Carrier 260L, 1300L User Manual

OWNER’S MANUAL
MIRACOOL™ GLASS DOOR MERCHANDISER
260L - 1300L
300L 750L
a79-13
1300L
Sales Office: P.O. Box 5932
Spartanburg, S.C. 29304-5932
Technical Service: 1-800-558-7627
Parts Order Fax: 1-800-262-9381
Printed in Mexico 6-06 79BC560002-01_C
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
CONTENTS
Page
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNIT INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
LOCATE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LEVEL UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALL SHELVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CONDENSATE DISPOSAL. . . . . . . . . . . . . . . . . . . . . . . . . . 5
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,7
PRELIMINARY CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INITIAL START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
REFRIGERATION SYSTEM SERVICE . . . . . . . . . . . . 8-13
COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SERVICE AND TROUBLESHOOTING . . . . . . . . . . . . . . . 8
MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14,15
LAMP REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CONDENSATE REMOVAL . . . . . . . . . . . . . . . . . . . . . . . . 14
CONDENSER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CABINET EXTERIOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
INTERIOR SURFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GENERAL
These instructions cover the installation, operation, and maintenance of Carrier Miracool™ series glass door merchandiser units, sizes 260L, 300L, 750L, 1100L, and 1300L.
UNIT INSPECTION
Examine all packages for damage to packaging mate­rial. Damage to external packaging may have resulted in unit damage. Check packages for all accessories and components, including legs, casters, and shelves. File a claim immediately with the shipping company if shipment is damaged or incomplete.
INSTALLATION
LOCATE UNIT
Refer to Figure 1 for unit components. Units are designed for indoor placement only. Provide at least 3 in. of space between unit cabinet and any adjacent wall or fixture. Remove skid base by removing the retaining screws (4 hex head bolt screws). If optional casters will be used, unit must be located on flat, level surface. Refer to Table 1 for a list of standard parts.
TABLE 1 — STANDARD PARTS
PART
Refrigeration Cartridge X111
Shelves X4510
Shelf Clips X162040
Instruction Manual ——111
Leveling Feet X444
Lamps X122
NOTE: Parts shown are for standard units. Quantity of shelves and clips may vary based on factory-supplied options.
FAC TOR Y
INSTALLED
FIELD
INSTALLED
260L, 300L 750L 1100L, 1300L
UNIT SIZE
Quantity
2
FLUORESCENT LAMP SIGNBOARD (SIZES 750L, 1100L, AND 1300L ONLY)
UNIT DATA LABEL (INSIDE COOLER IN UPPER LEFT CORNER)
SHELF
PRODUCT CHAMBER
INTERNAL FLUORESCENT LAMP — SIZE 750L (SIZE 260L, 300L — ALONG TOP; SIZE 1100L, 1300L — IN CENTER)
FRONT GRILLE
CARTRIDGE COMPARTMENT
SERVICE CORD
LEVELING FOOT
FRONT VIEW
GRILLE RETAINING SCREW
WOOD SKID RETAINING SCREW, IF USED (HEX HEAD BOLT SCREW)
WOOD SKID
REAR VIEW
LIGHTING CORD (RIGHT CONNECTOR)
POWER CORD (LEFT CONNECTOR)
UNIT WITH FRONT GRILLE REMOVED
FIGURE 1 — MIRACOOL™ BOTTLE COOLER UNIT COMPONENTS (Size 750L Shown)
a79-1
3
LEVEL UNIT
To provide adequate condensate drainage and proper door alignment and operation of unit, the unit cabinet must be level. Leveling feet are factory installed. Remove refrigeration system cartridge for easier access to back feet.
Before servicing unit, disconnect electrical service. On sizes 1100L and 1300L, turn disconnect switch (located on power cord) to the OFF position. Failure to disconnect electrical service could result in elec­trical shock and cause personal injury or death.
UNPLUG CARTRIDGE POWER AND LIGHTING CORDS
a79-2
TO REMOVE CARTRIDGE
1. After disconnecting the unit from the power supply, remove the grille retaining screw located in the upper-most part of the grille. (See Figure 1.)
