--digit base part number and a
two--digit dash number.
4OPTION DESCRIPTIONS
Various options may be factory or field equipped to the
base unit. These options are listed in the tables and
described in the following subparagraphs.
4.1Battery
The refrigeration controller may be fitted with standard
replaceable batteries or a rechargeable battery pack.
Rechargeable battery packs may be fitted in the
standard or in a secure location.
4.2Dehumidification
The unit may be fitted with a humidity sensor. This
sensor allows setting of a humidity set point in the
controller. In dehumidification mode, the controller will
operate to reduce internal container moisture level.
4.3USDA
The unit may be supplied with fittings for additional
temperature probes, which allow recording of USDA
Cold Treatment data by the integral DataCORDER
function of the Micro--Link refrigeration controller.
4.4Interrogator
Units that use the DataCORDER function are fitted with
interrogator receptacles for connection of equipment to
download the recorded data. Two receptacles may be
fitted; one is accessible from the front of the container
and the other is mounted inside the container (with the
USDA receptacles).
4.5Remote Monitoring
The unit may be fitted with a remote monitoring
receptacle. This item allows connection of remote
indicators for COOL, DEFROST and IN RANGE.
Unless otherwise indicated, the receptacle is mounted
at the control box location.
4.6Communications Interface Module
The unit may be fitted with a communications interface
module. The communications interface module is a
slave module, which allows communication with a
master central monitoring station. The module will
respond to communication and return information over
iii
T-340PL
the main power line. Refer to the ship master system
technical manual for additional information.
4.7Autotransformer
An autotransformer may be provided to allow operation
on190/230,3--phase,50/60Hzpower .The
autotransformer raises the supply voltage to the
nominal 380/460 volt power required by the base unit.
The autotransformer may also be fitted with an
individual circuit breaker for the 230 volt power.
If the unit is equipped with an autotransformer and
communications module, the autotransformer will be
fitted with a transformer bridge unit (TBU) to assist in
communications.
4.8Temperature Recorder
The units may be fitted with an electronic temperature
recording device.
4.9Handles
The unit may be equipped with handles to facilitate
access to stacked containers. These fixed handles are
located on either side of the unit.
4.10Thermometer Port
The unit may be fitted with ports in the front of the frame
for insertion of a thermometer to measure supply and/or
return air temperature. If fitted, the port(s) will require a
cap and chain.
4.11Water Cooling
The refrigeration system may be fitted with a
water--cooled condenser. The condenser is constructed
using copper--nickel tube for sea water applications.
The water--cooled condenser is in series with the air
cooled condenser and replaces the standard unit
receiver.When operating on the water--cooled
condenser, the condenser fan is deactivated by a water
pressure switch or condenser fan switch.
4.12Back Panels
Aluminum back panels may have access doors and/or
hinge mounting.
4.13460 Volt Cable
Various power cable and plug designs are available for
the main 460 volt supply. The plug options tailor the
cables to each customer’s requirements.
4.14230 Volt Cable
Units equipped with an autotransformer require an
additional power cable for connection to the 230 volt
source. Various power cable and plug designs are
available. The plug options tailor the cables to each
customer’s requirements.
4.15Cable Restraint
Various designs are available for storage of the power
cables. These options are variations of the compressor
section cable guard.
4.16Upper Air (Fresh Air Make Up)
The unit may be fitted with an upper fresh air makeup
assembly. The fresh air makeup assembly is available
with a vent positioning sensor (VPS) and may also be
fitted with screens.
4.17Lower Air (Fresh Air Make Up)
The unit may be fitted with a lower fresh air makeup
assembly. The fresh air makeup assembly is available
with a vent positioning sensor (VPS) and may also be
fitted with screens.
4.18Labels
Safety Instruction and Function Code listing labels
differ, depending on the options installed. Labels
available with additional languages are listed in the parts
list.
4.19Controller
Two replacement controllers are available:
1. Remanufactured -- Controller is the equivalent of a
new OEM controller and is supplied with a 12--month
warranty.
2. Repaired -- Controller has had previous faults
repaired and upgraded with the latest software.
