Service Bulletin
Issued by Canon Europa N.V.
Copier Color
Hardware
Model:
iR 5800C
iR 5800CN
iR 6800C
iR 6800CN
Location:
Reverse Paper Delivery Door Assembly
Subject:
Measures for a Duplexing Feeding Assembly Jam (0111)
Detail:
<Symptom>
A Duplexing Feeding Assembly Jam (0111) occurs at Reverse Delivery.
<Cause>
The Reverse Driven Roller (upper) [B] rotates, being pressed against the Inverter Drive Roller (upper) by the
Tension Spring [A]. This Tension Spring [A] is damaged while reaching the end of its life and the Reverse
Driven Roller (upper) [B] does not rotate, causing a paper feed fault and jam (0111) occurs.
Ref No.:
iR6800C-029
(F2-T01-0M3-10074-01)
Date:
November, 2005
P-1 Reverse Paper Delivery Door Assembly
[A] Tension Spring
[B] Upper Reverse Driven Roller
(1/2)
iR6800C-029
<Factory Measures>
In order to improve the durability of the Tension Spring, enlarge the wire diameter of the spring from 0.4mm to
0.45mm and the Coil Diameter from 2.8mm to 3.45mm.
Service Work:
When the foregoing symptom occurs, replace the Tension Springs on the front and backside with a new type at
the same time.
Service Parts:
No. Part number Description Q'ty I.C. P.C.
Old FU5-2139-000
1
New FU5-2139-040 0->2 Y
Old FM2-0482-000 REVERSE PAPER
2
New FM2-0482-050 0->1 Y
Affected machine:
iR6800C 230V EUR JKH01524 and later
OTHERS JKL00019 and later
120V OTHERS JJM04766 and later
iR6800CN 230V EUR JKP03740 and later
OTHERS JKM00228 and later
iR5800C 230V EUR KEN00689 and later
OTHERS KEP00007 and later
120V OTHERS KEM01615 and later
iR5800CN 230V EUR KES01064 and later
OTHERS KET00044 and later
SPRING, TENSION
DELIVERY DOOR
ASSEMBLY
2->0 N
355
1->0 N
355
(2/2)