Campbell Hausfeld RP3300, IN728500AV User Manual

12-Volt DIGITAL Tire
MAKES IT EASY TO DO IT LIKE A PRO chpower.com
Inflation System
Système de gonflement de
pneus NUMÉRIQUE de 12 volts
Sistema DIGITAL de inflado de
Operating Instructions
Instructions d’Utilisation
Manual de Instrucciones
RP3300
FRANÇAISE: Page 8 ESPAÑOL: Página 14
IN728500AV 11/09
Table of Contents
Description. . . . . . . . . . . . . . . . . . . . . . . . . 3
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . 3
Safety Guidelines . . . . . . . . . . . . . . . . . . . 4
Safety Symbols . . . . . . . . . . . . . . . . . . . . . 4
Important Safety Information. . . . . . . . 4
Instructions Pertaining to a Risk of Fire, Electric Shock, or
Injury to Persons . . . . . . . . . . . . . . . . . . 4
California Proposition 65 . . . .. . . . . . . 4
General Safety. . . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 5
For Low Pressure Inflation - Inflation Of Items That Require Less
Than 20 psi. . . . . . . . . . . . . . . . . . . . . . . . 5
For Standard Tire Inflation - Inflation Of Tires Between
20 psi and 99 psi . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . 6
Technical Service . . . . . . . . . . . . . . . . . . . 6
Troubleshooting Chart . . . . . . . . . . . . . . 6
Limited Warranty . . . . . . . . . . . . . . . . . . . 7
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
For parts, product and service information
Visit: www.chpower.com Call: Customer Service at 1-800-543-6400
Address any correspondence to: Campbell Hausfeld Attn: Customer Service
100 Production Drive
Harrison, OH 45030 U.S.A.
Operating Instructions
12-Volt DIGITAL Tire Inflation System
Description
The RP3300 12-volt inflator has a high pressure air hose for emergency roadside tire inflation and to inflate bicycle tires, soccer balls, and other sports equipment. This inflator includes a work light and a red flashing light for nighttime emergencies. A 15-amp fuse is located inside the 12-volt DC plug.
Unpacking
When unpacking this product, carefully inspect for any damage that may have occurred during transit.
On/Off Button
On/Off Button for
for Work Light
Emergency Light
Work Light
Specifications
Model RP3300
Maximum Pressure: 99 psi
Weight: 4.0 lbs
Voltage: 12-Volt DC
Amp Draw: 9 amp @ 0 psi
14 amp @ 99 psi
Cord Length: 10 feet
* 12-Volt DC Plug (Fuse inside plug)
Emergency Light
Digital Gauge
Actual Pressure
Desired Pressure
*** Pressure
Unit Button
Power Button
Power Cord Storage
Unit of Pressure Display
Pressure Selection Dial
Hose Storage
Fuse: 15 amp (5 mm x 20 mm, 250V)
Automatic Shutoff Range: 20 psi to 99 psi
LO Setting for Manual Operation: 0 to 19 psi
Universal Adapter
**SV964200AV
* Fuse replacement instructions for plug on page 6.
** Replacement Part Numbers
*** Use a pin size object, such as a metal inflation needle, to select the desired
pressure unit desired (psi, kPa, or bar), while unit is connected to a power outlet.
Figure 1 - RP3300
www.chpower.com
3
Operating Instructions
Important Safety Information
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates
a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
IMPORTANT: Information that requires special attention.
Safety Symbols
The following Safety Symbols appear throughout this manual to alert you to important safety hazards and precautions.
MANUAL
Read manual first
Risk of overinflation
Risk of electrical shock
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
This manual contains important safety, operational and maintenance information. If you have any questions, please call 1-800-543-6400 for customer assistance.
When using tools, basic precautions should always be followed,
including the following:
CALIFORNIA PROPOSITION 65
This product or its power cord may contain chemicals, including lead,
known to the State of California to cause cancer and birth defects or
other reproductive harm. Wash hands after handling.
GENERAL SAFETY
Completely read the manual included with this product carefully. Be thoroughly familiar with the proper use of the unit.
MANUAL
Any misuse of unit
could cause property or equipment damage
and/or personal injury.
Do not leave the inflator unattended while the unit is running.
Never exceed the recommended pressure for any inflatable
object. Do not over inflate objects. Over inflation could
cause property damage and/or personal injury. Risk of bursting. Do not adjust regulator (pressure select
dial) to result in output pressure greater than marked
maximum pressure of attachement.
Do not allow inflator to run unattended while in “LO” setting.
The universal adapter must be locked to secure the
inflation accessories. Use extreme caution when using
inflation accessories. Always put the car in park; set the emergency brake; and chock the
wheels before using the inflator or property damage and/or personal
injury could occur.
Always use a separate pressure gauge to check the actual pressure in
tires and in low pressure inflatable objects.