Note: Repaired controllers are NOT to be used for
warranty repairs; only full OEM Remanufactured
controllers are to be used.
Controllers will be factory--equipped with the latest
version of operational software, but will NOT be
configured for a specific model number and will need to
be configured at the time of installation or sale.
4.20Condenser Grille
Two styles of condenser grilles are available: direct
bolted grilles and hinged grilles.
4.21Emergency Bypass
The optional Emergency Bypass switch (EB) functions
to bypass the controller in the event of controller failure.
4.22eAutoFresh
The optional eAutoFresh venting system moderates the
atmospheric level inside the container unit in response
to cargo respiration.
4.23Controlled Atmosphere
Units may be fitted with the TransFresh option.
For information on the TransFresh system, contact
TransFresh Corporation, P.O. Box 1788, Salinas, CA
93902.
T-340PL
iv
OPTION LEGEND
General
-
XFeatures Installed
PFactory Installation of Equipment to
Autotransformer Codes
1Transformer Fitted
2Transformer With CB2 Fitted
Back Panel Codes
1Bolted Panels
4Hinged Panels
5Bolted Panels with 5+1 Heater Arrangement
Battery and Controller Kit (Facing View) Codes
RRechargeable Cells
SSecure Location (Rechargeable Cells)
Bulkhead Penetration Codes
1Not Installed
2Standard Installed
Cable and Compressor Guards
1Standard Guard, 460 V Cable
2Standard Guard, Transicord
Cable Restraint Codes
2Left Bungy Cord Only
3J-Hook
RDummy Receptacle
Compressor Codes
SScroll
SSScroll with Semi-Hermetic Piping
Condenser Fan Grille Codes
BBolted Grille
HHinged Grille
Condenser Fan Motor Codes
1Single--Phase Condenser Fan Motor
2Three--Phase Condenser Fan Motor
Control Box Communications Interface Module
Codes
2HighDataRate
4Low Data Rate
Control Box Preparation Codes
1Aluminum Box with Latch Fastener
2Aluminum Box with Screw Fastener
3Aluminum Box with Locking Screw Fastener
Feature Not Applicable
Allow Field Installation (Provision)
Control Box Shield Codes
1High Voltage Shield
2Low Voltage Shield
Control Box Door Codes
2Standard Door, Slotted Screw Fasteners
3Standard Door, Wing Screw Fasteners
4Door with Flat Window, Wing Fasteners
5Latching Door
6Standard Door, Phillips Screw Fasteners
Controlled Atmosphere -- TransFresh Codes
1Kit for Units Not Provisioned for TransFresh
Rain Gutter Codes
1Standard Length Bolted Gutters
4Riveted Gutters
Heater and Sensor Codes
1Standard Heater Arrangement
25+1 Heater Arrangement
XDehumidification Option
Interrogator Codes
1Left Straight Mount (Option V)
3Control Box Mount
4Left Straight Mount (Option D)
Label Codes
1English
Low Voltage Harness Codes
DUsed in conjunction with USDA codes
VUsed in conjunction with USDA codes
Lower Fresh Air Codes
1Lower Fresh Air Not Installed
2Lower Fresh Air Installed
4Lower Fresh Air With Screens, VPS Installed
Remote Monitoring (RM) Receptacle and Switch
Panel
1No RM, Start Switch Plate
2No RM, Start Switch Plate with Boot
3No RM, Compressor Fan Switch Plate