2. Lift the grille up and away from the unit.
3. Unplug the power supply and lighting supply cords located in the front of the cartridge (Figure 2).
4. Using a pair of wire cutters, cut wire tie that secures lifting rods at center of front base rail. (See Figure 2.)
5. Take hold of the end of each lifting rod and rotate each approximately 90-degrees upward so that they are nominally vertical (Figure 3.) The car­tridge should be disengaged from the cabinet and resting on the base of the cabinet assembly. Han­dling holes are located on either side of the car­tridge near the top and along the side of the cartridge (Figure 4). Grasp the cartridge by these holes and slide the unit forward from the cabinet until the cartridge is free. Use caution to ensure that power and electrical cords do not get pinched between the cartridge and cabinet while removing cartridge.
TO LEVEL UNIT — The door is equipped with gravity assisted cams and will not function properly without proper leveling of cabinet. Adjust feet using adjustable wrench so that unit sits approximately level to floor and door closes properly. For best door operation, adjust leveling feet so that cabinet has
1
a
/16-in. rake or slant from front to back. Optional
casters are available to replace leveling feet.
NOTE: If casters are not used, local codes may require cabinet to be sealed around the perimeter of the cabi­net base. Consult local sanitation codes. Use only seal­ant material approved for this use, such as Dow Corning #732.
CUT WIRE TIE THAT SECURES LIFTING RODS TO BASE
FIGURE 2 — PREPARE CARTRIDGE FOR REMOVAL
CARTRIDGE POWER AND LIGHTING CORDS
a79-3
FIGURE 3 — ROTATE LIFTING WIRES IN
DIRECTION SHOWN
PULL THE CARTRIDGE USING THE HANDLING HOLES ON SIDES
a79-4
FIGURE 4 — REMOVE CARTRIDGE
4
INSTALL SHELVES
Product shelves and a bag containing shelf support clips are packed inside the unit. Refer to Table 1 to verify quantity of shelves and shelf supporting clips. Bottom shelf must be placed on interior floor and should be inserted into the two retainer clips provided at the rear corners of the unit floor.
Improper shelf clip installation may cause shelf and/ or product to fall which could result in personal injury or damage to the unit.
Do not overload the shelves. The unit is designed to use all the shelves provided, installed in equally spaced configuration. Failure to install shelves cor­rectly could result in personal injury or damage to the unit. If fewer shelves or a different installation configuration is desired, contact the manufacturer to ensure that shelf overloading will not occur.
TO INSTALL SHELVES — Refer to Figures 5 and 6.
1. Determine proper location for shelf clips. Refer to the numbers on the pilaster to ensure that all clips are properly located.
2. Insert top tab of the shelf clip into the desired hole of the pilaster. The retaining tab should be facing upward as shown in Figure 5.
3. Rotate the clip downward and insert the bottom tab into the appropriate hole on the pilaster. If necessary, squeeze the clip slightly during installation.
4. Install all remaining clips as described above.
5. Install shelves onto clips so that the product retention bar is facing upward. Be careful not to dislodge clips during shelf installation.
6. Shelves must be placed so that the retaining tab on the shelf clip captures the shelf as shown in Figure 6.
7. Before loading the shelf, ensure that the shelf is resting on each of 4 clips and that the clips are installed as shown in Figures 5 and 6.
CONDENSATE DISPOSAL
The evaporator drain pan is located in the base of the cartridge. Airflow in cartridge compartment hastens condensate evaporation so that external drain plumb­ing is not required.
TOP TAB FULLY INSERTED INTO SLOT
BOTTOM TAB FULLY SEATED
PROPERLY INSTALLED CLIP
RETAINING TAB
SHELF CLIP
a79-5
IMPROPERLY INSTALLED CLIP (UPSIDE DOWN)
BOTTOM TAB
FIGURE 5 — SHELF CLIP INSTALLATION
PILASTER
SHELF RETAINED BY TAB
a79-6
PRODUCT RETENTION BAR
FIGURE 6 — PROPER INSTALLATION OF
SHELF ON CLIP
TOP TAB
5