Be sure to read this instructions before you use the equipment.
Keep this instructions on hand for reference to ensure optimum preformance.
International ENERGYSTAR® Office Equipment Program
As an ENERGY STAR partner, Canon Electronics Inc. has determined that this product meets the ENERGY STAR guidelines for energy efficiency.
The International ENERGY STAR Office Equipment Program is an international program that promotes energy saving through the use of computers and other office
equipment. The program backs the development and dissemination of products with
functions that effectively reduce energy consumption. It is an open system in which
business proprietors can participate voluntarily. The targeted products are office equipment such as computers, monitors, printers, fax machines, copiers and scanners.
Their standards and logos are uniform among the participating nations.
FCC REGULATIONS (For 120V models)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Do not make any changes or modifications to the equipment unless otherwise specified in the manual. If
such changes or modifications should be made, you could be required to stop operation of the equipment.
RADIO INTERFERENCE REGULATIONS (For 120V models)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus
set out in the Interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the
Industry Canada.
RÈGLEMENT SUR LE BROUILLAGE RADIOÉLECTRIQUE (For 120V models)
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils
numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques",
NMB-003 édictée par l'lndustrie Canada.
Für EMVG
Dieses Produkt ist zum Gebrauch im Wohnbereich, Geschäfts-und Gewerbebereich sowie in
Kleinbetrieben vorgesehen.
MODEL NAMES
Model Microfilm Scanner 350 is identical to model M31023.
Model Microfilm Scanner 350 is the sales name of model M31023.
• Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation in the United
States and/or other countries.
• ISIS is a trademark of Pixel Translations, A Division of Captiva Software Corporation in the United
States.
• Kodak is a trademark of Eastman Kodak Company.
• 3M is a trademark of Minnesota Mining Manufacturing Company.
• TUSCAN is a trademark of the TUSCAN Corporation.
• ENERGY STAR is a U.S. registered mark.
Other brand and product names may be trademarks or registered trademarks of their respective companies.
INTRODUCTION
These instructions describe the operating procedures for the Canon
Microfilm Scanner 350. After you set up the unit, keep this manual
in a convenient location so you can find it when you need it.
1
Conventions
A few symbols and notations alert you to additional information
that will make operation of the scanner more efficient, trouble
free, and safe.
(➞P.13)
A number preceded by an arrow and enclosed in parentheses shows
you the page number that contains more information about the
previous statement or paragraph.
WARNING
Warnings are provided for your safety and contain extremely important information. Failure to observe the
instructions provided in a warning could result in death
or serious injury to yourself or your co-workers.
CAUTION
Caution notices are also provided for your safety and
contain important information. Failure to observe the
instructions provided in a caution notice could result in
serious injury to yourself or your co-workers or damage to the equipment.
HEAT CAUTION
There will be cautions for heat injury caused by hot
sections. For your safety, be sure to follow instructions
given in these cautions.
Important
These important notes contain important information
on procedures that must be followed or actions that
must be avoided. Failure to observe a request could
result in damage to the equipment or a malfunction.
Notes
Notes provide additional tips or advice that can save
your time and effort in using the scanner.
INDEX .................................................................................................... 55
4
10cm
■ BEFORE YOU BEGIN ... ■
BEFORE YOU BEGIN ...
To ensure safe, efficient operation, read the follow precautions
and recommendations before you choose a location and set up the
system.
Work Safety!
Choosing a safe location
■ To ensure adequate space for ventilation, operation, and mainte-
nance, make sure there is enough space around the system on all
sides. To prevent overheating, never block the ventilation slots.
10cm
50cm
■ Avoid exposure to direct sunlight. When exposure to sunlight is
unavoidable, install curtains to protect the unit.
■ Avoid a dusty location. Dust can adversely affect the internal parts
of the unit.
■ Do not set up and use the unit in a location where the unit is ex-
posed to water, steam, or high humidity. Keep all liquids away
from the unit.
5
■ BEFORE YOU BEGIN ... ■
■ Avoid areas like laboratories where fumes from ammonia, acetone,
or other volatile chemicals are present. Never use any kind of
volatile, flammable spray near the unit.
■ Never set up the unit in an area where flammable substances like
alcohol, thinner, or other organic chemicals are present.
■ Select a flat, stable surface that can support the 26 kg (57.2 lb)
weight of the unit.
■ Choose a location that is free of excessive vibration.
