Permanent countermeasure added to factory measures.
Location:
Subject:
Countermeasure against the error occurrence “E202-0001/0002”, due to the breakage of IC6
Detail:
<Symptom> The errors “E202-0001/0002”, occur due to the breakage of IC6 [1] <Cause> The installation or uninstallation of the Flexible Flat Cable [2], which controls the current flow into the Scanner Drive Motor, may not have been done successfully. #34 May be broken, an overcurrent may flow into the Interface PCB, the IC6 [1] may be broken and may lead to occur smoke.
Ref No.:
iR6800C-027 Rev. 1 (F2-T01-0M3-10064-02)
Date:
October, 2005
P-1 INTERFACE PCB ASSEMBLY
[1] IC6 [2] CABLE, FLEXIBLE FLAT
(1/3)
<Factory Measures>
1. Temporary countermeasure
Add chip resistor to C49 (unused part) [3] on the Interface PCB.
P-2 Enlarged view of the Interface PCB
iR6800C-027 Rev. 1
[3] C49 Resistor added part
Revision number sealed place (last two
[4]
figures show the revision number)
P-3 Old type
C49 (unused part) Revision number is 01
P-4 New type
Chip resistor is added to C49
Revision number is 02
(2/3)