Service Bulletin
Issued by Canon Europa N.V.
Copier B/W
Hardware
Model:
iR5570
iR6570
Ref No.:
iR6570-007
(F1-T01-0M5-10024-01)
Date:
September, 2005
Location:
Service Manual
Subject:
Service Manual (error code E001/ E004)
Reason:
The Remedy of E001 detail code 03 is changed. E001 detail code 0010 is added. The change and the addition are
described below in blue.
T-1
Code Description Remedy
E001 There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error.
0003 The reading is not 150 deg C or higher or 210
deg C or lower within 30 sec.
-Cheak the connecting of the main/
sub/ shutter thermistors.
-Check the mounting of the main/
sub/ shutter thermistors.
-Exchange the main/ sub/ shutter
thermistors.
-Exchange the DC controller PCB.
E004 The IH power supply is faulty/ the IH control mechanism is faulty.
0010 The power has been turned off and then on
without resetting the error.
-Reset the error
(COPIER>FUNCTION>CLEAR>E
RR)
(1/1)