■ Avoid a location subject to sudden or wide changes in tempera-
ture. Condensation inside the unit can cause poor image quality.
Use the unit in a location within these ranges for temperature and
humidity.
Temperature10˚C to 32.5˚C (50˚F to 90.5˚F)
Humidity10% to 80% RH
■ Do not place the unit near large speakers, a radio, a television, or
any other type of equipment that can generate a strong magnetic
field.
6
■ BEFORE YOU BEGIN ... ■
Power supply
If you have any questions about the power source at
your work site, contact your supplier or the power company.
■ The unit should have an independent power source that is not
shared with any other electrical device. If you have to use an extension cord or power strip, make sure the total ampere rating for
all the equipment does not exceed the ampere rating of the extension cord.
■ Do not place anything on the power cord, and do not locate the
unit where people working around the unit will walk on the cord.
■ Do not bundle the power cord or wrap it around an object like a
table or chair leg. The area around the unit should be clear of all
obstacles. In case of an emergency, you should be able to reach
the power source quickly to unplug the cord.
■ To remove the power cord from the power outlet, grasp the head
of the plug firmly to remove it. Never pull on the cord to remove
the plug from the power outlet. Never touch the power cord with
wet hands.
7
■ BEFORE YOU BEGIN ... ■
Daily handling
Before using the equipment, make sure you and your co-workers
read the following warnings about using this equipment.
PAY ATTENTION TO THESE WARNINGS! FAILURE
TO FOLLOW THESE WARNINGS COULD RESULT
IN INJURY FROM FIRE OR ELECTRICAL SHOCK!
WARNING
■ Always observe these warnings when using the scanner. Failure
to follow these warnings could result in injury due to fire or electric shock.
■ Do not set up the scanner in a location close to flammable sol-
vents such as alcohol and paint thinners.
■ Do not cut, damage or modify the power cord, do not pull or bend
the power cord excessively, and do not place heavy objects on the
power cord.
■ Never plug in or unplug the power cord with wet hands.
■ Do not place objects on top of the scanner as such objects could
fall and cause injury. Do not plug the scanner into a multi-socket
adapter.
■ Do not knot or bundle the power cord, and ensure that the plug is
pushed fully into the power outlet.
■ Use only the power cord supplied with the scanner.
■ Do not attempt to disassemble or modify the scanner. There are
no user-serviceable parts inside the scanner.
■ Do not use flammable sprays or aerosols near the scanner.
■ Switch the scanner off and unplug the power cord before cleaning
the scanner.
■ To clean the unit, use a cloth lightly dampened with water or a
mild detergent.
■ If the scanner emits an unusual noise, odor, smoke or sparks, or if
the scanner will not function when switched on, immediately
switch the scanner off, unplug the power cord and contact an authorized Canon dealer or service center.
■ Before you move the scanner even a short distance, switch the
scanner off and unplug the power cord.
CAUTIONS
■ Do not set up the scanner on sloping, wobbly or otherwise un-
stable surfaces or in locations affected by excessive vibration. The
scanner could cause injury if it falls over or slides off the surface.
■ Do not block the ventilation slots as this could result in a fire due
to the build up of heat inside the scanner.
■ Do not place vessels containing liquids (cups, vases, etc.) or small
metal objects (paper clips, staples, necklaces, etc.) on top of the
scanner. Liquids or metal objects falling into the scanner could
cause an electric shock or fire. If any liquids or metal objects fall
into the scanner, immediately switch the scanner off, unplug the
power cord and contact an authorized Canon dealer or service
center.
■ Do not set up the scanner in dusty or humid locations as this could
result in an electric shock or fire.
■ Do not place heavy objects on top of the scanner as such objects
could fall and cause injury.
8
■ BEFORE YOU BEGIN ... ■
■ Use only a power supply having the rated voltage. The use of
other voltages could result in a fire or electric shock.
■ Always unplug the power cord by grasping the plug itself. Pulling
on the power cord can damage the cord so that the core wires are
exposed or snapped and could cause a fire or electric shock.
■ Do not use an extension power cord as this could cause a fire or
electric shock.
■ Keep the area around the power outlet free of obstacles to ensure
that the scanner can be unplugged quickly in the event of an emergency.
■ Take care not to tip water or flammable solvents such as alcohol,
thinners or benzene into the scanner as this could result in a fire or
electric shock.