4No RM, Manual Defrost (MD) Switch Plate
5No RM, MD Switch Plate with Boot
6No RM, Amber Defrost Light Switch Plate
7No RM, Red Defrost Light Switch Plate
8With Internal RM Switch Plate
9With Internal RM, MD Switch Plate
10With Internal RM, Amber Defrost Light Switch
Plate
11With External RM Switch Plate
v
T-340PL
Temperature Recorder Codes
9No Temperature Recorder
PSTemperature Recorder Provision -- Recorder
Box Cover Only, Customer Specific
12Special Electronic Partlow
13Standard Electronic Partlow
Thermometer Port Codes
1Supply Air Port
2Return Air Port
BBoth Ports
Upper Fresh Air Codes
1Not Installed -- Access Panel Only
2Upper Fresh Air Installed with Standard
Fasteners
2Upper Fresh Air Installed with Stainless Steel
Fasteners
3Upper Fresh Air Installed with Screens
4Upper Fresh Air Installed with VPS
Upper Fresh Air -- eAutoFresh Codes
1eAutoFresh Installed
USDA Codes
1Option 1 Probe Kit
2Option 2 Probe Kit
DOption D
POption P
SField--Installed Kits for USDA Provisioned Units
and 5+1 Heater Arrangement
VOption V
Vacuum Relief Valve Codes Codes
1Vacuum Relief V alve
2Valve with Nitrogen--Fed Atmosphere
3Valve, Customer Specific
230 and 460 Volt Cable Codes
1Option1
2Option 2
3Option 3
4Option 4
5Option 5
6Option 6
7Option 7
8Option 8
9Option 9
5ORDERING INSTRUCTIONS
All orders and inquiries for parts must include: Parts Identification Number (PID), Model Number, Unit Serial Number,
Part Number, description of part as shown on list, and quantity required. Address all correspondence for parts to the
following address:
CARRIER TRANSICOLD DIVISION
Replacement Components Group, TR-20
P.O. Box 4805, Syracuse, New York 13221
6LETTER DESIGNATIONS
The following letter designations are used to classify parts throughout this list:
A/R=As Required
N/A=Not Available
NS=Not Shown in illustration
NSS=Not Sold Separately - order next higher assembly or kit
PID=Parts Identification Number - essential to identify unit configuration.
PL=Purchase Locally
SST=Stainless Steel - 300 Series unless otherwise specified.
SV=Suffix SV - added to part number designates service replacement part.
or FAX to: (315) 432-3778
T-340PL
vi
1REFRIGERATION UNIT ASSEMBLY
1.1 REFRIGERATION UNIT -- AREA LOCATOR
1
42
41
40
37
38
39
21
36
35
34
33
32
30
31
29
2
3
27
28
6
26
25
1
4
5
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
44
43
45
46
2T-340PL
1.1REFRIGERATION UNIT -- AREA LOCATOR (Continued)
ItemSection NumberArea Description
1Refer to Section 1.2Upper Fresh Air
2Refer to Section 1.3Upper Fresh Air -- eAutoFresh
3Refer to Section 1.4Upper Fresh Air -- eAutoFresh Panel Assembly
4Refer to Section 1.5Controlled Atmosphere -- TransFresh
5Refer to Section 1.6Bulkhead Penetration -- Upper Air Exchange
6Refer to Section 1.7Thermometer Port
7Refer to Section 1.8Rain Gutters
8Refer to Section 1.9USDA
9Refer to Section 1.10Control Box -- Door
10Refer to Section 1.11Control Box -- Shield
11Refer to Section 1.12Control Box -- Wiring