Inflator must cool for 20 minutes after 20 minutes of continuous
operation. The Inflator is not designed to operate continuously for more
than 20 minutes.
4
www.chpower.com
Do not use inflator on high pressure tires used on large trucks, trailers
or tractors. The inflator is not designed to operate for the length of time
necessary to inflate these tires.
Make sure the universal adapter touches the core or tire valve stem.
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
RP3300
Operation
For use with 12-volt DC power outlets rated 15 amps or higher. Do not
use with older 8 amp cigarette lighter receptacles.
FOR LOW PRESSURE INFLATION - MANUAL SHUTOFF ONLY ­INFLATION OF ITEMS THAT REQUIRE LESS THAN 20 PSI
1. Plug the power cord into a power outlet. NOTE: Some vehicles require the engine to
be running to power the inflator.
2a. If inflating a low pressure tire (such as an ATV tire or lawn tractor tire), attach
universal adapter to valve stem with the locking lever in the open/up position. Press the universal adapter completely onto the valve stem thread. Failure to do so could lead to loss of tire pressure during this process.
b. If inflating a sports ball, insert a metal inflation needle into the universal adapter.
Make sure the needle is secure in the adapter.
3. When the universal adapter is firmly in place, press the locking lever down. (See
Figure 2).
4. Turn pressure selector dial until the desired pressure field reads “LO” (LO setting is
just below 20 psi setting). (See Figure 3).
5. Press power button. (See Figure 4).
6. When item reaches desired firmness, press power button again to stop inflation.
The actual pressure will then read on the digital gauge after the inflator has stopped. (See Figure 3).
If inflator immediately stops inflating and shuts off, make sure the
universal adapter is pressed fully on to the tire valve stem or the metal inflation needle is inserted correctly (See Figure 2).
7. If more inflation is needed, repeat steps 5 and 6.
8. When desired pressure is reached, raise universal adapter lever and remove from
the tire valve stem or remove the metal inflation needle.
Overinflation can be dangerous. Pay attention while inflating low
pressure items to prevent overinflation.
Unlocked
Valve Stem
Figure 2 - Lock Universal Adapter Securely
Current
Pressure
Figure 3 - Digital Pressure Gauge and Pressure Selector Dial
Universal Adapter
Locked
Metal Inflation Needle
Desired Pressure
Pressure Selector Dial
Do not allow inflator to run unattended while in “LO” setting.
FOR STANDARD TIRE INFLATION - AUTOMATIC SHUTOFF - INFLATION OF TIRES BETWEEN 20 PSI AND 99 PSI
1. Attach universal adapter to valve stem with the locking lever in the open/up
position. Press the universal adapter completely onto the valve stem thread. Failure to do so could lead to loss of tire pressure during this process.
2. When the universal adapter is firmly in place, press the locking lever down. (See
Figure 2).
3. Plug the power cord into a power outlet.
4. Turn the pressure selector dial until desired pressure is reached. (See Figure 3).
5. Press power button. (See Figure 4). Unit will turn off automatically when set
pressure is reached.
If inflator immediately stops inflating and shuts off, make sure the
universal adapter is pressed fully on to the tire valve stem (See Figure 2 ).
6. When desired pressure is reached, raise universal adapter lever and remove from
the tire valve stem or remove the metal inflation needle.
Figure 4 - Power Button
www.chpower.com
5
Operating Instructions
Maintenance
FUSE REPLACEMENT
Never replace a blown fuse with a fuse having a higher rating.
1) Unscrew end of plug counterclockwise to remove fuse.
2) If fuse is blown, replace with a new 15-amp fuse (5 mm x 20 mm, 250V). Always replace a blown fuse with the same size fuse.
3) Reassemble plug. Do not overtighten.
15 amp
Fuse
Figure 5 - Fuse Replacement
Technical Service
For information regarding the operation or repair of this product, please call 1-800-543-6400.
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Gauge is not on 1. Vehicle’s engine not running 1. Turn on your vehicle
2. Vehicle’s fuse for power outlet is blown 2. Replace fuse
3. Inflator’s fuse for power plug is blown 3. Replace fuse (see above)
Inflator will not start 1. Red power button not pressed 1. Press red power button
2. Pressure in tire may be greater than the desired pressure setting
Desired pressure unit not shown
Inflator does not shut off 1. Faulty power connection 1. Disconnect power plug. Reconnect to power outlet.
Desired pressure not selected Use a pin size object to change the desired pressure unit
2. Item you are inflating has a hole or leaks 2. Patch hole or leak
3. Inflator is not working properly 3. Call Customer Service at 1-800-543-6400
If problem can not be resolved, call 1-800-543-6400
2. Release some pressure from tire or reset desired pres­sure to a higher setting
(psi, kPa, or bar) while inflator is connected to a power source. See page 3.
6
www.chpower.com
Loading...
+ 14 hidden pages