■ If the scanner will be left unused for a lengthy
period, always unplug the scanner as a safety measure.
■ Avoid touching internal scanner components when you perform
routine cleaning or maintenance such as changing the lamp. Some
internal components generate high temperatures or high voltages.
To avoid injury such as burns or electric shocks, take care also
that metal objects such as necklaces or bracelets do not come into
contact with internal scanner components.
■ To avoid injury when you are moving the scanner, take care not
to put your hands on the metal protrusions on the underside of
the scanner unit.
HEAT CAUTIONS
■ Avoid touching internal scanner components when you perform
routine cleaning or maintenance such as changing the lamp. Some
internal components generate high temperatures or high voltages.
9
■ BEFORE YOU BEGIN ... ■
Features of the Microfilm Scanner 350
❏ Space saving
The economical design of this compact film scanner requires less
space on your desk or work table.
❏ Automatic film polarity detection
The unit automatically detects the presence of negative film or
positive film and sets itself accordingly.
❏ Uses a variety of film formats
A wide variety of roll/fiche carriers or auto carriers can be installed so you can use several film formats like microfiche, aperture card, and roll film.
❏ Easy operation
Operations like border removal and image trimming can be performed at the press of a few keys before scanning.
❏ Reader-Printer mode (CapturePerfect)
This is a mode which enables the scanner to perform the same
Reader-Printer functions as a Microfilm printer does. Scanned images can be printed out directly through a designated printer.
❏ Multiple scanners compatible
The unit enables the user to connect multiple scanners to a personal computer and use a printer that is connected to the personal
computer. (➞ P.19, “Connecting to a Computer”)
❏ Expandability
By adding the optional DMP board, sold separately, in the Microfilm Scanner 350, the scanner can be used as a Digital Microfilm
Printer (DMP).
Before you use the equipment, make sure you and your co-workers read the following warnings about using this equipment.
10
■ BEFORE YOU BEGIN ... ■
About operation modes
The following operating modes are available with this scanner.
Select one of the following modes according to your system environment before using the scanner. For details, contact your service representative.
❏ Scanner mode
Using this scanner in connection with a personal computer, the
image projected on the scanner’s screen can be saved in the PC as
image data, or printed out through a printer connected to the PC.
❏ DMP mode
By installing the optional DMP board in the scanner and connecting it to a DMP-dedicated printer, the MS350 can be used as a
digital microfilm printer (DMP). The image projected on the
scanner’s screen can be printed out through the DMP-dedicated
printer. In this case, no personal computer is required.
❏ Reader-printer mode
Using the CapturePerfect bundled with the MS350, the scanner
that is set to the Scanner mode will operate as if it is set to the
DMP mode. The image projected on the scanner’s screen can be
printed out directly through a printer connected to the personal
computer. In this case, however, the image cannot be saved in the
PC as image data.
❏ Multipule scanner mode
This mode is a part of the Reader-Printer mode function and enables you to use multiple scanners connected to one personal computer. (➞P.19 “Connecting the computer”)
When the DMP board is installed in this scanner, switch
the “DMP mode” and “scanner mode” in the user mode
before use. (➞P.38 “USER MODE”)
If the computer is connected with the user mode set to
“DMP mode” when the DMP board is installed in this
scanner and the MS350 is used as a scanner, the operation panel may not be operable or other problems
may occur.
11
■ BEFORE YOU BEGIN ... ■
Unpacking: What's in the box?
When you unpack the box, use the checklist below to make sure
that you have everything. If anything is missing, contact your supplier.
■ Microfilm Scanner 350
■ Keyboard
■ Lens holder
■ Setup CD
ISIS/TWAIN Driver
CapturePerfect
■ Power cord
■ Function Key label (➞P.37 “Setting the function keys”)
■ Instructions (This manual)
■ Canon Software License Agreement
■ Warranty Card (U.S.A. and Canada only)
12
■ BEFORE YOU BEGIN ... ■
Options
In addition to the accessories provided in the product package, a
number of optional accessories that are required for using the scanner, such as carriers and lenses, are also sold, as well as other
optional accessories that can be purchased as needed. Contact your
nearest authorized Canon Dealer for details.
■ Carriers (➞P.15 “Preparing the carrier”)
Multiple carriers can be used for all types of film, including cartrige
film, microfiche, jacket film and aperture cards.