12Refer to Section 1.13Control Box -- RMU Receptacle and Switch Panel -- No RM and Internal Views
13Refer to Section 1.14Control Box -- RMU Receptacle and Switch Panel -- External View
14Refer to Section 1.15Control Box -- Remote Monitoring Unit (RMU)
15Refer to Section 1.16Control Box -- Controller Module Section and Software Cards
16Refer to Section 1.17Control Box Preparation
17Refer to Section 1.18Controller Kit -- Facing View
18Refer to Section 1.19Controller Kit -- Detailed View With and Without Shields
19Refer to Section 1.20Controller Kit -- Rear View
20Refer to Section 1.21Controller Kit -- Emergency Bypass System)
21Refer to Section 1.22Interrogator Receptacle
22Refer to Section 1.23Handles
23Refer to Section 1.24Compressor, Mounting Components, and Power Cable
24Refer to Section 1.25Compressor Tubing
25Refer to Section 1.26Economizer
26Refer to Section 1.27Liquid Line Components
27Refer to Section 1.28Receiver
28Refer to Section 1.29Water--Cooled Condenser
29Refer to Section 1.30Air--Cooled Condenser Coil and Covers
30Refer to Section 1.31Condenser Fan Motor
31Refer to Section 1.32Condenser Fan Grille Assembly
32Refer to Section 1.33Voltage Cables
33Refer to Section 1.34Cable Guards
34Refer to Section 1.35Autotransformer
35Refer to Section 1.36Cable Restraint Components
36Refer to Section 1.37Vacuum Relief Valve / Controlled Atmosphere
37Refer to Section 1.38Electronic Temperature Recorder -- Options 9 and P
38Refer to Section 1.39Electronic Temperature Recorder -- Options 12 and 13
39Refer to Section 1.40Drain
40Refer to Section 1.41Lower Fresh Air Make--up
41Refer to Section 1.42Bulkhead Penetration -- Lower Air Exchange
42Refer to Section 1.43Labels and Decals
43Refer to Section 1.44Evaporator Fan Assembly
44Refer to Section 1.45Evaporator Tubing and Coil
45Refer to Section 1.46Heaters and Sensors (Rear Panels Removed)
46Refer to Section 1.47Back Panel Assembly
NSRefer to Section 1.48Harness -- Low Voltage
NSRefer to Section 1.49Harness -- High Voltage
NSRefer to Section 2.1DataLine/Data Reader
3T-340PL
1.2UPPER FRESH AIR
4
3
2
8
9
10
1
6
SIDE VIEW
5
7
8
9
FRONT VIEW
OPTION 1
OPTIONAL POSITION FOR TIR EQUIPPED UNITS
4T-340PL
1.2UPPER FRESH AIR (Continued)
ItemPart NumberDescriptionQty
OPTION 1 -- ACCESS PANEL ONLY
79--01697--06SVPanel Assembly, Access, Evaporator, White -- Includes:A/R
968--12933--00Disc, 12.35 Inch Diameter1
1034--06185--01Screw , Machined, #8--32 X 0.50 with Nylock1
1166U1--5362--2Nut, Wing, 5/16--18, SST1
1266U1--5321--13Washer, Plain 5/16 W Type A, SST1
1334--06053--19Washer, Mylar 1.00 OD X 0.312 ID1
1434--06053--13Washer, Mylar, 1/4 ID X 0.80 OD8
1534--06212--12Washer, Flat, 1/4, SST8
1666CH1--1 172--2Trim, Flexible 2.00 Inches Long1
1758--00969--00Wire Tie 2.80 Inch Diameter, Double Loop1
1866U1--8292--1Cap, Insulating 0.125 OD Black3
OPTION 2 -- UPPER FRESH AIR INSTALLED WITH STANDARD FASTENERS
See Previous Section for Standard Parts and use with Items Below:
1934--06154--00Screw, Hex Head, 1/4--20 X 1.00 Inch Long -- TIR2
2034--00655--08Screw, Hex Head, 1/4--20 X 1.00 Inch Long6
OPTION 2-- UPPER FRESH AIR INSTALLED WITH STAINLESS STEEL FASTENERS
See Previous Section for Standard Parts and use with Items Below:
1934--66627--00Screw, Hex Head, 1/4--20 X 1.00 Inch Long -- TIR2
2066U1--5361--50Screw, Hex Head, 1/4--20 X 1.00 Inch Long6
7T-340PL
1.2UPPER FRESH AIR (Continued)
ItemPart NumberDescriptionQty
OPTION 3 -- UPPER FRESH AIR INSTALLED WITH SCREENS, 10 X 10
258--04376--01Panel, Access with Screen, Medfly, 10 X 10 -- Includes:1
366U1--5562--2Plug Button, 1.25 Inch Diameter Hole1
568--12940--00Cover, Top, Evaporator Access Panel1
642--00296--01Gasket, Evaporator Access Panel1
742--00327--00Gasket, 0.26 X 0.50 Half--Round1
842--00407--00Gasket, 0.50 Fresh Air Disc1
968--12933--00Disc, 12.35 Inch Diameter1
1034--06185--01Screw, Machined, #8--32 X 0.50 with Nylock1
1166U1--5362--2Nut, Wing, 5/16--18, SST1
1266U1--5321--13Washer, Plain 5/16 W Type A, SST1
1334--06053--19Washer, Mylar 1.00 OD X 0.312 ID1
1434--06053--13Washer, Mylar, 1/4 ID X 0.80 OD8
1534--06212--12Washer, Flat, 1/4, SST8
1666CH1--1 172--2Trim, Flexible 2.00 Inches Long1
1758--00969--00Wire Tie 2.80 Inch Diameter, Double Loop1
1866U1--8292--1Cap, Insulating 0.125 OD Black3
1934--06154--00Screw, Hex Head, 1/4--20 X 1.00 Inch Long -- TIR2
2034--00655--08Screw, Hex Head, 1/4--20 X 1.00 Inch Long6
OPTION 3 -- UPPER FRESH AIR INSTALLED WITH SCREENS, 16 X 16
See Previous Section for Standard Parts and use with Items Below:
1934--06154--00Screw, Hex Head, 1/4--20 X 1.00 Inch Long -- TIR2
2034--00655--08Screw, Hex Head, 1/4--20 X 1.00 Inch Long6
2158--04251--00Screen, Medfly, USDA, 16 X 162
8T-340PL
1.2UPPER FRESH AIR (Continued)
ItemPart NumberDescriptionQty
OPTION 4 -- UPPER FRESH AIR INSTALLED WITH VENT POSITIONING SENSOR
79--66626--00Panel Assembly, Access, White -- Includes:1
1
79--66626--01Panel Assembly, Access, Orange -- Includes:1
258--04376--05Panel, Access1
366U1--5562--2Plug Button, 1.25 Inch Diameter Hole1
434--06185--01Screw, Pan Head, #8--32 X 0.50 with Nylock1
68--12940--03Cover, Top, Evaporator Access Panel, Orange1
642--00296--01Gasket, Evaporator Access Panel1
742--00327--00Gasket, 0.26 X 0.50 Half--Round1
842--00407--00Gasket, 0.50 Fresh Air Disc1
68--12933--07Disc, 12.35 Inch Diameter, White1
9
68--12933--05Disc, 12.35 Inch Diameter, Orange1
1066U1--5362--2Nut, Wing, 5/16--18, SST1
1134--06053--19Washer, Mylar 1.00 OD X 0.312 ID1
1266U1--5321--13Washer, Plain 5/16 W Type A, SST1
1366U1--2552--185Gasket1
1434--06053--13Washer, Mylar, 1/4 ID X 0.80 OD8
1534--06212--12Washer, Flat, 1/4, SST8
1666CH1--1 172--2Trim, Flexible 2.00 Inches Long1
1758--00969--00Wire Tie 2.80 Inch Diameter, Double Loop1
1866U1--8292--1Cap, Insulating 0.125 OD Black (NOT USED IN THIS ASSEMBLY)3
1934--06154--00Screw, Hex Head, 1/4--20 X 1.00 Inch Long -- TIR2
2034--00655--08Screw, Hex Head, 1/4--20 X 1.00 Inch Long6
2158--04251--00Screen, Medfly, USDA, 16 X 16 (NOT USED IN THIS ASSEMBLY)2
