Service Bulletin
Issued by Canon Europa N.V.
COPIER B/W
HARDWARE
Model:
iR5570
iR6570
Location:
Internal components (2)
Subject:
A preventive measure against the symptom that the image density is light, which is caused by misalignment and
distortion in the Scanner Unit
Detail:
<Symptom>
The image density is light.
<Cause>
Shock caused during transport of the Main Body and in other occasions creates a misalignment and distortion
in the Scanner Unit which leads to the symptom that the image density is light.
<Factory Measures>
Change the shape of Pressure Spring, add holes for mounting the Leaf Spring to the Scanner Stay (R) [C] and
fix the Leaf Spring [D] with cross-recess screws as to prevent the misalignment and distortion in the Scanner
Unit. Stepped screws for mounting the Scanner Unit is discontinued.
Ref No.:
iR6570-005
(F1-T01-0M5-10018-01)
Date:
August, 2005
(1/4)
Old Pressure Spring
[A]
[B] New Pressure Spring
iR6570-005
[C] Scanner Stay (R)
[D] Leaf Spring
[1] A part of shape change (a bend added)
Service Work:
If the symptom occurs in the product A or B below, re-install the Scanner Unit. If the symptom is not solved,
replace the Laser Scanner Unit by a new one. Be aware that the replacement should be done depending on the
types of product.
Product type A B C
Laser Scanner Assembly Old Old New
Scanner Stay (R) No screw hole With screw holes With screw holes
Leaf Spring None None With the spring
-Product type A and B: Mount the Laser Scanner Unit by using stepped screws.
-Product type B: No need to use the Leaf Spring although it has holes for mounting the Spring.
-Product type C: If it is necessary to replace the Laser Scanner Unit by a new one, be sure that the Leaf Spring
is be mounted.