Siuce the scanner does not come with a carrier, purchase the carrier best suited to your needs.
■ Installation Kit (➞P.15“Preparing the carrier”)
Some carriers require an Installation Kit. Contact your nearest
authorized Canon service outlet for details.
■ Lenses (➞P.16 “Preparing the lens”)
One fixed-focus lens and five zoom lenses are available for the
Microfilm Scanner 350. Since the scanner dose not come with a
lens, purchase the lenses best suited to your needs.
■ DMP board
This optional board is required to use the scanner in the DMP
mode.
■ Fileprint 250/450 (fiP.20 “Preparing the printer”)
These printers are DMP-dedicated printers that support the scanner when used in the DMP mode.
■ Framing Kit (➞P.36 “Trimming”)
This optional unit allows you to selectibely scan a portion of the
image projected onto the screen. This Framming Kit is required
in order to use the Trimming function provided by the scanner.
■ Foot switch
This is an underfoot switch that provides the same function as the
Start key on the operational panel.
13
■ BEFORE YOU BEGIN ... ■
Operation panel
Provides keys that allow you to perform
settings for image adjustment or film
mode selection.
Important parts and their functions
Before you use the unit, take a few minutes to become familiar
with the names of the important parts.
Screen
Displays images and allows you to view
images before you print them.
DIN connector
Allows you to connect a
cable for the Autocarrier
100C, 100R, 100M, FS
Controller I or Roll/Fiche
carrier 200.
Power switch
Allows you to turn power on and off.
Carrier stage
Holds an interchangeable carriers.
Lens holder
Holds an interchangeable
lens.
Lamp unit
Holds the lamp for the main
source of illumination. Remove
to change the halogen lamp.
Keyboard
Use to adjust the screen image, set
the print mode, execute printing, and
control almost all other operations.
14
■ BEFORE YOU BEGIN ... ■
Preparing the carrier
This is a list of all the carriers that can be installed and used with
the Microfilm Scanner 350. For more details about these options,
contact your supplier. For details about installation and operation, refer to the instructions provided with each auto carrier.
The Auto Carrier 100C, 100M and 100R and the FS
Controller I and Roll/Fiche carrier 200 require an optional Installation Kit.
■ Fiche Carrier 190RII
A microfish carrier which allows viewing of fiche, jackets, or aperture cards up to 105 mm x 190 mm.
■ Autocarrier 100C (AC100C)
A motorized auto carrier for 16 mm cartridge films (ANSI, ANSI
ENCLOSED*1, Kodak Ektamate, 3M) that features fast autoloading and high speed film transport.
■ Autocarrier 100M (AC100M)
A motorized auto carrier for 3M or TUSCAN M-Type*2 cartridges
that features fast autoloading and high speed film transport.
■ Autocarrier 100R (AC100R)
A motorized auto carrier for 16 mm or 35 mm film wound on
standard open reels.
■ FS Controller I
A motorized auto carrier for 16 mm cartridge films (ANSI, Kodak
Ektamate, 3M). This carrier is required for reading film marked
with blips for automated image search and retrieval.
■ FS Controller III
A motorized auto carrier for the new 16 mm cartridge films (ANSI,
Kodak Ektamate, 3M). This carrier is required for reading film
marked with blips for automated image search and retrieval.
■ Roll/Fiche Carrier 200
A motorized fiche auto carrier for either fiche, jacket, or aperture
card format film, 16mm/35mm film standard open reels or 3M,
TUSCAN M-Type*2 cartridges.
*1 ANSI ENCLOSED cartridge is defined as ANSI MS-15.
2
*
TUSCAN M-Type is a TUSCAN cartridge with a 3M-type core.
15
■ BEFORE YOU BEGIN ... ■
Preparing the lens
The following types of lenses are available.
Fixed lens
HX7 (x7)
Zoom lenses
HZ01 (x9.5 to x16)
HZ02 (x16 to x32)
HZ03 (x30 to x55)
HZ04 (x20 to x48)
HZ05 (x10 to x24)
Switching the lens
Follow the procedure below to install or exchange lenses.
1. If a lens is already installed, grasp the edge of the holder and
slide it out of the unit.
2. Gently pull the lens holder all the way out.
3. Use one hand to support the base of the holder, and the other
to lift and remove the lens. Proceed carefully, making sure
that the lens does not fall out.
16
Loading...
+ 42 hidden pages