2234--00928--02Rivet, Blind 0.125 Inch Diameter 0.126--0.1872
23NSSNut, Self Lock, 1/4--201
24NSSPlate2
25NSSBracket, Sensor2
26NSSSensor, Rotary Position1
2722--01613--10Plug, 4--Pin1
2822--01613--13Contact, Socket #163
2922--01613--11Lock, 4--Pin -- Secondary1
3022--01660--08Plug, 0.12 Inch Diameter X 0.581
9T-340PL
1.3UPPER FRESH AIR -- eAutoFresh
11
12
10
9
8
1314
7
7
FOR PANEL ASSEMBLY
SEE SECTION 1.4
5
6
1
3
4
12
13
15
16
17
18
19
32
33
7
20
21
7
2212
12
23
24
31
29
30
2
3
4
29
7
28
34
12
27
22
26
25
24
35
10T-340PL
1.3UPPER FRESH AIR -- eAutoFresh (Continued)
ItemPart NumberDescriptionQty
OPTION P -- UNITS PROVISIONED FOR eAutoFresh OPTION
79--66643--00eAutoFresh, White Panel -- SEE SECTION 1.41
NS
79--66643--01eAutoFresh, Orange Panel -- SEE SECTION 1.41
134--06154--00Screw, Cap Hex Head 1/4--20 X 1.00 TIR2
234--00655--08Screw, Cap Hex Head 1/4--20 X 1.006
334--06053--13Washer, Retaining 0.19 ID X 0.80 OD (0.250)8
434--06212--12Washer, Plain 1/4 N Type A8
558--04251--01Screen, 16 X 16 Mesh1
658--04251--02Screen, 16 X 16 Mesh1
766U1--3882Wire Tie, 1/16--1 3/4 Self--Locking11
822--01835--00Connector, 5 Socket Weatherpack1
940--00601--05Tube, Support 1/4 OD X 0.040 Wide1
1058--00065--77Grommet, 0.38 ID X 1.25 OD1
1110--00388--00Powerpack, Stepper Motor1
1266U1--5371--6Screw, Machine Hex Head #10--24 X 0.750 Slotted10
1366U1--5321--8Washer, Plain #10 Type A4
1466CH1--1 172--2Trim, Flexible 2.00 Long1
1510--00398--00Sensor, Carbon Dioxide -- Includes:1
1622--01613--10Plug1
1722--01613--11Lock1
1822--06163--15Socket1
1958--00065--78Grommet, 0.25 ID X 1.25 OD1
2022--01613--08Receptacle, 4 Pin1
2122--01613--09Lock, Secondary 4 Pin (R)1
2240--00297--00Coupling, 1/8 X 1/8 Pipe Thread2
2340--00108--03Coupling, Half Union1
2434--00373--07Clamp, Tube 0.62 Diameter Cushion2
2530--00415--01Filter Assembly, Sample Air, 1/8 NPT1
26KA70PP048Fitting, Hose 1/8 ID Barb X 1/8 NPT1
2768--14738--00Bracket, Mounting, 0.090 Thick Aluminum1
2858--04497--04Tube, 1/4 Inch OD X 7.75 Inches Long1
2958--04497--01Tube, 1/4 Inch OD X 6.25 Inches Long2
3040--00640--00Union, Bulkhead Double Brb/Comp Align1
3158--00065--84Grommet, 0.25 X 0.50 X 0.187 Panel1
3268--14739--00Bracket, 0.063 Thick Aluminum1
3334--00928--03Rivet, Blind, 0.125 Diameter, 0.188--0.2502
3444--00361--00Clip, Retaining 0.88--1.00 Wire Mounting2
3522--01777--03Contact Socket, 20 AWG7
11T-340PL
1.3UPPER FRESH AIR -- eAutoFresh (Continued)
11
12
13
9
7
7
FOR PANEL ASSEMBLY
SEE SECTION 1.4
13
15
16
17
18
29
7
28
27
7
24
7
22
23
25
24
26
12T-340PL
1.3UPPER FRESH AIR -- eAutoFresh (Continued)
ItemPart NumberDescriptionQty
OPTION 1 -- eAutoFresh INSTALLED
79--66643--00eAutoFresh, White Panel -- SEE SECTION 1.41
NS
79--66643--01eAutoFresh, Orange Panel -- SEE SECTION 1.41
766U1--3882Wire Tie, 1/16--1 3/4 Self--Locking11
940--00601--05Tube, Support 1/4 OD X 0.040 Wide1
1110--00388--00Powerpack, Stepper Motor1
1266U1--5371--6Screw, Machine Hex Head #10--24 X 0.750 Slotted10
1366U1--5321--8Washer, Plain #10 Type A4
1510--00398--00Sensor, Carbon Dioxide -- Includes:1
1622--01613--10Plug1
1722--01613--11Lock1
1822--06163--15Socket1
2240--00297--00Coupling, 1/8 X 1/8 Pipe Thread2
2340--00108--03Coupling, Half Union1
2434--00373--07Clamp, Tube 0.62 Diameter Cushion2
2530--00415--01Filter Assembly, Sample Air, 1/8 NPT1
26KA70PP048Fitting, Hose 1/8 ID Barb X 1/8 NPT1
2768--14738--00Bracket, Mounting, 0.090 Thick Aluminum1
2858--04497--04Tube, 1/4 Inch OD X 7.75 Inches Long1
2958--04497--01Tube, 1/4 Inch OD X 6.25 Inches Long2
13T-340PL
1.4UPPER FRESH AIR -- eAutoFresh PANEL ASSEMBLY
1
2
3
4
FOR SCREENS
SEE SECTION 1.3
5
6
7
8
9
10
11
10
11
13
12
14
16
17
18
15
16
17
19
21
20
17
18
22
23
24
14T-340PL
1.4UPPER FRESH AIR -- eAutoFresh PANEL ASSEMBLY (Continued)
OPTION 1 -- UNITS NOT PROVISIONED FOR TRANSFRESH (UNIT EQUIPPED WITH
BULKHEAD OPTION AND NO RECORDER OPTION)
--76--00681--02Kit, TransFresh Field Installation (For units with NO TransFresh Provision)
-- Includes ALL OF OPTION 1 AND ITEMS BELOW:
966CH1--1012--40Insulation Tube, 1.125 ID x 2.50 Inches1
1058-04290-00Bulkhead Fitting1
1122--01602--02Bushing, 0.625 ID x 0.88 Long1
1222--01602--03Ring, 0.312--0.375 Gotcha1
1322--01733--01Nut, Straight -- Includes:1
1434--00928--04Rivet, Blind, 0.125 Diameter, SST2
NOTE
* Contact -- TransFresh Corp., P.O. Box 1788, Salinas, CA 93902 to order these parts.
--
--
17T-340PL
1.6BULKHEAD PENETRATION -- UPPER AIR EXCHANGE
3
4
10
11
12
1
2
OPTION 1
5
6
7
8
9
OPTION 2
ItemPart NumberDescriptionQty
OPTION 1 -- NOT INSTALLED
158--00616--00Plug, Hole, 2.00 Inch Diameter X 0.12 Panel1
266U1--5562--2Plug Button, 1.25 Inch Diameter Hole1
OPTION 2 -- STANDARD INSTALLED
358--04290--01Fitting, Bulkhead1
434--00928--04Rivet, Blind, 1/8 Inch Diameter, Grip Range 1/4 -- 5/164
522--01602--02Bushing, 0.625 ID X 0.88 Inches Long1
658--04302--01Grommet, 0.25 ID X 1.25 Inches Long1
769NT35--8258Disc, 0.040 Thick Aluminum1
822--01602--03Gotcha Ring, 0.312--0.3751
922--01733--01Nut, Straight (With TIR Holes)1
1034--06154--00Screw, Captive, Hex Head, 1/4--20 X 1.00 TIR1
1134--06053--00Washer, 0.250 ID X 0.800 OD1
1266U1--5321--7Washer, Plain, 1/4 W, Type A1
18T-340PL
1.7THERMOMETER PORT
3
4
2
1
ItemPart NumberDescriptionQty
OPTION 1 -- SUPPLY AIR PORT
166U1--8662Cap and Chain Assembly1
262--10557--00Label1
OPTION 2 -- RETURN AIR PORT
366U1--8662Cap and Chain Assembly1
462--10557--00Label1
OPTION B -- SUPPLY AND RETURN PORTS
166U1--8662Cap and Chain Assembly2
262--10557--00Label2
366U1--8662Cap and Chain Assembly1
462--10557--00Label1
19T-340PL
1.8RAIN GUTTERS
1
2
3
4
20T-340PL
1.8RAIN GUTTERS (Continued)
ItemPart NumberDescriptionQty
OPTION 1 -- BOLTED
169NT35--3997--1Gutter, Rain (Bolted, Standard -- Left Side)1
269NT35--3987Gutter, Rain (Bolted, Standard -- Right Side)1
OPTION 4 -- RIVETED
368--12417--00Gutter, Rain (Riveted -- Right and Left Side)2
434--00928--13Rivet, Blind 0.187 Inch Diameter, 0.126--0.2506